Annexure A, Legal Metrology (General) Rule, 2011: ANNEXUREA

Legal Metrology (General) Rule, 2011 - Annexure A

Text of annexure A

ANNEXUREA

ANNEXUREA TEmNG PROCEDURES FOR DISCONTINUOUSTOTALIZING AUTOMATIC WEIGHING INSTRUMENTS (Mandatory) Meaning of symbols : I = Indication L= Load f. L= Additional load to next changeover point P= I+ 0.5d -t.L = Indication prior to rounding E= P - L = error Eo: Error calculated at zero Ee= Corrected error rnpe= Maximum permissible error EUT = Equipment under test 1. Documentation [Paragraph 5(1)(1)] Review the documentation that Is submitted, Including necessary photographs, drawings, diagrams, general software information, relevant technical and functional description of main components, devices etc. to determine If it. is adequate and correct. Consider the operational manual. 2. Comparing construction with docu-, mentation {Paragraph 5(1)(/)J Examine the various devices of the instrument to ensure compllance with the documentation. 3. Initial examination (1) Metrological characteristics Note metrological characteristics according to the test report format. (2) Descriptive markings [Paragraph 3(7)} Check the descriptive markings according to the checklist given in the test report format. (3) Sealingand verification marks [Paragraph 3(6) and Paragraph 3(8)} Check the arrangements for sealing and verification. marks according to the checklist given in the test report format. 4. General (1) General requirements for electronic instruments under test (EUT) (i) Power supply Energize the EUT. for a time period equal to or greater than the warm-up time specified by the manufacturer and maintain it energized for the duration of the test. · ( ii) Zero-setting Adjust the EUT as closely as practicable to zero prior to each test, and do not readjust it at any time during the test, except to reset it if a significant fault has been indicated. (iii) Temperature The tests shall be performed at a steady ambient temperature, usually normal room temperature unless otherwise specified. The temperature Is deemed to be steady when the difference between the extreme temperatures noted during the test does not exceed one-fi?h of the temperature range of the instrument without being greater than s0c and the· rate of change does not exceed soc per hour. The handling of the Instrument shall be such that no condensation of water occurs on the instrument. (2) Control instrument and test standards [Paragraph 6(1)} (i) Control instruments A control instrument. meeting the requirements of clause Paragraph 6(1) shall be used for conduct of material tests. Where necessary, standard weights may be used to assess the rounding error. (Ii) Use of standard weights to assess rounding error For instruments with digital indication having scale interval d, changeover points may be used to interpolate between scale intervals i.e. to determine the indication of the instrument, prior to rounding, as follows. At a certain load, L, the indicated value, I, is noted. Additional weights of for example 0.1 dare successively added until the indication of the instrument Is increased unambiguously by one scale Interval (I + d). The additional load t. L added to the load receptor gives the --· ··------ . -- _J_. _ 492 THE GAZETTE OF INDIA: EXTRAORDINARY fPART II-SEC. 3(i)] indication, P,"priorto rounding:by using the followingformula :- P = I,+ O,S d • til The errcr.pnor. to,rounding Is : E = P -t, thus E = (1"+"0,Sd • t, L) • l The corrected error prior to rounding Is : Ec=E·Eo Where Eo'Is the error calculated at zero. Example: an Instrument with a scale interval, d, · of 1 kg is loaded,wlth 100 ·kg and thereby indicates 100 kg. After adding .successtve weights of 0.1 kg, the Indication changes from 100 kg to 101 kg at an additional load of ,0:3 kg. Inserted In the above formula these observations give : P = (100 + 0:5 • 0.3) kg = 100.2 kg Thus the true Indication prior to rounding is 100.2 kg, and theerror is : E = (100.2 - :100) kg =0.2 If the error prlor to rounding as calculated above was E0 =+0.4 kg, the corrected error Is : Ee 7 0.2 kg • {+0.4 kg) = 0.2 kg 5. Test program (1) Pattern evaluation [Paragraph 5(1)} All tests In sections Paragraph 6 to Paragraph 9 of this Annex shall normally be applied for pattern evaluation. Paragraph 6(1) of this Annex may be omitted if the integral instrument Is not to be used as the control indicating device for material testing. Tests in Paragraph 7(1), Paragraph 8(3)(11), Paragraph 8(3)(ill) (AC supply), Paragraph 8(3)(iv) (DC supply) and Paragraph 8(4)(i) to Paragraph 8(4)(iv) of this Annex apply only for instruments that have an electrical power supply. (2) Initial verification [Paragraph 5(2)} Only paragraph 6 of this Annexure 'Metrological performance tests' is normally required for initial verification tests. 6. Metrologlcal performance test:s Metrologlcal performance tests shall be applied to the complete Instrument under normal operating conditions, except when the size and/or configuration of the instrument does not lend itself to testing as a unit. In such cases, the separate electronic devices shall be subjected to testing. (1) Zero-setting device [Paragraph 3(2)(vi)] (i) General Zero-setting may be by more than one mode, for example : (a) Non-automatic or semi-automatic zero; (b) Automatic zero at switch-on; (c) Automatic zero at start of automatic operation; (d) Automatic zero as part of weighing cycle. It is normally only necessary to test the range and accuracy of zero-setting In one mode. If zero is set as part of the automatic weighing cycle then this mode shall be tested. To test automatic zero it is necessary to allow the instrument to operate through the appropriate part of the automatic cycle and then to halt the instrument before testing. (ii) Range of zero-setting Non-automatic and semi-automatic zero­ setting Positive range With the load receptor empty, set the instrument to zero. Place a test load on the load receptor and use the zero-setting device. Continue to increment the.test load until the device fails to re· zero. The maximum load that can be re-zeroed Is the positive portion of the zero-setting range. Negative range Steps: (a) Remove any load from the load receptor and set the instrument to zero. Then, if possible remove non­ essential components of the load receptor, such that the instrument , cannot be re-zeroed by use of the zero setting device. (If this is not possible then any mass that can be removed without disabling the zero function may be considered as tlie negative portion of the zero-setting range). (b) Add weights to the load receptor until the instrument indicates zero again. (c) Then remove weights and, after each weight Is removed, use the zero-setting device. The maximum load that can be removed while the instrument can still be re-zeroed by the zero-setting device, is the negative portion of the zero-setting range. (d) Alternatively, and if it is not possible to test the negative range of zero­ setting by removing parts of the ['WT Il--:"&1163(i)] 493 Instrument, then the instrument may be temporarily recalibrated with a test load applied before proceeding to step (c) above. (The test load applied for the temporary recalibration should be greater than the permissible negative zero-setting range which can be calculated from the result of the positive range test. (e) If it Is not possible to test the negative zero-setting range by these methods then only the positive part of the zero-setting range need be considered. (ii) Reassemble or recalibrate the instrument . for normal use after the above tests The zero-setting range is the sum of the positive and negative portions. (iii) Accuracy of zero-setting (a) Set the instrument to zero. (b) Add weights to the load receptor to determine the additional load at which the indication changes from zero to one scale interval above zero. (c) Calculate the error at zero according to the description in Paragraph 4(2) of this Annex. (2) Material tests [Paragraph S(l}(iii)(b) and Paragraph 5(2}(i)(b)} (i) Mater/al test requirements Material tests shall be conducted with the material, test load, requirements and methods in: (a) Paragraph S(l)(iii)(b) for pattern examination; (b) Paragraph 5(2)(i)(b) for initial verification and in-service inspection; (c) Paragraph 6(2)(ii) or 6(2)(111)of this Annex (using one of the methods therein). (ii) Separate verification method For this method a separate control instrument Is used to weigh the material either before or after it is weighed on the discontinuous totalizing automatic weighting Instrument. (iii) Integral verification method For this method the integral control instrument is used for static weighting of material test loads by use of a special facility to interrupt operation during the automatic process: (a) Integral verification method weighing test The weighing performance may be determined as follows, prior to the material tests, when the integral verification method is to be used for determ in Ing the errors in material testing. Apply test loads from zero up to and including Max, and similarly remove the test loads back to zero. When determining the Initial intrinsic error, at least 10 different test loads shall be selected, and for other weighing tests at least 5 shall be selected. The test loads selected shall include Max and Min so that the errors may be determined for the nominal hopper loads that will be used in the material tests. Determine the error at each test load using the procedure in Paragraph 4(2)(ii) of this Annex if necessary to obtain the accuracy requirements of Paragraph 4(2)(i) of this Annex. It should be noted that when loading or unloading weights the load shall be progressively increased or decreased. Errors of indication shall be recorded and taken Into account when determining the errors in material testing. (b) Substitution material Apply test loads from zero up to and including the maximum portion of standard weights. Determine the error [Paragraph 4(2) of this Annex] and then remove the weights so that the no-load indication is reached. Substitute the previous weights with substitution material until the same changeover point as used for the determination of the error Is reached. Repeat the above procedure until Max of the instrument is reached. 494 THE GAZETTE OF INDIA: EXTRAORDINARY [PARTII-SEC. 3(i)] Unload ln·reverse order to zero, i.e. unload the weights and determine the changeover point. Load the weights back on and remove the substitution material until the same changeover point is reached. Repeat this procedure until no-load indication is .reached. Similar .equivalent procedures may be applied. (c) Method (c-t) Automatic gross weighing Automatic operation Is Interrupted after the filling of the weigh hopper and completion of the automatic gross weighing but before discharge of the hopper. Thus the hopper remains loaded. (c-2) Static gross indication Then, all surrounding equipments such as dust extractors shall be stopped. When the system has come to a complete rest such that the conditions are identica I to those for non-automatic testing, the static control weighing indication shall be obtained. lf necessary, standard weights may be used to interpolate between scale Intervals. The static control indication shall be corrected for the errors determine in Paragraph 6(2)(111){a) of this Annex (for Increasing loads) (c-3) All surrounding equipment is started up again. (c-4) Automatic tare weighing Automatic operation Is Interrupted after the discharge of the weigh hopper and completion of the automatic tare weighing but before the hopper is loaded again. (c-5) Static tare indication Repeat stage (2) with an empty hopper. The static indication shall be corrected for the errors determined In Paragraph 6(2)(111)(a) of this Annex (for decreasing loads). (c-6) The complete system Is started up again and stages (1) through (5) are repeated. (c-7) The net weight of the material delivered at each cycle is determined by subtracting the corrected indication obtained at (5) from the corrected indication obtained at (2). (c-s) The conventional true value of the mass of the total test load is determined by summation of the net weights obtained at each cycle. If the instrument Is installed in an alr­ enclosed system, the moving mass of material causes air turbulence that can affect the weighing results. To ensure that such an instrument Is tested in normal conditions of use, the automatic operation . shall not be interrupted during consecutive weighing cycles. In this case it is necessary for the automatic weighingmade at stages (2) and (4) to be displayed or recorded so that a separate total may be derived for the automatic weighing which has also been carried out under static conditions. (Iv) Material test procedure [Paragraph S(J)(iii}{a) and Paragraph 5(2)(i)(b)J The test procedure shall be as follows :- (a) Start up the automatic weighing system, including the surrounding equipment which is normally in use when the Instrument is itself in use. (b) Run the system for five weigh cycles (or more if necessary) to ensure normal working conditions. (c) Halt the automatic weighing system and record the indication of totallzed weight. (d) Run the weighing system for a number of weighing cycles as specified for each test in Paragraph 6(2)(i) of this Annex, ensuring that the processed material can be weighed on the control instrument (integral or separate) in accordance with one of the alternative methods of Paragraph 6(2)(ii) of this Annex or 6(2)(iii) of this Annex. (e) Halt the weighing system, and record the final Indication of totalized weight. (f) Determine the indicated totallzed weight for the test from the difference between the indication at start (3) and finish (5). -- - ------------- ------- [ "flTT II - "\liUs 3 ( i) ] 495 (g) Repeat the above procedure for further tests as specified in Paragraph 6(2)(i)(d) of this Annex. (h) Determine the material test error from the difference between the Indicated totalized weight as determined in (6) and the total weight of material determined using the control instrument as in (4). (v) cetcutetton of material test error [Paragraph S(l}(iii)(a) and Paragraph 5{2)(lj(b)] When calculating the error It is necessary to consider the scale interval of the control indicating device and the number of sub­ divisions of the test load. Separate verification method [Paragraph 6(2)) The weight value(s) on the separate control instrument is noted. Integral verification method [Paragraph 6(3)} A The weight values obtained under static conditions on the control indicatingdevice or those values obtained by balancing with · standard weights are noted and totalized. For each weighing cycle, the net value is the difference between the values obtained In stages (2) and (5) in Paragraph 6(2)(1ii)(c). B The weight values obtained automatically on the principal totalizatlon Indicating device are noted and totallzed. For each weighing cycle, the net value is the difference between the values obtained in (1) and (4) in Paragraph 6(2)(111)(c). For each method, the difference between the values obtained from the totalization indication and 'from the separate control instrument or between procedures A and B in the integral verification method, represents the automatic weighing error. This is the value that shall be used for comparison with the appropriate maximum permissible error for automatic weighing in Paragraph 2(2)(1). 7. Additional functionality (1) werm-op time test [Paragraph 4(3)(v)J (i) Disconnect the instrument from the supply for a period of at least 8 hours prior to the test. (ii) Reconnect the instrument and switch on while observing the control indicating device (if present) and the totalization indlcator(s}. Verify that it is not possible to Initiate automatic weighing or printout until all indicators have stabilized, or until completion of the warm-up time if this Is specified by the manufacturer. (iii) As soon as the indication of the control indicating device (if present) has stabilized, set the Instrument to zero and determine the error of zero setting according to Paragraph 6(1)(iii) of this Annex. {iv) Apply a load close to Max. Determine the error by the method in Paragraph 4(2) of this Annex. (v) Repeat stages (3) and (4) after 5, 15 and . 30 minutes: (2) Agreement between Indicating and printing devices [Paragraph 2(6)} During the course of the tests verify that for the same load, the difference between any two indicating devices having the same scale interval Is as follows:- • Zero for digital indicating or printing devices; • Not greater than the maximum permissible error for analogue devices. (3) Autometic mode interlocks [Paragraph 3(2)(iv)] Verifythat it is not possible to make operating adjustments nor to reset the Indicating devices during an automatic weighing operation. (4) Printer Interlocks [Paragraph 3(4)} If the instrument is equipped with a printing device, verify that : (i) The principle totalization device cannot be reset to zero unless the printing device automatically records the total. Test by disabling the printer and attempting to reset the principle totalization indicator; (ii} An automatic printout of the total is generated if the automatic operation is Interrupted. (5) Battery power supply Interlocks [Paragraph 4(3){viil)} Reduce power supply voltage until the instrument ceases to operate or ceases to give a weight Indication. Verify that no malfunction or significant fault occurs before the instrument is thus put out of service. Measure and record the voltage value when the instrument ceases to operate or ceases to give a weight indication and compare this measured value with the manufacturer's specified value. 496 Tl'HE <GA.ZEff:T,E <OF .INDIA: EXTRAORDINARY [PARTII-SEC. 3(i)] (6) Retention of totaff!fterpowettfaflure![f'sragraph 4(3}(vii)J · Switch off power, to the.Jnstturnent -while the principle totelizatlonodevke is, indicating a· •total of not less than •min:,,Verlfy.that:this•total •is retained for at least 24 hours. (7) Zero offset interlockrtparag1qph 3(2J(vi)J (i) Positive offset Set thesnstrurnentto zero by the method used for,the:.tests .in ,Paragraph 6(1)(ii) and 6q)(iil)·of<this1Annex.Add a load to the loai:heceptonof:> ,!'It,for instruments with an·automaticzero-setting device, or > 0.5 ,d,t,,for ,instruments without an automatic zero-setting device. Confirm that automatic operation is no longer possible. (ii) Negstillt!,offset Add a :load ,to the load receptor of > dt for instruments with an automatic zero­ settlng·delllce, or> 0.5 dt for instruments without an automatic zero-setting device. Set the lr1Strument to zero by the method used for the tests in paragraph 6(1)(ii) and 6(1)(iil) of this annex. Remove the test weights and confirm that automatic operation Is no longer possible. 8. Influence factor and disturbance tests (1) General It is generally not possible to apply the influence factors or disturbances to an instrument which is processing material automatically. The instrument shall therefore be subjected to the influence factors or disturbances under static conditions or simulated operation as defined herein. The minimum requirements for simulators are listed under the test equipment heading for each test. The permissible effects of the influence factors or disturbances, under these conditions, are specified for each case. Where It Is possible to conduct the tests on a complete instrument under normal operation then this is the preferred option. After each test the instrument shall be allowed to recover sufficiently before the following test. The operational status of the instrument or simulator shall be recorded for each test. Simulators shall be defined in terms of hardware and functionality by reference to the instrument under test, and by any other documentation necessary to ensure reproducible test conditions and this Information shall be attached to or traceable from the test report. (2) Simulator requirements (I) General Simulators shall be designed to enable verification of the accuracy of the weighing function an the Integrity of the totalization storage and indicating function. The automatic process control and data processing functions should be verified where possible. Where possible the simulator should Include all electronic elements of the weighing and weight processing system. It should also include the load cell and a means to apply standard test loads. Where this is not possible, e.g. for high ca pa city instruments, then a load 'cell simulator may be used or alternatively the load cell interface may be modified to Incorporate a scaling factor to give the design output for a small test load. Repeatability and stability of a load cell simulator should make it possible to determine the performance of the Instrument with at least the same accuracy as and when the instrument Is tested with weights. (ii) Weighing function The weighing function may be verified by observation of the control indicating device, if available, during application of the influence factors or disturbances. Alternativelythe totallzation indicator may be observed while the total is being incremented by continually adding the result of weighing a static load during application of the Influence factors or disturbances. This may be achieved by special test software or by manual intervention or combinations thereof. Other methods which enable the weighing function to be verified may be used as appropriate. The maximum permissible errors, in terms of mass, will be the same regardless of the method used. (iii) Totalization storage and indication function The simulator must display a recorded total of not less than the minimum totalized load, •min. It must be ·verified that the recorded total is retained during and after application of influence factors or disturbances. Transient errors that are ['WT l[-¥J;s J(i)J 49 (i) Static temperature lnftuence factor mpe(*) (ii) Damp heat, steady Influence factor mpe Number of test cycles : state Weighing test : {Iii) Mains power supply Influence factor mpe voltage variation (AC) (iv) Battery power supply Influence factor mpe voltage vartation (DC) TABLE4 Environmental phenomena Test specification Specified high temper, ture; Specified low tempera ture; 0 A temperature of 5 C; Reference temperature c 20°C At least one cycle. Adjust the EUT as clos, to zero indication a practicable prior to th, test ( if an automatl: zero-tracking device i: connected, adjust it to , value near zero). Thi EUT shall not b1 readjusted at any tlrm during the test. The EUT shall display , recorded total not tes: than the minimurr to ta Iized load, Lmin. After stabilization at th, reference temperature and again at eacr specified temperature, apply at least ftve different test loads 01 simulated loads anc record: (a) date and time; (b) temperature; (c) relative humidity; (d) test load; (e) indications (as appll­ cable); (f) errors; (g) functional performance. Maximum allowable All functions shall operate variations : as designed. All errors shall be within the maximum permissible errors specified in Table 2. (ii)Damp heat, steady state [paragraph 4(3){iii)J Damp heat, steady state tests are carried out accordingto basic standard according to Table s given below:- Sixteen hours. Normal power supplied and "on" for a time period equal to or greater than the warm-up time specified by the manufacturer. Power is to be "on" for the duration of test. Two hours at each temperature under "free air" conditions. As specified in paragraph 2(7)(i) . Reference temperature of 0 20 C; Characteristic Conditions applied under test Test record and temporary failure of indication when disturbances are applied are acceptable. (3) Influence factor tests SUMMARY OF TESTS Temperature Reference of 20°C Specified high for 2 hours Specified low for 2 hours 5°C Reference of20°C (') mpe : maximum permissible error (i)Static temperature tests [Paragraph 2(7)(i)] Static temperature tests are carried out according to Table 4. To verify compliance with the provisions in paragraph 2(7)(1) under conditions of dry heat (non condensing) and cold. Test procedures In brief: Object of the test : SUPPLEMENTARY INFORMATION TO THE TEST PROCEDURES Precondition : Condition of the EUT : Stabilization : Temperature : . , Temperature sequence : 498 .THE :GAZETTE OF INDIA : EXTRAORDINARY [PART11_:_SEC.3(i)] SUPPLEMENTARY INFORMATION TO THE TEST PROCEDURES Dampheat,steadystateUpper .limit tern- , perature and relative humidity of .,,., 85'%for2 days (48 hours) TABLES Environmental phenomena Object of the test.: Precondition : Condition of the fUT : Test specification To verify -compllance with the provisions in paragraph 4(3}(iii) under conditions bf high humidity and constant temperature. None required. Normal power supplied and "on" for a time period equal to or greater than the warm-up time specified by the manufacturer. Power Is to be "on" for the duration of the test. Adjust the EUT as close to zero indication as practicable prior to the test (if an automatic zero­ tracking device is connected, adjust it to a value near zero). The EUT shall not be readjusted at any time during the test. The EUT shall display a recorded total not less than the rrurumum totallzed load, ?min· The handling of the EUT shall be such that no condensation of Stabilization : Temperature : Relative humidity : Temperature-humidity sequence: Number of test cycles : Weighingtest and ,test sequence: water occurs on the ElJT. Three hours at reference. temperature and 50% humidity . Two days (48 hours) at the upper limit temperature as specified In paragraph 2(7)(1). Reference tern· 0 perature of 20 C and at the upper limit as specified in paragraph 2(7)(1). 50% at reference temperature. 85% at upper limit temperature. Reference temp· erature of 20°C at 50% humidity. The upper limit temperature at 85% humidity; Reference tem­ perature of 20°Cat . 50% humidity. At least one cycle. After stabilization of EUT at reference temperature and 50% humidity, apply at least five different test loads or simulated loads and record : (a) date and time; (b) temperature; (c) r e I a t i v e humidity; (d) test load; (e) indications (as applicable); (f) errors; (g) functional performance. Increase the temperature in the ===============c,;;1:+:,,. .. ,.'.i\!,·,0,-._,,,.j,.j,, . .,._?,,?---· - ... ,.::..:::.:.. •.• _J.::.L,::::r.Ji ...... ,_£ __ £ __ -···- ·-- t: ['ll'T l]-1g11s 3(i)] 499 SUPPLEMENTARY INFORMATION TO THE TEST PROCEDURES (Iii) Mains power supply voltage variation (AC} [paragraph 2(7)(11)] Power voltage variation tests are carried out according to Table 6 given below :- Object of the test : To verify compliance with the provisions in paragraph 2(7)(ii) under conditions of voltage variations. Test procedures In brief: chamber to the upper limit and increase the relative humidity to 85%. Maintain the EUT at no load for a period of two days (48 hours). Following the two days, apply at least five test loads and record the data as indicated above. Allow full recover of the EUT before any other tests are performed. Maximum allowable variations: All errors shall be within the maximum per- missible errors specified in Table 2 Power is to be "on" for the duration of the test. Adjust the EUT as close to zero indication as practicable prior to the test. If it has an automatic zero-setting function then the Instrument should be set to zero after applying each level of voltage. The EUT shall display a recorded total not less than the minimum totalized load, *min. At least one cycle. The EUT shall be tested at no load and with one test load or simulated load between 50% and maximum capacity of the EUT. Stabilize the power supply at the reference voltage within the defined limits and record. (a) date and time; (b) temperature; (c) r e I a t i v e humidity; (d) power supply voltage; (e) test loads; (f) Indications (as applicable); (g) errors; (h) f u n ct i o n a I performance. Repeat the test weighing for each of the voltages (nothing the need in certain cases to repeat the test weighing at both ends of the voltage range) and record the indications. Number of test cycles : Weighing test : Test sequence : Test specification Reference voltage Reference voltage Reference voltage +10°/o Reference voltage ? 15°/o None required. Normal power supplied and "on" for a time period equal to or greater than the wanm­ up time specified by the manufacturer. TABLE 6 Environmental phenomena Voltage variation Precondition : Condition of the EUT : ------·- ·---- I ___J_?-- --- ---------------- 500 ''THE•.GAZETPE "0F IINDIA: EXTRAORDINARY [PARTIF-SEC. 3(i)] None required. Variable DC power source; calibrated voltmeter; Load cell simulator, if · applicable. Normal power supplied and "on" for a time period equal to or greater than the warm· up time specified by the manufacturer. Adjust the EUT as close to zero indication as practicable prior to the test. If it has an automatic zero-setting function as part of the automatic weighing process, then the instrument should be set to zero after applying each level of voltage. Stabilize the power supply at nominal battery voltage ±2% and record the following data at no load and with one load or simulated load between 50% and maximum capacity of the EUT: (a) date andnrne: (b) temperature; (c) relative humidity; (d) power supply voltage; (e) test load; (f) indications (as applicable); (g) errors; (h) functional per· formance. Reduce the power supply to the EUT until the equipment clearly ceases to function and Condition of the EUT : Test sequence : Conduct of the test : Precondition : Test equipment : Supply voltage : lower limit, the voltage at which the EUT clearly ceases to function (or is automatically put out of service) +2%ofthis voltage. At least one cycle. ,All .functions :shall operate as.designed. ,oAII .errors shall .be .within .the maximum permissible -errors .specfiedm Table 2. Maximum allowabJe variations : (Iv) Battery powersupply .voltage variation {DC) [{)i1ragraph2(1)(/li)] Test method : 'Yariation in DC power supply. Where the EUT continues to operate 'below the stated battery voltage, the following test shall be conducted using an equivalent variable DC power source. To verify compliance with the provisions in paragraph 2(7)(iii) under conditions of varying DC power supply. The requirements shall be met either by use of an equivalent variable DC · power source or by allowing the battery voltage to fall by use. No reference -to international standards can be given at the present time. The test consists of subjecting the EUT to DC power variations when the former is operating under normal atmospheric · conditions with one test load or simulated load between 50% and maximum capacity of the EUT. Object of the test:: Reference to standard : Test procedures In brief : Number of test cycles : Test severity :' [ '111l!. Il-<',lls 3 ( i)] 501 TABLE 7 None required. Normal power supplied and "on" for a time period equal to or greater than the warm­ up time specified by the manufacturer. Adjust the EUT as close to zero indication as practicable prior to the test. The EUT shall not be readjusted at any time during the test except to reset if a significant fault has been indicated. At least one cycle. Stabilize all factors at nominal reference conditions. Apply one load or simulated load between 50% and maximum capacity of the EUT and record : s.(a) date and time; (b) temperature; (c) relative humidity; (d) power supply voltage; (e) test load; (f) indications (as applicable); (g) errors; These mains voltage . interruptions shall be repeated ten times with a time interval of at least 10 seconds SUPPLEMENTARY INFORMATION TO THE TEST PROCEDURES Object of the test To verify compliance with the provisions in paragraph 4(1)(ii) .under conditions of short time mains voltage interruptions and reductions. Test procedures in brief: Precondition : Condition of the EUT : Number of test cycles : Weighing test and test sequence: sf sf(*) sf Conditions applied Test specification Interruption from reference voltage to zero voltage for one half cycle. Interruption from reference voltage to 50% of reference voltage for two half cycles Disturbance transients/burst Test Characteristic under test Maximum allowable variations : note the voltage. Switch the EUT "off" an increase the· power supply voltage to nominal battery voltage ±2%. Switch the EUT "on" and reduce the power supply voltage to the above noted voltage (out of service voltage) +2% of the noted voltage. Record the data indicate above. All functions shall operated as designed. All errors shall be within the maximum permissible errors specified in Table 2. (4) Disturbance tests [paragraph 4(1)(11)and 4(3)(iv)] SUMMARY OF TESTS immunity (iii) Electrostatic discharge (iv) Electromagnetic Disturbance sf Susceptibility (*)sf: value of the significant fault [see paragraph 4(2)(v) of Part I] (i) Voltage dips and short interruptions Short time power reduction (voltage dips and short interruptions) tests are carried out according to Table 7 given below :- Environmental phenomena Voltage dips and short Interruptions · (I) Voltage dips and Disturbance short interruptions (ii) Electrical fast Disturbance 502 · THECGAZElffE OF :INDIA: EXTRAORDINARY [PART11-SEc. 3(i)] Fast transient common mode 0.5 kV (peak) 5/50 ns T 1ff h 5 kHz rep. frequency Note: Applicable only to ports or Interfacing with cables whose total length may exceed 3m according to the manufacturers' functional specification. Electrical fast transients/burst immunity tests are carried out for 2 minutes with a positive polarity and for 2 minutes with a negative polarity and according to Tables 8.1, 8.2 and 8.3 given below:-- TABLE 8.1 PORTS FOR SIGNAL LINES AND CONTROL LINES None required. Normal power supplied and "on" for a time period equal to or greater than the warm­ up time specified by the manufacturer. · Adjust the EUT as close to zero indication as practicable prior to the test. The EUT shall not be readjusted at any time during the test except to reset if a significant fault has been indicated. Before any test stabilize the EUT under constant environ­ mental conditions. Stabilize all factors at nominal reference · conditions. Apply one To verify compliance with the provisions in paragraph 4(1)(ii) under conditions where fast transients are superimposed on the mains voltage. Stabilization : Weighing test : Test procedures in brief: Precond ltion : Condition of the EUT : Object of the test : TABLE 8.2 INPUT AND OUTPUT DC POWER PORTS Note : Not applicable to battery operated appliances that cannot be connected to the mains while in use. Environmental phenomena Test speaticstion A coupling/decoupling network shall be applied for testing AC power ports. SUPPLEMENTARY INFORMATION TO THE TEST PROCEDURES TABLE 8.3 INPUT AND OUTPUT AC POWER PORTS Environmental phenomena Test specification Fast transient common mode 0.5 kV (peak) 5/50 ns T 1ffh 5 kHz rep. frequency Fast transient common mode 0.5 kV (peak) 5/50 ns T 1ff h 5 kHz rep. frequency Test specificationEnvironmental phenomena ''(h)ffunctronal .per- formance. Interrupt the .power supply to zero voltage fora-period-equal to .. one, half .cvcle and -conduct .the test. . During -tnterruptton observe -the .effect on .the EUT an record as .approprtate, Reduce the power .supplv to 50% of -nomlnal voltage for a .perlod equal to two half cycles and conduct the test. During reductions observe the effect on the EUT and record, as appropriate. The difference between the weight indicatlon due to the _disturbance and the indication without the disturbance and the indication without the disturbance either shall not exceed the values given in paragraph 4(2)(v) of part I, or the EUT shall detect and act upon a significant fault. (ii) Electrical fast transients/burst immunity Maximum allowable variations : ["!T'T11-= 3(i)] 503 Electrostatic discharge tests are carried out as given in Table 9 given below :- TABLE 9 load or simulated load between 50% and maximum capacity of the EUT and record the following with and without the transients :- To verify compliance with the provisions in paragraph 4(1)(ii) under conditions where electrostatic dis­ charges are applied. Object of the test : Test procedures in brief: Precondition : Condition of the EUT : Stabilization : SUPPLEMENTARY INFORMATION TO THE TEST PROCEDURES Weighing test : None required. Normal power supplied and "on" for a time period equal to or greater than the warm­ up time specified by the manufacturer. Adjust the EUT as close to zero indication as practicable prior to the test. The EUT shall not be readjusted at any time during the test except to reset if a significant fault has been indicated. Before any test stabilize the EUT under constant environ­ mental conditions. Stabilize all factors at nominal reference conditions. Apply one load or simulated load between 50% and maximum capacity of the EUT and record the following with and without electrostatic discharge : (a) date and time; (b) temperature; (c) relative humidity; (d) test load; (e) indications (as applicable); (f) errors; (g) functional per­ formance. Maximum allowable variations: The difference between the weight indication due to the (a) date and time; (b) temperature; (c) relative humi- dity; (d) test load; (e) indications (as applicable); (f) errors; (g) functional per; formance. Test specification 8 kV air discharge 6 kV contact discharge The difference between the weight indication due to the disturbance and the indication without· the disturbance either shall not exceed the value given in Paragraph 4(2)(v) of part I or the instrument shall detect and act upon a significant fault. (iii)Electrostatic discharge Maximum allowable variations : Environmental phenomena Electrostatic discharge Note : The 6 kV contact discharge shall be applied to accessible conductive parts. Metallic contacts e.g. in battery compartments or In socket outlets are excluded from this requirement. Contact discharge is the preferred test method. 20 discharges (10 with positive and 10 with negative polarity) shall be applied on each accessible metal part of the enclosure. The time interval between successive discharges shall be at least 10 seconds. In the case of a non-conductive enclosure, discharges shall be applied on the horizontal or vertical coupling planes. Air discharges shall be used where contact discharges cannot be applied. Tests with other (lower) voltages than those given in Table 9 are not required. 504 THE iGAZEJT,E OF 'INDIA: EXTRAORDINARY [PART!l--SEC. 3(i)] Test severities : - disturbance and the indication without the disturbance either shall not ,exceed the value given in paragraph 4(2)(.v)ofPart I or the instrumentshall detect and act upon a significant fault. 9, Span stab/1/ty;test[paragraph 4( 4)(iii)J SUMMARY OF TEST Test Characteristic .unoe: test Condition applied Span stability Stability 1/2 absolute mpe (*) (*) mpe : maximum permissible error on initial verification in paragraph 2(2)(ii). Table 2. Note: the maximum permissible error for the zero point shall also be taken into consideration. Test method : Span stability. Object of test: To verify compliance with the provisions in paragraph 4(4)(iii) after the EUT has been subjected to the performance tests. Reference to standard : No reference to international standards can be given at the present time. Test procedures in brief : The test consists of observing the variations of the error of the EUT or simulator under sufficiently constant ambient conditions (reasonable constant conditions in a normal laboratory environment) at various intervals : before, du ring, and after the EUT has been subjected to perform­ ance tests. The performance tests shall include the temperature test and, if applicable, the damp _ heat test; an endurance test shall not be included. Other per­ formance tests listed in this Annex may be performed. The EUT shall be disconnected twice from the mains power supply ( or battery supply where fitted) for at least eight hours during the period of the test. The number of disconnections may be increased if so specified by the manufacturer or at the discretion of the approval authority in the absence of any specification. In the conduct of this test, the operating instructions for the instrument as supplied by the manufacturer shall be considered. The EUT shall be stabilized at sufficiently constant ambient conditions after switch­ on for at least five hours, and at least sixteen hours after the temperature and damp heat tests have been performed. Test duration : Twenty eight days or the time period necessary to conduct the performance tests, whichever is less. Time (t) between tests (days) : 0.5 st s 10. Test load : near maximum capacity (Max); the same test weights shall be used throughout the test. Maximum allowable variations :The variation in the errors of indication shall not exceed half the absolute value of the ['WT 11-= 3(i)] 505 Precondition : Test sequence : Test equipment : Condition of the EUT : scale interval on the load receptor. Note the indication at zero (!0). Either by use of an indicator with a suitable higher resolution scale interval or using the change point weight method specified In paragraph 4(2)(ii) of this Annex (noting the total addition change point weight • L0) determine and record the initial zero error (Eo), 2. Determine the error at near Max capacity (EL) Carefully remove the change point weights (if used) and apply the test load (or simulated load) and note the indication (IL)· Either by use of an indicator with a suitable higher resolution scale interval or using the change point weight method specified in paragraph 4(2)(ii) of this Annex (nothing the total addition change point weight ti. L) determine and record the error at near Max capacity (EL)· Record: (a) date and time; (b) temperature; (c) barometric pressure; (d) relative humidity; (e) value of 0.1 d; (f) test load; (g) total of added change point weights at zero load •Lo; (h) total of added change maximum permissible error in paragraph 2(2)(ii) Table 2 for the test load applied on any of the n measurements. At least eight except where the difference of the results indicates a trend more than half the allowable variation specified, the measurements shall be continued until the trend comes to rest or reverses itself, or until the error exceeds the maximum allowable variation. None required. Verified mass standards or simulated load. Normal power supplied and "on" for a time period equal to or greater than the warm­ up time specified by the manufacturer. Stabilize all factors at nominal reference conditions. Adjust the EUT as close to zero as possible. Automatic zero­ tracking shall be made inoperative and automatic built-in span adjustment device shall be made operative. lnitial measurement Determine the .span error using the following method :- 1. Determine the initial zero error (E0) lf necessary disable any automatic zero­ setting or zero-tracking devices by placing a "zero weigW of for example lb times.!pe wr» t; fJ11- {2_ 7 l Number of tests (n) : 506 .THE GAZETTE OF INDIA: EXTRAORDINARY [PARTII-SEC. 3(i)] , point,welghts :at ·test load •L; (i) the following indications : • indication at zero (I0); • indication ·of test load (IL); U) calculate: • . initial zero error E0; • .error at test load (EL); ,:(k) ,change In location .and apply all necessary corrections resulting from variations of temperature, pressure, etc. between the various measure­ ments. Immediately repeat steps 1 and 2 four more times and determine and record the average value of the error for the five tests. Subsequent measurements After observing the time between measurements requirement repeat the test sequence 1 to 2 once recording the data above unless : (a) either the result is outside the maximum allowable variation; or (b) the range of the five readings of the initial measurement is more than 0.1 d, in which case continue four more times repeating steps 1 and 2 recording the data above and determine and record the average value of the error of the five tests. The measurements shall continue until there are at least 8 measurements except where the difference of the results indicates a trend more than half the allowable variation specified, the measurements shall be continued until the trend comes to rest or reverses itself, or until the error exceeds the maximum allowable variation. EIGHTH SCHEDULE SPECIFICATIONS FOR MEASURING INSTRUMENTS [See Rule 13] General requirements (a) A measuring instrument shall be of such material, design and construction as to ensure, under normal working conditions, the following requirements :- (i) accuracy is maintained, (ii) operating parts continue functioning satisfactorily, and (iii) adjustment remains reasonably permanent. (b) A measuring instrument shall not be stamped unless it is complete with all parts and attachments concerned with the operation of measurement and delivery. (c) Wherean instrument has interchangeable or reversible parts, their interchange ability or reversal shall not affect the accuracy of the instrument. (d) Every measuring instrument of fixed type shall be so installed that the viewer can readily obtain a clear and unobstructed view of the indication of measurement and delivery. (e) The design and construction of measuring instrument shall be such as would prevent, as far as possible tampering with the accuracy of the instrument either by inadvertent use or otherwise. PART I VOLUMETRIC CONTAINER FILLING MACHINES 1. Description (a) A volumetric container fillingmachine shall consist of a basin or basins, the capacity of each of which shall depend on the ['WI Il-1§!U6 3(i)] 507 1., General 4. Maximum permissible error PART II BULKMffiRS [a) This Part deals with the accuracy requirements for bulk meters used in petroleum trade. Error in excess only 0.1 per cent 0.2 per centbe low 10 litres Capacity 10 litres and above (d) The check measure shall be tested, for accuracy, against a working standard capacity measure of appropriate capacity and accuracy. (e) The procedure for testing the accuracy of volumetric container fillingmachines shall be as follows :- (i) The machine shall be filled to the full capacity. (ii) The contents of each container of the machine shall be measured with a check measure/measures and the quantity so measured will indicate whether the capacity is within or beyond the maximum permissible error. (iii) If the capacity is beyond the maximum permissible error, the container shall be adjusted until the errors are brought within the permissible limits; and the test shall be repeated until the fillingmachines give two consecutive deliveries within the maximum permissible error. 5. Sealing The volumetric container fillingmachines shall be provided by the manufacturer with a plug/plugs or stud/studs of such soft metal to receive the stamp or seal of the verifying authority, Such plug/plugs or stud/studs shall be provided in a conspicuous part of the machine and shall be made in such a manner as to prevent its removal without obliterating the seal/ seals. The adjusting device also shall be properly sealed so as to avoid any tampering of capacity. capacity of the containers, which is intended to be filled. The operation shall consist of first filling the machine to the required level and then emptying out the contents into the container or containers. (f) The walls of the basin shall be strong enough as not to cause any appreciable deflection due to the pressure of the liquid. 3, Tests (a) A volumetric container filling machine shall be tested under the actual working conditions with a suitable liquid preferably the one which the instrument is intended to deliver. (b) Before checking a volumetric container filling machine, the inside of the basin or basins and the discharge hose and pipe shall be wetted by fillingthe machine and emptying. (c) For testing volumetric container filling machines check measure of appropriate capacity shall be used. (b) The machine shall have any one or more of the following capacities :- 1, 2, 5, 10, 15, 20, SO, 100 and 200 litres. 2, General requirements (a) The design of the fillingmachine shall be such that the measured quantity shall be entirely drained out on opening of the delivery valve. (b) The basin shall be provided with adequate sight glasses, observation windows, cut­ off valve or other means indicating clearly that the basin or basins are properly filled. (c) The basin shall be provided with a suitable device such as a displacer to enable adjustment of the capacity of the basin. (d) Every flexible hose for .discharging liquid from the basin together with the rigid delivery pipe which empties itself on discharge, shall be so arranged as to provide for ready and adequate drainage of the liquid. (e) The filling machine shall be rigidly fitted on a stand. 508 THE GAZETTE OF INDIA: EXTRAORDINARY [PARTII-SEC. J(i)] (b) Bulk meters shall not have a capacity below 100 litres. 2, Definitions (a) Pressure drop- The difference between the Inlet and outlet pressures of the meter is the pressure ·required to force liquid through tne .rneter and overcome its resistance:to movement. (b) Hydraulic.slip or slippage-That quantity of liquld;whichpasses through the meter without,causing.any registration. (c) Flow:range-That portion of the meter's total:flow capacity in which it operates to meet\the required degree of accuracy in measurement. 3. Types and construction (a) Bulk meters used for measuring liquid · petroleum products shall be positive · displacement meters in which the liquid under a positive pressure head causes the measuring elements in the meter to rotate, reciprocate or otherwise move through and defined volumetric displacement before the liquid passes from the meter. This movement is interpreted through a train of gears on a register as a measure of liquid volume. (b) Meters differ widely in construction, but in general they may be divided into the following two main classes : (i) Capillary seal meter-Capillary seal meters which may either be of reciprocating, rotary or other types are sealed with a thin film of the liquid being measured and are usually characterized by a relatively low pressure-drop. {ii) Packed or mechanical seal meter­ 'Packed or mechanical seal meters' which are always of the reciprocating piston type are sealed by a suitably designed piston ring or washer to prevent 'slip' or leakage. They have a higher pressure-drop than capillary seal meters. (c) Capillaryseal meters are generally preferable for installation where gravity discharge is essential. Both 'packed' and capillary seal meters are suitable for pressure discharge. (d) Meters are usually constructed of aluminium, aluminium alloys, bronze, brass or gun metal and stainless steel or special steels for certain small components. Carbon bearings and carbon vanes are also used since they operate satisfactorily without lubrication. (e) Meters are sometimes fitted with automatically or manually operated temperature compensating devices. These devices correct the expansion or contraction of the liquid being measured with change of temperature and directly indicate the volume which the liquidwould occupy at a standard temperature. The devices are satisfactory when the liquid temperature remains substantially. constant; but when marked fiuctuations in temperature occur, they should be used for accurate measurement only when their response to temperature change is very rapid. 4. Meter Installation The installation of the bulk meter has a direct bearing upon its operation and such characteristics as the rate of flow and accuracy may be seriously affected If it is not correctly installed. It is, therefore, essential that where possible the layout be based on the follow! ng : (I) Meter;shall be protected by a strainer or filter and an air eliminator fitted as close to the inlet as possible so as to remove all particles which are injurious to the meter and which might impair its accuracy. They shall not be at a lower level. (ii) The pipe work shall be so arranged that the strainer, air separator and meter cannot be accidentally drained. (Iii) All pipe work and fittings shall be cleaned and flushed out to remove scale and foreign matter before installing the meter. (iv) The meter shall be mounted securely on a horizontal base using rubber mounting · pads to reduce shock and vibration where these are likely to occur. (v) Inlet and outlet pipe work shall not exercise strain on the meter body. Acute bends, toes and elbows shall be avoided as far as [ '11'1 Il-191'5 3(i)] 509 possible. (vi) The layout shall be so designed as to facilitate removal of the meter without unnecessarilydisturbing the pipe work and sufficient space shall be provided to allow for meter calibration, cleaning and small servicing requirements. (vii) If pipe jointing compounds are used, these shall be applied to the male parts not to female. It is vital not to allow any compound to enter the meter. (viii) The meter shall be located so that the register Is clearly readable by the operator from the control poirit. (ix) Flow control valves, when fitted, shall be installed adjacent to the outlet of the meter. If a valve is installed on the inlet side, It shall be located at a sufficient distance on the upstream side to ensure a uniform steady flow through the meter when the valve is throttled. (x) Pulsating flow, such as that caused by piston pumps, shall be avoided, if this is not possible to achieve, a surge tank or alleviator should be installed upstream of the meter( s). (xi) Meters shall not be installed on the function side of pumps. s. Tests (a) All meters shall be tested under conditions which duplicate normal operating conditions as closely as possible particularly In respect of rates of flow and the product Involved. (b) Before commencing checking of a meter, the meter shall be run for several minutes to ensure that all units are functioning smoothly. (c) For testing of meters, a proving tank shall be used. The capacity of the proving tank shall be sufficient in size to contain at least one minute's flow through the meter at its normal operating rate when used for bu!k loading. The proving tank sha!I be tested against the working standard capacity measure of appropriate capacity. (d) The procedure for testing shall be as follows ( i) After a IIconnections have been made fill the provlnq'tank once with the full quantity in order to wet all surfaces, to fill the discharge hose and to· ascertain that there are no leaks in the connection; (ii) Empty the proving tank and close the outlet va Ive after it is completely drained; (iii) Set the meter dial to zero reading; (iv) Fill the proving tank through the meter to a point where the meter dial records the capacity of the proving tank. If the meter is fitted with an automatic presetting device, set this to deliver the capacity of the proving tank; (v) Note the reading on the graduated gauge glass of the proving tank, which would show that the meter is, within or beyond the maximum permissible error; · (vi) If it is beyond the maximum permissible error, adjust the meter until the errors are brought within the permisfi__t_llelimits; (vii) Repeat steps (ii), (iii), (iv) and (v) until the meter gives two consecutive deliveries within the maximum permissible error. (viii) If the meter has been found to give accurate measure in the initial test itself, make at least one more test to check the accuracy recorded. 6. Maximum permissible error (a) The errors shall not exceed ±0.1 per cent for any quantity discharged. (b) The bulk meter shall be complete with all parts and attachments concerned with the operation of measurement and delivery. 7. Marking (a) Every bulk meter shall be conspicuously, clearly and prominently marked with the following indications :- - ?- ---- ?-- -? - 510 THE GAZE!fTE OF JND!A: EXTRAORDINARY [PART11-SEC. 3(i)) (i) registering·rapacity; ·· (ii) name or registered trade mark of the manufacturer; (iii) lderrtfflcetionnurnber; (b) The bulk meter shall :be provlded with a plate fastened in a .prorninent place to receive the markings .mentioned in (a) above and to receive the stamp of the Legal Metrology Officer's seal. 8. Sealing Every bulk meter shall be provided with a suitable sealing arrangement to receive the stamp or sea I of the verification authority. PART III. WAT£R METERS {DOMESTIC TYPE) !. General This Part applies to water meters Intended for metering potable cold water with threaded end connections and of nominal sizes upto and including 50 mm. The part applies to both wet dial and dry dial meters. 2, Terminology (i) Nominal pressure The Internal pressure, expressed in MPa corresponding to the maximum permissible working pressure. (ii) Flow rate The volume of water passing through the water meter per unit of time; the volume being expressed in litre and the time in hours, minutes or seconds. (iii) Flow delivered The total volume of water which has passed through meter in a given time. (iv) Maximum flow rate, qmex The highest flow rate at which the meter can function over limited periods without damage and without exceeding the maximum permissible errors and the maximum permissible value for loss of pressures, expressed in kl/h. (v) Nominal flow rate, On Half the maximum flow rate, Qmax; expressed in kl/h. At the nominal flow rate Qn, the meter should be able to function in normal use, I.e. in continuous and intermittent operating conditions, without exceeding the maximum permissible error. (vi) Minimum flow rate, Omin The lowest flow rate at which the meter is required to give indications within the prescribed maximum permissible error. It is determined in terms of Qn. (vii) Flow rate range The range limited by the maximum and the minimum flow rates (Qmax and Qminl·The range is divided into two zones called upper and lower zones, separated by the transitional flow rate Qt, (viii) Transitional now rate, <;\ The flow rate which divides the upper and lower regions of the flow range and the rate at which the maximum permissible errors become discontinuous. (ix) Pressure loss The pressure loss caused due to the presence. of the water meter in the pipe line. ' (x) Water Meter-Dry Dial Meter in which the counter mechanism Is isolated from water flowing through the meter. (xi) Water Meter, Wet-Dial Type Meter in which the complete counter unit is in contact with water flowing through the meter. 3. Nominal Sizes Water meters shall be of tne following nominal sizes: 15 mm, 20 mm, 25 mm, 40 mm and SO mm. The nominal size of the water meter shall be denoted by the nominal bore of its end connections. n,? - />, · • ·" • .J'. ·" • " ·n,-, 1 • "l"t"'""''"" hl,t··• ..,. ·r-·fff>· ,..f,f---t?· ? ,. ?· >··>'•· .\. ,-1,1,..,,. I ,,.,.;,_ .. jj,, r...,.....,, .. ???.: . .- .•. -•·· 1 --· ·-- L [ 'lT'1 JI 1§!U6 3( i)] 511 4. Classes of Water Meters The water meters are classified as Class A and Class B . based on the maximum verification scale interval and metrological characteristics. S. Materials and Manufacture (1) General : Water meters and their parts, especially parts coming in continuous contact with water shall be made of materials resistant to corrosion and shall be non-toxic and non-tainting. Use of dissimilar metals in contact under water shall be avoided as far as possible in order to minimize electrolytic corrosion. (2) Construction : The meters shall be constructed in such a way as to- (i) give long service and guarantee against any fraud or tampering; and (ii) conform with the provisions of these rules. (3) Body: The body shall be free from all manufacturing and processing defects, such as blow-holes and spongy structure and shall not be repaired by plugging, welding or by the addition. of materials. The internal shape of the body shall ensure smooth flow of water and easy dismantling. (4) Registration Box : The registration box of dry-dial water meters shall be provided with one or two escape holes for minimizing the accumulation of condensed water. In the case of magnetic driven type or where the registration box and cap are integral with the body, no escape hole shall be provided. (5) Cap: Where the cap and registration box are integral, the material for cap shall be the same as used for registration box. The cap shall be so designed and fixed to the registration box as to avoid entry of water and dirt. The transparent window which covers the dial shall be inserted from the inside into the cap. The protective lid shall be secured by a robust hinge or other suitable method of robust construction. Cap ring where applicable should be of the same material as of the cap. (6) For dry type water meters, the transparent window covering the dial shall be provided with a wiper on the inner side for wiping off condensed water, (7) Connections: The meter casing shall be fitted in the pipe line by means of two cylindricalnipples or tail pieces with connecting nuts which shall be provided with each meter. The internal diameter of the nipple where it connects the pipeline shall be equal to that corresponding to the nominal size of the meter. (8) Strainers : Water meters shall be provided with strainers. Strainers shall be of a material which is not susceptible to electrolytic corrosion. They shall be of corrosion resistant materials. They shall be rigid, easy to remove and clean and shall be fitted on the inlet side of the water meter. It shall be possible to remove and clean the strainer in such a way as not to permit disturbing the registration box or tampering with it. The strainer shall have a total area of holes not less than twice the area of the nominal inlet bore of the pipe to which the meter is connected. However in the case of meters provided with internal strainer, involving opening of the registration box for cleaning, an additional external strainer shall be fitted on the inlet side satisfying the above requirements. (9) Impellers and pistons: Impeller and impeller shaft assembly shall rest on a self-lubricating, lubricating with low frictional resistance. (10) Rotary or oscillating pistons in the case of semi-positive type meters shall be of non-absorbent material, such as vulcanite or ebonite. Pistons shall be accurately finished and shall operate freely. 512 THE GAZETTE OF INDIA: EXTRAORDINARY [PART11--SEC. 3(i)] (11) Impeller or Measuring-Chamber: The Impeller or measuring -chamber shall be of a corrosion resistant material and shall be rigidand shallnot change its form as a result of Internal stresses or with use. (12) Gears and pinions: Gears and pinions shall be so constructed properly and smoothly mesh with each other and shall 'be firmly fitted on their shafts. (13) Besrinqs: Impellerbearings shall be suitably ground and polished. The shape of the impeller bearing shall be such as to prevent the penetration of particles of sand and to preclude the deposit of anything in solution or suspension in water and to facilitate the washing way of such deposits by the water flow. The shafts of the gears shall revolve freely in their bearings. The length of the bearings shall ensure their effective operation. (14) Counter: The non-reversible counter shall be of the circular multi-pointer pattern with all pointers reading clockwise or straight reading cyclometer type or a combination of pointer and cyclometer. The rollers of the counters shall be made of specially suitable for the purpose and shall be self­ lubrlcating. The pointers made of suitable materials shall be soldered to the spindle. (15) Dial: The dial shall be of vitreous enamel powder coated on copper or plastics ensuring indestructible marking and good legiblllty. {16) Regulator: Every meter shall be provided with a regulator. The regulator accessible from outside shall be operated by a key without dismantling the meter and not without breaking the seal. The internal regulating device shall not be accessible from outside. (17) Location of Serial Number : The serial number of the meter shall be clearly Indicated on the screw cap or in any other suitable place. {18) Frost Protection Device: Meters liable to be damaged by frost when so ordered by the purchaser shall be protected with suitable frost protection device. 6. Indicating device (1) Indicating device shal! be able to record 9999 kl (minimum) for meter size of 15, 20, and 25 mm and 99999 kl (minimum) for size 40 and 50 mm and shall thereafter indicate zero. (2) The indicator shall allow, by simple juxtaposition of its various constituent elements, a reliable, easy and unambiguous reading of the volume of water measured, expressed in litres. The volume is indicated by one of the following systems:- (i) the position of one or more pointers or circular scales; (ii) reading of a row of in-line· consecutive digits in one or more apertures; (iii) a combination of these two systems. (3) The kilolitres and its multiples shall be indicted in black and sub-multiples of the kilolitres in red. This colour coding applies to the pointers on circulars scale type lndicflngdevices and to the drum in in-line digit indicting devices. The actual or apparent height of the digits on the drums shall not be less than 4 mm. (4) For digital indicators the visible displacement of all digits shall be upward In value. The advance of any given digital unit shall be completed while the digit of the immediately next lower value describes the last tenth of its travel. (SJ The drum showing the digits of lowest value may move continuously. The whole number of kilo-litres shall be clearly indicated. (6) Indicators with pointer shall be non­ reversible and rotate in. a clockwise direction. The value in litres for each scale division shall be expressed as !On, wherein n is a positive or ----.------------ ['WT [!?1¥& 3(i)J 513 negative whole number ?r zero, thereby establishing a system of consecutive decades, Each scale shall be elther- (i) graduated in values expressed in litres, or (ii) accompanied by a multiplying factor (x.001, x.01, x0.1, xi, xlO, xlOOO, etc.) (7) In both cases (dial and digital indicators)- (i) the unit symbol 'KILO-LITRES' shall. appear either on the dial or in the Immediate vicinity of the digital indication; (ii) fastest-moving visible graduated element, the control element, the scale Interval of which is known as the "scale interval", shall move continuously. (8) The length of scale interval shall be not less than 1 mm and not more than 5 mm. The scale shall consist- (i) either of lines of equal thickness not exceeding one quarter of the d lsta nee between the axes of two consecutive lines and differing only In length, or (Ii) of contrasting bands of a constant width equal to the length of the scale division. (9) The width of the pointer index tip shall not exceed one quarter of the distance between two scale divisions, and in no case shall it be greater than 0.5 mm. (10) Value of Scale Division (I) Value of scale interval for Class 'A' and oass 'B' meters shall be as given In Table 1. TABLE 1 VALUE OF SCALE INTERVAL Maximum Value of Scale Interval m litre (ii)AcceleratingDevice The use of an acceleration device for increasing the speed of the meter below Qm,,is prohibited. 7. Technical characteristics (1) Pressure tightness A meter shall be able to withstand constantly without defects in its functioning, leakage, seepage through the walls or permanent deformation, the continuous water pressures of (i) 1.6 MPa for 15 minutes, and (II)2 MPa for 1 minute, when tested In accordance with the procedure described In Annexure A. (2) Loss of pressure loss of pressure through the meter when determined in accordance with the procedure described in Annex. A shall not exceed 0.025 MPa at the nominal flow rate Qn and 0.1 MPa atthe maximum flow rate, Q"",' Note: Nominal flow rete.Q, shall be taken as per Table 2 and maximum flow rate Qma, as twice the nominal flow rate. (3) Temperature suitability This test shall be carried out in accordance with the procedure described in Annexure A. This test is to be carried out for Model approval only. 8. Metrological characteristics (1) Metering accuracy The maximum permissible error in the metering accuracy, when determining as per the procedure described in Annexure A shall be as under :- (i) In the lower region of flow, Qmin (inclusive) to Qt (exclusive) ± 5% (ii) In the upper region of now, Qt (inclusive) to Qmax (inclusive) ± 2% Note : Value of Qmin, Qt and Qmax for the three classes of water meters are giver, in Table 2. (2) Minimum starting now The minimum now at which the meter starts registering shall be as given in Table 2.0 1.040 2.0 50 2.0 Class B 0.2 0.2 0.5 Class A 0.2 0.5 1.0 Meter Size 15 20 25 514 THE GAZETTE OF INDIA: EXTRAORDINARY !PARTII-SEC. 3(i)] TABLE 2 NOMINAL FLOW,MINIMUM STARTING FLOW RATl:,TRANSillONAL FLOW RATE AND MAXIMUM FLOW RATE VALUES Meter Size Nominal Minimum Starting Flow Transitional Flow rate Qt Maximum Flow rate Qn rate Qmin 1/h in 1/h for Flow rate kl/h Qmax kl/h Class A ClassB Class A aess s (1) (2) (3) (4) (S) (6) (7) 15 1.5 60 30 -···-- 150 120 3 20 2.5 100 50 250 200 s 25 3:5 140 70 350 280 7 40 10 400 200 1000 800 20 50 1'5 600 300 1500 1200 30 --·-··--···· ... ____ .... _ ······-- .. ·?- ...... ___ 2 for the two classes of water meters. The test shall be carried out in accordance with the procedure described in Annexure A. (3) Tests during verification (I) Loss of pressure (ii) Metering accuracy (4) . Model approval tests In addition to all tests mentioned for verification,the following additional tests shall be carried out :- Constructional details, Pressure tightness, Life test (Accelerated Endurance test, Temperature suitability test) and temperature suitability test. It shall be carried out in accordance with the procedure described in the Annex. A. (5) After the meter has undergone the life test, they shall again be subjected to metering accuracy test and pressure tightness test and the meter shall be deemed satisfactory only when their performance fulfils the requirements. 9. Harking Each water meter shall be marked with the following information :- 9(i) Manufacturer's name or trademark, 9(ii) Nominal size of the meter, 9(iii) Direction of flow of water on both sides of the meter, 9(iv) Accuracy class, 9(v) Serial number, 9(vi) Model approval number, and 9(vii)Year of manufacture. JO. Sealing Sealing holes shall be provided with a suitable sealing arrangement to receive the seal of the verification authority and the meter shall be sealed in such a manner as to render it impossible to obtain access to the measuring unit without breaking the seals. The sealing wire shall be rust-proof. ANNEXURE 'A' FLOW TESTS J. Metering Accuracy Test (1) After preliminaryrunning and setting, allow the water to pass through the meter in such a way that flow rates corresponding to the values given In Table 2 for Qmax, Qt, Qmin and Qn are achieved. This may be accomplished by manipulating the inlet valve or outlet valve for finer adjustment. For each of the flow rate the reading on the meter(s) shall be compared with the volume collected in the measuring tank. The test shall be carried out at least at three intermediate rates, coverihg the above ranges. (2) The error shall then be computed as under:- V,-Ve Percent error= --'--?'--X 100 Ve Where Vi =Volume of water collected in the water tank, and Ve = Volume of water indicated on individual meter. Metering accuracy shall also be calculated and reported separately for the following discharges :- (i) Qmax, (ii) Qt, and (iii) Qmin Notes: 1. The metering accuracy test at Qn may be done if required by the purchaser. 2. Recording of volume of water in the meter at Qmin shall be deemed as meter complying with the 'minimum starting flow test'. , r· t,, ------· I.------- ['WT 11-= 3(i)J 515 2. Loss of Pressure Test at Qn and Qmax This test may be carried out concurrently with the metering accuracy test at Qn and Qmax· The meter shall be tested for loss of pressure within the meter at nominal flow rate Qn and maximum flow rate Qmax. The loss of pressure should not exceed 0.025 MPa and 0.1 MPa respectively at the above two stages. (For value of Qn and Qmaxl· The pressure loss within the meter may be measured with the help of manometer or differential pressure gauge or pressure gauges provided each at up-stream and down-stream. While the meter(s) are being tested for accuracy at Qn and Qmax,the readings between the up-stream and down-stream in the pressure gauges P1and P2 or manometers shall be taken for the purpose of computing the value of loss of pressure within the meter. In case one meter is being tested the difference between the pressure gauge reading of Pl and P2 or the differential pressure shown by the differential pressure gauge/manometer shall be the loss of pressure within the meter. In case loss of pressure is being measured for more than one meter at a time, the difference between the readings of P, and P2 be divided by number of meters to obtain the loss of pressure in an individual meter. This, however, shall contain the line loss(es) contributed by the connecting pieces between the two meters. For an accurate approach line loss(es) may be measured by joining the up and down-stream spacers/pipe faces together in the absence of the meter/s (carefully avoiding protrusion into the pipe bore or misalignment of the two faces), and measuring the pipe pressure loss/line losses of the measuring section for each test at appropriate flow rates. While computing loss of pressure, across 1 or N number of meters tested in series, the loss registered by spacers/pipes in line losses be subtracted from the total value of pressure loss registered by difference between the readings of pressure gauge at up-stream and down-stream to obtain the value of loss of pressure across 1 or N number of meters. 3. Pressure Tightness Test The meter(s) shall be subjected to hydrostatic continuous water pressure of- (1) 1.6 MPa for 15 minutes, and (2) 2.0 MPa for 1 minute. Note : Only when the meter has qualified for (1) above, it should be subjected for the test for (2) above. After mounting the meter( s) on the test bench, the pump or the pumping medium should be switched on to let the water flow through the meter(s) and the air is purged out of the system. The down-stream valve should then be closed. The pressure shall then start building up and should be maintained at the above value for the given time. The meter should withstand constantly the above pressure without defects in its function, leakage, seepage or permanent deformation. Note: The meter(s) may be tested individually or in series. 4. Test equipment for Temperature Suitability Test For carrying out the temperature suitability test, a container of appropriate dimensions fitted with heating elements, and temperature control device to maintain temperature at 45°C± 1°c shall be used. 5. Temperature Suitability Test As a genera I rule, at least one meter shall be put to temperature suitability test every three months and records maintained. The meter for test may be selected at random. The meter which has qualified the technical and metrological characteristics, shall be taken and placed In-tbe test equipment meant for temperature suitability test maintained at 45°C ± 1°c. It should be kept there for 10 hours. While the meter Is immersed in water dust cap or device stopping entry of water inside wet chamber of the meter be removed. After 10 hours of continuous immersion at 45°C ± ·1°C the meter shall be taken out and kept for some time in the open to acclimatize it at the ambient temperature. It shall then be rested again for flow test and pressure tightness test. They shall 'be deemed satisfactory if their performance after the. temperature suitability test satisfies the above requirements. Note : In case any material/design changes are carried out, this test shall be performed and checked for satisfactory performance before introducing the change(s) on mass scale production. 6. Test equipment for Life Test The test equipment shall consist of the following:- (a) A centrifugal pump along with regulating valves capable of delivering water at the rate of Qn through two water meters in series, (b) A suitable horizontal test bench, and (c) A pressure gauge of appropriate range. 7. Life Test (Accelerated Endurance Test) Two unopened meters in each size and class, selected at random shall be subjected to the life test every six months, in accordance with the requirements specified in Table. Note : Meter(s) may be tested individually or in series. ---------?dj ?--- -?· 516 THE GAZETTE OF INDIA : EXTRAORDINARY [PARTII-SEC. 3(i)] TABLE 1 LIFE TEST REQUIREMENTS Nominal Test Flow Type of Test No. of Duration of Period of Duration of Flow Rate Rate Interruptions Pauses Operation at Startup and Test Run Down Qn s s Kl/h (1) (2) (3) (4) (5) (6) (7) :'> 10 .Qn Dis- 100 ODO 15 15 s 0.15(Qn)* continuous with a minimum of 1 s 2Qn Continuous 100 h >10 Qn Continuous BOO h 2Qn Continuous 200h * Qn is the number equal to the value of Qn expressed in kl/h. After the meters having undergone the life test, they shall again be subjected to flow tests and pressure tightness test. They shall be deemed satisfactory if their performance after the life test satisfies the above requirements. One of the meter which has undergone the life test (preferably the one that has shown greater deterioration in Its performance under the flow test) · shall be dismantled completely and examined with a view to ensuring that there is no undue wear or distortion. Particular attention shall be paid during examination to the wear of the actuating unit comprising vane wheel or piston, the impeller and measuring chamber, bearings, gears and pistons, pivots and the gland packing. PART IV MEASURING SYSTEM FOR UQUIDSOlliER 1liAN WATER PART-1 TERMINOLOGY 1, Measuring system and its constituents (1) Meter for volumes of liquids An Instrument intended to measure continuously, memorize and display the volume of liquid passing through the measurement transducer at metering conditions. · Note: A meter includes at least a measurement transducer, a calculator (Including adjustment or correction devices if present) and an indicating device. (2) Measurement transducer A part of the meter which transforms the flow or the volume of the liquid to be measured into signals which are passed to the calculator. It may be autonomous or use an external power source. Note: For the purposes of this specification, the measurement transducer includes the flow or volume sensor. (3) Calculator A part of the meter that receives the output signals from the transducer{s) and, possibly, from associated measuring instruments, transforms them and, if appropriate, stores In memory the results until they are used. In addition, the calculator may be capable of communicating both ways with peripheral equipment. (4) Indicating device A part of the meter which displays continuously the measurement results. Note : A printing device which provides an indication at the end of the measurement is not an indicating device. (5) Ancillary device A device intended to perform a particular function, directly involved in elaborating, transmitting or displaying measurement results. ----- -------?--------- [ <ifl1 II "&Us 3 ( i) ] 517 Main ancillary devices are:­ (i) zero setting device; (ii) repeating indicating device; (iii) printing device; (Iv) memory device; (v) price Indicating device; (vi) totalizing indicating device; (vii) conversion device; (viii) pre-setting device; and (ix) self-service device. (6) Additional device A part or a device, other than an ancillary device, required to ensure correct measurement or intended to facilitate the measuring operations, or which could in any way affect the measurement. Main additional devices are:- (i) gas elimination device; (ii) gas Indicator; (iii) sight glass; (iv) filter, pump; (v) device used for the transfer point; (vi) anti-swirl device; (vii) branches or bypasses; and (viii) valves, hoses. (7) Measuring system A system which comprises the meter itself and all the ancillary devices and additional devices. (8) Pre-setting device A device which permits the selection of the quantity to be measured and which automatically stops the flow of the liquid at the end of the measurement of the selected quantity. Note: The pre-set quantity may be the volume, the mass or the related price to pay. (9) Adjustment device A device Incorporated in the meter, that only allows shifting of the error curve generally parallel to itself, with a view to bringing errors within the maximum permissible errors. (10) Associated measuring instruments Instruments connected to the calculator, the correction device or the conversion device, for measuring certain quantities which are characteristics of the llquld, with a view to making a correction or a conversion or both. (11) Correction device ( i) A device connected to or incorporated in the meter for automatically correcting the volume at metering conditions, by taking Into account the flowrate or the characteristics of the liquid to be measured (viscosity, temperature and pressure) and the pre-established calibration curves or both. (ii) The characteristics of the liquid may either be measured using associated measuring Instruments, or stored in a memory In the Instrument. (12) Conversion device (i) A device which automatically converts the volume measured at metering conditions Into a volume at base conditions, or into a mass, by taking account of the characteristics of the liquid(temperature, pressure, density, relative density ) measured using associated measuring instruments, or stored in amernorv, (Ii) The quotient of the volume at base conditlons.'or of the mass, to the volume at metering conditions Is referred to as "conversion factor". , (13) Metering conditions The conditions of the liquid of which the volume is to be measured, at the point of measurement (example: temperature and pressure of the measured liquid). (14) Bilse conditions The specified conditions to which the measured volume of liquid is converted (example: base temperature and base pressure)., Notes (I) Metering and base conditions (which refer only to the volume of liquid to be measured or indicated) should not be confused with the "rated operating conditions" and "reference conditions" which apply to influence quantities. (ii) The values chosen as base conditions should preferably be 15°C or 20°C, and 101 325 Pa. 518 THE GAZETTE OF INDIA: EXTRAORDINARY [PARTII-SEC. 3(i)] (15) Transfer point A point at which the liquid is deftnec.as being delivered or received. (16) Gas separator A device used for continuously separating, and removlng,,a?y air or gases contained in the liquid. Note : In general, devices defined from paragraphs'1(16):to 1(19) are called gas elimtnetlon-devices. (17) Gas earsaor A device .used to extract air or gases accumulated:ln.thesupply line of the meter in the form of pockets that are no more than slightly mixed with the liquid. (18) Special gas .extrector A device which., like the gas separator but under less ,stringent operating conditions, continuously separates any air or gases contained in the liquid, and which automaticallystops the flow of liquid if there is a risk of air or gases, accumulated in the form of pockets no more than slightly mixed with the liquid, entering the meter. (19) Condenser tank In pressurized liquefied gas measuring systems, a closed tank used to collect the gases contained in the liquid to be measured and to condense them before measuring. (20) Gas Indicator A device allowing easy detection of any air or gas bubbles which may be present in the liquid flow. (21) Sight glass A device for checking, before start-up and after shut-down, that all or part of the measuring system is filled completely with liquid. 2. SJJecifictypes of measuring systems (1) Fuel dispenser A measuring system intended for the refuell!ngof motor vehicles, small boats and small aircraft. (2) Measuring system on a pipeline A measuring system which in principle is installed on a fixed pipeline connecting two or more fixed tanks. ( Note : This pipeline is characterized by a flowrate of the liquid to be measured which, in general, either does not change or changes little during a prolonged period. (3) Aircraft refuelling tanker measuring system A tanker mounted measuring system intended for refuelling aircraft, supplied from a tank mounted on the vehicle. (4) Aircraft hydrant measuring system A mobile measuring system intended for refuelling aircraft, supplied from hydrant pits. (5) Blend dispenser A fuel dispenser providing mixtures of various grades of gasoline (multigrade­ dispenser) or mixtures of gasoline and lubricating oil (gasoline-oil-dispenser) through a single nozzle. (6) Self-service arrangement An arrangement that allows the customer to use a measuring system for the purpose of obtaining liquid for his own purchase. (7) Self-service device A specific device that is part of a self-service arrangement and which allows one or more measuring systems to perform in this self­ service arrangement. Note : The self-service device includes all the elements and constituents that are mendetorv so that a measuring system performs in a self-service arrangement. (8) Attended service mode An operating mode of a self-service arrangement in which the supplier Is present and controls the authorization for the delivery. Notes : (i) In attended service mode, the settlement of the transaction takes place before the customer leaves the site of the delivery. (ii) A transaction is settled when the parties interested in the transaction have made their agreement known (explicitly or implicitly) as regards the amount of the transaction. This may be a payment, signing a credit card voucher, signing a delivery order, etc. (iii) The parties interested in a transaction may be the parties ['11'1 Il-1ll"s J(i)] 519 themselves or their representatives (for example: the employee in a filling station, the driver of a truck). (iv) In attended service mode the measurement operation ends at the moment settlement of the transaction takes place. (9) Unattended service mode An operating mode of a self-service arrangement In which the self-service arrangement controls the authorization for the delivery, based on an action of the customer. Note : In unattended service mode, the end of the measurement operation is the end of the registration (printing or memorizing) of information concerning the measurement operation. (10) Pre-payment A type of payment in attended or unattended service mode requiring payment for a quantity of liquid before the delivery commences. (11) Attended post-payment (or post-payment) A type of payment in attended service mode requiring payment for the delivered quantity after the delivery but before the customer leaves the site of the delivery. (12) Unattended post-payment (or delayed payment) A type of payment in unattended service mode In which payment for the delivered quantity Is required after the delivery, but in which the transaction is not settled when the customer leaves the site, following an implicit agreement with the supplier. (13) Authorization of a measuring system An operation that brings the measuring system Into a condition suitable for the commencement of the delivery. (14) Direct selltng to the public A transaction (selling or buying) of quantities of liquids whose settlement is associated with indications provided by a measuring system, any of the parties having access to the place of measurement and one of them being a consumer. Notes: (I)The consumer can be any person. Generally the consumer is the buyer but he can also be the seller. (ii) Main measuring systems used for direct selling to the public are : fuel dispensers, measuring systems on road tankers for the transport and delivery of domestic fuel oil. 3. Metrologicaf characteristics (1) Primary indication An indication (displayed, printed or memorized) which Is subject to legal metrology control. · Note : Indications other than primary · indications are commonly referred to as secondary indications. (2) Absolute error of measurement The result of a measurement minus the (conventional} true value of the measurand. (3) Relative error The absolute error of measurement divided by the (conventional) true value of the measurand. (4) Maximum permissible errors The extreme values permitted by the specification for an error. Notes: (i) Maximum permissible errors are , stated as relative errors or absolute errors. (ii) Where the comparison of a volume (for instance: difference between a result obtained at some specified conditions and a result obtained at reference conditions) with maximum permissible error is involved then, It is obvious that it is the absolute maximum permissible error, associated with the relative maximum permissible error, which applies. (SJ Minimum measured quantity of a measuring system The smallest volume of liquid for which the measurement is metrologically acceptable for that system. (6) Minimum specified volume deviation The absolute value of the maximum permissible error for the minimum measured quantity of a measuring system. (7) Minimum specified price deviation The price to pay corresponding to the minimum specified volume deviation. 520 THE GAZETTE OF INDIA: EXTRAORDINARY [PART!I-SEC. 3(i)] (8) Repeatability error For the purposes of this Recommendation, the difference between the largestand the smallest results of successive measure­ ments of the same quantity carried out under the same conditions. (9) Intrinsic error The error of -a measuring system used under reference conditions. (10) Initial Intrinsic.error The intrlnsic·error·of a measuring system as determined .ptior to all performance tests. (11) Fault The difference between the error of indication ,and the intrinsic error of a measuring system. {12) Signlficantfautt A fault the magnitude of which is greater than the larger of these two values:- (i) one.fifth of the magnitude of the maximum permissible error for the measured volume; (II) the minimum specified volume deviation. The following are not considered to be significant faults, namely:- (1) faults arising from simultaneous and· mutually Independent causes in the measuring instrument itself or in its checking facilities; (ii) transitory faults being momentary variations in the indication, which cannot be interpreted, memorized or transmitted as a measurement result; and (iii) faults Implying the impossibility of performing any measurement. (13) Durability The capability of the measuring system to keep Its performance characteristics over a period of use. (14) Interruptible or non-interruptible measuring system A measuring system is considered as interruptible or non-Interruptible respectivelywhen the liquid flow can or, as the case may be, cannot be stopped easily and ra pldly. {15) Cyclic volume The volume of liquid corresponding to the working cycle of the measurement transducer, i.e. the sequence of movements at the end of which all the internal moving parts of this transducer return, for the first time, to their initial positions. (16) Periodic variation The maximum difference, during one working cycle, between the volume produced by the displacement of the measuring parts and the corresponding volume as shown by the Indicating device, the latter being connected without play or slip to the measuring device and in such a way that it indicates at the end of the cycle, and for this cycle, a volume equal to the cyclicvolume; this variation may be reduced In some cases by the incorporation of a suitable correction device. Note : The effect of the correction device is included when the periodic variation Is determined. (17) First element of an indicating device Element which, in an indicating device comprising several elements, carries the graduated scale with the smallest scale Interval. 4. Test conditions (1) Influence quantity A quantitywhich is not the subject of the measurement but which influences the value of the measurand or the indication of the measuring system. (2) Influence factor · An influence quantity having a value within the rated operating conditions of the measuring system, as specified in this specification. (3) Disturbance An influence quantity having a value within the limits specified but outside the specified rated operating conditions of the measuring system. Note : An influence quantity is a disturbance if for that influence quantity the rated operating conditions are not specified. (4) Rated operating conditions Conditions of use, giving the range of values of Influence quantities for which the ['ll'l Il-"l§IUG 3(i)J 521 metrological characteristics are Intended to be within the maximum permissible errors. (5) Reference conditions A set of specified values of influence factors fixed to ensure valid inter-comparison of results of measurements. (6) Petformance test A test Intended to verify whether the measuring system under test (Equipment Under Test) is capable of accomplishing its intended functions. (7) Endurance test A test intended to verify whether the meter or the measuring system is able to maintain its performance characteristics over a period of use. (8) Uncertainty of the determination of an error An estimate characterizing the range of values within which the true value of an error lies, Including components due to the standard and Its use, and components due to the verified or calibrated instrument itself. Note : Components due to a verified or calibrated meter are notably linked to the resolution of its indicating device and to the periodic variation. 5. Electronic or electrical equipment (1) Electronic device A device employing electronic sub­ assemblies and performing a specific function. Electronic devices are usually manufactured as separate units and are capable of being tested independently. Note: Electronic devices, as defined above, may be complete measuring systems or part of measuring systems, in particular such as those mentioned in paragraph 1(1) to 1(5). (2) Electronic sub-assembly A part of an electronic device, employing electronic components and having a recognizable function of its own. (3) Electronic component The smallest physical entity which uses electron or hole conduction in semi­ conductors, gases, or in a vacuum. (4) Checking facility A facility which is incorporated in a measuring system and which enables significant faults to be detected and acted upon. Note: The checkingof a transmission device aims at verifying that all the information which is transmitted [and only that information) is fullyreceived by the receiving equipment. (5) Automatic checking facility A checking facility operating without the intervention of an operator. (6) Permanent automatic checking facility (typeP) . An automatic checking facility operating during the entire measurement operation. (7) Intermittent automatic checking facility (type-I) An automatic checking facility operating at least once, either at the beginning or at the end of each measurement operation. (8) Non-automatic checking facility (type N} A checking facility which requires the intervention of an operator. (9) Power supply device A device which provides the electronic devices with the required electrical energy, using one or several sources of a.c. or d.c, PART·2 MEASURING SYSTEM FOR LIQUIDS OTHER THAN WATER 1. Field of application (1) Scope This Specification provides the metrologlcal and technical requirements applicable to dynamic measuring systems for quantities of liquids other than water subject to legal metrology controls. It also provides requirements for the approval of parts of the measuring systems (meter, etc.). In principle, this Specification applies to all measuring systems fitted with a meter as defined under paragraph 1(1) of Part 1- Terminology (continuous measurement), whatever be the measuring principle of the meters or their application, except- (!) drum meters for alcohol; (II) measuring systems for cryogenic liquids; (iii) direct mass measuring systems, the provisions of paragraph 4 shall • 522 - THE G·AZETTE OF ,IND!A: EXTRAORDINARY [PARTII-SEC. 3(i)] applyto electronic measuring-systems for alcohol and for cryqgenic liquids. This· Specification also ·applies to systems · in which volume measurements .are .converted to mass Indication. Moreover,,specific provisions could be developed for measuring systems equipped with e.q, ultrasontc or vortex .meters. It will then be appropriate,to,decide whether such meters should be included In the scope of .this ·Specification. This Specification is not intended to prevent the development of new technologies. (2) Liquids to be measured Measuring s_Y5temsthat are covered by this Specification may be used for the following liquids, namely :- (i) liquid petroleum and related products : crude oil, liquid hydrocarbons, liquefied petroleum gas (LPG), liquid fuel, lubricants, industrial oils, etc.; (ii) liquid food : dairy products (milk, cream, etc.), beer and brewer's worth, wine and musts (cider, etc.), alcoholic beverages (liquor, whisky, etc.) non-alcoholic carbonated and not carbonated beverages, Juices and concentrates, vegetable oils (Soya-bean-oil, palm-oil, etc.); (Iii) alcohol: pure ethanol (ethyl alcohol) and mixtures of only ethanol and water (except drum meters for alcohol); (iv) chemical products in liquidstate: HCI, H2S0,,ammonia water etc: and (v) other liquids: all other liquids except cold potable water and hot water; examples: distilled water and deionised water, liquids used for calibration of tanks. 2. General requirements (1) Constituents of a measuring system A meter Itself is not a measuring system. The smallest possible measuring system indudes+ {i) a meter, (ii) a transfer point, (iii) a hydraulic circuit with particular characteristics which must be taken into account, (iv) a gas elimination device, (v) a filter device, (vi) a pumping device, (vii) correction devices related to temperature, viscosity, etc. The measuring system may be provided with other ancillary and additional devices. If several meters are intended for a single measuring operation, the meters are considered to form a single measuring system. If several meters intended for separate measuring operations have common · elements (calculator, filter, gas elimination device, conversion devices, etc.) each meter is considered to form, with the common elements, a measuring system. (2) Ancillary devices ( i) Ancillary devices may be a part of the calculator or of the meter, or may be peripheral equipment, connected through an interface to the calculator. (11)In addition these devices shall bear a legend which is clearly visible to the user to indicate that they are not controlled when they display a measurement result visible to the user. Such a legend will be present on each print out likely to be made available to the consumer. (J} Field of operation (i) The field of operation of a measuring system is determined by the following characteristics, namely:- (a) minimum measured quantity, (b) measuring range limited by the minimum flowrate, Qm"' and the maximum flowrate, Qm"' (c) maximum pressure of the liquid,P ma,' (d) minimum pressure of the liquid P m1a' (e) nature of the liquid(s) to be measured and the limits of kinematic or dynamic viscosity when an indication of the nature of the liquids alone is not sufficient to characterize their viscosity, [ "lT'1 II -"&Us 3( i ) ] 523 1.0 (f) maximum temperature of the liquid, T rmix' (g) minimum temperature of the liquid, Tmtn'and (h) environmental class. (ii) The minimum measured quantity of a measuring system shall have the form 1 x 10", 2 x 10" or 5 x 10" authorized units of volume, where n Is a positive or negative whole number, or zero. The minimum measured quantity shall satisfy the conditions of use of the measuring system; except in exceptional cases, the measuring system sha II not be used for measuring quantities less than this minimum measured quantity. The minimum measured quantity of a measuring system shall be not less than the largest minimum measured quantity of any one of its constituent elements (meter(s), gas extractor(s), special gas extractor(s), etc.). However, for gas elimination devices this provision does not need to be fulfilled if it is demonstrated (Including tests) that It Is not necessary. (iii) The measuring range shall satisfy the conditions of use of the measuring system; the latter shall be designed so that the flowrate Is between the minimum flowrate and the maximum flowrate, except at the beginning and at the end of the measurement or during Interruptions. The measuring range of a measuring system shall be within the measuring range of each of its elements. Except in the case of specific provisions of certain types of measuring systems, the maximum flowrate of the. measuring system shall normally be equal to at least four times the minimum flowrate of the meter or the sum of the minimum flowrates of the meters with which it is fitted. In some particular cases the ratio may be two. (iv) A measuring system shall exclusively be used for measuring liquids having characteristics within its field of operation, as specified in the pattern approval certificate. The field of operation of a measuring system shall be within the fields of measurement of each of its constituent elements (metres, gas elimination devices). When two or more meters a re mounted in parallel in the same measuring system, the limiting flowrates (Q ... ,, Q"",)of the various metres are taken Into consideration, especially the sum of the limiting flowrates, to verify if the measuring system meets the provision above. (4) Accuracy classes Taking into consideration their field of application, measuring systems are classified into four accuracy classes according to Tablet. TABLE 1 Class Field of application 0.3 Measuring systems on pipeline [see paragraph 5.(6)] All measuring systems if not differently stated elsewhere in this table; Iii particular: • fuel dispensers for motor vehicles (other than LPG dispensers) (see paragraph 5.(1) and 5.(9)] 0.5 • measuring systems on road tankers for liquids of low viscosity [see paragraph 5.(2)] • measuring systems for the unloading of ships' tanks and rail and road tankers [see paragraph 5.(3)) • measuring systems for milk [see paragraph 5.(5)] • measuring systems for loading ships (see paragraph 5.(6)) • measuring systems for refuelling aircraft [see paragraph 5.(8)]. Measuring systems (other than LPG dispensers) for liquefied gases under pressure measured at a temperature equal to or above - 10°C [see paragraph 5.(4)] 524 . THE GAZETTE ,of INDIA: EXTRAORDINARY [PARTII-Sec. J(i)] 1.5. • LPGdisper15e!Sformotorwenides'[see paragraph S.(7)J • Measuring systems normally in class 0.3 .or 0.5 but usedfor liquids: • whose temperature is .less than - 10°c or greater than ·50°C, or • whose dynamic viscosity is higher than 1000 MPa,s, or • whose maximum volumetric flowrate Is not.higheNhan 20 L/h Measuringsystems for liquefied carbon dioxlde'[Paragraph 5(4)(x)] • Measuring systems (other than LPG dispenser} for liquefied gases under pressure measured at a temperature below - 10°c [Paragraph 5(4)] (iii) However, whatever the measured quantity may be, the magnitude of the maximum permissible error is given by the greater of the following two values: (a) absolute value of the maximum permissible error given in Table 2 or Table 3, (b) minimum specified volume deviation. For minimum measured quantities greater than or equal to two litres, the minimum specified volume deviation (Emi,lis given by the formula: Em,.; (2 Vm,,)X (A/100) (5) Maximumpermiss1ble errors (i) For volumes not smaller than two litres, and without prejudice to paragraph 2(5)(iii) the maximum permissible relative errors, positive or negative, on volume indications are specified in Table 2. TABLE 2 For volumes smaller than two litres, and without prejudice to paragraph 2.(5)(111),the maximum permissible errors, positive or negative, on volume Indications are specified in Table 3. TABLE 3 From 0.1 to 0.2 L Measured quantity V rnfn is the minimum measured quantity, A is the numerical value specified in line A of Table 2 for the relevant accuracy class. For minimum measured quantities less than two litres, the minimum specified volume deviation is twice the value specified in Table 3, and related to line A of Table 2. Note : The minimum specified volume deviation is an absolute maximum permissible error. (6) CondltlonsJor applying maximum permissible errors Provisions in this sub-clause apply to volume indications at metering conditions [see Paragraph 2(7) for converted indications]. (i) Maximum permissible errors in line A of Table 2 apply to complete measuring systems, for all liquids, all temperatures and all pressures of the liquids,and all flowrates for which the system is intended to be, or has been approved, without any adjustment between the various tests, for: (a) pattern approval, (bl initial verification in one stage or the second stage of a two-stage initial verification, (c) subsequent verifications. (ii) Explanation: An adjustment is allowed for each liquid, but in this case the pattern approval certificate provides information on where 1.0% 1.5 1.5% 1.0 1.0% 0.6% Maximum permissible errors Value fixed in Table 2, applied to 2 L Twice the value fixed in Table 2 twice the value fixed in Table 2, applied to 0.4 L quadruple the value fixed in Table 2 quadruple the value fixed in Table 2, applied to 0.1 L 0.3% 0.5 0.5% Accuracy dasses (II) 0.2% 0.3 0.3% B A Less than 0.1 L 0.2 to 0.4 L From 1 to 2 L From 0.4 to 1 L ['WI II w,,;- 3(i)] 525 but verified with another liquid. (7) Provisions for converted Indications (i) Maximum permissible errors an conversion devices When a conversion device for converting into a volume at base conditions or into a mass (including all Its components and associated measuring Instruments) is verified separately, maximum permissible errors on converted Indications due to the conversion device, positive or negative, are equal to± (A - B), A and B being the values specified in Table 2. However, the magnitude of the maximum permissible error shall not be less than the greater of the two following values:- (a) one-half scale Interval of the indicating device for converted indications, (b) half of the value corresponding to the minimum specified volume deviation. (ii) Accuracy of associated measuring instruments When verified separately, associated measuring instruments shall exhibit an accuracy at least as good as the values in Table 4. · ·· These values apply to the indications of associated measuring Instruments taken Into account for the calculation of the converted quantity (they include errors mentioned in Paragraph 2(7)(iii). the capability of the meter to measure all the liquids without particular precautions. For example, the meter may be allowed only for measuring one liquid In normal use, or an automatic device that provides an adaptation to each liquid may be necessary. When stated in the pattern approval certificate, a one-stage initial verification or the second stage of a two-stage Initial verification of a measuring system Intended to measure two or more liquids may be carried out with one liquid only or with a liquid different from the intended liquids. In this case and if necessary, the pattern approval certificate provides a smaller range or a shift for maximum permissible errors, so that Paragraph 2(6)(1) Is fulfilled by the measuring system for all intended liquids. When stated in the pattern approval certificate, the Initial verification of a meter of a measuring system intended to measure two or more liquids may be carried out with one liquidonly or with a liquid different from the Intended liquids. In this case and If necessary, the pattern approval certificate provides a smaller range or a shift for maximum permissible errors, so that Paragraph 2(6)(ii) is fulfilled by the meter for all Intended liquids. The above considerations may be extended to the case of a measuring system or a meter Intended to measure only one liquid TABLE 4 (iii) Maximum permissible errors on measuring Accuracy classes of the measuring system 0.3 0.5 1.0 1.5 Temperature +0.3°C ±0,5°C ±o.s•c ±0,5°C Pressure less than 1 MPa : ± 50 kPa between 1 and 4 MPa : ± 5% more than 4MPa: ± 200 kPa Density + 1 kg/m3 ± 1 kg/m3 ±2 kg/m3 ±2 kg/m3 Density (iii) Accuracy for calculation of characteristic quantities of the liquid When the calculating function of a conversion device Is verified separately, the maximum permissible error for the calculation of each characteristic quantity of the liquid, positive or negative, is equal to two­ fifths of the value fixed in paragraph 2(7)(ii). However, the magnitude of the maximum permissible error shall not be less than one-half scale interval of the indicating device for converted indications . • 526 THE ·GAZETTE or INDIA: EXTRAORDINARY [PARTII-SEC. 3(i)] (iv) Direct verifu:ation.of.a.converted,mass Indication When a ·conversion device is only associated with (or included in) a meter and when the converted mass Indication is verified directly by comparison to.mass standards (e.g. using a weighing machine) the maximum permissible errors (MPE) on the converted indication, positive or negativ.e, are given by the formula: MPE = ± [82 + (A - B)' ]'h where A and B are the values specified in Table 2. When a conversion device is included In a measuring system, maximum permissible errors of line A of Table · 2 apply to the converted mass ·1ndlcatlon. However, in any case, the magnltude of maximum permissible errors shall not be less than the mass corresponding to the minimum specified volume deviation. (v) Direct verification of. a converted volume indication Standards delivering directly the true value of converted volume Indications are not available for general uses. Such standards only exist for a given liquid or for very similar liquids. When such standards are available, provisions in paragraph 2(7)(1v) can be applied by analogy. (8) Maximum permissible errors on calculators Maximum permissible errors on quantities of liquid Indications applicable to calculators, positive or negative, when they are tested separately, are equal to one­ tenth of the maximum permissible error defined In line A of Table 2. However, the magnitude of the maximum permissible error shall not be less than one-half scale interval of the measuring system in which the calculator is intended to be included. (9) Indications (i) The volume indication shall be made In cubic centimetres or millilitres, in cubic decimetres or litres, or in cubic metres. The symbolor the name of the unit shall appear In the immediate vicinity of the Indication . . ' . 1·-. Mass may only be indicated in tonnes, kilograms or grams. The symbol or the name of the unit shall appear In the immediate vicinity of the indication. (ii) Measuring systems shall be provided with an indicating device giving the volume of liquid measured at metering conditions. Without prejudice to the provisions in paragraph 2(9)(iii) when a measuring system is fitted with a conversion device, it shall be fitted (in addition to the device indicating volumes at metering conditions) with a device Indicating the volume at base conditions or the mass. Provisions applicable to devices which indicate the volume at metering conditions apply to devices which indicate the volume at base conditions and by analogy to devices which indicate the mass. (iii) The use of the same display for the indications of volume at metering conditions and of volume at base conditions or of mass is authorized provided that the nature of the displayed quantity is clear and that these indications are available on request. (Iv) A measuring system may have severat devices Indicating the same quantity. Each shall meet the requirements of this specification. The scale intervals of the various indications may be different. (v) For any measured quantity relating to the same measurement, the indications provided by various devices sha II not deviate one from another by more than one scale interval or the greatest of the two scale intervals if they differ, except otherwise provided in clause 5 (see paragraph 5 (lO)(i)(c)). (vi) Subject to specific provisions for certain types of measuring systems, use of the same indicating device for the indications of several measuring systems (which then have a common indicating device) is authorized provided that one of the following conditions is met:- [ 'lT'I II - e.l11s 3 ( i ) ] 527 (a) it Is impossible to use any two of these measuring systems simultaneously, (b) the indications relating to a given measuring system are accompanied by a clear identification of that measuring system and the user may obtain the indication corresponding to any of the measuring systems concerned, using a simple command. (10) Elimination of air or gases (i) General requirements Measuring systems shall be constructed and installed so that during normal operation, neither air intake nor gas release will occur in the liquid upstream of the meter. If there is a risk that this requirement may not be met, the measuring systems shall incorporate a gas elimination device permitting the proper elimination of any air or undissolved gases which may be contained In the liquid before ft enters the meter. The gas elimination device shall be suitable for the supply conditions and be arranged in such a way that the effect due to the influence of the air or gases on the measuring result does not exceed- (a) 0.5% of the quantity measured for liquidsother than potable liquidsand for liquids of a viscosity not exceeding 1 MPa.s, (b) 1% of the quantity measured for potable liquids and for liquids of a viscosity exceeding 1 MPa.s. However, it is not necessary for this effect to be less than 1 % of the minimum measured quantity. The values specified in this paragraph apply to the gas elimination device when It Is subject to separate control, e.g. for pattern approval. In this case, they apply to the differences between: • the meter errors with air Intake or with gas, and • the meter errors without air intake or gas. (ii) Pumped flow A gas separator shall be provided when, subject to the provisions In paragraph 2(10) (iv), the pressure at the pump Inlet may, even momentarily, fall below either the atmospheric pressure or the saturated vapour pressure of the liquid. No gas elimination device is required when the pressure at the pump inlet is always greater than the atmospheric pressure and the saturated vapour pressure of the liquid, and if any gaseous fo nmation liable to have a specific effect greater than 1% of the · minimum measured quantity cannot form or enter the inlet pipe work of the meter, whatever be the conditions of use. A gas elimination device Is required when the pressure at the pump inlet is always greater than the atmospheric pressure and the saturated vapour pressure of the liquid, but gaseous formations liable to have a specific effect greater than 1% of the minimum measured quantity can occur. When applying this provision, it is necessary to consider, in particular- (a) gaseous fonmations likely to occur owing to thermal contraction during shutdown periods; if gaseous fonmation is possible, a gas extractor is required. (b) air pockets likelyto be introduced Into the pipework when the supply tank Is completely empty; in case there Is a possibility of gaseous formation, a special gas extractor isrequired, The gas elimination device shall be installed downstream of the pump or be combined with the pump. If the gas elimination device is installed below the level of the meter, a non-return valve fitted, if necessary, with a pressure limiting device shall be incorporated to prevent the pipework . between the two components from emptying. The loss of pressure caused by the flow of liquid between the gas elimination device and the meter shall be as small as possible. If the pipework upstream of the meter incorporates several high points, it may be necessary to provide one or • \! 528 THE GAZETTE OF INDIA : EXTRAORDINARY [PARTII-SEC. J(i)] more automatic or manual evacuation devices. (iii) Non-pumped flow When a meter is supplied by gravity without use of a pump, and if the pressure of the liquid in all parts of the·pipework upstream of the meter and in the meter Itself is greater than.the saturated vapourpressure of the llqu!d,and the atmospheric pressure at measuring conditions, a gas elimination device lsmotnecessarv, However, after the measuring system has been put into service, an ,arrangement is required to ensure that It remains correctly filled. If the pressure of the liquid is likely to be lower than the atmospheric pressure while remaining greater than the saturated vapour pressure, an appropriate device shall prevent entry of air into the meter. If a meter ls supplied under gas pressure, the measuring system shall be so· constructed that separation of air or gas is avoided. An appropriate device shall prevent entry of gas into the meter. In all circumstances, the pressure of the liquid between the meter and the transfer point shall be greater than the saturated vapour pressure of the liquid. (iv) Viscous liquids Since the effectiveness of gas separators and gas extractors decreases as the viscosity of the liquids increases, these devices may be dispensed with for liquids with a dynamic viscosity of more than 20 mPa.s at 20°C. In this case, It is necessary to make provisions to prevent entry of air. The pump shall be so arranged that the inlet pressure is always greater than the atmospheric pressure. If it Is not always possible to meet this condition, a device shall be provided to stop the flow of llquld automatically as soon as the Inlet pressure falls below the atmospheric pressure. A' pressure gauge shall be used to monitor this pressure. These provisions are not necessary if devices are provided which ensure that no air can enter through the Joints in the sections of the pipework under reduced pressure and if themeasurinq system is so arranged that no air or dissolved gases will be released. (v) Removal of gases The gas removal pipe of a gas elimination device shall not Include a manually controlled valve if closure of this valve prevents the operation of the gas elimination device. However, if such a closing element is required for safety reasons, it shall be possible to ensure by means of a sealing device that it remains in the open position, unless closure of the valve automatically prevents further measurement. (vi) Anti-swirl device If the supply tank of a measuring system Is normally to be completely emptied, the outlet of the tank shall be fitted with an anti-swirl device, unless the measuring system incorporates a gas separator. (vii) General provisions for gas elimination devices (a) In principle, the gas separated in a · gas elimination device is evacuated automatically. However, the . automatic operation is not necessary if a device is provided which automatically either stops or sufficiently reduces the flow of liquid , when there is a risk of air or gases · entering the meter. In the case of shutdown, no measurement shall be possible unless the air or gases are automatically or manually eliminated. (b) The operational limits of a gas elimination device are as follows:- (aa) the maximum flowrate(s) for one or more specified liquids, (bb) the maximum pressure (with no flow running) and minimum pressure (with liquid and without air intake while the pump is running at maximum flowrate) compatible with the correct operation of the gas elimination device, (cc) the minimum measured quantity for which it is designed. (viii) Special provisions applicable to gas separators ['ll'T ll-191's J{i)] 529 (a) Within the error limits specified in paragraph 2(10)(i), a gas separator fitted In a measuring system that does not Incorporate a gas Indicator as specified in paragraph 2( 11) shall ensure the elimination of air or gases mixed with the liquid to be measured under the followingtest conditions :- · (aa) without air or gases the measuring. system operates at the maximum flow rate and at the minimum pressure specified for the gas separator, (bb) then air is introduced or gases are created as long as the measuring system operates. Any proportion by volume of air or gases relative to the liquid is permitted If the gas. separator is designed for a maximum flowrate lower than or equal to 20 m'/h; It Is limited to 30% if the gas separator is designed for a maxim um flowrate higher than 20 m3/h (the volumes of air or gases are measured at atmospheric pressure in determining their percentages). The percentage is considered only when the meter is running. Furthermore, when provided, the automatic gas removal device must continue to operate correctly at the maximum pressure fixed for these gas separators. (b) Within the error limits specified in paragraph 2(10)(i), a gas separator fitted In a measuring system that Incorporates a gas indicator shall ensure the elimination of air or gases mixed with the liquid to be measured under the following conditions : (aa) without air or gases the measuring system operates at the maximum flowrate and at the minimum pressure specified for the measuring system, (bb) then air is introduced or gases are . created as long as the measuring system operates. The proportion by volume of air or gases relative to the liquid does not exceed- 20% for liquids of a viscosity not exceeding 1 MPa.s, other than potable liquids, t,71..( ?t0,1-/J?J 10% for potable liquidsand for liquids of a viscosity exceeding 1 MPa.s. · The percentages are considered only when the meter is running. When the proportion by volume of air or gases relative to the liquid.is greater than the a bovementioned percentages and when the gas separator does not meet the requirements with respect to the maximum permissibleerrors, the gas indicator must clearly reveal the presence of air or gas bubbles. (ix) Special provisions applicable to gas extractors A gas extractor or special gas extractor shall, at the maximum flowrate of the · measuring system, ensure that elimination of an air or gas pocket of a volume (measured at atmospheric pressure) at least equal to the minimum measured quantity with no resulting additional effect greater than 1 % of the minimum measured quantity. Moreover, a special gas extractor shall also be capable of separating continuously a volume of air or gas mixed with the liquid equal to 5%. of the volume of liquid delivered at the maximum flowrate without the resulting additional effect exceeding the limits fixed in paragraph 2(10)(i). Notes: (i) A special gas extractor is used mainly In measuring systems mounted on road tankers. (ii) Installing a special gas extractor is subject to feeding conditions. Therefore, no performance is required for proportions greater than 5%. {11} Gas Indicator The gas indicator shall be designed so as to provide a satisfactory indication of the presence of air or gases in the liquid. The gas Indicator shall be Installed downstream of the meter. In empty hose measuring systems, the gas Indicator may be in the form of a weir-type sight glass and may also be used as the transfer point. The gas indicator may be fitted with a bleed screw or with any other venting device when it forms ...... ._ ---------- ---- 530 THE GAZETTE OF INDIA: EXTRAORDINARY [PARTII-SEC. 3(i)] a high point of the pipe work. No pipe must be connected to the venting device .. F.low Indicating devices (e.g. spinners) may be incorporated in gas indicators provided that such devices do not prevent observation of any gaseous formations which could be present in the liquid. (12) Transfer point (i) Measuring systems shall incorporate a transfer point. This transfer pointls located downstream .of -the meter in delivery systems ,and ,upstream of the meter in recelvlr'!Qsystems. (ii) Measuring systems :may be of two types: "empty hose" systems and "full hose" systems::the term "hose" includesrigid pipe work. (a) 'Empty,hose systems are, in the case of J:lellvery equipment, measuring s}'Sl:ems in which the transfer point is 'located upstream of the delivery hose. This transfer point may be in the form of either a weir type sight glass, or a closing device combined, In each case, with a system which ensures the emptying of the delivery hose after each measuring operation. (b) Full hose systems, In the case of delivery equipment, are measuring systems in which the transfer point consists of a closing device located In the delivery line. When the delivery line has a free end, the closingdevice must be installed as close as possible . to this end. (c) In the case of receiving equipment, the same provisions apply by analogy to the reception pipe work upstream of the meter. (13) Complete fl/ling of the measuring system (i) The meter and the pipe work between the meter and the transfer point shall be kept full of liquid during measurement and during shutdown periods. When this condition is not met, especially in the case of permanent installations, the complete filling of the measuring system up to the transfer point shall be effected manually and monitored during measurement and shutdowns. To ensure complete elimination of air and gases from the measuring system, venting devices fitted with small sight glasses whenever possible shall be placed in appropriate positions. (ii) The additional effect of the pipe work between the meter and the transfer point shall not be greater than 1 % of the minimum measured quantity due to variations in .temperature, equal to-- • 10°C for exposed pipes, • 2°C for insulated or underground pipes. To calculate this additional effect the coefficient of thermal expansion for the liquid shall be rounded to 1.10-1 per degree Celsius. (iii) Subject to the provisions in paragraph 2(10)(iii), a pressure maintaining device shall, If necessary, be Installed downstream of the meter to ensure that the pressure In the gas elimination device and in the meter Is always greater than both the atmospheric pressure and the saturated vapour pressure of the liquid. (Iv) A measuring system In which the liquid could flow in the opposite direction to that of normal flow when the 'pump is stopped shall be provided with a non-return valve, fitted with a pressure limiting device, If necessary, when reversal of the fiow could result in errors greater than the minimum specified volume deviation. ' (v) In empty hose measuring systems, the pipework downstream of the meter and, If necessary, the pipework upstream of the meter shall have a high point so that all parts of the measuring system always remain full. (vi) In full hose measuring systems which are used for measuring liquids other than liquefied gases, the free end of the hose shall incorporate a device which prevents the draining of the hose during shutdown periods. r · When a closing device is installed downstream of this device, the volume of the space between them shall be as small as possible and, in all cases, be less than the minimum specified volume deviation. (vii) If the hose comprises several components, these shall be assembled either by means of a special connector which keeps the hose ['ll'1 ll 1'!U6 3(i)] 531 full,or by a connection system which is either sealed or requires the use of a special tool to be disconnected. (14}Draining (i) In empty hose measuring systems, draining of the delivery hose referred to In paragraph 2(12)(11)(a) is ensured by a venting valve. In some cases, this valve may be replaced by special devices, e.g. an auxiliary pump or a compressed gas Injector. In measuring systems Intended for minimum measured quantities of less than 10 m', these draining devices shall operate automatically. However, when it is not possible, for duly established technical or safety reasons, to deliver (or to receive) the measured volume contained in hoses of an empty hose measuring system (for example, when measuring liquefied carbon dioxide), this volume shall be smaller than or equa I to half the minimum specified volume deviation. (ii) In full hose measuring systems, particularly those Intended for measuring viscous liquids, the nozzle shall be so designed that it cannot retain a volume of liquidexceeding D.4 times the minimum specified volume deviation. (15) Variations In the internal volume of full hoses For full hoses In a measuring system provided with a hose reef, the increase in internal volume due to the change from the coiled hose position when not under pressure to the uncoiled hose position when under pressure without any flow of liquid, shall not exceed twice the minimum specified volume deviation. If the measuring system is not provided with a hose reel, the Increase In internal volume shall not exceed the minimum specified volume deviation. (16) Branches and bypasses (i) In measuring systems intended to deliver liquids, no means shall be provided by which any measured liquid can be diverted downstream of the meter. However, two or more delivery outlets may be permanently installed and operated simultaneously or alternatively provided so that any diversion of flow to other than the Intended receiving receptacle(s) cannot be readily accomplished or ls readily apparent. Such means include, tor example, physical barriers, visible valves or indications that make it clear which outlets are in operation, and explanatory signs, If necessary. For measuring systems Intended to receive liquids, such provisions apply by analogy. A manually controJJed outlet may be · available for purging or draining the . measuring system. Effective means shall be provided to prevent the passage of liquid through any such outlet during normal operation of the measuring system. (ii) In measuring systems which may operate either with an empty hose or with a full hose and which are equipped with flexible pipes, a non-return valve shall, if necessary, be incorporated in the rigid pipework, leading to the full hose immediately downstream from the selector valve. In addition, the selector valve shall not, in any position, permit connection of the discharge hose, operating as an empty hose to the pipework leading to the full hose. (iii) Any connections which may be provided for bypassing the meter shall be closed by means of blanking flanges. However, if the operating requirements make such a bypass necessary, it shall be closed either by means of a closing disc or a double closing device with a monitoring valve in between. It shall be possible to ensure closure by means of seals, or there shall be an automatic monitoring of the double block-and-bleed valve in the bypass giving an alarm signal In case of leakage in this valve. (17} Control and closing mechanisms (i) If there is a risk that the supply conditions can overload the meter, a flow limiting device shall be provided. This device shall be Installed downstream of the meter. It shall be possible to seal it. (ii) The various positions of the controls of multi-way valves shall be easily visible and located by notches, stops or other fixing devices. Deviations from this requirement are permissible when the adjacent positions of the controls form an angle of 90° or more. (18) Various provisions (i) If provided, filters shall not disturb the measuring operation. - - _J _ 532 THE GAZETTE OF INDIA: EXTRAORDINARY [PARTII-SEC. 3(i)] (ii) In the case of measuring liquid petroleum products, means for vapour recovery shall not Influence the accuracy of measurements such that the maximum permissible error is exceeded. (19) Markings (i) Each measuring system, component or sub· system for which pattern approval has been granted shall bear, placed together legibly and Indelibly either on the dial of the indicating device or on a special data plate, the following Information :- (a) pattern approval sign (b) manufacturer's identification mark or trademark (c) designation selected by the manufacturer, if appropriate (d) serial number and year of manufacture (e) characteristics as defined in paragraphs 2(3)(1), 3(1)(1)(a), 2(10){vli){b), or 3(1)(vll)(a). {f) accuracy class, if other than 0.5. Note: The Indicated characteristics should be the actual characteristics of use, if they are known when the plate Is affixed. When they are not known, the indicated characteristics are those allowed by the pattern approval certificate. However, the minimum and the maximum temperatures of the liquids shall appear on the data plate only when they differ from - 10°C and + S0°C respectively. The minimum measured quantity of the measuring system shall in all cases be clearly visible on the dial of any Indicating device visible to the user during the measurement. If several meters operate in a single system using common components, the marking required for each part of the system may be combined on a single plate. When a measuring system can be transported without being dismantled, the markings required for each component may also be combined on a single plate. (ii) Any Information, markings or diagrams specified by this Recommendation or possibly by the pattern approval certificate, shall be clearly visible on the dial of the indicating device or within proximity to it. The markings on the dial of the indicating device of a meter forming a part of a measuring system shall not contravene those on the data plate of the measuring system. (111)When volume at base conditions is Indicated, these base conditions shall be clearly mentioned In the vicinityof the result of measurement, In the form : T,= °C(orK) P, = MPa (or kPa or Pa or bar) -. (20) Sea/Ing devices and stamping plate (I) General Sealing is preferably carried out by means of lead seals. However, other types of sealing are permitted on fragile instruments · or when these seals provide sufficient integrity, electronic seals for instance. The seals shall, In all cases, be easily accessible. . Sealing should be provided on all parts of the measuring system which cannot be . materially protected in any other way against operations liable to affect the measurement accuracy. It must be prohibited to change parameters which participate In the determination of the results of measurement (parameters for correction and conversion in particular) by mJans of sealing devices. Except for direct selling to the public, it may be acceptable that the nature of the measured liquid or Its viscosity be manually entered into the calculator at the beginning of the measurement operation [see paragraph 3(1)(v)], even when this datum participates in the correction. This datum and a note explaining that this quantity has been entered manually shall then be printed at the same time as the measurement results. A plate, referred to as the stamping plate, · aimed at receiving the control marks, shall be sealed or permanently attached on a support of the measuring system. It may be combined with the data plate of the measuring system referred to in paragraph 2(19). In the case of a measuring system used for potable liquids, sealing shall be applied ['WT u-= J(i)J 533 such that the equipment may be dismantled for cleaning purposes. (ii) Electronic sealing devices (a) When access to parameters that participate in the determination of results of measurement is not protected by mechanical sealing devices, the protection shall fulfil the .fol/owingprovisions (except In cases related to the 5th paragraph of paragraph 2(20)(1):- (aa) access shall only be allowed to authorized people, e.g. by means of a code (key-word) or of a special device (hard key, etc.); the code must be changeable; access by means of only a code is not allowed In the case of direct selling to the public; (bb) It shall be possible for at least the last Intervention to be memorized; the record shall include the date and a characteristic element Identifying the authorized person making the Intervention [see (a) above]; the traceabllfty of the last Intervention shall be assured for at least two years, If It is not over-written on the occasion of a further intervention; if It Is possible to memorize more than one Intervention, and if deletion of a previous Intervention must occur to permit a new record, the oldest record shall be deleted. (b) For measuring systems with parts which may be disconnected one from another by the user and which are Interchangeable, the following provisions shall be fulfilled:- (aa) It shall not be possible to access parameters that participate in the determination of results of measurements through disconnected points unless the provisions in 2(20)(1i)(a) are fulfilled; (bb) Interposing any device which may Influence the accuracy shall be prevented by means of electronic and data processing securities or, if not possible, by mechanical means. (c) For measuring systems with parts which may be disconnected one from a nether by the user and which are not interchangeable, the provisions in 2.20.2.2 apply. Moreover, these measuring systems shall be provided with devices which do not allow them to operate If the various parts are not .assocleted according to the · manufacturer's configuration. Note: Disconnections which are not a /lowed to the user may be prevented, for example by means of a device that prevents any measurement after disconnecting and reconnecting. 3. Requirements for meters and ancillary devices of a measuring system (J) Meter The meter(s) of a measuring system shall meet the following requirements, whether or not it (they) is (are) subject to a separate pattern approval:- (!) Field of operation (a) The field of operation of a meter Is determined at least by the following characteristics:- (aa) minimum measured quantity; (bb) measuring range limited by the minimum flowrate, Qm;,•and the maximum flowrate, Q • max, (cc) maximum pressure of the liquid, p max' (dd) nature of the liquid(s) to be measured and limits of kinematic or dynamic viscosity when the indication of the nature of the liquid alone is not sufficient for characterizing its viscosity, (ee) maximum temperature of the liquid, T0.,, (ff) minimum temperature of the liquid, T nan' (b) The value of the minimum measured quantity shall be in the form 1 x 10', 2 x 10' or S x 10' authorisec units of volume, n being a positive or negative whole number, or zero. (c) In general, the ratio between the maximum and the minimum flowrate of the meter sha II be:- ( i) at least equal to ten for meters \ _ J _ I 534 THE GAZETTE OF INDIA: EXTRAORDINARY [PARTII-SEC. 3(i)] for liquids having a viscosity less · than 20 MPa.s at measurement temperature, other.than liquefied . gases, (II) at least equal to five for meters for. liquidshaving a viscosity equal to or greater than 20 MPa.s and for meters for liquefied gases. 'However, when the requirements applicable to a particular : measuring system specify a lower ,ratio for that system or lts meter, the ratio for the meter may be less than specified above, without being lower than two in application of 2.3(111). (ii) Metrological requirements (a) The maximum permissible errors for a meter, within its field of eperatlon, are equal to those specified in line B of Table 2. (b) for any quantity equal to or greater than five times the minimum measured quantity, the repeatability error of the meter shall not be higher than two-fifths of the value specified In line A of Table 2. (c) Fora given liquid within their fields of operation, meter shall present a magnitude of the difference between the initial intrinsic error and the error after the endurance test equal to or less than the value specified in line B in Table 2. ( iii) Connections between the flow sensor and the indicating device In the text, the expression "flow sensor" also means "volume sensor". The connections between the flow sensor and the indicating device shall be reliable and, for electronic devices, durable, in accordance with paragraphs 4(1)(iii) and 4(3)(11). This provision also applies to connections between primary and secondary devices for electromagnetic meters. (iv) Adjustment device Meters may be provided with an adjustment device which permits modification of the ratio between the indicated volume and the actual volume of liquid passing through the meter, by a simple command . When this adjustment device modifies this ratio in a discontinuous manner, the consecutive values of the ratio shall not differ by more than 0.0005 for meters Intended to equip measuring systems of class 0.3, and 0.001 for other meters. Adjustment by means of a bypass of the meter is prohibited. (v) Correction device Meters may be fitted with correction devices; such devices are always considered as an Integral part of the meter. The whole of the requirements which apply to the meter, in particular the maximum permissible errors specified In paragraph 3(1)(11)(a), are therefore applicable to the corrected volume (at metering conditions). In normal operation, non-corrected volume shall not be displayed. The aim of a correction device is to reduce the errors as close to zero as possible. , All the parameters which are not · measured and which are necessary for correcting shall be contained in the calculator at the beginning of the measurement operation. The correction device shall not allow the correction of a pre-estimated draft in relation to time or volume flow, for example. Associated measuring instruments shall be fitted with checking devices, as specified in paragraph 4(3)(vi). (vi) Measuring systems equipped with volumetric meters The periodic variation of a volumetric meter shall be less than half the minimum specified volume deviation. When a volumetric meter is approved separately, the pattern approval certificate shall indicate the value of its cyclic volume. ['WT ll-19Us 3(i)] 535 {vii) Measuring systems equipped with turbine meters (a} The pressure downstream of the meter shall satisfy the manufacturer's specification. The minimum pressure shall be indicated on the data plate of the meter. (b) Measuring systems equipped with turbine meters shall be fitted with flow straightening devices for preventing, as far as possible, the liquid from any possible rotation and for.regulating the flow at the inlet of the meter. These are straight pipes, or flow straighteners, or a combination of straight pipes and a flow straightener. The flow straightening device shall be placed immediately upstream of the meter and Its internal diameter shall be equal to the diameter of the inlet of the meter. The length of the necessary straight pipes and the characteristics of the flow straighteners are specified by the pattern approval of turbine meters. (c) Each turbine meter shall be followed by a straight pipe having an Internal diameter equal to the outlet diameter of the meter and a length of at least five times this diameter. (viii) Measuring systems equipped with electromagnetic meters (a) Measuring systems equipped with electromagnetic meters shall be fitted with a straight pipe upstream of the meter and with a straight pipe downstream of the meter. The upstream pipe shall have an internal diameter equal to the inlet diameter of the meter and a length of at least ten times this diameter. The downstream pipe shall have an internal diameter equal to the outlet diameter of the meter and a length of at least five times this diameter. r (b) The time necessary for determining the rnlnmurn measured quantity at maximum flow rate, must be at least twenty times the duration of one complete cycle for meters using a.c. or pulsed d.c. field excitation. (c) The maximum permissible cable length between primary and secondary devices, shall be not more Ulan 100 metres or not more than the· value L expressed In metres according to the following formula, whichever is smaller: L = (kx c)/(fx C) Where: k = 2 X 10 - 5m c is the conductivity of the liquid, in 5/m fis the field frequency during the measuring cycle, in Hz C is the effective cable capacitance per metre, in F/m (2) Indicating device (i) General provisions (a) Reading of the indications shall be precise, easy and non-ambiguous whatever position the indicating device comes to rest; if the device comprises several elements, it shall be arranged in such a way that the reading of the measured volume can be made by simple juxtaposition of the indications of the different elements. The decimal sign shall appear distinctly. (b) The scale interval of indication shall be in the form 1 x 10", 2 x 10° or 5 x 10" authorized units of volume, where n is a positive or negative whole number, or zero. (c) Non-significant scale intervals should be avoided. This does not apply to price indications. (d) The minimum specified volume deviation shall be equal to or greater than the following value:- (i) for continuous indicating devices, the volume corresponding to 2mm . 536 THE ,GAZETTE OF INDIA: EXTRAORDINARY [PARTII-SEC. 3(i)] . on the scale or to one-fifth of the scale interval (ofttie first element · for, mechenical.indicatmq devices), . whichever is greater, (Ii) .for .discontinuous indicating . device,the volume corresponding totwo scale intervals. (ii) Mechanlcal.Jndicating device (a) .when the graduation of an element : Is entirely visible, the value of one ,revolution of that element shall be 'In the form 10" authorized units of volume: this rule however, does not ·apply to the element corresponding to the maximum range of the :indicating device. (b) On an indicating device having several elements, the value of each revolution of an element whose · .graduation is entirely visible must correspond to the .scale Interval of the following element. (c) An element of the indicating device may have continuous or discontinuous movement, but when elements other than the first have only part of their scales visible through the windows, these elements shall have discontinuous movement. (d) Toe advance by one figure of any element having discontinuous movement shall occur and be completed when the preceding element passes from 9 to O. · (e) When the first element has only a part of its scale visible through a window and has a continuous movement, the. dimension of that window shall be at least equal to 1.5 times the distance between two consecutive graduated scale marks. (f) All scale marks shall have the same width, constant along the line and not exceeding one quarter of the scale spacing. The apparent scale spacing shall be equal to or greater than 2 mm. The apparent height of the figures shall be equal to or greater than 4 mm, unless otherwise specified in the requirements for particular measuring systems. (iii) Electronic indicating device Toe continuous display of volume during the period of measurement is only mandatory in the case of direct selling to the public. However, if interrupting the displayof volume interrupts the action of some checking facilities that are mandatory or necessary to ensure correct measurement, the volume passing through the meter during each interruption shall be smaller than or equal to the minimum measured quantity. (iv) Zero setting device for volume indicating device (a) A volume indicating device may be provided with a device for setting the indication to zero either by manual operation or by means of an automatic system. (b) The zero setting device shall not permit any alteration of the measurement result shown by the volume indicating device (other than bymaking the result disappear and displaying zeros). (c) Once the zeroing operation has begun it shall be impossible for the volume indicating device to show a result different from that of the measurement which has just been made, until the zeroing operation has been completed. Indicating devices on fuel dispensers and electronic measuring systems shall not be capable of being reset to zero during measurement. On other measuring systems, either this provision shall be fulfilled or a clearly visible notice shall be provided on the indicating device stating that this operation is prohibited. (d) On continuous indicating devices, the residual indication after return to zero shall not be. more than half the minimum specified volume deviation. (e) On discontinuous indicating devices, the indication after return to zero shall not _bezero without any ambiguity. (3) Price indicating device (i) A volume indicating device with aligned figures and zero setting may be / [ 'll1l II - = 3 (i ) ] 537 complemented with a price indicating device, also with aligned figures and zero setting. (Ii) The selected unit price shall be displayed by an indicating device before the start of the measurement. The unit price shall be . adjustable; changing the unit price may be carried out either directly on the measuring system or through peripheral equipment. The Indicated unit price at the start of a measurement operation shall be valid for the whole transaction. A new unit price shall only be effective at the moment a new measurement operation may start. A time of at least 5 s. shall elapse between indicating a new unit price and before the next measurement operation can start, if the unit price is set from peripheral equipment. (iii) The provisions in paragraph 3.(2) relating to volume indicating devices apply also, by analogy, to the price indicating devices. (iv) The monetary unit used, or its symbol, shall appear In the immediate vicinity of the indication. (v) The zero setting devices of the -price indicating device and of the volume indicatingdevice shall be designed in such a way that zeroing either indicating device automatically Involves zeroing the other. (vi) The minimum specified price deviation shall be greater than or equal to the following value:- ' for continuous indicating devices, the price correspondingto 2 mm on the scale or to one-fifth of the scale interval (of the first element for mechanical indicating devices), whichever is greater, • for discontinuous indicating devices, the price corresponding to two scale intervals. · However, the interval of one-flfth of the scale interval or of 2 mm in the case of the first hyphen or the scale interval in the case of the second hyphen needs not correspond to a value less than that of the smallest coin in circulation in the country in which the equipment is used. (vii) The difference between the indicated price and the price calculated from the unit price and the indicated volume shall not exceed the minimum specified price deviation. t, 7 tr '1 oJ;, - I.Ji;-' However, this difference need not be less than the smallest monetary value as defined in paragraph 3(3)(vi). · Moreover, this requirement does not apply when the unit price has been changed between two measurements. (viii) On continuous Indicating devices, the residual indication after zeroing .shall not exceed half the minim um specified price deviation. However, this indication need not be less than the smallest monetary value as defined in paragraph 3(3)(vi). · (ix) On discontinuous i?dicatingdevices, the indication after zeroing stiall be zero without any ambiguity. (4} Printing device (i) The printed scale interval shall be in the form of 1 x 10", 2 x 10" or 5 x ion authorized units of volume, n being a positive or negative whole number, or zero, and shall not be greater than the minimum specified volume deviation. The printed scale interval shall not be smaller than the smallest scale interval of the indicating devlces. ; (ii) The volume printed shall be expressed in one of the units authorized for the indication of volume. The figures, the unit used or its symbol and the decimal sign, if any, shall be printed on the ticket by the device. · · (iii) The printing device may also print information identifying the measurement such as: sequence number, date, identification of the dispenser, type of liquid, etc. If the printing device is connected to more than one measuring system, it must print the identification of the relevant system. (iv) If a printing device allows repetition of the printing before a new delivery has started, copies shall be clearly marked as such, for example by printing, "duplicate". (v) If the volume is determined by the difference between two printed values, even if one is expressed in zeros, it shall be impossible to withdraw the ticket from the prlntinq.devlce during measurement. (vi) Where .the printing device and volume indicating device each have a zeroing .538 . THE GAZETTE OF INDIA: EXTRAORDINARY [PARTII-SEC, 3(i)] , that resetting one of them to zero also resets •the other. (vii) The printing device may print, in addition to the measured quantity, either the corresponding price or this price and the unitprlce. .In the case of"direct selling to the public" · it may. also print only the price to be paid (without the volume) when it is connected to a volume Indicating device and to a price indicating device both of which are visible to the purchaser. The figures, the monetary unit used or its symbol.and the decimal sign, If any, shall be. prlnted by the device. (viii) The printed price scale Interval shall be in the form 1 x 10', 2 x 10' or 5 x 10° monetary · units; n being a positive or negative whole number, or zero; it shall not exceed the minimum specified price deviation. . However, it need not be less than the smallest monetary value specified in paragraph 3(3)(vi). (ix) If the volume indicating device Is not fitted with a price Indicating device, the difference between the printed price and the price calculated on the basis of the Indicated · volume and the unit price shall comply with .the requirements in paragraph 3(3)(vii). (x) Electronic printing devices are also subject to the requirements in paragraph 4(3)(v). (5) Memorydevice {i) Measuring systems may be fitted with a memory device to store measurement results until their use or to keep a trace of commercial transactions, providing proof in case of a · dispute. Devices used to read stored Information are considered as included In the memory devices. (ii) The medium on which data are stored must have sufficient permanency to ensure that the data are not corrupted under normal storage conditions. There shall be sufficient · memory storage for any particular application. (iii) When the storage is full, it Is permitted to · delete ·memorized data when both the · followingconditions are met: • ,data are deleted in the. same order asthe recording order and the rules .establtshed for the particular appllcatlon are respected, ••deletion is carried out after a special manual operation. (iv) Memorization shall be such that it is , Impossible in normal use to modify stored .vatues. (v)' Memory·devices shall be fitted with checking facilities according to paragraph '4(3)(v). The aim of the checking facility is . to ensure that stored data correspond to · the data provided by the calculator and that ... restored data correspond to stored data. (6)' Pre-setting device (i). The selected quantity is pre-set by . operating a device provided with scales and scale marks or a numerical device which indicates that quantity. The preset quantity . .shall be indicated before the start of the measurement. (ii) Where pre-setting Is effected by means of several controls which are independent of each other, the scale interval corresponding . to one control shall be equal to the pre· setting range of the control of the next lower order. (iii) · Pre-setting devices may be so arranged that the repetition of a selected quantity does · not require a new setting of the controls. (iv) Where it is possible to view simultaneously the figures of the display device of the pre­ setting device and those of the volume . Indicatingdevice, the former shall be clearly distinguishable from the latter. . (v): ·Indication of the selected quantity may, :during measurement, either remain unaltered or return progressively to zero. -However, for an electronic pre-setting device it is acceptable to indicate the present value on the indicating device for volume or price by means of a special operation with the restriction that this value shall be replaced by the zero indication for volume or price. before the measurement operation can start. · . (vi) In the case of a prepaid orpre-ordered delivery, the difference found under norm a I operating conditions, between' the pre-set :quantity and the quantity showri by the ·.··volume or price indicating device at the end . of'the measurement operation,.!shall not - exceed the minimum specified volume or , price deviation. -,-- ·--- ------------------.----------- ['WI ]l-1§!1ls 3(i)] 539 · (vii}The pre-set quantities and the quantities shown by the volume indicating device shall be expressed in the same unit. This unit (or its symbol) shaube marked on the pre­ setting mechanism. (viii) The scale Interval of the pre-setting device shall not be less than the scale interval of the indicating device. (ix) Pre-setting devices may incorporate a device to permit the flow of liquid to be stopped quicklywhen necessary. (x) Measuring systems with a price indicating device may also be fitted with a price pre· setting device which stops the flow of the liquid when the quantity delivered corresponds to the pre-set price. The requirements in paragraph 3(6)(1) to 3(6)(ix) apply by analogy. (7) Conversion device (i) Measuring systems may be fitted with a conversion device as defined in paragraph 1(12) of Part 1. The provisions of the paragraph 3(7) mainly apply to electronic conversion devices in which conversion calculations are made numerically by an electronic computer. Analogous provisions could apply by analogy to mechanical conversion devices. (ii) The calculation of the conversion factor shall be made according to these specifications. (iii) As a rule, the parameters which characterize the measured liquid and which intervene In the conversion formula shall be measured using associated measuring instruments. However, some of these parameters may be not measured; or associated measuring instruments may be not subject to control when their Influence on the conversion factor is negligible (less than one-tenth of the maximum permissible error as specified in paragraph 2(5)(1). For example, in many cases it is possible to make a conversion to volume in· base conditions by measuring temperature only, when pressure and density vary little. (iv) Associated measuring instruments shall comply with applicable International Recommendations and Standards. In .addition, maximum permissible errors for these instruments are those specified 'in paragraph 2(7)(11). (v) Associated measuring instruments shall be installed near the meter so as to determine therelevant quantities as they exist in the meter in a sufficiently accurate way. The changes in Indication due to the location of the measuring points shall not exceed 0.2 times the maximum permissible error for the mec1surin9 system. Subject to fulfilment of this requirement, the same associated measuring instruments may be used for making conversions ·(and corrections) for several meters. These instruments shall not affect the correct functioning of the meter(s). Note : These requirements are checked by calculation. (vi) All the parameters which are not measured and which are necessary for the conversion shall be present in the calculator at the beginning of the measurement operation. It must be possible to print or to indicate them from the calculator. For a mechanical conversion device that cannot print or indicate these values, a seal must be broken to change any setting. · (vii) ln addition to the volume at metering conditions and the volume in base conditions or the mass, which shall be displayed according to paragraph 2(9)(11) the values of other measured quantities (density, pressure, temperature) shall be accessible for each test measurement. Scale intervals for density, pressureand temperature shall be smaller than or equal to one quarter of the maximum permissible errors fixed in paragraph 2(7)(ii)' for associated measuring instruments. (8) Calculator All parameters necessary for the elaboration of indications that are subject to legal metrology control, such as unit price, calculation table, correction polynomial, etc. shall be presentin 'the calculator at the beginning of the measurement operation. ' The calculator may be provided with interfaces permitting the coupling of peripheral equipment. When .these 540 THE GAZETTE OF INDIA: EXTRAORDINARY [PARTIl?SEC. J(i)] interfaces are used, the instrument shall continue to function correctly and its metrological functions shall not be capable of being affected. · 4. Measuring systems equipped with electronic devices (1) General requirements (i) Electronic measuring systems shall be designed and manufactured such that their errors do not exceed the maximum permissible errors as defined in paragraph 2(5) under rated operating conditions. (a) Interruptible electronic measuring systems shall be designed and manufactured such that, when they are exposed to the disturbances specified in paragraph 4 of Annexure A. • either (a) significant faults do not occur, • or (b) significant faults are detected and acted upon by means of checking facilities. This provision may apply separately to: • each individual cause of significant fault and/or • each part of the measuring system. (b) Non-interruptible measuring systems shall be designed and manufactured in such a way that no significant faults occur when they a re exposed to the disturbances specified in paragraph 4 of Annexure A. (ii} It is the responsibility of the manufacturer to decide whether a given pattern of measuring system Is Interruptible or not, taking 'mto account the applicable rules. of security. However, measuring systems for direct selling to the public shall be Interruptible. When, at the time of pattern approval, it is not possible to specify the future utilization of the Instrument, the requirements in paragraph 4(1)(i)(b) apply. (iii) The requirements in paragraph 4(1)(i) shall be met durably. Forth is purpose electronic measuring systems shall be provided with the checking facilities specified in 4(3). (iv} A pattern of a measuring system is presumed to comply with the requirements In paragraph 4(1)(i} and paragraph 4(1)(iii) if it passes the inspection and tests specified in paragraph 6(1)(xi)(a) and paragraph 6(1)(xi)(b). (v) Measuring systems shall permit the retrieval of the information relating to the measured volume contained within the Instrument when a significant fault occurred and was detected by checking facilities. (2) Power supply device (I) When the flow is not interrupted during the failure of the principal power supply device, the measuring system shall be provided with an emergency power supply device to safeguard all measuring functions during that failure. (II) When the flow IS Interrupted during the failure of the principal power supply device, the provisions in paragraph 4(2)(ii) shall be met, or data contained at the moment of the failure shall be saved and displayable on an indicating device subject to legal metrology control for sufficient time to permit the conclusion of the current transaction. The absolute value of the maximum permissible error for the indicated volume in this case is increased by 5% of the minimum measured quantity. . (3) Checking facilities (I) Action of checking facilities The detection by the checking facilities of significant faults shall result in the following actions, according to the type:. (a) Checking facilities of type N: a visible or audible alarm for the attention of the operator. (b) Checking facilities of type I or P: (aa} for non-interruptible measuring systems: ['lT'T I!-? 3(i)] 541 • automatic correction of the fault, or • stopping only the faulty device when the measuring system without that device continues to comply with the regulations, or • a visible or audible alarm for the operator; this alarm shall continue until the cause of the alarm is suppressed. In addition, when the measuring system transmits data to peripheral equipment, the transmission shall be accom­ panied by a message indicating the presence of a fault. Note : The third hyphen is not applicable for the disturbances specified in Para 4 of Annexure A. In addition, the instrument may be provided with devices to estimate the amount of liquid having passed through the installation during the occurrence of the fault. The result of this estimate shall not be capable of being mistaken for a valid Indication. (bb) for Interruptible measuring systems, in particular for fuel dispensers: • automatic correction of the fault, or • stopping only the faulty device, when the measuring system without that device continues to comply with the regulations, or • stopping the flow. (ii) Checking facilities for the measurement transducer The objective of these checking facilities is to verify the presence of the transducer, its correct operation and the correctness of data transmission. (a) When the signals generated by the flow sensor are In the form of pulses, each pulse representing an elementary volume, at least security level B defined by ISO 6551 Cabled transmission of electric and/or electronic pulsed data Is required. These checking facilities shall be of type P and the checking shall occur at time intervals not exceeding the duration of the measurement of an amount of liquid equal to the minimum specifiedvolume deviation. It shall be possible during pattern approval and initial verification to check that these checking facilities function correctly: (aa) by disconnecting the transducer, or (bb) by interrupting one of the sensor's pulse generators, or (cc) by Interrupting the electrical supply of the transducer. (b) For electromagnetic meters only, where the amplitude of the signals generated by the measurement transducer is proportional to the flowrate, the following procedure may be used: A simulated signal with a shape similar to that of the measurement signai is fed into the input of the secondary device, representing a flowrate between the minimum and maximum flowrate of the meter. The checking facility shall check the primary and the secondary device. The equivalent digital value Is checked to verify that it is within predetermined limits given by the manufacturer and consistent with the maximum permissible errors. This checking facility shall be of type P or I. In the latter case, the checking shall occur at least every five minutes. Note : Following this procedure, additional checking facilities (more than two electrodes, double signal transmission etc.) are not required. (c) For other technologies checking facilities providing equivalent levels of security remain to be developed. -- - _j ·-- - ·---·-·-------- 542 THE GAZETTE OF INDIA : EXTRAORDINARY [PARTll-SEC. 3(i)] (ill) Checkingfacilities for the calculator The objective of these checking ,facilities is· to verify that the calculator .svstern 'functions correctly and to .ensure the validity of the calculations made. There .are no special •means . required for indicating.thatthese .. checking· facilities Junction ccorrectlv, (a) Tile checking of the..functioning of the-calcutatlon .svstem ·shall be of type;P. orI. .Jn 'the latter .case, the checking shall occur at teast every flve·minutes, .except 'in .the case of fJJel dispensers, for which it shall occur-at each delivery. The-Objective of:the.checking is to verify that: r(aa) the values of all ' · permanently memorized Instructions and data are "correct, by such means as- • summing up ail instructions and data codes and comparing the sum with a fixed value, • line and column parity bits (LRCand VRC), cyclic redundancy check (CRC 16), • double independent storage of data, • storage of data In "safe coding", for example protected by checksum, line and column parity bits, (bb) all procedures of internal transfer and storage of data relevant to the measure­ ment result are performed correctly, by such means as: · • write-read routine, • conversion and re- conversion of codes, • use of "safe coding" (check sum, parity bit), • double storage. (b) The checking of the validity of calculations shall be of type P. This consists of checking the correct value of all data related to the measurement whenever these data are Internally stored or transmitted to peripheral equipment through an Interface; this check may be carried out by such means as parity bit, check sum or double storage. In addition, the calculation system shall be provided with a means of controlling the continuity of the calculation program . (iv) Checking facility for the Indicating device The objective of this checking facility is to verify that the primary Indications are displayed and that they correspond to the data provided by the calculator. In addition, it aims at verifying the presence of the indicating devices, when they are removable. These · checking facilities shall either have the form as defined in paragraph 4(3)(iv)(a) or the form as defined in paragraph 4(3)(iv)(b). (a) The checking facilityof the indicating device is of type P; however, it may be of type I If a primary indication is . provided by another device of the measuring system, or if the indication may be easi!ydetermined from other primary indications (for example, In the case of a fuel dispenser It Is possible to determine the price to pay from the volume and the unit price). · Means may include, for example: (aa) for indicating devices using incandescent filaments or LEDs, measuring the current in the filaments, (bb) for indicating devices using fluorescent tubes, measuring the grid voltage, (cc) for indicating devices using electromagnetic shutters, checking the impact of each shutter, (dd) for indicating devices using multiplexed liquid crystals, output checking of the control voltage of segment lines and of common electrodes, so as to detect any disconnection or short circuit between control circuits. (b) The checking facility for the indicating device shall include type I or type P checking of the electronic circuits used for the indicatingdevice (except the driving circuits of the ['11'1 u-= 3(i)J 543 display itself); this checking shall meet the requirements in paragraph 4(3)(1)(a). It shall also provide visual checking of the entire display which shall meet the following description:- (aa) for fuel dispensers: • displaying all the elements ("eights" test) • blanking all the elements ("blank" test) • displaying "zeros" • Each step of the sequence shall last at least 0.75 second. (bb) for all other measuring systems, the test sequence as described under (a) or any other automatic test cycle which Indicates all possible states for each element of the display. This visual checking facility shall be of type I for fuel dispensers and of type N for other measuring systems, but It is not mandatory for a malfunction to result In the actions described in paragraph 4(3)(i). (c) It shall be possible during verification to determine that the checking facility of the indicating device is working, either: ·• by disconnecting all or part of the indicating device, or • by an action which simulates a failure in the display, such as using a test button. (v) Checking facilities for ancillary devices An ancillary device (repeating device, printing device, self-service device, memory device, etc.) with primary indications shall include a checking facility of type I or P. The object of this checking facility is to verify the presence of the ancillary device, when It is a necessary device, and to verify the correct transmission of data from the calculator to the ancillary device. In particular,the checking of a printing device alms at ensuring that the printing controls correspond to the data transmitted by the calculator. At least the followingshall be checked: • presence of paper, • the electronic control circuits (except the driving circuits of the printing mechanism Itself). · It shall be possible during pattern approval and other verifications to check that the checking facility of the printing device is functioning by an action. simulating a printing fault, such es using a test-button. Where the action of the,checking facility Is a warning, this shall be given on or by the ancillary device concerned. (vi) Checking facilities for the associated measuring instruments Associated measuring instruments shall include a checking facility of type P. The aim of this checkingfacilityis to ensure that the signal given by these associated Instruments is inside a pre-determined measuring range, Examples: • four wire transmission for resistive sensors, • frequency filters for density meters, • control of the driving current for 4-20 mA pressure sensors. 5. Requirements spedflc to certain types of measuring systems (1) Fuel dispensers Except where otherwise specified, 'the requirements In this sub-clause do not apply to LPG dispensers. (i) By design, the ratio between the maximum flowrate and the minimum flowrate for these systems shall be at least ten; on site, this ratio may be smaller provided that it Is not less than five. (ii) When the measuring system includes Its own pump, a gas elimination device shall . be installed, immediately upstream of th,e · meter inlet. Where a gas indicator is fitted, It shall not have a venting device as mentioned in paragraph 2(11). (iii) When the measuring system is intended for installation in a centrally pumped system, or for a remote pump, the general provisions in paragraph 2(10) shall be applied. If It is not intended to install a gas elimination device the manufacturer or 544 THE 'GAZETTE DF INDIA: EXTRAORDINARY [!'ARTII-SEC 3(i)] installer has to prove thatthere 'Is no 'risk for air Intake or gas release. In this case the minimum level in the storage tank.must be automatically securedand.any leakage shall be ·.checked \[see .also ,paragraph 2(10)(11)]. (iv) Fuel dispensers shall be .equipped with a device for resetting the volume indicating device to:zero. The minimum heiqhttorthe figures of the resettable volume.mdicetoris 10 mm. If these systems .also include a price indicatingdevke.fhts indicatingdevice shall be fitted with ·a zero resetting device. The minimum height for the price indicator remalns-4 mm [paragraph 3(2)(11)(f)]. (v) When only one nozzle can be used during a deliver,y,and after the nozzle has been replaced, the next delivery shall be inhibited until the ;Indicating device has been reset to zero. When two or more nozzles can be used simultaneously or alternately, and after the ·utilized nozzles have been replaced, the next delivery shall be inhibited until the indicating·device has been reset to zero. Moreover, by design, the provisions in the first paragraph of paragraph 2(16)(1) shall be fulfilled.' The above requirements do not apply when an auxiliary hand pump is used. (vi) Measuring systems having a maximum flowrate not greater than 3.6 m1/h shall have a minimum delivery not exceeding 5 L. (vii) When the measuring system is fitted with a ticket printing device which is subject to control, this printing device shall comply with the relevant requirements in 3.4. In addition, any printing operation shall prevent the continuation of the delivery until a reset to zero has been performed. · However, the printing operation shall not change the quantity indicated on the indicating device. (viii) fuel dispensers shall be interruptible. (ix) In addition to requirements in paragraph 4(2)(il), electronic fuel dispensers shall be such that the minimum duration of operation of the display shall be either- (a) at least 15 min continuously and automatically after the failure of the principal electrical supply, or (b) a total of at least 5 min in one or several periods controlled manually during one hour after the failure. Note : If a test during pattern approval is necessary to verify that the fuel dispenser fulfils this requirement, the instrument has to be supplied with electric power normally for the 12 hours which preceded the test. Before this supply the battery (If provided) may be unloaded. In addition, fuel dispensers shall be designed so that an interrupted delivery cannot be continued after the power supply device has been re-established if the power failure has lasted more than 15 s. · (x) Electronic fuel dispensers shall be such that the delay time between the measurement value and the corresponding indicated value shall not exceed 500 ms. Several fuel dispensers may have a common indicatingdevice if and only if the first provision in paragraph 2(9)(vi) is met. (xi) The checking of the operation of the calculator, as described in paragraph 4(3)(iii)(a}, shall be performed at least once for each delivery. (xii), It is not required to display volumes, · and prices if applicable, that correspond to a small number of scale intervals at the beginning of the delivery, and to start the display with that volume and the corresponding price. The volume thus hidden shall not be greater than two times the minimum specified volume deviation. The hidden price shall not be greater than the price corresponding to that volume. (2) Measuring systems on road tankers for the transport and delivery of liquids of low viscosity (S. 20 MPa.s) and stored at atmospheric pressure with the exception of potable liquids (i) The provisions hereafter apply to measuring systems mounted on road tankers or transportable tanks. ["IT'l 11-= 3(i)] 545 (ii) Tanks equipped with measuring systems may comprise one or more compartments. I (iii) The compartments of road tankers shall be fitted with an anti-s?1ir\ device, except when the rneasurlnq system is fitted with a gas separator which complies with paragraph 2(10)(viii). I (iv) When a tank comprises more than ' one compartment, each compart- ment shall be provided withlan individual (manual or automatic) closing device in each outlet line. (v) In conformity with natio?al­ regulations on their use, each measuring system shall be allocated to a specific product or to a raneeof products for which the meter rbeen approved. The pipework shall, as far1as possible, be designed so that products cannot become mixed in the measuring system. I (vi) Subject to the requirements in paragraph 2(16), a measufing I system mounted on a road tanker I may Include empty or full hoses or both. Where several hoses Iare intended to operate alternatively; the changing of the delivery path shall be impossible during a measurement operation. To this end, the chance of the delivery path may be lir\ked to the resetting to zero of the volume Indicating device. I (vii) The volume indicating device shall Include a zero resetting device complying with paragraph 3(2)(iv). I When the measuring system is fitted with a ticket printing device, Iany printing operation shall prevent the continuation of the delivery urltila I reset to zero has been performed, except for printing devices determining the delivered volumeby means of two consecu'tive indications. I · (viii) Measuring systems mounted on road tankers may be designed to operate by pump only, or by gravity only, or with the choice of either pump or gravity, or by gas pressure. ! ' (a) Measuring systems fed by pump only may operate either empty hose or full hose. (b) If there is a risk that the requirements in paragraph 2(10)(ii) related to the absence of air or gas cannot be compiled with, the meter shall have one of the following gas elimination devices upstream of it: • a suitable gas separator conforming to paragraph 2(10)(viii), • a special gas extractor, conforming to paragraph 2(10)(ix), • a gas extractor, conforming to paragraph 23(10)(1x). When, in a measuring system, the pressure at the outlet of the meter can be lower than the atmospheric pressure while remaining higher than the saturated vapour pressure of the measured product, the above devices shall be combined with an automatic system for slowing down and stopping the flow to prevent any air from entering the meter. When the pressure at the outlet of the meter cannot be lower than atmospheric pressure (this Is especially the case for systems operating solely full hose), the use of automatic devices for slowing down and stopping the flow Is not required. (c) The special gas extractor shall be fitted with a sight glass. (d) Measuring systems operating solely by gravity shall comply with the following requirements. (e) The equipment shall be so constructed that the total contents of the compartment(s) can be measured at a flowrate greater than or equal to the minimum flow rate of the measuring system. (f) If there are connections with the gas phase in the tank of the road 546 THE! GAZETTE OF INDIA: EXTRAORDINARY [PARTII-Sec. 3(i)] tanker, appropriate devices shall prevent any gas from entering the meter. (g) Th? requirements in paragraph 2(10)(iii) concerning non-pumped flow shall apply. A pump downstream of the transfer point for increaslnq the flowrate may be authorized if the foregoing provisions are complied with. This pump shail not cause a fall in pressure in the meter. (h) For measuring systems which include a manual release to the atmosphere immediately downstream of the transfer point, a gas indicator is mandatorv. (i) Measuring''systemscapable of being operated either by gravity or by pump shall comply with the requirements in paragraph 5(2)(viii)(a) and 5(2)(viii)(b). (j) Measuring systems operated by means of gas pressure may operate empty hose or full hose. The pipework which links the meter to the device intended to prevent any gas from entering the meter as specified in point paragraph 2(10)(iii) shall have no constriction or component likely to cause a pressure loss which could generate gas pockets by releasing the gas dissolved in the liquid. These systems shall include a pressure gauge which indicates the pressure in the tank. The dial of this gauge shall indicate the range of perrnisstble pressures. (3) Measuring systems for the unt9ading of ships' tanks and of raH and road tankers using an intermediate tank (i) Measuring systems designed to measure volumes of liquids during the unloading of ships' tanks and of rail and road tankers may include an intermediate tank in which the liquid level determines the transfer point. This intermediate tank may be designed to ensure the elimination of gas. The cross section of the intermediate tank shall be such that a volume equal to the . minimum specified volume deviation corresponds to a difference in level of at least 2 mm. ( ii) In the case of road and rail tankers, the intermediate tank shall automatically ensure a constant level, visible or detectable, at the beginning and at the end of the measurement operation. The level is considered to be constant when it settles within a range corresponding to a volume of no more than the minimum specified volume deviation. (iii) In the: case of ships' tanks, it is not necessary to provide for the automatic maintenance of a constant level. Where such a provision is not made, it shall be possible to measure the contents in the intermediate tank. If the ship's tank is unloaded by means of pumps located in the bottom of the ship, the intermediate tank may be used only at the beginning and at the end of the measurement operation. (4) Measuring systems for liquefied gases under pressure (other than LPG dispensers) (i) Only full hose measuring systems are authorized. (ii) A pressure maintaining device, located downstream of the meter, shall ensure that the product in the meter remains in a liquid state during the measurement. The necessary pressure may be maintained either at a fixed value or at a value adjusted to suit the measurement conditions. (a) When the pressure is maintained at a fixed value, this value shall be at least equal to the vapour pressure of the product at a temperature 15°C above the highest possible operating temperature. It shall be possible to protect the adjustment of the pressure maintaining device with a seal. (b) When the pressure is adjusted to suit the measurement conditions, this pressure shall exceed the vapour pressure of the liquid during the measurement by at least 100 kPa ( 1 bar). This adjustment shall be automatic. (c) For stationary measuring systems for industrial use, the competent metrology service may authorize ['1T'f II Bl"6 J(i)J 547 manually-adjustable pressure maintaining devices. The pressure at the meter outlet shall then be at least equal to the Vapour pressure of the product at a temperature 15°C above ' .:, . ··' , · · the temperature of the measurement. It is then necessary to attach a diagram to the measuring system, giving the vapour pressure of the measured product as a function of its temperature. If it is anticipated that these measuring systems may have to operate unsupervised over long periods, the temperature and pressure shall be registered continuously by means of appropriate instruments. (iii) A gas elimination device shall be fitted upstream of the meter. However, if it is demonstrated that no vapour release will occur during measurements a gas elimination device is not mandatory. This demonstration shall include tests under the worse conditions. (a) The gas separator shall comply with the general requirements in paragraph 2(10)(i), either for the liquefied gas itself or for a liquid of higher viscosity. However, because of the low viscosity of liquefied gases and due to the difficulty of control, it is accepted that when the length of the pipework linking the meter to the feed tank does not exceed 25 rn, a gas separator may be approved if its useful volume is at least equal to 1.5% of the volume delivered in one minute at maximum flowrate. When the length of this pipework exceeds 25 m, the useful volume of the gas separator shall be at least equal to 3% of the volume delivered in one minute at maximum flowrate. The gas outlet pipe of the separator may be connected to the space in the feed tank which contains the gaseous phase, or to an independent pressure maintaining device set to a pressure from 50 to 100 kPa (0.5 to 1 bar) lower than the pressure at the meter outlet. This pipe may incorporate a shut-off valve, which meets the requirements In paragraph 2(10)(v). (b) The volume of the condenser tank · depends on the volume of the ' pipework between the supply tank valve and the pressure maintain· Ing valve, downstream of the meter. The volume of this condenser tank shall be at least equal to twice the reduction In volume of the liquid which Is likely to occur between these va Ives If the temperature drops by a value conventionally fixed at 10°C for exposed pipes and 2°C for insulated or underground pipes. To calculate the contraction, the coefficient of thermal expansion shall be rounded to 3 x 10·3 per degree Celsius for propane and propylene and 2 x 10-3 per degree Celsius for butane and butadlene. For other products with a high vapour pressure, the values of the coefficient to be adopted shall be specified by the competent metrology service. The condenser tank shall be fitted with a manual blow off valve. It shall be fitted at the high point In the pipework of the measuring system of which it is part. The volume resulting from the above calculation may be divided between several condenser tanks located at high points in the pipework. (iv) A thermometer well or, when this thermometer well Is not imposed by specific professional practices, another means for measuring temperature, shall be provided close to the meter. The thermometer used shall have a scale interval not exceeding o.s•c and shall be verified. Provisions shall be made for fitting a pressure measuring device between the meter and the pressure maintaining device. This measuring 548 THE GAZETTE OF INDlA: EXTRAORDINARY [PART[I-SEC. 3(i)] device shall be available for verification. If necessary, provisions for sealing shall be made. {v) When the volume is measured using a system mounted on a road tanker, any connection between the gaseous phases of the vehicle's tank and of the receiving tank is prohibited unless it is essential for completing a measurement, in which case a non­ return valve is mandatory. For other measuring systems for liquefied gas, such connections are permitted when the volumes of gas transferred via these connections are measured by means of suitable measuring instruments. (vi) Safety valves may be incorporated in measuring systems in order to prevent abnormally high pressures. If they are located downstream of the meter, they shall open to the atmosphere or be connected to the receiving tank. In no case shall the safety valves located upstream of the meter be connected to the valves located downstream by pipes which bypass the meter. (vii) When the conditions of operation require the use of detachable hoses, these hoses shall remain full if their volumes are greater than the minimum specified volume deviation. Detachable full hoses shall be fitted with special connections for full hoses, so-called couplers or self­ sealing valves. Manually operated blow-off devices shall be provided at the ends of these hoses, if necessary. (viii) The control valve of the double closing device mentioned in paragraph 2(1'6)(iii) for pipework bypassing the meter, if provided, may be closed for safety reasons. In this case, any leakage shall be monitored by a pressure gauge located between the two shut off valves or by any other equivalent system. (ix) For measuring systems mounted on road tankers the volume indicating device and its printing device, if provided, shall comply with the requirements in paragraph 5(2)(vii). (x) The provisions in paragraph 5(4) also apply for measuring systems for liquefied carbon dioxide with the following exceptions: • only empty hose measuring system [are authorized (see paragraph 5(4)(i)], • the connection between the gaseous phases of the vehicle's tank and of the receiving tank is authorized If (i) a device is installed to allow compensation of the delivered quantity by an amount relating to the quantity of vapour returned in the gas line, or (ii) compensation is made by automatic or manual calculation. However, in both cases, flow from the delivery tank to the receiving tank by means of the gas return line shall be securely prevented [see paragraph 5(4)(v)], • the requirements of paragraph 5( 4 )(vii) are not mandatory for these systems. (5) Measuring systems for milk (i) The following requirements apply to transportable measuring systems which are mounted on road tankers and used for the collection of milk, to fixed measuring systems used for the reception of milk at the dairy, and to fixed or transportable measuring systems used for the delivery of milk. (ii) The transfer point in reception installations is defined by a constant level in a tank upstream of the meter. It must be possible to check this constant level before and after each measurement. The level shall be established automatically. (a) When the meter is fed by means of a pump, the constant level tank may be placed either upstream of the pump or between the pump and the meter. (b) If the constant level tank is placed upstream of the pump, the tank itself may be fed by gravity, by emptying milk churns, by means of an auxiliary pump or by means of a vacuum system. If the milk is introduced by means of a pump or a vacuum system, a gas ['ll'T 11-= 3(i)] 549 ellmlnatlon device is necessary. This device may be combined with the constant level tank. (c) If the constant level tank is placed between the pump and the meter, this tank shall ensure that gas is ellmlnated. (d) Notwithstanding the requirements of paragraph 2(13)(iii), the meter may be fed by means of a vacuum system. In this case, the pressure Inside the pipework connecting the constant level tank to the meter will be lower than atmospheric pressure and the tightness of the Joints of this connection must be particularly well ensured. It must be possible to check the tightness and a notice plate drawing attention to this checking shall be provided. (e) In all Installations for reception, the pipework upstream of the constant level device shall empty completely and automatically under the rated operating conditions. (f) The constant level is monitored by means of a sight glass or a level Indicating device. The level is considered to be constant when it settles within a range defined by two marks at least 15 mm apart and corresponding to a difference in volume of no more than twice the minimum specified volume deviation. (g) If, In order to meet the above condition, devices for reducing the flowrate are incorporated in the measuring system, the flowrate during the period of reduced flowrate shall be at least equal to the minimum flowrate of the meter. (h) If, In a reception installation at a dairy, the measured llquid flows to a level lower than that of the meter, a device shall automatically ensure that the pressure at the outlet of the meter remains above atmospheric pressure. (i) If a volume of liquid is required to fill the measuring system prior to the first measurement, It shall be indicated on the data plate of the measuring system so that it can be taken into account, by calculation, in the first measurement of a reception period. The first volume measured by the measuring system during a reception period shall be equal to or greater than the volume which Is necessary for the complete filling of the measuring system. (iii) Measuring systems used for delivery shall comply with the general requirements in clause 2 and with those In clause 3. (iv) Notwithstanding the general requirements In paragraph 2(10) concerning the elimination of air or gases, the gas elimination devices shall comply with the requirements in paragraph 2( 10)(1) solely under the conditions of use, i.e. with entry of air at the beginning and end of each measuring operation of delivery. The mounting of delivery installations shall be such that the pressure of the liquid at the level of the joint to the supply tank Is always greater than atmospheric pressure. (v) The volume indicating device of a transportable measuring system and Its printing device, if provided, shall comply with the requirements in paragraph 5(2)(vii). (6) Measuring systems on pipeline and systems for loading ships (i) The ratio between the maximum flowrate and the minimum flowrate of the meter of the measuring system may be less than the value specified In the relevant paragraph in paragraph 3(1)(i)(c). In this case, the measuring system shall be fitted with an automatic checking device to verify that the flowrate of the liquid to be measured is within the restricted measuring range of the measuring system. This checking device shall be of type P and shall meet the requirements in paragraph 4(3)(i}(b). The maximum and minimum flowrates may be determined in relation to the liquid to be measured and manually introduced into the calculator. (ii) Prevention of gas flow The measuring system shall be provided with a means of eliminating any air or gas contained in the liquid unless the entry of air Into the liquid or release of gas from 550 THE GAZETTE OF INDIA: EXTRAORDINARY [PARTII-SEC. 3(i)] the liquid is prevented by the configuration of the pipework or by the arrangement and operation of the pump(s). (iii) Special conditions of installation Reserve flow of the liquid to·be measured in the measuring.system shall be prevented by a suitable device, unless otherwise approved.· (iv) Sampling.device The measuring system may include a sampllng·device:intended to determine the propertles.ot-the liquid to·be measured. It is not necessary to take into account the volume of the sample in the results of the measurement If this sample is less than 0.1 times themaximum permissible error of the measurlryg system. (v) Testing devices Measuring systems in pipelines should be provided with devices allowing verification of the systems in situ. However, this principle may be waived provided that: • the meters are verified on a control test station with liquids having the same characteristics as those to be measured at the place of installation. The verification is carried out on the measurement transducer only, associated with a compatible and equivalent indicating device, provided that all the elements having a direct mechanical link with the measurement transducer and being able to influence the. measurement are verified at the same time, • the meters benefiting from this exemption shall be subject to periodic calibration controlled and fixed by the metrology service, and • to complete the verification, the measuring systems concerned shall be subjected to a qualitative check of function and installation, In situ. Subject to this exemption, the measuring systems shall be constructed so that a standard of appropriate size can be fitted for testing the meters. When a test can only be earned out with the pumps running, which normally does not allow for testing with the meter stopped at the start and at ;,. the end of the test, the standard shall be suitable for continuous operation (for example, volume standard with a flow diverting mechanism, pipe prover etc.), Moreover, these capacities shall represent at least 10,000 scale intervals of the indicating device of the meter to be verified or of the auxiliary Indicating device used for the test or 10,000 electrical pulses of the measurement transducer. However, a lower capacity may be permitted if a visual or automatic interpolation allows one to ascertain the indication of the meter with an error. smaller than or equal to one per ten thousand of this capacity. Furthermore, it shall be possible to carry out a metrological test of the associated measuring instruments which may be Incorporated and which aim at measuring density, viscosity, pressure and temperature, under actual operating conditions. (1) Fuel dispensers for liquefied gases under pressure (LPG dispensers) (i) Requirements in paragraph S(l){i), S(l)(iv)) and 5{l)(vii) to S{l)(xii) are applicable to LPG dispensers for motor vehicles. However, the ratio between the maximum flowrate and the minimum flowrate shall be at least five by design. (ii) Requirements in paragraph S(4)(i), 5(4)(11), 5(4)(ii)(a}, 5(4)(ii)(b), 5(4)(iii), 5{4){ili)(a) and ?(4)(iii)(b) are applicable to LPG dlspehsers for motor vehicles. (iii) The manufacturer or the owner of the measuring system shall provide a thermometer well or an equivalent means for measuring the temperature close to the meter. The thermometer used shall have a scale interval not exceeding 0.5°C and shall be verified. (iv) Connection between the gas phases of the feed tank and of the vehicle's tank Is prohibited. (v) When only one nozzle can be used during a delivery, and after the nozzle has been replaced, the next delivery shall be inhibited until the indicating device has been reset to zero. When two or more nozzles can be used simultaneously or alternately, and after the utilized nozzles have been replaced, the next delivery shall be inhibited until the Indicating device has been reset to zero. ["ll'T II-? 3(i)] 551 Moreover, by design, the provisions in the first paragraph of 2(16)(i) shall be fulfilled. Moreover, in both cases, when the flow is stopped by emergency means and a predetermined delay is exceeded, the current delivery shall be stopped and the next delivery shall be preceded by a reset to zero. (vi) A non-return valve, located between the gas ellmlnatlon device and the meter, is mandatory. The pressure loss caused by it shall be sufficiently low to be considered neg IlgIble. (vii) Hoses shall be fitted with special connections for full hoses, so-called couplers or self-sealing valves. (viii) Safety features shall not affect the metrologlcal performance. (ix) When the measuring system is provided with a conversion device, it shall be possible to verify separately the indications of volume at measuring conditions and associated measuring instruments. (x) Closing valves in vapour return lines shall automatically result in stopping the delivery or preventing the start of the next delivery, unless these valves have been sealed in the open position. (xi) The construction of the nozzle shall be such that, at the moment of coupling or uncoupling, the loss of liquid does not exceed the minimum specified volume deviation. (8) Measuring systems intended for the refuelling of aircraft . The requirements of this sub-clause also apply to the refuellingof helicopters. (i) General {a) Measurlng.§ystems Intended for refuelflng aircraft. are full hose measuring systems: (b) The gas elimination device function may be performed by a rnicrofilter water elimination device provided that provisions in paragraph 2(10) are fulfilled. · (c) They shall be interruptible measuring · systems. (ii) Stationary measuring systems (a) The requirements applicable to fuel dispensers apply to stationary measuring systems intended for the refuelling of aircraft, except those in paragraph 5(1)(1). (b) These systems may include their own pumps or be designed for installation in a centrally pumped system. (c) The micro.filter-water elimination device shall be fitted upstream of the gas elimination device when these devices are separate one from another. (iii} Mobile measuring systems (a) General (b} If more than one transfer point is provided, interlocks should prevent the usage of two or more together unless the arrangement is such that it would be difficult to use them on different aircrafts at the same time. (c) They may be designed for defuelllng aircraft provided that the connecting point for defuelling is located upstream of the gas elimination device. A weir-type sight glass is not mandatory. Interlocks may also be necessary to prevent bypassing metered liquid through the return line back to the supply tank while delivering fuel to the aircraft. (d) Where the microfilter-water elimination device may be used to perform the function of the gas elimination device, it may be verified by an examination of documents only if provisions In paragraph 2(10) are fulfilled. (e) Each installation shall be provided with or accompanied by- • instructions for use, • a liquid circulation plan, • a description of necessary operations for use, • a description of control and connecting devices positions related to their use. (f) Aircraft refuelling tanker measuring systems / 552 'THE GAZETTE OF INDIA: EXTRAORDINARY [PART II-SEC. 3(i)J rhe -requtrements.tn-peraqraphs 5(2)(il), 5(2)(iii), 5(2)(1v),.5(2)(vi), 5(2)(vii) and 5(2)(viii)(a) apply. Note: For qcodprectice-mthe use of the. system, when the .aircraft refuelling tanker· measuring system Is flttedwith a device used to.perform the,gas·extractor or special gas extractor 'function, a :manometer should be.provided upstream of the pump· ln.order.to detect.depressions when .thev .occur, Us ,Indications should .be easily 11Jslble by the operator, (g) Alrcraft,hydrant measuring systems (h) "fhe.gas elimination device may be ,a,.devlce performing the function of ,a ;as extractor when the under­ .gr.ound pipe- • :ts designed for easy elimination ,cf the air contained In the pipe with appropriate devices, • ls fitted with special connecting devices for full hoses, • ls supplied so that, in designed supply conditions, no gaseous formation can occur or enter the underground pipe. ( i) When the aircraft hydrant measuring system is equipped with a device for froth recovery and re-Injection, it shall be located upstream of the gas elimination device and It shall not permit permanent introduction of gas Into the meter. (j) Depressurization valves for the hoses so that connection and disconnection can be easily made, shall be accompanied with interlocks to prevent metered liquid from being diverted. (9) Blend dispensers (i) The requirements in paragraph 5(1)(1) to S(l)(lv) and S(l)(vi) to S(l)(xll) are applicable to both parts of the multigrade­ dispenserand to the gasoline part of the gasoline-oil-dispenser. However, by design, the ratio between the maximum flowrate and the minimum fiowrate may be at least five in the case of multigrade-dispensers. (ii) When only one nozzle can be used during a delivery, and after the nozzle has been replaced, the next delivery shall be inhibited until the indicating device has been reset to zero. When two or more nozzles can be used simultaneously or alternately, and when the utilized nozzles have been replaced, the next delivery shall be Inhibited until the Indicating device has been reset to zero. Moreover, by design, the provisions in the first paragraph of paragraph 2(16)(i) shall be fulfilled. (iii) The requirements In paragraph 5(9)(1v) through paragraph 5(9)(vfli)do not apply if the designations of the various mixtures do not allow conclusions to be drawn concerning the ratio of volumes of the two components. Examples for such designations: • number of stars (2, 3, 4 starts), • octane-number (92, 95, 98 octane), • two-stroke-mixture (without designation such as 5%). Moreover, the requirement In paragraph 5(9)(Jv) or 5(9)(v) only applies where the measuring system provides the Indication of the mixed volume and the price of the mixture depends on the blending ratio. It does not apply where the measuring system provides- • an Indication of the mixed volume and the price does not depend on the blending ratio, or • a volume indication for each component of the mixture and does not provide an indication of the mixed volume. To permit compliance with the requirement In paragraph 5(9)(iv) or paragraph 5(9)(v) to be verified, It is necessary- • for multigrade-dispensers to measure the volumes of both components, • for gasoline-oil-dispensers to measure either the volumes of oil and gasoline or the volumes of oil and mixture, • for both types to make the separate collection of both components feasible durl?g verification. (Iv) The accuracy of the blending ratio for multlgrade-dispensers shall be as follows:- ['11'111-= 3(i)] 553 The designations of the various mixtures being Indicated as the ratio of volumes of the two components (for example 1:1), the real ratio of the volumes of two components shall be w_lthinthe limits of ±5%, I.e. the real ratio k..,, = V ,IV1 of volumes of both components determined during the verification shall be equal to the nominal (indicated) ratio k.om,within the limits: km,,= k_ -0. 05 k,,.mand ?" = k,,m+ o. 05 koom Examples: Designation 3:1 J:J 1:3 Knom 0.333 1.00 3.00 Km1, 0.316 0.95 2.85 K .. , 0.350 1.05 3.15 (v) The accuracy of the blending ratio for gasollne-oll·dispensers shall be as follows:- If VI Is the volume of the minority component in the mixture and v, the volume of the majority component, the real volumetric ratio related to the minority component, expressed as a percentage [T = 100 x V/(V,+V,)l,shall be equal to the nominal ratio within a limit of plus or minus: • 5% in relative value, • O. 2% absolute, whichever is greater. In other words, T being the real volumetric ratio as a percentage, and T00mthe nominal volumetric ratio as a percentage, the following must be satisfied:- 1T - TnomI IT oom ? 0.05. if the nominal volumetric ratio is at least 4%, and I T-Tnom I .s 0.02%. if the nominal volumetric ratio Is less than 4 per cent. (vi) If the blend dispenser is capable of delivering more than one mixture with the same nozzle, the installation of two hoses and a special blending device close to the transfer point Is required. If the blend dispenser can deliver only one . mixture per nozzle, the blendingdevice may be installed inside the dispenser, using a single hose per nozzle. (vii) If the blend dispenser Is capable of delivering one or both singlecomponents (in addition to the mixtures) with a common nozzle, a device shall prevent the liquid flow through the unused part of the blend device. (viii) The lubricating oil part of a gasoline-oil· dispenser shall be designed so as to prevent air bubbles in the oil passing through the oil measuring device. There shall also be a device to detect the presence of oil. In the absence of oil, delivery has to be stopped by means, e.g. of: • an intermediate oil reservoir and a device which stops the delivery when the oll reservoir is empty, , a pressure detecting device which stops the delivery in the case of an oil pressure drop. (10) Self-service arrangement with fuel dispensers The following requirements apply to measuring systems covered by paragraph 5(1), 5(7) or 5(9) when fitted with self-service arrangements. (i) General requirements (a) Marking, sealing and connection of the components are left to appropriate authority approving the pattern .. (b) Where ttie self-service device serves two or more dispensers, each dispenser shall be provided with a dispenser identification number that shall accompany any primary indication provided by the self­ service device. (c) The primary indications on indicating devices and printing devices of the self-service arrangement shall not indicate any mutual differences. The scale intervals of the primary indication on Indicating devices and the printing devices and memory devices of the self-service arrangement shall be the same. (d) Printing devices on the self-service arrangement shall not reproduce the indications of a dispenser as the difference between two printed values. (e) Indication of information that is not subject to metrological control is allowed, provided that it cannot be I ---?--#----?--- 554 THE GAZETTE OF INDIA: EXTRAORDINARY [PARTII-Sec. 3(i)] confused with metrological information. (f) The control device of:the self-service device should be capable of Indicating the status of the dispensers (e.g. running, authorized or unauthorized)that are connected to the self-service device and in the case ·of multi pie modes of service and/or .type of payment also that particular status -of the measuring system, (g) 'A change of the type of payment ·and/or rnode of operation shall not be effective before the end of the ·current measurement operation. (h) The self-service arrangement, .includingprovisions related to clearly defined methods of operation, shall be such that at least one primary Indication for the benefit of the customer must be available at least up to the settlement of the transaction to enable the delivered quantity and the price to pay to be checked. · (i) In the case of a self-service arrangement that totallzes the delivered volumes for different registered customers over the course of time, the minimum measured quantity is not affected by the scale Interval used for such totallzations. (ii) Attended service mode If the dispenser indicating device provides the only primary indication, provisions shall be made to Inform the customer that the next authorization of a particular dispenser can only be given by the supplier after settlement of the current transaction. (a) Attended post-payment (b) Where the self-service arrangement includes a device that provides an additional primary Indication (additional to those of the indicating device of the dispenser), it shall consist of at least one installation for the reproduction of the volume and/ or the price indicated by the dispenser indicating device, consisting of- • a printing device for the issue of a receipt of the customer, or • an Indicating device for the benefit of the supplier together with a display for the benefit of the customer. Note: As a consequence of paragraph 3(4)(vli), the reproduction of the volume and price is necessary when the dispenser can be authorized before the settlement of the transaction. (c) For self-service devices with temporary storage (temporary storage mode) of measurement data of dispensers the following requirements apply:- (a) temporary storage of measurement data shall be restricted to one delivery for each dispenser, (b) the primary indication shall be accompanied by a clear mark representing the sequence. For example, the number 1 or 2 or the letter A or B, (c) when a primary indication of the self-service device is out of service, the self-service arrangement may continue its operation provided that it no longer uses any temporary storage, and that the dispenser indicating device remains the primary indication, (d) where the mandatory primary indication for the benefit of the customer Is provided by a device in the form of a separate constructional unit and this unit becomes uncoupled, or if the checking facilities detect a malfunction, the temporary storage mode shall be prohibited and the dispenser indicating device remains the primary indication, (e) pre-payment in attended service mode, (f) the requirements of paragraph 3(6) are applicable, (g) a printed or hand-written receipt of the pre-paid amount shall be provided. ['lT'l I[ ? 3(i)J 555 (iii) Unattended service mode (a) General (b} The self-service arrangement shall provide additional primary indica­ tions by means of- • a printing device for the issue of a receipt of the customer, and • a device (printing or memory device) on which measurement data are registered for the benefit of the supplier. (c) When the printing devices or memory device, as required by paragraph 5(10)(iii)(b), are not able to provide any indication or become unserviceable, the customer shall be clearly warned by automatic means before the operation commences. Passing from attended to unattended service mode shall not be possible before correct operation of the . arrangement is concluded as feasible by the checking facilities, Including compliance with the above provision. (d) Where the self-service arrangement Is used by registered customers, the provisions of paragraph 5(10)(iii)(b) and S(lO)(iii)(c) do not apply to measurements related to such customers. An additional individual volume totalizer is considered to provide a primary indication. (e) Micro-processors, which upon disturbance or interference Influence the measurement operation, shall be equipped with means for controlling the continuity of the processor programme and for ensuring the discontinuation of the current delivery when the continuity of the processor program is no longer ensured. The next effective. acceptance of notes, cards or other equivalent mode of payment shall only take place if the continuity of the processor programme is re­ established. (f) When a power supply failure occurs, the delivery data shall be memorized. The requirements of 5(1)(1x) apply. (g) Delayed-payment The printed and/or memorized indications as mentioned in 5.10.3.1 shall contain sufficient information for further checking and at least, the measured quantity, the price to pay and information to identify the particular transaction (e.g. the dispenser number, location, date, time). (h) Pre-payment In unattended service mode. (i) Following the termination of each delivery, the printed and/or memorized indications as intended in paragraph S(lO)(iii)(a) shall be made available, clearly indicating the amount which has been pre-paid and the price corresponding to the liquid obtalned, These printed and/or memorized indications may be divided into two parts as follows:- (a) one part provided prior to the delivery on which the pre-paid amount Is shown and recognizable as such, (b) one part provided following the termination of delivery,provided that it Is clear from the information provided on both parts that they are related to the same delivery. (j) The requirements of 3(6) are applicable. (11) Other self-service arrangements Measuring systems, especially those for loading road or rail tankers, may be designed in such a way that the transaction is not settled when the customer leaves the loading site, in Implicit agreement with the supplier. . In this case, national or international regulations may prescribe .that the self-service arrangement provide additional primary Indications by means of- • a printing device for the issue of a receipt to the customer, and • a device (printing or memory device) on which measurement data 'are registered for the benefit of the supplier. The printed and/or memorized indications shall contain sufficient information for further checking and at least the. measured quantity and information to identify the particular transaction (e.g. the system number, location, date, time). 556 THE GAZETTE OF INDIA: EXTRAORDINARY [PARTll-SEC. 3(i)] Moreover, after a delivery, measuring systems shall not be capable of being reset to zero and authorized until measurement data are memorized or printed out. 6, MetrologlC81 control · When a test is conducted, the expanded uncertainty of the determination of errors on Indications of volume or mass shall be less than one­ fihh of the maximum permissible error applicable for that test on pattern approval and one-third of the maximum permissible error applicable for that test on other verifications. (1) Pattern approval (i) General Measuring systems subject to legal metrology control shall be subject to pattern approval. In addition, the constituent elements of a measuring . system, mainly those listed below, and the sub-systems which include several. of these elements, may be subjectto separate pattern approval: -, • meter, • transducer, • gas separator, • . gas.extractor, f." • specialgas extractor, · J-.'_ • 'electronic calculator (Including the Indicating device), • conversion device, • ancillary devices providing or memorizing measurements results, • pre-setting device, • densitometer, • temperature sensor. The constituent elements of a measuring system shall comply with the relevant requirements even when they have not been subject to separate pattern approval (except, of course, In the case of ancillary devices that are exempted from the controls). Unless otherwise specified in this Recommendation, a measuring system should fulfil the requirements without adjustment of the system or of its devices during the course of the tests. If an adjustment is carried out, this condition shall still be considered as valid. (ii) Documentation (a)The application for pattern approval of a measuring system or of a constituent element of a measuring system shall include the followlngdocuments :- • a description giving the technical characteristics and the principle of operation, • a drawing or photograph, • a list of the components with a description of their constituent materials when this has a metrological influence, • an assembly drawing with identification of different components, • for measuringsystems, the references of the· approval certificate of the constituent elements, If any, • for measuring systems and meters fitted with correction devices, a description of how the correction parametersare · determined, • a drawing showing the location of seals and verification marks, • a drawing of regulatory markings. (b) In addition, the application for pattern approval of an electronic measuring system shall include- • a functional description of the various electronic devices, • a flow diagram of the logic, showing the functions of the electronic devices, • any document or evidence which shows that the design and . construction of the electronic measuring system comply with the requirements of this specification in particular paragraph 4(3). (c) The applicant shall provide the body responsible for the evaluation with an 'instrument representative of the final pattern. [ 'WT 11-1'.'i"s 3 ( i)] 557 Other specimens of the pattern may be considered necessary by the body responsible for the pattern evaluation to . estimate the reproducibilityof the measurements. (iii) Pattern approval certificate · The following Information shall appear on the pattern approval certificate :- name and address of the recipient of the approval certificate, name and address of the manufacturer, if it is not the recipient, type and/or commercial designation, principal metrological and technical characteristics, pattern approval mark, period of validity, environmental classification, if applicable, information on the location of marks for pattern approval, initial verification and sealing (e.g. picture or drawing), list of documents accompanying the pattern approval certificate, specific remarks. When applicable, the version of the metrological part of the evaluated software shall be indicated in the pattern approval certificate or in its annexes. (iv) Modification of an approved pattern (a) The recipient of the pattern approval · shall inform the body responsible for the approval of any modification or addition which concerns an approved pattern. (b) Modifications and additions shall be subject to a supplementary pattern approval when they influence, or are likelyto Influence, the measurement results or the instrument's regulatory conditions of use. The body having approved the Initial pattern shalt decide to which extent the examinations and tests described below shall be carried out on the modified pattern in relation with the nature of the modification. f.i7tr 4()11-tt,o (c) When the body having approved the initial pattern Judges that the modifications or additions are not likely to influence the measurement results, this body allows the modified instruments to be presented for initial verification without granting a supplementary pattern approval. A new or supplementary pattern approval must be Issued whenever the modified pattern no longer fulfils the provisions of the initial pattern approval. (v) Pattern approval or a meter or of a measurement transducer (a) A pattern approval may be given for a complete meter; It may also be given for the measurement transducer only when this is intended to be connected to different types of calculators. The followingexaminations and tests shall be carried out on the meter alone or on the measurement· transducer when It is the subject of a separate application for pattern approval.They may also be carried out on the whole measuring system. Tests are·normally carried out on the complete meter, fitted with an indicating device, with all the ancillary devices and with the correction device, if any. However, the meter subject to testing need not be fitted with its ancillary devices when the latter are not likely to influence the accuracy of the meter and when they have been verified separately (for example : electronic printing device). The measurement transducer may also be tested alone provided that the computing and indicating device has been subject to a separate pattern approval. If this measurement transducer is intended to be connected to a calculator fitted with a correction device, the correction algorithm as described by. the manufacturer must be applied to the output signal of the transducer to determine its errors. (b) Accuracy tests (c) The errors of the meter shall be determined at a minimum of six 558 THE GAZETTE OF INDIA: EXTRAORDINARY [PARTII-SEC. 3(i)] . fJowrates which are distributed over . the measuring range at regular intervals. At each flowrate.the errors shall be determined. at .least three .nmes. independently. ,Each error shall -not be •greater than the ·maximum permissible error (in .ebsolute value). 'In addition, for ,quantities equal .to.or greater than . five .tlrnes the :minimum measured :?uantlty, the ,repeatability requirement in.paraqraph .3(1 )(li)(b) applfes. (d) .,Tests should .be carried out at the .limits of the field of operation, t.e, at the limits of pressure, temperature and viscosity. However, pressure tests are not .necessary when the tedmology of the meter Is such that it is possible to calculate the Influence of pressure and to show that it is negl(glble(for example: meter with pressure-balanced measuring chambers). Note : It is orten unnecessary to carryout tests with liquids having a temperature which differs from the ambient temperature when the meter Is Intended to measure liquids having a temperature between - 10°c and +50°C. (e) The following tests shall also be carried out:- accuracy test at minimum measured quantity, determination of the periodic variation, if appropriate, tests with flow disturbances, if appropriate. For tests with flow disturbances, the applicable maximum permissible errors are those fixed In paragraph 2(5) for the measuring system and not those fixed in paragraph 3(1)(ii) for the meter. (f) When preliminary verification of the meter Is planned to be carried out with a liquid which differs from the liquid the meter is Intended to measure, comparative tests with these two liquids shall also be carried out to determine the maximum permissible errors on preliminary ... verification. It may be necessary to have several specimen of the pattern available. Example: It Is necessary to make a distinction between a pattern of a meter intended to measure several products (in the same measuring system) and a pattern of a meter of which different copies may be used for measuring different products (in different measuring systems), each copy being Intended to measure a given product only. For exam pie, meter A may be intended to measure butane and propane alternatively, whereas meter B is intended to measure either butane or propane. Both meters will be subject to accuracy tests with butane and with propane at the time of patternapproval. For meter A, the error curves for propane and for butane shall both be within the maximum permissible errors as specified in paragraph 3(1)(ii). For meter B, the error curves for butane on the one hand, and for propane on the other hand, shall satisfy the maximum permissible errors; unlike meter A, however, these error curves may be determined using different copies of the meter, or alternatively on the same copy whose adjustment (or correction parameters) has been modified between the test with butane and the test with propane. Copies of meter A will bear the mention of butane and propane on their data plate and they may also be used to measure mixtures of butane and · propane in any proportion. Copies of meter B will bear either the mention "butane" or the mention "propane" and shall be used for measuring the corresponding product exclusively. The preliminary verification of pattern A copies may be carried out with either butane or propane, indifferently (with, if appropriate, a reduction of the maximum permissible errors range). ['1T'Tll?= 3(i)] 559 In general, the preliminary verification of pattern B copies will be carried out with the liquid Intended to be measured; however, It may be carried out with the other liquid provided that the maximum permissible errors have been shifted. The value of shifting shall be determined at the time of pattern evaluation by evaluating the deviation between the error curves determined with butane and with propane, on the same meter, without modification of the adjustment. The deviations shall be reproducible from one copy of the meter to another. To check this, it is necessary to carry out accuracy tests on several Instruments. (g) Endurance tests Endurance tests should be carried out at the maximum flowrate of the meter using the liquid the meter is intended to measure or a liquidwith similar characteristics. When the meter Is Intended to measure different liquids, the test should be carried out with the Jiquld that provides the most severe conditions. An accuracy test shall precede the endurance tests. In principle the duration of the endurance test shall be 100 hours in one or several periods. In specific cases (e.g. new technologies, new alloys, new liquids) the duration may be increased up to 200 hours. The test shall be carried out at a flow rate between 0.8 x Q and Q . rrex max As far as possible, the meter is subjected to the endurance test on a test bench. However, It Is accepted that the meter be temporarily mounted in a measuring system in normal operation, in which case it is necessary that the nominal operating flowrate of the measuring system Is more than 0.8 x Q.,,. After the endurance test, the meter Is again subject to a new accuracy test. The deviations between the errors determined before and after the endurance test shall remain within the limits specified in paragraph 3(1)(ii)(c) without any changes of the adjustment or corrections. (vi) Pattern approval of a gas ellmlnatlon device As a rule, tests shall be carried out to prove that the air or gas. eliminating devices satisfy the requirements In paragraph 2 (lO)(viii) or 2(10)(1x). It is however acceptable that tests are not carried out at flowrates greater than 100 m'/h and that the air separating devices are approved by analogy with devices of the same design, having smaller dimensions. Annexure B describes tests which should be carried out on these devices. The tests are given as examples only. (vii) Pattern approval of an electronic calculator When an electronic calculator is submitted to separate pattern approval, pattern approval tests are conducted on the calculator alone, simulating differentinputs with appropriate standards. (a) Accuracy tests include an accuracy test on the indications of measurement results (volume at metering conditions or price to pay). For this purpose, the error obtained on the indication of the result Is calculated considering the true value. is the one calculated taking Into account the value of the simulated quantities applied to inputs of the calculator and· using standard methods for calculation. The maximum permissible errors are those fixed in paragraph 2(8), {b) When the calculator carries out calculations for a conversion device, tests specified in paragraph 6(1)(vii)(a) are performed for the calculation of volume at base conditions or mass. Accuracy tests also include an accuracy test on the measurement of each characteristic quantity of the liquid. For this purpose, the error obtained on the indication of each of these characteristic quantities these indications are mandatory considering paragraph 3(7)(vii) Is calculated by considering the true value as that provided by the standard connected to the inputs of the calculator and which simulates the corresponding associated. measuring instrument. For each of 560 THE. GAZETTE OF INDIA :'EXTRAORDINARY [PARTII-SEC. 3(i)] :' these quantities, the maximum . . ,permissible.errors fixed in paragraph ,,2{7)(111)shall be applied. · · It IS'then·necessary to perform a test ; to check the presence and.operation •.oU:hecki?g .facilltles ,relevant to . ,associated .measunnq : instruments mentloned in, paragri!ph4(3)(vl). · (c),.Examinations and'tests.descrtbed in .?{l)(x,I) for .electronlc 'instruments ,shall·be performed. (viii) Pattern,approvakofa,conversion device (a) 'General·case • It ls,necessary.to verify whether the ,:conversion device connected to all Its-associated measur.lng Instruments .complies with provisions In 2(7)(i). For that purpose, the volume at metering conditions which Is .converted is supposed to be without any?rror. :It ,may also be verified that the ,provisions in paragraph 2(7)(vi) [and paragraph 2(7)(v) if applicable] are futfllled. In the· case of an electronic . conversion device, the tests and examination described In paragraph 6(l)(ix) shall be performed. (b) Electronic conversion device Instead of the procedure in paragraph 6(1)(viii)(a), it is also possible- to verify separately the accuracy of associated measuring instruments [see paragraph 2(7)(ii)], to verify that the provisions in paragraph 6(l)(vil)(b) are fulfilled, and to perform examinations and tests . described in paragraph 6(1)(xi). (ix) Pattern approval of an ancillary device (a) When an ancillary device that provides primary Indications is intended to be approved separately, its Indications shall be compared with those provided by an Indicating device that has already been approved and which has the same scale Interval, or a smaller one. The results shall satisfy the provisions in paragraph 2(9)(v) . As far as possible, the necessary conditions for compatibility with other devices of a measuring system are stated in the pattern approval certificate . (b) Electronic devices may be approval · separately when they are used for the transmission of primary indications or other information necessary for their determination, e.g. a device which concentrates information from two or more calculators and transmits it to a single printing device. When at least one of the signals of this information is analogue, the device shall be tested in association with another device whose maximum permissible errors are provided by this Recommendation. When all the signals of this information are digital, the above provision may be applied;however, when the inputs and outputs of the device are available, the device can be tested separately, in which case it shall introduce no error; only errors due to the testing method may be found out. fn both cases and as far as possible, the necessary conditions for compatibility with other devices of a measuring system are stated in the pattern approval certificate. (x) Pattern approval of a measuring system The pattern approval of a measuring system consists of verifying that the constituent elements of the system, which have not been subject to separate pattern approvals, satisfy the applicable requirements, and that these constituent elements are compatible with one another. Tests for carrying out the pattern approval of a measuring system shall therefore be determined on the basis of the pattern approvals already granted for the constituent elements of the system. When none of the constituent elements has been subject to separate pattern approval, all the tests provided for in paragraph ···"·· .. --?· .·.··-· ··.··'·'"'-· ? ..... ---- ··'-, [ 'lfll 11-'(l!Us 3 ( i)) 561 6(1)(v), 6(1)(vi) and 6(1)(vii) (in particular) shall be performed on the complete measuring system. On the contrary, when the various constituent elements are all approved separately, it is possible to replace pattern approval based on tests by pattern approval of drawings. lt is also appropriate to reduce the pattern evaluation program when the measuring system Includes constituent elements identical to those which equip another measuring system that has already been approved, and when the operating conditions of these elements are identical. For example, It Is not necessary to perform the expansion test of a hose in a fuel dispenser when the hose in this measuring system Is Identical to the hose equipping another measuring system already approved with the same minimum measured quantity. Note : It Is advisable that constituent elements be subject to separate pattern approval when they are intended to equip several patterns of measuring systems. This is particularly advisable when the various measuring systems have different manufacturers and when the bodies in charge of pattern approval are different. (xi) Pattern approval of an electronic device In addition to the examinations or tests described In the preceding paragraphs, an electronic measuring system or an electronic constituent element of this system shall been subject to the following tests and examinations:- (a) Design Inspection This examination of documents aims at verifying that the design of electronic devices and their checking facilities comply with the provisions of this specification, clause 4 in particular. It lncludes- (a) an examination o( the mode of construction and of the electronic sub-systems and components used, to verify their appropriateness for their intended use, (b) consideration of faults likely to occur, to verify that In all considered cases these devices '17i/ (l{J11-/41 comply with the provisions of paragraph 4(3), (c) verification of the presence and effectiveness of the test device(s) for the checking facilities. (b) Performance tests These tests aim at verifyingthat the measuring system complies with the provisions of paragraph 4(1)(i) with regard to Influence quantities. These tests are specified In Annexure A. (a) Performance under the effect of influence factors: When subjected to the effect of influence factors as provided for in Annexure A, the equipment shall continue to operate correctly and the errors shall not exceed the applicable maximum permissible errors. (b) Performance under the effect of disturbances: When subjected to external disturbances as provided for In Annexure A, the equipment shall either· continue to operate correctly or detect and indicate the presence of any significant faults. Significantfaults shall not occur on non-interruptible measuring systems. (c) Equipment under test (EVT) Tests are carried out on the complete measuring system where size and configuration permit, except where otherwise specified in Annexure A. Where tests are not carried out on a complete system, they shall be carried out on a sub-system comprising at least the following · devices:- .·\ measuring transducer, calculator, indicating device, power supply device, correction device, if appropriate. This sub-system shall be included in a simulation set-up 562 THE GAZETTE OF INDIA: EXTRAORDINARY [PARTII SEC. 3(i)] representative of the normal operation of the .measuring system .. For example, the movement ofthe :liquid may be simulated by an appropriate device. 'The calculator shall be sn its final housing. In all cases, peripheral equipment may be.tested separately. (2) Initial verification (i) General Initial ·verification of a measuring system:is carried out in a single stage when the system can be transported without .dismantling and when it is verified under the intended conditions of use; in all other cases, .lt;ls carried out in two stages. The .first stage concerns at least the measurement transducer, alone or fitted with associated ancillary .devices, or possibly included in a sub­ svstem. Tests of the first stage may be carried out on a test bench, possibly In the factory of the manufacturer, or on the installed measuring system. At this stage, the metrological examinations may be carried out with different liquids than those which the system is intended to measure. The first stage also concerns the calculator and the density sensor. If necessary, the measurement transducer and the calculator can be verified separately. The second stage concerns the measuring system in actual working condition. It is carried out at the place of installation under operating conditions and with the Intended· liquid of use. However, the second stage may be carried out in a place chosen by the verification body when the measuring system can be transported without dismantling and when the tests can be performed under the operating conditions intended for the measuring system. Initial verification of electronic systems shall include a procedure for verifying the presence and correct operation or checking facilities by the use of test devices as specified In paragraph 4(3). (ii) Tests (a) When initial verification takes place in two stages, the first stage shall include- an examination for conformityof the meter, including the associated ancillary devices (conformity with the respective patterns), - a metrologlcal examination of the meter, Including the associated ancillary devices. The second stage shall include-­ an examination for conformity of the measuring system, including the meter and the ancillary and additional devices, a metrological examination of the measuring system; if possible, this examination is carried out within the limits of operating conditions for the system, an operational test of the gas elimination device, where appropriate, with no need to verify that the maximum errors applicable to this device and specified in 2.10 are met, an inspection of the adjustment of the prescribed pressure maintaining devices where appropriate, when necessary, a test of the variations of the internal volume of the hoses in full hose measuring systems, e.g. in the case of a hose reel, an operational test of the control valve preventing the emptying of the hose during non· operating periods, for full hose measuring systems, a determination of the residual quantities In empty hose measuring systems. (b) When initial verification takes place in one stage, all tests In paragraph 6(2)(ii)(a} shall be performed. ['ll'l 11-= 3(i)] 563 - --- ---- ---?- ??--- =-=-----=-----=---..:..=::::=-====== Test Nature of the influence quantity Severity level for the class --··-- 8 C I L Dry heat ln,fluencefactor 2 3 3 2. Cold Influence factor 2 3 3 3, Damp heat, cyclic Influence factor l 2 2 4. Vibration (sinusoidal) Influence factor l 5. Power voltage vartation Influence factor l I 6. Short time power reductions Disturbance la & lb la & lb la & lb 7. Bursts Disturbance 2 2 i 8. Electrostatic discharge Disturbance l l I 9. Electromagnetic susceptibility Disturbance 2, 5, 7 2, 5, 7 2, 5, 7 10. Disturbances on d.c. voltage powered equipment Ambient temperature Relative humidity Atmospheric pressure Power voltage Power frequency : 20°c ± s0c : 60% ± 15% : 86 kPa to 106 kPa : Nominal voltage (Vnom) : Nominal frequency (Fnoml During each test, the temperature and relative humidity shall not vary by more than 5°C or 10% respectively within the reference range. 4. Performance tests The following tests can be carried out in any order:- 2. Severity levels For each performance test, typical test conditions are indicated: they correspond to the climatic and mechanical environment conditions to which measuring systems are usually exposed. Measuring systems are divided into three classes according to climatic and mechanical environmental conditions: Class B for fixed Instruments installed in a building, Class C for fixed Instruments installed outdoors, Class I for mobile Instruments, in particular measuring systems on trucks. However, the applicant for pattern approvalmay indicate specific environmental conditions in the documentation supplied to the metrology service, based on the intended use of the Instrument. In this case, the metrology service carries out performance tests at severity levels corresponding to these environmental conditions. If pattern approval Is granted, the data plate shall indicate the corresponding limits of use. Manufacturers shall inform potential users of the conditions of use for which the instrument is approved. The metrology service shall verify-that the conditions of use are met. 3. Reference conditions (3) Subsequent verification (i) Subsequent verification of a measuring system may be identical to initial verification. (ii) The preliminary examination of the meter should only be repeated if the protective marks on the measuring element of the meter have been damaged. This examination may be replaced by a test of the measuring system if the conditions for the preliminary examination are met and if the measuring system can undergo testing with a volume of liquid corresponding to the minimum measured quantity. For the detennination of the error curve, at least 60% of the maximum flowrate should be reached. (iii) The ancillary devices shall be considered as having been subjected to the preliminary examination if the protective marks are not damaged. It is sufficient to carry out a reduced number of measurements during the simplified examination of the ancillary devices.

Previous and next

All provisions of Legal Metrology (General) Rule, 2011

Questions people ask

Is annexure A of Legal Metrology (General) Rule, 2011 still in force?

No repeal of Legal Metrology (General) Rule, 2011 is recorded.