LawGrids logoLAWGRIDS.ORG

Rule 21, GUWAHATI BUILDING BYELAWS: Plinth

GUWAHATI BUILDING BYELAWS - Rule 21

Text of rule 21

Plinth

21. Plinth: - No person shall construct any building with its lowest flat or floor: (a) Less than 0.5 m. and more than 0.75 m. above the ground level of the plot. The ground level should not be raised more than 0.5 m from the finished surface of the nearest street level to be fixed permanently by concerned authority in the plain areas. As for the hilly area of the city the local condition will be considered. However, the proposal is to be framed with minimum of hill cutting, without effecting adjoining plots. (b) Bath rooms, water closets, cowsheds, garages, courtyards and godowns may be constructed at 0.2 mtr. Plinth height from the ground level (either existing or formed by filling or cutting). (c) 0.3 m higher than the highest recorded flood level.