Rule 49, TRIPURA BUILDING RULES — 2017: Provision of parking space for a building within a plot
TRIPURA BUILDING RULES — 2017 - Rule 49
Text of rule 49
Provision of parking space for a building within a plot
49. Provision of parking space for a building within a plot. —
(1)
(a)
(b)
(C)
(d)
(e)
(f)
(9)
(h)
(i)
(2)
Generally -
the minimum size of a car parking space shall be 2.40 metres x 4.50
metres and that for a truck or bus parking space shall be 3.75 metres x 10.00
metres. These spaces do not include the area of circulation internal roads,
aisles and driveways. The minimum width of an internal circulation road shall
be 3.50 metres for cars and 5.00 metres for trucks;
in calculating the number of parking Spaces as per the norms laid down
in sub-rule (2) hereinafter the covered area shall be the same as the total
covered area of the building but shall exclude the area of covered parking
spaces, if any;
the parking lay-out plan shall be so prepared that the parking space for
each vehicle becomes directly accessible from the drive-way or circulation
drive-way or aisles. This clause shall not be applicable to residential building up
to 14.0 metres in height;
the open spaces within the plot may be allowed to be utilized for car
parking spaces open to the sky provided that the minimum front, rear and side
open spaces prescribed in rule 48 & 50 as the case may be, shall be kept free
from parking;
for areas with different occupations in a building the number of parking
spaces shall be worked out on the basis of each of the occupancies separately
and total number of parking spaces required for the building;
in case of a plot containing more than one building; parking requirement
shall be calculated for each building separately, on the basis of use of each
building;
in calculating the areas of different occupancies in the same building, the
areas of common spaces of any floor, which are included in the calculation of
the total covered area shall be distributed proportionately amongst the different
occupancies;
for plots in a scheme for Economically Weaker Section and Lower
Income Group Housing under Government approved schemes, the
parking requirement shall be as indicated in Rule 54.
for plots with means of access of less than 2.40 meters in width, car parking
space may not be provided;
The minimum parking requirement shall be as follows-
Minimum parking requirement
Use of building Covered area No. of No. of No. of
(sq. meter) car Truck Bus
Upto 70 Nil Nil Nil
. . Beyond 70 for
Res’dent’a’ every 100 or part 01 Nil Nil
there of
Upto 50 Nil Nil Nil
. . Beyond 50 forCommerCIaI/Busmess every 75 or part 01 Nil Nil
there of
Assembly houses like restaurant, Every 100 or part
eating house, Bars, Clubs & there of 01 Nil Nil
Gymkhana or such other
Assembly like Hotel & Boarding Every 200 or part . .01 Nil Nilhouses or such other there of
Assembly like Theatre, Motion Every 100 or part 01 Nil Nil
Page 38
(3)
picture, City hall, Town hall, there of
Auditorium or such other
Institutional like Hospital & Health Every 100 or part . .01 Nil Nilcare or such other there of
Every 400 or part 01 Nil Nil
. there ofEducational Every 1000 or Nil Nil 01
part there of
Every 400 or part . .
Industrial, Storage & Hazardous or there of 01 N” N”
such other Every 1000 or Nil 01 Nil
part there of
In case stilt structures are included in the building plan for parking or other use
then providing adequate shear walls and/or cross bracings in stilt structures is
mandatory.
50. Tall buildings (exceeding fourteen and half meters in height).
In ULB the building height shall not normally be more than 14.50 meters
(fourteen and halfl. But in the case of any building exceeding 14.50 meters in height,
the ULB, for reasons to be recorded in writing and with the previous approval of the
State Government with the support of the Technical Appraisal Committee (TAC)
constituted as per sub-rule 8 of this rule, may sanction such proposal(s) as special
case if not otherwise covered by any law for the time being in force. In such cases the
following special rules shall be applicable in addition to other rules under the Act:-
(1)
(2)
(3)
(4)
(5)
no building exceeding 14.5 (fourteen and half) meters height shall be allowed on
private or public street of less than 15.00 meters in width;
for every category of building referred to in rule 49(2) and exceeding 14.5
(fourteen and halfl meters in height shall have a front open space of not less
than 20% of the height of the building or 6 meters at its narrowest part,
whichever is less subject to minimum as specified in rule 48(2).
(a) every building exceeding fourteen and half meters but not exceeding
18.0 (eighteen) meters in height shall have a rear open space at ground along the
entire width of the building forming an integral part of site of a minimum width of
five meters;
(b) every building exceeding 18.0 (eighteen) meters in height shall have a
rear open space at ground along the entire width of the building forming an
integral part of the site of 20% of the height of the building subject to the
minimum of five meters;
(a) the minimum side open space of a building exceeding 14.5(fourteen and
half) meters but not exceeding 18.0(eighteen) meters in height shall be 3 meters
and 50 centimeters on either side or more;
(b) the minimum side open space of a building exceeding eighteen meters in
height shall be 20% of the height of the building subject to the minimum of
five meters and fifty centimeters on either side;
(c ) in the case of a building of more than 24 meters in depth and not exceeding
18 meters in height one of the side shall be at least 4 meters in width;
(a) in case the whole of one side or part of at least two sides of every room
excepting bath, water-closets and store-room, is not abutting either the front,
Page 39
rear or side open spaces, it shall abut an inner courtyard whose minimum width
shall be 20% of the height of the building or 3 meters, which ever is more;
(b) for ventilating water closet in bathroom such water closet or
bathroom or kitchen or any room not intended for human habitation, if not opening
on to front, rear, side or interior open space, shall be up to a ventilation shaft, the
size of which shall not be less than the values given below :
Height of building (meters) Area of ventilation Minimum width of shaft
shaft (sq. meters) (meters)
Above 14.00 but not more than 6.00 2.40
18.00
Above 18.00 8.00 2.40
For building of height of more than 14.50 meters in height a mechanical ventilation
system shall be installed besides the provision of ventilation shaft;
(0) if there be building other than boundary wall of not more than three sides of a
court yard, the minimum width shall be 20% of the height of the building or 2.50 meters
which ever is more;
(6) (a) for every building exceeding fourteen and half meters in height, the Floor
Area Ratio shall be as specified in the table below :
TABLE
Maximum Permissible Floor Area Ratio (FAR)
Width of means ofAccess Residential Building Institutional,
Business and
other Buildings(meters) Commercial Other Zone
Zone, if any
1. Above 14.5 to 20.00 2. 50 2. 75 2. 50
2. Above 20.00 2.75 3.00 2. 75
(7)
(8)
(b) while calculating the floor area under this Chapter, the following shall be
excluded namely :-
(i) stair cover not exceeding 2.4 meters in height,
(ii) lift machine room as per latest edition of the National Building code,
(iii) roof tanks with their support, the height shall not exceeding 1.8 meters,
(iv) chimney, ventilating, air-conditioning and service equipment attached to
the building:
Provided that the aggregate area of these structures mentioned at (i) to (iv)
above shall not exceed one-third area of the roof upon which these are
erected,
(v) the area of covered car parking spaces as may have been provided for
the required number of car parking, spaces in accordance with rule 50,
and for this calculation the area required for one car parking space shall
be taken as 20 sq. meters inclusive of all circulation spaces.
for construction of steel towers, the criteria specified for buildings above 14.5
meters in height shall be followed .
A Technical Appraisal Committee (TAC) as provided in rule 50 shall be
constituted by the Urban Development Department which will support the State
Government in giving approval of building plan having height more than 14.5
meter.
Page 40
51.
PART-V
Regulation for more than one building in one plot
Regulation for more win one building in one plotI existing building and the
buildings under Govt. approved schemes:-
(1) (a) Every building on a plot containing more than 1(one) building shall abut an
internal road connecting the means of access of the plot.
(b) The minimum width of such internal roads shall be 3.50 meters where
internal road of 3.50 meters in width is not possible to be provided due to an existing
building constructed prior to the enforcement of these rules, a building of not more than
8.0 meters in height may be allowed, provided that the width of the internal road shall not
be less than 1.20 meters.
(c) The maximum permissible height of any building on a plot shall be
determined by the width of the means of access on which the plot abuts according to the
table given in sub-rule(3) of rule — 48.
(d) The minimum width and the maximum length of all such internal roads
shall be as prescribed in the table below:
Width of means of access Maximum length of the means of access
For means of access For means of access
closed at one end open to street at both
ends
(i) 3.50 meters and above but not 25.00 meters 75.00 meters
more than 7.00 meters
(ii) Above 7.00 meters but not more 50.00 meters 150.00 meters
than 10.00 meters
(iii) Above 10.00 meters No restriction No restriction
(e) In case the buildings within a plot which are not of the same occupancy, an
individual building of any particular occupancy shall comply with the rules governing
such occupancy except the provisions regarding ground coverage which shall be in
accordance with sub-rule(2) of this rule.
(2) Ground Coverage shall be as laid down below :-
for plots measuring 5,000 sq. mts or more in area, the maximum permissible ground
coverage shall be 45% for residential or education buildings and 35% for buildings of
other use groups or for buildings with mixed occupancies :
provided that the provisions of rule 47 shall be applicable to plots measuring less than
5,000 sq. meters.
(3) open space for Building shall be as laid down below :-
(a) every building shall have minimum external open space prescribed in Rule
49, provided that on these open spaces internal roads may be constructed.
(b) for plots measuring more than 5000 sq. meters in area, provision of 8% of the
total area of the plot is to be kept as public open space. The width of each such open
space shall not be less than 10.00 meters and each such open space shall abut a street
having a width not less than 7.00 meters. The minimum area of each of such open
space in one parcel shall be 400 sq. meters This open space shall be in addition to the
land required for providing the means of access to the individual plots as prescribed in
rule 46.
(c ) for plot measuring more than 25000 sq. meters in area provision of 7% of
the total area of the plot shall be reserved for use for facilities like School, Health
Page 41
52.
53.
Centres, Market, Police Outpost with both Post Office, Power Sub-station, Transport
Terminal water Treatment plant, Sewerage Treatment plant and the like, such land shall
abut a street having a width of not less than 10.00 meters in addition to the land
necessary for means of access and for open spaces sanctioned in clause(b) of this sub-
rule.
(4) The parking provision shall be the same as stipulated in rule 49.
Provisions regarding existing building. —
(1) The provisions of these rules shall apply only in the case of an existing building.
Existing building, for this purpose, shall mean any building which was erected before the
date of coming into force of these rules in accordance with a building plan sanctioned by
a authority competent to sanction such building plan under the Tripura municipality Act,
1994 or any other law for the time being in force.
(2) In the case of existing building. -
(a) excepting storage buildings, where the open spaces required have not
been provided an addition in the number of storeys, if otherwise permissible, may be
allowed with a se back, provided such building continues with the same occupancy :
provided that no formal set back may be necessary up to a height of 8.0(eight)
meters for adding only one floor over an existing single storied residential building;
(b) the extent of the set back from the property boundary shall be such as to make
the addition to the building conform to the provisions of rules 47 and 49;
(c) if any car parking space is required to be provided under these rules and no
such car parking space can be provided in such existing building, the covered area
allowable under the provisions of these rules shall be reduced by the area required
for such car parking space which can not be provided in the said building;
Explanation.- For the purpose of calculation, the area required for one car parking
space shall be taken as 20.00 sq. meters.
(d)the height of the building shall conform to the rules as indicated in rule 48 and in
no case after addition the height shall exceed 14.0 meters ;
(e) the addition to an existing building with residential occupancy shall not exceed
200.00 sq. meters in covered area;
(f) the addition to an existing building with educational occupancy shall riot exceed
the total covered area of the existing building;
(g)the addition to an existing building with other occupancies including mixed use
building but excepting storage building shall not exceed 100.00 sq.meters in
covered areas;
(h) in case of partition of existing buildings common wall may be allowed as the
partition line.
Provisions for Maintenance, Demolition of an existing building/structure:-
In case of any report(s) against an existing building/structure or part thereof or is
older than 50(fifty) years and is not safe for human habitation or any other purposes,
a Joint Expert team, constituted by the competent authority, comprising expert(s)
from ULB and PWD will verify that reported building/structure and submit a report to
the competent authority regarding the latest structural condition of that
building/structure or part thereof and the authority will take decision about its
continuation of existence or demolition or necessary repairing works needed to be
undertaken on the basis of the report of the Joint Expert team. In that case, if any
safeguard measure or measures are required to be taken or it becomes necessary
to demolish the reported building/structure, the owner(s) shall have to do it within the
time-bound period at his/their own cost or the authority will take necessary
measures accordingly.