Rule 54, TRIPURA BUILDING RULES — 2017: Provisions for buildings constructed under Government approved schemes
TRIPURA BUILDING RULES — 2017 - Rule 54
Text of rule 54
Provisions for buildings constructed under Government approved schemes
54. Provisions for buildings constructed under Government approved schemes.-
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(70)
Notwithstanding anything contained elsewhere in these rules the provision of
this chapter shall apply in respect of matters provided therein, in the case of
buildings constructed by Governments, or any of the statutory bodies under any
Government approved scheme, for residential use of persons belonging to
Economically Weaker Section (EWS) or Lower Income Group (LIG) or of industrial
workers.
For plotted development the minimum size of a plot shall be 40 square meters
and the maximum size of the plot shall not be more than 65 square meters.
(a) No building shall be constructed on a plot if the width of the means of
access to the site is less than 1.8 meters.
(b) No building exceeding 8.0 meters in height shall be allowed on a plot if
the width of the means of access to the site is less than 2.4 meters.
The maximum permissible ground coverage shall be 75% of the area of the plot.
The maximum height of the building shall be 14.5 meters.
The minimum front open space for a building shall be 1.0 meters.
The minimum rear open space for a building shall be 0.8 meter.
The buildings may be of the row housing type and the maximum length of the
building in a row shall be 50 meters. After every 50 meters of length of the building
in a row, there shall be an open space of not less than 2.5 meters in width for the
entire depth of the building ;
Provided that such open space shall not be necessary if there is a street or
passage at such location, the minimum width of which is 2.5 meters.
No parking space within the plot shall be necessary.
ULBs shall adopt pre-approved building plans / layout plans for Economically
Weaker Section (EWS) / Lower Income Group (LIG) housing for plot size not more
than 65 square meters. Any person belonging to EWS / LIG category may adopt any
pre-approved building plans / layout plans and directly approach to ULB for
obtaining sanction.
Page 43
55.
56.
57.
PART VI
Requirements of Parts of Buildings
Plinth.-
(1) The plinth or any part of a building or any accessory building shall be so located
with respect to the crest of the road level that adequate drainage of the site, in such
situations, the stilted portion should be suitably stiffened to resist design earthquake
forces assured and it shall in no case be at a height less than 60 centimeters.
Provisions shall have to be followed as per IS Guide listed in Annexure. Suitably
add provisions for “Low income housing (plinth max 40 Sq. meters) as per IS: 8888-1993
Guide for requirements for low-income housing".
(2) Every inner courtyard shall be raised at least 15 centimeters above the level of
the center of the nearest street and shall be satisfactorily drained.
(3) In case of buildings having parking provision at ground floor, the plinth height in
no case is at a height less than 15 centimeters.
Habitable Room. —
(1) No habitable room shall have an area less than 9.50 sq. meters having a
minimum width of 2.40 meters, where there is only one room. In case of more than one
room, one of these rooms shall be not less than 9.50 sq. meters with a width of 2.40
meters at the minimum and the others shall not be less than 7.50 sq. meters in area with
a minimum width of 2.10 meters.
(2) No habitable room shall have, a height of less than 2.75 meters measures from
the surface of the floor to the lowest point of the ceiling or the underside of any slab:
Provided that in the case of any centrally air-conditioned building, the height of
any habitable room shall not be less than 2.4 meters measured from the surface of the
floor to the underside of any slab or false ceiling, as the case may be :
Provided farther that the height from the surface of the floor up to the beam shall
not be less than 2.4 meters;
Provided also that in the case of any pitched roof the average height shall not be
less than 2.75 meters and the minimum height at caves level shall be 2.1 meters.
(3) All rooms in any buildings irrespective of their use group, utilized for human
habitation shall conform to sub-rules (1) , (2) and (3)
(4) Any room to be used as retail shop shall have a minimum clear height of 2.3
meters measured from floor to bottom of the ceiling or beam, whichever is lower;
Root.-
(1) The roof of a building shall be so constructed or framed as to permit effectual
drainage of the rain water there from by means of sufficient rain-water pipes of adequate
size, wherever required, and so arranged, joined and fixed as to ensure that the rain-
water is carried away from the building without causing dampness in any part of the
walls or foundations of the building or those of an adjacent building.
(2) The ULB may require rain-water pipes to be connected to a drain or sewer
through a covered channel formed beneath any street to connect the rain-water pipe to a
road gutter or any other approved device.
(3) Rain-water pipes shall be affixed to the outside of the walls of the buildings in
recesses or chases cut or formed in such walls or in such other manner as may be
approved by the ULB.
(4) Every terrace on the top most storey of any building shall have a common access
and shall not be sub-divided.
Page 44
58.
59.
60.
Kitchen. —
(1) No kitchen shall have a floor area of less than 4.5 sq. meters and width of less
than 1.8 meters:
Provided that if any kitchen is to be used for eating purposes also, such shall not
be less than 9.5 sq. meters and the width shall not be less than 2.4 meters.
(2) No kitchen shall have a height less than 2.5 meters measured from the
surface of a floor to the lowest point in the ceiling or the underside of any slab except
from the portion to accommodate any floor or any upper floor.
(3) Every room to be used as kitchen shall have —
(a) unless separately provided with any pantry meant for the washing of
kitchen utensils which shall land directly or through a sink to grated and trapped
connection to waste pipe;
(b) an impermeable floor;
(c) a window of not less than 1 sq. meter in area opening directly to an interior or
exterior open space, or into any shaft;
(d) a flue, if necessary;
(e) a refuse chute for discharge of solid wastes, in case of any building exceeding
18.0(eighteen) meters in height.
Pantry.-
(1) No pantry shall have a floor area of less than 3 sq. meters and a width of less
than 1.4 meters.
(2) Every pantry shall have -
(a) a means of the washing kitchen utensils, if not provided in the kitchen,
which shall lead directly or through a sink to grated and trapped connection to any waste
pipe;
(b) an impermeable floor.
Bath room and water closet.-
(1) No bathroom shall have a floor area of less than 1.8 sq. meters, with a width of
less than a1.2 meters and a height less than 2.2 meters measured from the surface of a
floor to the lowest point of the ceiling or the underside of any slab:
Provided that if it is combined bathroom and a water closet such floor area shall not be
less than 2.6 sq. meters.
(2) No water closet shall have a floor area of less than 1.1 sq. meters and a width
less than 0.9 meter.
(3) Notwithstanding the provisions of sub-rule (1) or sub-rule(2), the case of any
building referred to in rule 54, -
(a) an independent bathroom may have a floor area of 1.45 sq. meters;
(b) a combined bathroom and water closet may have a floor area of 2.0 sq.
meters, with a minimum width of 1.1 meters.
(4) Every bathroom or water closet shall —
(a) be so situated that at least one of its walls shall open to an interior or
exterior open space or shaft and shall have an interior or exterior open space
or shaft and shall have an opening in the form of window or ventilator or
lurver not less than 0.37 sq. meter in area;
(b) not be directly over any room other than a latrine or water closet or a
washing place or a bathroom or a terrace unless it has a water tight floor;
(c) have the platform or set made of water tight non-absorbent materials;
(d) be enclosed by walls or partitions and the surface of every such wall or
partition shall be finished with smooth impervious material to a height of not
less than 1 meter above the floor of such room;
Page 45
61.
62.
63.
64.
65.
(e) be provided with a door completely closing the entrance to it; and
(f) be provided with an impervious floor covering with an impervious floor
covering sloping towards any drain with a suitable grade and not towards any
veranda or other room.
(5) No room containing any water closet shall be used for any purpose except, as
a lavatory and no such room shall open directly into any kitchen or cooking space
or pantry by a door, window or other opening.
Loft. -
(1) A loft may be permitted in buildings of all use groups.
(2) The area of any such loft shall be restricted to 25 percent of the area of the floor or
any room other than inhabited room, provided that 100 percent of the area may be
covered over any corridor.
(3) Maximum height between any loft and ceiling shall be 1.20 meters and the clear
height below the loft shall not be less than 2.10 meters.
Ledge or tand. —
(1) A ledge or tand in a habitable room shall not cover more than 15 percent of the
floor on which it is constructed and shall not interfere with the ventilation of the room
under any circumstances.
(2) The ledge shall be provided at a minimum height of 2.1 meters from floor level.
(4) The maximum width of any ledge or tand shall be 0.60 meter.
Mezzanine floor. -
(1) A mezzanine floor may be permitted only between the ground floor and first floor
of any building.
(2) A mezzanine floor may be permitted over a habitable room provided that —
(a) it conforms to any standard for a habitable room as regards lighting and
ventilation;
(b) it is so constructed as not to interfere under any circumstances with the
ventilation;
(c) such mezzanine floor is not subdivided into smaller compartments;
(d) such mezzanine floor or part of it shall not be used as kitchen; and
(e) in no case a mezzanine floor shall be subdivided so as to make it liable to
be converted into unventilated compartments.
(3) An area up to 25 percent of the covered area on the ground floor shall be
allowed.
(5) The height of any mezzanine floor shall not be less than 2.1 meters.
Store room:-
No store room in any residential building shall have a floor area less than 1.5 sq.
meters and a height of less than 2.1 meters.
Garag . —
(1) No garage for cars shall be less than 2.5 meters x 5 meters.
(2) The minimum head room in a garage shall be 2.1 meters.
(3) The size of any garage where more than one motorcar is parked shall
be calculated on the basis of the number of vehicles to be parked there.
(4) No garage for trucks shall be less than 3.75 meters x 10.00 meters
with a minimum head room of 3.00 meters.