Rule 66, TRIPURA BUILDING RULES — 2017: Basement
TRIPURA BUILDING RULES — 2017 - Rule 66
Text of rule 66
Basement
66. Basement. -
(1) Subject to specifications, if any, made in this behalf under the Tripura
Town and Country Planning Act,1975, the ULB may specify any area or ward
where the construction of any basement shall not be permitted.
(2)
(3)
A basement may be used as —
(a) a parking space;
(b) an air-conditioning plant room or room for other machines
used for any building service or for other purposes,
(c) a space for a stand by generator for power supply,
(d) a storage space for house hold or other goods of non-
inflammable nature,
(e) a strong room or bank locker,
(f) a dark room,
(g) a stack room in any library, or
(h) a business building, or mercantile building (retail)., or assembly
building, if it is air-conditioned.
Outer walls of a basement shall not extend to the exterior open
spaces as required under these rules.
(4) No basement or portion thereof shall be used for residential
purpose.
(5)
(6)
No kitchen, bathroom or water closet shall be permitted in any basement
unless the sewer levels permit the same and there is no chance of back flow and
flooding of sewerage. lf permitted, such kitchen, bathroom or water closet shall
be placed against an external wall of the basement, which shall also be the
external wall of the building and shall be adequately lighted and ventilated.
Detailed plans showing arrangement for drainage including pumping system shall
be submitted in such cases.
Every basement shall -
(a) in every part be at least 2.4 meters in height from the floor to the
underside of the roof slab or ceiling or any false roofing;
(b) have adequate arrangement so that surface drainage does not enter the
basement, and have adequate arrangement for pumping out water, if necessary;
(c) have water-tight walls and floors which shall be so designed that the
effect of the surrounding soil and moisture, if any, is taken into account in design
and adequate damp-proofing treatment is given;
(d) have access by means of two or more ramps and a staircase, which are
separated from the main and alternate staircase providing access and exit from
higher level floors, the width of each ramp shall not be less than 3.5 meters and
the slope shall not be steeper than 1(one) vertical to 6(six) horizontal and the
distance between the ramps shall be such as may be determined by the
Mayor/Chairperson of the ULB.
(e) in the case of such basement being used for a purpose as referred to in
clause(g) of sub-rule(2), have sufficient numbers of access ways and exit ways
so that the travel distance is not more than 15 meters;
(f) have adequate ventilation as required far any occupancy or use group
under these rules :
provided that any deficiency may be met by providing adequate
mechanical ventilation in the form of bowlers, exhaust fans at the, rate of one
exhaust fan for every 50 sq. meters of the basement area, or by air-conditioning;
(g) comply with the requirements of the Tripura Fire Service Act as in forced
in the State of Tripura and the rules and the directions made or issued there
undeL
Page 47
67.
68.
69.
70.
Chimney.-
(1) Any chimney shall conform to the requirements of the latest version of IS: 1645-
1960 Code of practice for fire safety of buildings (general), chimneys, flues, flue pipes
and hearths.
(2) Any chimney shall be built at least 0.9 meter above any flat roof;
Provided that the top of any chimney shall not be below the top of any adjacent
wall and, in the case of a slopping roof, the top of the chimney shall not be less than 0.6
meters above the ridge thereof in which the chimney penetrates.
Parapet.-
A parapet wall and guardrails shall be provided on the edge of any roof terrace
or balcony and it shall not be more than 1.5 meters in height.
Boundary wal .-
No boundary wall shall exceed 2 meter in height above the center/ine of the road
abutting to the plot, the solid portion of compound walls shall not exceed 1.5 meters in
height. The foundation of boundary wall, below ground level, shall not encroach upon
any adjacent land outside the plot area.
Qghting and ventilation of room.-
(1) Every habitable room, kitchen/ staircase and bathroom or water closet shall
have, for the admission of light and air one or more apparatuses, such as windows,
glazed doors and fan lights, opening directly to the external/air or into an open verandah.
(2) In any case where light and ventilation requirements are not met through day
lighting and natural ventilation, the same shall be ensured through artificial lighting and
mechanical ventilation as per the latest provisions of section 1 of Lighting and Ventilation
of part VIII on Building Services of the latest edition of the National Building Code of
India :
Provided that the minimum aggregate area of the openings of habitable room
and kitchens, excluding doors, shall in no case be less than one-tenth of the floor area.
(3) No portion of any habitable room shall be assumed to be lighted if it is more than
7.5 meters from the opening assumed for lighting that portion.
(4) The planning, design and installation of lighting and ventilation, electrical
installations and fittings, air-conditioning and heating work, a caustics, sound insulations
and noise control the number, type and installations of lifts and escalators shall be
carried out in accordance with the provisions of building services of the latest edition of
the National Electrical Code of India :
Provided that for electrical installation in respect of any buildings the provisions of
the latest edition of the National Electrical Code and Indian Electricity Rules shall apply:
Provided further that the planning, design, construction and installation of water
supply, drainage, sanitation and gas supply systems shall be in accordance with the
provisions of planning services of the latest edition of National Code of India.
Page 48
71.
72.
73.
Definitions.-
PART VII
Exit Requirements of Buildings
In this Chapter unless the context otherwise requires, -
(a) "exit" means a passage, channel or means of access from any building, storey’s
or floor area to a street or other open space of safety and includes a vertical exit
or a horizontal exit or an outside exit.
(i) “vertical exit” means an exit used for ascension or descension between
two or more levels including stairways smoke proof, ramps, lifts,
escalators and fire escapes,
(ii) “horizontal exit” means a protected opening through or around a fire wall
or a bridge connecting two buildings,
(iii) outside exit” means an exit from the building to a street or to an open area
leading to a street or to an enclosed fire resistive passage leading to a
street;
(b) “travel distance” means the distance from the exit of any premises on a floor of a
building to a place of safety, be it a vertical exit, a horizontal exit or an outside exit,
measured along the line of travel.
Fire protection.-
Every building of more than 12.50 meter height and/or having covered area of
more than 500 sqm shall be provided with adequate means of exit and all arrangement
for protection in case of fire in accordance with the provisions contained in the latest
version of National Building Code.
General exit requirements.-
(1) The following general requirements shall apply to exit:-
(a)
(b)
(C)
(d)
(e)
(f)
(9)
(h)
all exits shall be free from obstructions;
no building shall be altered so as to reduce the number , with or
protection of exits to less than what is required under these rules;
exits shall be clearly visible and routes to reach each exit shall be
clearly marked;
all exits shall be properly illuminated;
fire-fighting equipments shall, where provided along exits, be
suitably located and clearly marked so as not to obstruct the exit
way and there shall be clear indication from either side of the exit;
alarm devices shall be installed to ensure prompt evacuation
through exits;
all exits shall provide continuous means of access to the exterior
of a building or to an exterior open leading to a street or means of
access;
exits shall be so arranged that they may be reached without
passing through another occupancy unit, except in the case of a
building for residential and educational uses.
(2) An exit may be a door-way, corridor, passage way to staircase, ramp or a
verandah or terrace which has access to the street or to the roof of a building. An exit
may also include a horizontal exit leading to building at the same level.
(3) Lifts and escalators shall not be considered as exits.
(4) All basements shall have a minimum of 2(two) exits.
Explanation — Ramps to the basement shall be considered as exits.
Page 49
74.
75.
76.
Arrangements of exits.-
(1)
(2)
(3)
(4)
Exits shall be so located that the distance between 2(two) exits on the floor shall
not exceed-
(a) 22.5 meters, in the case of a residential building or an educational
building or institutional building or hazardous building; and
(b) 30 meters, in the case if an assembly building or a business building or a
mercantile building or an industrial building or a storage building.
For floors with sprinklers, which are not part of requirements for the floor and
occupancy, the distance in sub-rule(1) may be increased by 50 percent.
The distance to an exit front the dead end of a corridor shall not exceed half the
distance specified in sub-rule(1), except in an educational building or an
assembly building or an institutional building in which case it shall not exceed 6
meters.
Whenever more than one exit is required for any room space or floor of building,
exits shall be placed as remote from each other as possible and shall be
arranged to provide direct access in separate directions from any part in the area
served.
Requirements regarding staircase. —
All building referred to in rule 72 shall be provided with such number of staircase
as the ULB require. Under no circumstances, the number of staircases shall be less than
2(two) in the case of a building of more than 14.0(fourteen) meters in height and one of
them shall be on the external face of the building.
Minimum width provisions for Staircase.-
(a)
The following provisions for minimum width for staircase(s) shall be made:-
for each stairway in a residential building having not more than 2(two) tenements
per floor, the minimum width shall be -
(b)
(C)
(d)
(e)
(i) 0.90metre in the case of a building having above 11 meters in height.
(ii) 1.05 meters in the case of a building having above 11 meters and up to
14.0 meters in height.
(iii) 1.25 meters for primary stairway in the case of building above 14.5
meters in height.
every additional tenements per floor to be served by the same staircase. The
width of each stairway shall be increased by 0.15 meter, provided that for
buildings constructed under the each of stairway shall not be less than 0.90
meter.
for each stairway in institutional or mercantile buildings, the minimum width shall
be 2.0 meters;
for each stairway in educational or business or assembly buildings other than
theatre, motion picture house, city hall, dance hall, auditorium, exhibition hall or
similar other halls or such other places, the minimum width shall be 1.80 meters;
(i) for assembly buildings not included in clause (b) above, the minimum
width of each stairways shall be 1.80 meters where not more than 300 persons
are to be accommodated,
(ii) for the accommodation of more than 300 persons, the minimum width of
stairway as at (a) above shall be increased by 0.30 meter for every additional
100 persons or part thereof over 300 persons,
(iii) notwithstanding anything contained in sub-clause(ii), instead of a single
staircase, corridor or passageway of the width prescribed by the said sub-rule,
there may be two or more staircases, corridors or passageways as may be
Page 50
77.
sufficient for the number of persons that can accommodated in the building,
each having a width as prescribed in sub-rule(i);
(f) for all other buildings, the minimum width of each stainNay shall be 1.50 meters;
(9) the minimum width of a passage or corridor shall be as follows :-
(i) for passage connecting vertical exits and the apartments/ units, the width
shall not be less than the width of each stainNays specified in clause(a) to
(e) except for mercantile business buildings and assembly buildings;
(ii) for a passage within a apartment, the width shall not be less than 0.90
meter;
(iii) for a passage giving access to shops in a mercantile building, the width
shall not be less than 2 meters if the shops are on one side only, and 3
meters if the shops are on both sides;
(iv) for a passage in a business building, the width shall not be less than 2.50
meters;
(v) .for a passage in an assembly building, the width shall not be less than
that as derived under sub-clause(i),(ii) and (iii) of clause (e).
Provisions for doors for an assembly room or hall.-
The doors of a room or a hall, where groups of people congregate or gather in
any building, shall be made to open outside shall be affixed thereto. There shall be at
least 2(two) such doors in every such room or hall if not more than 300 persons are
intended to be accommodated therein and an additional door shall be provided for every
100 persons or part thereof in excess of 300 persons. The width of every such door shall
not be less than 1.80 meters.