Rule 19, GUWAHATI BUILDING BYELAWS: Foundation & Structural design
GUWAHATI BUILDING BYELAWS - Rule 19
Text of rule 19
Foundation & Structural design
19. Foundation & Structural design: -
(a) The structural design of foundation, elements made by masonry,
timbers, plain concrete, reinforced concrete, prestressed concrete and
structural steel shall be carried out in accordance with the prevailing I.S.
code of practice taking into consideration the seismic load required to be
taken for this region.
(b) Quality of material and workmanship:-
All materials and workmanship shall be of good quality conforming
generally to accepted standards of A.P.W.D. and Bureau of Indian
Standard specification & codes as included in N.B.C. of India.
(c) Damp proof course: - (Applies to non Assam type building only). All
walls internal or external shall be provided with an efficient damp proof
course not less than 150 mm above ground level.
20. No piece of land shall be used as a site for the construction of a building if.
(a) The Authority considers that site is insanitary or that it is dangerous to
construct a building on it.
(b) There is no approach road of at least 3.6 m width to that plot from the
main road if this approach road is only to single house, series of houses
cannot be constructed.
(c) If any plot is situated in already developed areas, and the means of
access is less than the minimum prescribed width, the Authority may
consider the proposal with 50% coverage and 100 FAR.
(d) Means of access
(i) No building shall be erected so as to deprive any other building
of the means of access.
(ii) Every person who erects a building shall not at any time erect or
cause or permit to erect or re-erect any building which in any
way encroaches upon and diminishes area set apart as means of
access.
(iii) For building identified in Byelaws No. 58.4, 58.7, 58.8, 58.9,
58.11 the following provisions of means of access shall be
ensured:
(a) The Authority considers that site is insanitary or that it is
dangerous to construct a building on it
or if by virtue of smallness or odd shape of the site if the
Authority considers that it is not suitable for development or if
the site is near a water body or water course and the proposed
development is likely to contaminate the said water body or
water course or change the course of the channel or if the site
is likely to be inundated and satisfactory arrangements for
proper drainage is not possible or if the site is a filled up tank
NEW REVISED BUILDING BYELAWS FOR GUWAHATI METROPOLITAN AREA-2006
Guwahati Metropolitan Dev. Authority Page No. [23]
or low lying or made up of soil by depositing rubbish or
offensive matters the proposal is likely to be effected by
dampness owing to the sub soil water or if the site does not
abut any existing public or private street.
The width of the main street in which the building abuts shall
not be less than as given below and the width of road shall be
taken as existing available road width or the road width in the
revenue record whichever is less.
Maximum road width
1. Residential/Commercial 3.6 m
2. Apartment
(A) Upto 12 m. 6.6m
(B) Above 12 m height 8 m
3. Multistoreyed commercial / Residential commercial
(Mixed use)
(A) Above 12 m. height 8m.
(B) Upto 12 m height 6.6m
4. Institutional 9m
5. Hospital / Nursing Home 9m
6. Hall for social gathering/ assembly 9m
7. Industrial / Warehouse etc and similar use 9m
N.B. :
(i) The width of a street/ road means the clear average
width of the existing carriage way and foot path and
drains only on which the building or plot abuts. The
minimum width of this existing and the proposed width
prescribed by the Authority will be taken for
calculating the maximum permissible height of
building. The average width shall be computed by
taking the width of the road at the last junction point
leading to the plot, in front of the plot and at the point
where road width is minimum, in cases where the
width of the street / road is not regular or uniform all
along the length of the road provided that minimum
road width is available at entry point, in front of the
plot and some other two points.
(ii) However in the newly developed areas the Authority
will have the power to refix the minimum road width
from time to time considering the developments in
these areas.
(iii) Interpretation of: Cl.20. (d).(iii).(a) Sl. 3 (B)
should be interpreted as follows:
Upto 12 m height road width should be in
between 3.6 m to 6.6. m.
(iv) Where the road is uniformly 6.6 m the apartment
be restricted to G+3rd floor with 175 FAR
irrespective of GF being made fully parking or
not.
Where the road width is more than 6.6 m
uniformly but less than 8 m G+4th floor with
NEW REVISED BUILDING BYELAWS FOR GUWAHATI METROPOLITAN AREA-2006
Guwahati Metropolitan Dev. Authority Page No. [24]
complete GF parking may be allowed subject to
maximum 175 FAR.
(b) A building shall abut on a street or streets or upon spaces
directly connected from the street by hard surface
approach, width of which is not less than 3.6 m
(c) If there is any bend or curve on the approach road, a
sufficient width shall be provided at the curve to enable
the fire appliances to turn, the turning circle being at least
of 9.0 m radius.
(d) Main entrance to the premises shall be of adequate width
to allow easy access to the fire engine and in no case it
shall measure less than 5 meters. The entrance gate shall
fold back against the compound wall of the premises,
thus leaving the exterior access way within the plot free
for movement of fire service vehicles. If archway is
provided over the main entrance the height of the
archway shall not be at a height less than 4 m.
(e) For group housing scheme upto 12 m height there shall be a
space of minimum 3 m. between individual buildings. For
other multistoreyed buildings there shall be a space of
minimum 4.8m between individual buildings. 20% of the total
area is to be utilized for organized recreational area /
gardening.
(f) For a building constructed on stilt with provision of ground
level parking floor or semi basement parking, the height of
building will be-calculated-as-followed-
2.7 m, G.F. height will not be calculated. But for additional
set back calculation height of building will be calculated from
actual` ground level.
(g) The minimum distance of any building from the edge of
natural drainage channels should be 4.5m.
Previous and next
Questions people ask
Is rule 19 of GUWAHATI BUILDING BYELAWS still in force?
No repeal of GUWAHATI BUILDING BYELAWS is recorded.