Annexure A, Legal Metrology (General) Rule, 2011: ANNEXURE A

Legal Metrology (General) Rule, 2011 - Annexure A

Text of annexure A

ANNEXURE A

ANNEXURE A TESTING PROCEDURES FOR AUTOMATIC GRAVIMETRIC FILLING (Mandatory) [See paragraph 2(5)) Meaning of symbols I = Indication In = nth Indication L = Load AL = Additional load to next changeover point P = I+ 1/2 d • 6 L + Indication prior to rounding (digital indication) E = P • L = Error mpd = Maximum permissible deviation of each fill from the average EUT = Equipment under test se = Setting error mpse = Maximum permissible setting error md = Maximum deviation of each fill from the average 1.. Examination for pattem approval (1) Administrative examination [paragraph 5(2)] Review the documentation that is submitted to determine if it Is adequate and correct. For pattern approval the documentation shall include:- 1(l){a) metrologlcal characteristics of the instrument, l(l)(b) a set of specifications for the instrument, l{l)(c) a functional description of the components and devices, and l(l)(d) drawings, diagrams and general software Information (If applicable), explaining the construction and operation, Including interlocks. Consider any document or other evidence that , the design and construction of the instrument complies with the requirementsof this specification. (2) Compare construction with documentation [paragraphs 4(3) and 5(2)] Examine the various devices of the instrument to ensure conformity with the documentation. (3) Technical requirements (Paragraph 3) Examine the instrument for conformity with technical requirements according to the checklist given In the test report format. · (4) Functional requirements [Paragraphs 4(2} and 4(3)) Examine the instrument for conformity with functional requirements according to the checklist given in the test report format. 2. Examination for initial verlncation (1) Compare construction with documentation [paragraph S(3}(i}} Examine the instrument for conformity with the approved pattern. (2) Descriptive markings [paragraph 3(10}]: Check the descriptive markings according to the checklist given in the test report format. 3. General test requirements (1) Power supply Power up the equipment under test (EUT) for a time period equal to or greater than the warm-up time specified by the manufacturer and maintain the EUT energized for the duration of each test. (2) Zero-setting Using the manual or semi-automatic zero· setting facility,adjust the EUT as closely as practicable to zero prior to each test, and do not readjust it at any time during the test, except to reset if a significant fault has been indicated. Status of automatic zero facilities shall be as specified for each test. (3) Temperature The tests shall be performed at a steady ambient temperature, usually normal ambient temperature unless otherwise specified. The temperature is deemed to be steady when the difference between the extreme temperatures noted during the test does not exceed one-fifth of the temperature range of the instrument without being greater than S°C, and the rate of change does not exceed S°C per hour. __J. - 466 .THE .GAZETTE <OF :JNDIA: EXTRAORDINARY [PARTIl=-Ssc. 3(i)] The handllng:of the instrument shall .be such that no condensation .of -water .occurs on the instrument. (4) Control instruments (l)Accuracrof tesf.system[paragraph 6(4)} The control Instrument and standard weights· used in testing shail.ensuretne-determmation of the weight of test loads,andJills toan error not greater than either: (a) one-third ,of :the .maximum permissible error of:theJnstrument t.a, In the case of matertaltests, one-third of the maximum permissible deviation and maximum permissible preset value error (as appropriate) for automatic weighing, if the control Instrument or the device used for control purposes is verified immediately prior to the material test; or (b) one-fifth of the maximum permissible error of the Instrument i.e., In the case of . material tests, one-fifth of the maximum permissible deviation. and maximum permlsslble preset value error (as appropriate) for automatic weighing, in all other cases. Note: Accuracy requirements for the test system depend on the limits of error which depend on the accuracy class. However, the class is determined from the results of the tests. It is, therefore, necessary that the metrological authority responsible for testing should be informed of the best accuracy class that may be achieved, prior to commencement of testing. (ii)Use of standard weights to assess rounding error (a) General method to assess error prior to rounding; For Instruments with digital indication having a scale interval d, changeover points may be used to interpolate between scale Intervals, i.e. to determine the indication of the instrument, prior to rounding, as follows:- · At a certain load, L, the Indicated value, I, is noted. Additional weights of say 0.1 d are successively added until the indication of the instrument is Increased unambiguously by one scale interval (I +d). The additional load el, added to the load receptor gives the indication, P, prior to rounding by using the following formula:- P = I + 0.5 d - t. L The error prior to rounding is: E = P • L = I + 0.5 d - t. L - L Example. An instrument with a scale interval, d, of 5g Is loaded 1kg and thereby Indicates 1000g. After adding successive weights of O.Sg, the indication changes from 1000g to 1005g at an additional load of 1.Sg. Inserted in the above formula these observations give: P = (1000 + 2.5 • 1.5) g = 10019 Thus the true indication prior to rounding is 1001 g, and the error prior to rounding is: . E = (1001 • 1000) g : + 1 g (b) Correction for error at zero Evaluate the error at zero load, (E 0) by the method specified in paragraph 3(4)(ii)(a) of this Annex. Evaluate the error at load L, (E) by the method specified in paragraph 3(4)(1i)(a) of this Annex . The corrected error prior to rounding, (Ee) Is: Ec:E-Eo Example: if, for the example in paragraph 3(4)(ii)(a), the error calculated at zero load was: · Eo = + 0.5 g The corrected error is: Ee = + 1 - ( + o.5) = + o.sg 4. Test program (1) Patte,n evaluation [paragraph 5(2}(iil)} (I) Paragraphs 1, S, 6, 7 and 8(1) of this Annex shall normally be applied for pattern evaluation. (Ii) For instruments In which the weighing function is provided by a non-automatic weighing instrument that has been approved of its model, the tests specified In paragraph 4(l)(i) may be omitted. (2) !nit/al verification [Paragraph 5(3)} Paragraph 2 and paragraph 8(2) of this Annex shall be applied for initial verification tests. Static weighing test method (paragraph 5(4) of this Annex) may also be used if necessary to verify the indicator for the integral verification method of material tests. 5. Static tests (pattern approval stage) (1) General Paragraph 5{2}(il) Electronic instruments or Instrument simulators are required to have a load indicator, or an interface ['Wf Jl-- J(i)] 467 allowing access to quantity that can be calibrated to provide an indication of load so that the effect of influence quantities may be tested and the reference accuracy class determined. This facility also enables testing of warm-up time and zero-and tare-setting where applicable. This static weighing tests are normally done as part of influence quantity testing. Limits for warm-up time tests and for accuracy of zero-and tare-setting are derived from Paragraph 2(2), and are therefore dependent on the reference accuracy class. Therefore the results of these tests must be evaluated after the reference accuracy class has been determined. (2) Warm-up time [Paragraph 4(2)(iii)J This rest Is to verify that in the period immediately after switch-on, operation is inhibited until the warm-up time is finished, I.e. until the metrological performance can be maintained. The method is to check that automatic operation is inhibited until a stable Indication is obtained and to verify that zero and span errors comply with the specified requirements during the first 30 minutes of operation. If the zero Is set as part of the normal automatic weighing cycle then this function shall be enabled or simulated as part of the test. Other test methods which verify that metrological performance is maintained during the first 30 minutes of operation may be used: (i) Disconnect the instrument from the power supply for a period of at least 8 hours prior to the test. (ii) Reconnect the instrument and switch on while observing the load indicator. (iii) Check that It is not possible to initiate automatic weighing until the Indicator has stabilized. (iv) As soon as the indication has stabilized, set the Instrument to zero if this is not done automatically. (v) Determine the error at zero by the method of para 3(4)(ii)(a) of Annexure A. (vi) Apply a static load close to Max. Determine the error by the method of paragraphs 3(4)(ii)(a) and 3(4}(11)(b)of this Annex. · (vii) Repeat steps (v) and (vi) after 5, 15 and 30 minutes. (viii) From (v) verify that the zero-setting error is not greater than the limit specified in paragraph 3(7); (ix) From steps (vi) and (vii) verify that: (a) the error (corrected for zero error) for a static load close to Max is not greater than the limit specified In · paragraph 2( 4). (b) after each tlme Interval the error at zero is not greater than twice the . limit specified In paragraph 3(7). Note. Zero-setting accuracy Is specified as 0.25 mpd so the additional allowance of 0.25 mpd is added for variation of zero after the initial zero-setting. This is consistent with paragraph 2(4) (rnpe for a static test load) and paragraph 6(2)(11) of this Annex (temperature effect on no load indication). (3) Zero- and tare-setting paragraph 3(7) (l)Generaf. Unless It is clear that zero and tare functions are performed by the same process then both function shall be tested separately. Zero-and tare-setting maybe by more than one mode, for example: (a) non-automatic or semi-automatic, (bl automatic at switch-on, (c) automatic at start of automatic operation, (d) automatic as part of weighing cycle. It is normally only necessary to test the accuracy. ofzero-and tare-setting in one mode if it is clear that the same process is used for each mode. If zero or tare is set as part of the automatic weighing cycle then this mode shall be tested. To test automatic zero-or tare-setting it is necessary to allow the instrument to operate through the appropriate part of the automatic cycle and then to halt the instrument before testing. (ii) Accuracy of zero-settrng [paragraph 3(7)]: ( 1) Set the instrument to zero in a mode as determined by paragraph 5(3)(i) of this Annex. (2) Add weights to the load receptor to determine the additional load at which the Indication changes from zero to one scale interval above zero. (3) Calculate the error at zero according to the description in paragraph 3(4)(ii)(a) of this Annex. (iii) Accuracyoftare-settfng {paragraph 3(7)}: Accuracy of tare shall be tested at the maximum tare as specified by the manufacturer. (1) Place the tare load on the load receptor and allow the tare function to operate In a mode as determined by paragraph ----?----------------? --- 468 THE ',GAZETTE OF INDIA: EXTRAORDINARY (PART!I-SEC 3(i)] 5(3)(1) of this Annex and In accordance with the manufacturer's instructions. (2) Add weights .to ·the load receptor to determine the additional'load at which the indication chanqes.frorn zero to one scale interval .above zero. (3) Calculate the error according to the description In paragraph 3(4)(il)(a)of this Annex. (4) Static weighmg'test,method[paragraph S(2)(iii)} Apply test.leadsfrom zero up to and including Max, and simila?yremove the test loads back to zero. The test loads selected shall include values close to Max and Min and other critical loads as specified in paragraph 6(2)(a), subject to requirements of this Annex. Determine :tbe error at each test load, using the procedure of paragraph 3(4)(ii) of this Annex, if necessary, to obtain the accuracy requirements of paragraph 3(4)61)of this Annex. It should be noted that when loading or unloading weights, the load shall be progressively Increased or progressively decreased. (S) Determination of reference accuracy class [paragraph S(2)(v)J The static weighing tests during application of Influence factors (as appropriate) shall be used at pattern approval stage to establish the reference value for accuracy class, l.e. Ref(x), as follows :- (i) Perform static weighing tests for Influence factors and loads as specified in this Annex. (ii) For each load determine the maximum permissible error for influence factor tests for class X(l), mpe(l) (Refer to para 2(4) and to this Annex where appropriate). (iii) Calculate [Error/mpe(l)lfor each load. (iv) From (Ill)determine the maximum value of [Error/mpe(t)lfor all the Influence factor tests, [Error/mpe(l)m"] (v) Determine Ref (x) from [Error/mpe(l)m,,l such that : Ref (x)> [Error/mpe(lJl max and Ref (x) = 1 x 10k , 2 x 10k , or 5 x 10k, the Index k being a positive or negative whole number or zero. Values for significant fault shall then be calculated from the mpd for the reference class. 6. Influence factor and disturbance tests (1) Test conditions (!)General requirements: Influence factor and disturbance tests are Intended to verify that electronic Instruments can perform and function as Intended in the environment and under the conditions specified. Each test Indicates, where appropriate, the reference condition under which the Intrinsic error Is determined. It Is generally not possible to apply the influence factors or disturbances to an instrument which Is processing material automatically. The Instrument shall therefore be subjected to the influence factors or disturbances under static conditions or simulated operation as defined herein. The permissible effects of the influence factors or disturbances, under these conditions, are specified for each case. When the effect of one influence factor Is being evaluated, all other factors are to be held relatively constant, at a value close to normal. After each test the instrument shall be allowed to recover sufficiently before the following test- Where parts of the instrument are examined separately, errors shall be apportioned in accordance with paragraph 5(2)(iii)(c). The operational status of the instrument or simulator shall be recorded for each test. When the instrument is connected in other than a normal configuration, the procedure shall be mutually agreed on by the approving authority and the applicant. (ii) Simulator requirements (a) General The simulator for influence factor and disturbance tests should include all electronic elements of the weighing system. (b) Load cell The simulator should also include the load cell and a means to apply standard test loads. Where this Is not possible, e.g. for high capacity instruments, then a load cell simulator may be used or alternatively the load cell interface -=,----,--,--',,--cc,-----,=cc-cc=====r-= •. :::.,.=--= ... =-- .. t??c-. - ... -?--? ... ?.,.r.1 .. ===CCTc.r,1._cr.,,,::_:::-,rc.??-•=·•cc,c: •• r,cc= .. _,cccc,.r==::::.,.= .. tcc .... -====?=-- ['WT!!-- 3(i)] 469 may be modified to incorporate a . scaling factor to give the design output for a small test load. Repeatability and stability of a load cell simulator should make It possible to determine the performance of the instrument with at least the same accuracy as when the instrument Is tested with weights. (c) Interfaces Susceptibility that would result from the use of electronic interfaces to other equipment shall be simulated In the tests. For this purpose it is sufficient to connect 3 m of interface cable terminated to simulate the interface impedance of the other equipment. (d) Documentation Simulators shall be defined in terms of hardware and functionality by reference to the instrument under test, and by any other docu­ mentation necessary to ensure reproducible test conditions. This Information shall be attached to, or be traceable from the test report. (iii) Test limits for multi-load instruments : For instruments where the fill may consist of more than one load, the value of a significant fault and the limit of error for influence factor tests must be determined by the metrological authority after considering the design of the Instrument and the method of test, such that the effect on the fill is equivalent to the values specified In paragraph 4(2)(v) specified in Part I and paragraph 2(4) of Part II. (a) Significant fault for multi-load Instruments The following examples show how to determine the value of a significant fault on selective combination weighers and cumulative weighers when testing. (a-1) Significant fault for selective combination weighers A fault greater than 0.25 of the maximum permissible deviation of each fill (as specified in Table 1) for in-service verification divided by the square root of the average ( or optimum) number of loads in a fill, for a fill equal to the minimum capacity multiplied by the average (or optimum) number of loads In a fill. Example : For .a class X(l) instrument with Min = 200g designed for an average of 8 loads per fill, fill = 1600g, the maximum permissible deviation of each fill from the average fill (as specified In Table 1) for in-service verification is 1.5% = 24g. Hence the value of significant fault Is : 0.25 X (24/ \ 8) = 2.12g (a·ii) Significant fault for cumulative weighers: A fault greater than 0.25 of the maximum permissible deviation of each fill (as specified in Table 1) for in-service verification, for a fill equal to the rated minimum fill,divided by the square root of the minimum number of loads per fill. Example : For a class X ( 1) instrument with Max = 1200g and rated minimum fill of 8 kg: 8 kg/1.2 kg = 6.67; therefore the minimum number of loads per fill is 7. The maximum permissible deviation (as specified in Table 1) for the minimum fill of 8 kg is 1.5% or 120g. Hence the value of significant fault Is : 0.25 X ( 120/ Y7) = 11.34g Note : This definition of significant fault for cumulative weighers does not include Min. A cumulative weigher would normally be used at or near to Max. (b) Limits of error for influence factor tests The following examples show how to determine the limit of error for influence factor testing for selective combination weighers and cumulative weighers when testing. (b-i) For selective combination weighers the maximum permissible error for 470 THE GAZETTE OF INDIA: EXTRAORDINARY [PARTII-SEC. 3(i)] Environmental Phenomena Test specification Reference of 200c Temperature Specified high for 2 hours Specified low for 2 hours s0c Reference of 200c (*) mpe : maximum permissible error (!)Static temperatures (paragraph 2(5){i) Static temperature tests are carried out according to Table 3 given below : TABLE 3 Object of the test: to verify complaince with the provisions in paragraph 2(5)(1) under conditions of dry heat (non condensing) and cold. The test specified in 6(2)(ii) of this Annex may be conducted during this test. Test procedures in brief Precondition : 16 hours Mpe(*) Mpe(*) Mpe(*) · Mpe(*) Mpe(*) Conditions applied Normal power supplied and "on" for a time period equal to or greater than the warm-up time specified by the manufacturer. Power Is to be "on" for the duration of the test. The automatic zero-setting should be disabled. 2 hours at each temperature under "free air" conditions. As specified in paragraph 2(5)(1) Characteristic under test (2) Influence factor tests SUMMARY OF TESTS Test Stabilization : Temperature sequence : Reference temperature of 20°C Specified high tem­ perature Specified low temperature Temperature of soc Reference temperature of 20°c Temperature : Condition of the EUT : Static temperatures Influence factor Temperature effect on Influence ractor no-load indication Damp heat, steady state Influence factor Power voltage variation Influence factor Tilting In"uence factor any:statlctest load during influence factor Jests shall be 0.25 of the maximum permissible deviation for ln-.service verification for the appropriate rnass of the fill divided by the square mot of the average (or optimum) number of loads per fill. Example : Class X(1) selective combination weigher, where the average number of loads per fill = 4. For a .static test load = 100g the appropriate mass of the fill will be 400g for which the maximum permissible deviation for in-service verification is 3% i.e. 12g. Hence the maximum permissible error for Influence factor tests Is : 0.25' (12g/4) = 1.Sg (b-il) For cumulative weighers the maximum permissible error for any static test load during influence factor tests shall be 0.25 of the maximum permissible deviation for In-service verification for the rated minimum fill divided by the square root of the minimum number of loads per fil I. Example : For a class X(1) Instrument with Max = 1200g and rated minimum fill of s·kg : 8 kg/1.2 kg = 6.67; therefore the minimum number of loads per fill = 7. The maximum permissible deviation (as specified in Table 1) for the minimum fill of 8 kg is 1.5%, i.e. 120g. Hence the maximum permissible error for influence factor tests Is : 0.25' (120/ ,J 7) = 11.35g Note: For cumulative welghers the average number of loads per fill is not known. Therefore It is not possible to define the limit of error for Influence factors in terms of average loads per fill and appropriate mass of the fill. The above definition is based on maximum load and rated minimum fill. ["!T'Tn-= 3(i)J 471 Maximum allowable variations : (iii) Damp heat, steady state [paragraph 4(J)(ii)j Damp heat, steady state test are carried out according to Table 4. The zero-setting and zero- tracking facilities shall be enabled as for normal operation. Adjust the EUT as i close to zero Indication as is practicable, prior to the test. The handling of the EUT shall be such that no condensation of water occurs on the EUT. · Maximum permissible variations : The change in zero Indication shall not yary by more than the maximum permissible error for Infiuence factor tests tor· a load equal to the rated minimum fill, for a temperature difference of soc. Condition of EUT : Normal power supplied and "on" for a time period equal to or greater than the warm-up time specified by the manufacturer. Power is to be "on" for the duration of the test. Test specification Upper limit tem­ perature and relative humidityof 85% for 2 days To verify compliance with the provrsrons of paragraph 4(3)(i) under conditions of high humidity and constant temperature. None required. One static test load close to minimum capacity. Normal power supplied and "on" for a time period equal to or greater than the warm· up time specified by the manufacturer. Power Is to be "on" for the duration of the test. TABLE 4 Environmental phenomena Damp heat, steady state Supplementary information : Object of the test : Condition of the EUT : Precondition : Test load: Number of test cycles : At least one cycle. Weighing test : After stabilization at the reference· temperature and again at each specified temperature conduct the following : Adjust the EUT as close to zero indication as practicable. It is important to ensure that the test result is unaffected by the automatic zero-setting function which should therefore be disabled. The EUT shall be tested with at least five different static test loads (or simulated loads) including Maximum and Minimum capacities. When loading or unloading weights the load must be respectively increased or decreased monotonically. Record : (a) date and time (b) temperature (c) relative humidity (d) test load (e) indications (f) errors (g) functional perform- ance All functions shall operate as designed. All errors shall be within the maximum permissible errors specified in paragraph 2(4 ). (II) Temperature effect on no-load indication Note : This test should not be performed for instruments that have automatic zero-setting as part of the automatic weighing process. The instrument Is set to zero, the temperature is then changed to the prescribed highest and lowest temperatures as well as at S°C. After stablllzatiori, the error of the zero Indication is determined. The change in zero Indication per S°C is calculated. The · changes of these errors per S°C are calculated for any two consecutive temperatures of this test. This test may be performed during the temperature test [paragraph 6(2)(i) of this Annex]. ___ _j _ 472 ;THE :G:A:ZETTE :of INDIA: EXTRAORDINARY · [PART!I-SEC. 3(i)] Maximum allowable variations : All errors shall be within the maximum permissible errors specified In paragraph 2(4). (Iv) Power voltage variation [paragraph 2(5)(iiJJ Power voltage variation tests are carried out • according to Table 5. Test specification To verify compliance with the provisions of paragraph 2(5)(11) under conditions of voltage variations. TABLE 5 None required. Normal power supplied and "on" for a time period equal to or greater than the warm­ up time specified by the manufacturer. Adjust the EUT as close to zero indication as practicable, prior to the test. If it has an automatic zero-setting function then the Instrument should be set to zero after applying each level of voltage. At least one cycle. The EUT shall be tested with a test load approximately equal to the minimum capacity. Zero-setting function shall be in operation. Stabilize the power supply at the reference voltage within the defined limits and apply the test load. Record the followingdata :(a) date and time (b) temperature (c) power supply voltage (d) test load (e) indications (as applicable) (f) errors (g) functional performance Environmental phenomena Reference voltage Voltage variation Reference voltage + 10% Reference voltage - 15% Reference voltage SUPPLEMENTARY INFORMATION : Test sequence : Test procedures in brief Precondition : Condition of the EUT : Number of test.cycles : Weighing test : Object of the test : -50% at reference temperature. 85% at upper limit temperature. The reference tem­ perature of 20°C at 50% humidity. The upper limit temperature at 85% humidity. The reference temperature of 20°c at 50% humidity. 'Reference temperature 0 -of.20 C and atthe upper limit as specified In :paragraph 2(S)(i). Three hours.at reference -temperature and '50% humidity:n:wodays atthe , upper .lirnlt temperature -as specitledin ,paragraph 2{5){i). Stabilization : Relative humidity:: Temperature : Record: Temperature humidity sequence : Number of test cvdes : Weighing-test and test sequence: At least one cycle. Alter stabilization of the EUT at reference temperature and 50 % humidity apply the test load. (a) date and time (b) temperature (c) relative humidity (d) test load (e) indications (f) errors Increase the temperature in. the chamber to the upper limit and increase the relative humidity to 85%. Maintain the EUT at no load for a period of 2 days. Following the 2 days, apply the static test load and record the data as indicated above. Allow full recover of the EUT before any other tests are performed. / ['WT u-= J(i)J 473 (v) Tilting [paragraph 2(5}(iii)] Note: This test only applies to instruments that will not be penmanently Installed. This test fs not required for mobile instruments with a level indicator If It can be established that the tilt can be adjusted to 1% or less. Test method : Static tests whilst the EUT is tilted. Test sequence : Maximum allowable variations : Object of the test : Test procedure In brief : Test severities : Maximum allowable variations : Condition of EUT : All functions shall operate as designed. All errors shall be within the. maximum permissible errors specified in paragraph 2(4). To verify compliance with the provisions in paragraph 2(5)(iii) under conditions of tilt. The test consists of tilting the EUT both forwards and back­ wards, longitudinally and from side to side (transversely), while observing the weight indications for a static test load. Instruments without level indicatorsshall be tested at a tilt of 5%. All indications shall be within maximum permissible errors specified In paragraph 2(4). Normal power supplied and "on" for a time period equal to or greater than the warm­ up time specified by the manufacturer. Power Is to be "on" for the duration of the test. Adjust the EUT In its reference position (not tilted) as close to zero indication as practi­ cable. If the instrument is provided with automatic zero-setting it shall not be in . operation. The test sha 11 be performed with a test load approximately equal to the maximum capacity. Record the zero Indication. Apply the . test load and record the Indication. Remove the test load. TIit the EUT longitu­ dinallyto the appropriate extent and record the zero Indication. Apply the test load and record the indication. · Remove the test load. Without further adjust· ment to any control affecting metrologlcal performs nee tilt the EUT to the appropriate extent in the opposite direction and repeat the static weighing tests as above. TIit the EUT in the transverse direction to the appropriate extent and repeat the tests. TIit the EUT in the opposite direction and repeat the tests. In order to determine the infiuence of tilting on the loaded instru­ ment, the indication obtained at each tilt shall be corrected for the deviation from zero which the instrument had prior to loading. (3) Disturbance tests [paragraph 4(1){iii)J ·(f)Short time power reduction Short time power reduction (voltage dips and 474 THE:GAZETTE :Of 'INDIA: EXTRAORDINARY IPART II-SEC 3(i)] short lnterruptionsj.tests are.carrled out.accordlnq to Table 6. Object of the test : To verifycompliance with the provisions in paragraph 4(1) (iii)under conditions of short mains voltage Interrup­ tions and reductions while observing the weight Indication for a static load approximately equal to the minimum capacity. - Test procedures In brief: Precondition : None required. Condition of the EUT: Normal power supplied and "on" for a time period equal to or greater than the warm-up time specified by the manufacturer. Adjust the EUT as close to zero indication as practi­ cable, prior to the test. Zero-setting functions shall not be in operation. Not to be adjusted or readjusted at any time during the test except the reset if a significant fault has been indicated. At least one cycle. The EUT shall be tested with a test load approximately equal to the mini· mum capacity. Stabilize all factors at nominal reference con-ditions. Apply the test load and record the following data: • (a) date and time (b) temperature (c) power supplyvoltage (d) test load (e) indications (f) errors (h) functional perfor­ mance Interrupt the power supply to zero voltage for a period equal to one half cycle and conduct the test. During interruption observe the effect on the EUT and re­ cord, as appropriate. Reduce the power supply to 50% of nominal voltage far a period equal to two half cycles and conduct the test. During reductions observe the effect · on the EUT and re· cord, as appropriate. Number of test cycles : Weighing test and test variations : ,, Testspeciflcation TAB1:E6 -Interruptlcn from .reference -voltage .to. zero voltage ,for .one-half.cycle. Interruption from -reference voltage to 500/oofreference vciltagefortwo half .cvcles. These mains vcltage interruptions shall be repeated ten times with a time interval of at least 10 seconds Supplementary information to the test procedures : Environmental phenomena Voltage dips and short interruptions. [ ,wr II -19'16 3 (i ) ] 475 Maximum allowable variations: The difference between the weight indication due to the disturbance and the indication without the disturbance either shall not exceed the values given in paragraph 4(2)(v), or the EUT shall detect and act upon a significant fault. Supplementary information to the test procedures : Object of the test : To verify compliance with the provisions in paragraph 4( 1)(111)under conditions where electrical bursts (fast transients) are super· imposed on the mains voltage while observing the weight Indication for a static test load approximately equal to the minimum capacity. Test procedures in brief: Test specification 8 kV air discharge 6 kV contact discharge Precondition : Condition of the EUT : Weighing test : Stabilization : Environmental phenomena None required. Normal power supplied and "on" for a time period equal to or greater than the warm· up time specified by the manufacturer. Reset the EUT if a significant fault has been indicated. Before any test stabilize the EUT under constant environmental conditions. With the single static load In place record the following with and without the transients :- (a) date and time (b) temperature (c) test load (d) indications (as applicable). Maximum allowable The difference between the variations : weight Indication due to the disturbance and the indication without the disturbance either shall not exceed the value given In paragraph 4{2)(v) of Part !, or the Instrument shall detect and act upon a significant fault. (iii) Electrostatic discharge Electrostatic discharge tests are carried out with test signals and conditions as given in Table 8 below: TABLE 8 Electrostatic discharge A coupling/decoupling network shall be applied for testing AC power ports. TABLE 7.2 Input and Output DC Power Ports Environmental phenomena Test specification Fast transient common mode 0.5 kV (peak) 5/50 ns T 1/Th 5 kHz rep. frequency Environmental phenomena Test specification Fast transient common mode 0.5 kV (peak) 5/50 ns T 1/Th 5 kHz rep. Frequency (ii) Eledrica/ btJrsts{fast transient tests) Electrical bursts tests (fast transient tests) are carried out for two minutes with a positive polarity and for 2 minutes with a negative polarity according to Tables 7.1, 7.2 and 7.3 given below : TABLE 7.1 Ports for signal lines and control lines Environmental phenomena Test specification Fast transient common mode 0.5 kV (peak) 5/50 ns T 11'Th 5 kHz rep. Frequency TABLE 7.3 Input and Output DC Power Ports Note : Not applicable to battery operated appliances that cannot be connected to the mains while in use. Note : Applicable only to ports or interfacing with cables whose total length may exceed 3m according to the manufactures functional specification. 476 THE GAZETTE OF INDIA: EXTRAORDINARY [PARTII-SEC. 3(i)] Stabilization : Weighing test : Maximum allowable : The difference between the variations : weight indication due to the disturbance and the indication without the disturbance either shall not exceed the value given in paragraph 4(2)(v) of Part I or the instrument shall Test method : Object of the test : Span stability. To verifycompliance with the provisions of paragraph 4(3)(111)after the EUT has been subjected to the performance tests. Reference to standard : No reference to international standards can be given. The EUT shall be stabilized at sufficiently constant ambient conditions after detect and act upon a significant fault. 7. Span stability test [paragraph 4(3)(iii)] Test procedure in brief :Thetestconslstsofobserving the variations of error of the EUT under sufficiently constant ambient conditions (reasonably constant conditions in a normal laboratory environment) at various intervals, before, during and after the EUT has been subjected to performa nee tests. The performance tests shall include the temperature test and, if applicable, the damp heat test. Other performance tests listed in this Annex may be performed. The EUT shall be disconnected from the mains power supply, or battery supply where fitted, two times for at least eight hours during the period of the test. The number of disconnections may be increased if the manu­ facturer specifies so or at the discretion of the approval authority in the absence of any such specification. In the conduct of this test, the operating instructions for the Instrument as supplied by the manu-facturer shall be considered. Note : The 6 kV contact discharge shall be applied to conductive accessible perts. Metallic contacts e.g. In battery compartments or In socket outlets are excluded from this requirement. Contact discharge is the preferred.test method. 20 discharges (10 with positive and 10 with negative polarity) shall be applied on each accessible metal part of the enclosure. The time :Interval between successive discharges shall be at •feast 10 s. In the case of a non conductive encosure, discharges shall be applied on the horizontal .or vertical coupling planes. Air discharges shall be used where contact discharges cannot be applied. Tests with other (lower) voltages than those given In :fable 8 are not required. Supplementary Information to the test procedures : Object of the test : To verify compliance with the provisions of paragraph 4(1)(iii) under conditions where electrostatic discharges are applied while observing the weight Indication for a static test load approximately equal to the minimum capacity. Test procedures In brief: Precondition : None required. Condition of the EUT : Normal power supplied and "on" for a time period equal to or greater than the warm-up time specified by the manufacturer. Reset the EUT if a significant fault has been indicated. Before any test stabilize the EUT under constant environmental conditions. With the single static load in place, record the following with and without electrostatic discharge :­ (a) date and time (b) temperature (c) testload (d) indications (as appli­ cable). ['1T'TII-@="s==3(=i)?J================="lml===<!>T==(l=?q="='=mn==m(Ul=========================4==77 variations : Test severities : Test sequence : Maximum allowable (e) test load (f} Indication (g) errors (h) changes in test location and apply all necessary corrections resulting from verlatlcnsof temperature, pressure, etc. between the various measurements. At the first measurement immediately repeat zeroing and loading four times to determine the average value of error. For the next measurements perform only one, unless either the result is outside the specified tolerance or the range of the five readings of the initial measurement was more than 1/10 of the maximum permissible variation. Repeat this test at periodic intervals during and after the conduct of the various performance tests. Allow full recovery of the EUT before any other tests are performed. 8. Procedure for material tests (1) Material tests at pattern evaluation [paragraph 5(1}{/i)(a) and paragraph 5(2)] · Operational tests with material shall be done on a complete instrument to assess compliance with the technical requirements of sub-paragraph (3) with material for the test load as specified in paragraph S(l)(il)(a). (i) Feeding device [paragraph 3(5)} Check that the feeding device provides sufficient and regular flow rate. Check that any adjustable feed device has an Indication of the direction of movement corresponding to the sense of the adjustment of the feed (where applicable). For instruments using the subtractive weighing principle check that residual material retained at the feeding device after each load is delivered, is negligible relative to limits of error. switch-on for at least five hours, and at least sixteen hours atter the temperature and damp heat tests have been performed. Test duration : Twenty eight days or over the period necessary for the conduct of the performance tests, whichever is less. Time t (days) between tests: 0.5 S: t S: 10. Test load : a static test load near maximum capacity (Max); the same test weights shall be used throughout the test. The variation In the indication of the test load shall not exceed 1/ 2 the absolute value of the mpe for influence factor tests paragraph 2(4) for the test load a pp lied on any of the (n) tests conducted. n .2'..8. If the test results indicate a trend more than half the permissible variation specified above, conduct additional tests until the trend comes to rest or reverses itself, or until the error exceeds the maximum permissible variation. None required. Verified mass standards. Adjust the EUT as close to zero indication as practicable before each test. Stabilize all factors at nominal reference conditions. If the Instrument Is provided with automatic zero-setting It shall not be In operation.Applythe test load (or simulated load) and record the following data :? (a) date and time (b) temperature (c) barometric pressure (d) relative humidity lt74 4/711..- t zi o Precondition : Test equipment : Number of tests {n): · Condition of the EUT : I 478 THE 'GAZETTE ;OF INDIA: EXTRAORDINARY [PART!I-SEC 3(i)] Number of fills [para 6(3)] : Correction devices [paragraph 6(2)(1)] : Mass of test loads and fills [paragraph 6(2)] : Types of loads [paragraph 5(3Xi)and paragraph 6(2)(a)] : (a) Separateverification method : the separate verification method Is as defined In paragraph 6(5)(1). (b) Integral verification method: the integral verification method Is as defined in paragraph 6(5)(11). (iii) Procedure for metrologicel material tests STEPS: (1) Set up the instrument In accordance with paragraph 6(2) (d) and 6(2)(i). (2) Select a preset value for the fill and set the load value if different from the fill, In accordance with paragraph 6(2). Record the indicated preset value. (3) Run the instrument to produce a number of fills as specified in paragraph 6(3). (4) Weigh all the fills by one of the methods In paragraphs 6(5)(i) or 6(5)(ii). (5) Calculate the average value of all the fills In the test and the preset value error [paragraph 2(3)]. (6) Calculate the deviation of each fill from the average paragraph [2(2)]. (7) Repeat stages (2) to (6) for other loads as specified in paragraph 6(2). Concerning paragraph 6(7) : The result of weighing the test fill on the control instrument shall be considered as the conventional true value of the test fill. Concerning Paragraph 6(8) : The deviation for automatic weighing used to determine compliance of each fill with the maximum per· mtsslble deviation for automatic weighing [paragraph 2(2)] shall be the difference between the conventional true value of the mass of the test fill as defined in paragraph 6(7) and the average value of all the fills in the test. Concerning paragraph 6(9) : The preset value error for automatic The materials used as the test load shall be as specified in paragraph 6(2) (a). The mass of the test loads and fills shall be as specified in paragraphs 6(2) (a, band c), Adjustments [paragraph 6(2) (d)] :The adjustments shall be set as specified in paragraph 6.(2) (d). Any correction device shall be operated as specified in paragraph 6(2)(i). The number of fills shall be as specified in Paragraph 6(3). (ii) Methods for metrological material tests (paragraph 6(5)] One of the following verification methods shall be used: (ii) Load receptoi: [paragraph 3(6)] For instruments·thatweigh material in a separate lcedreceotor.prlor to discharge to a :·container, check ·that 'the :residual materlal·retalned at the load receptor·after each dlschai:ge, is :negligible ·,relative to limits·ofcerror. Check-.that,manual discharqe.of the load receptor.ls.notposslbte during automatic operation. (2) Material tests. at Initial verification {pilragraph S(J){ii)(b) and par.agrtJph.5(3)] Metrologlcaltests with -material shall be done on a complete Instrument, fully.assembled and fixed In the position In •which It is intended to be used and as specified in paragraph S(l)(ii)(b). The accuracy class (or classes) shall be determined from .the results, (i)Requlrements formetrologica/ material tests [ 'lT'T II - i;;ri:s 3 ( i ) ] 479 weighing used to determine com­ pliance with . paragraph 2(3) shall be the difference between the average value of the conventional true value of the mass of the test fills, as defined In para 6(7) and the preset value for the fills. (iv)DetermlNJtlon of accuracy class [paragraph S(2}{v)J (1) For each preset value of the test fill, determine the preset value error (i.e. the setting error, se) and the maximum permissible preset value error for class X(l), mpse : l Then calculate [se/mpse ] for each preset value of the test fill. 1 (2) For each preset value of the test fill determine the maximum actual deviation from the average (md) and the maximum permissible deviation from the average for class X(l), mpd . l Then calculate md/mpd for each preset value of the test fill. 1 · (3) From (1) determine the maximum value of [se./mpse ], [se/mpse J max l l (4) From (2) determine the maximum value of md/mpd 1 [md/mpd ] max. 1 l (5) Determine the accuracy class oo such that (x) > [se/mpse ] max l and (x) > [md/mpd J max I and (x) = 1 x 10k,2 X 10k,or 5 X 10k, the Index k being a positive or negative whole number or zero. SEVENTH SCHEDULE HEADING-E DISCONTINUOUS TOTALIZING AUTOMATIC WEIGHING INSTRUMENTS (TOTALIZING HOPPER WEIGHERS) PART I 1. General definitions (1) Weighing instrument A measuring Instrument that serves to determine the mass of a load by using the action of gravity. According to its method of operation, a weighing instrument is classlfJed as automatic or non­ automatic . (2) Automatic weighing instrument An Instrument that weighs without the intervention of an operator and follows a predetermined programme of automatic processes characteristic of the instrument. (3) Discontinuous totalizing automatic weighing instrument (totaliZing hopper weigher) An automatic weighing Instrument that weighs · a bulk product by dividing It into discrete loads, determining the mass of each discrete load in sequence, summing the weighing results and delivering the discrete loads to bulk. (4) Electronic instrument An instrument equipped with electronic devices. (5) Control instrument A non-automatic weighing Instrument used to determine the mass of the product used as the test load during material tests. 2. Construction Note : Jn this Part and Part II, the term "device" is applied to any part which uses any means to perform one or more specific functions. (1) Load receptor The part of the instrument intended to receive the load. (2) Electronic parts (I) Electronic device A device comprised of electronic sub­ assemblies and performing a specific function. An electronic device is usually manufactured as a separate unit and Is capable of being Independently tested. (Ii) Electronic sub-assembly A part of an electronic device comprised of electronic components and having a recognizable function of its own. (iii) Electronic component The smallest physical entity that uses electron or hole conduction in semi­ conductors, gases or In a vacuum. (3) Indicating device The part of the instrument that displays the value of a weighing result in units of mass. (i) Totalization indicating device The part of the instrument that indicates 480 ,THECGAZETif.E ,OF INDIA: EXTRAORDINARY [PARTII-SEC. 3(i)) the sum of consecutive loads weighed and discha_rgedto:bulk. (a) Princlpaltatalization· indicating device The part.of the instrumenttnatlnolcates the surnrof all.the loadswelqhed and di sch a rged,to .bulk. (b) Partial tatallzation.indicating device The part of theinstrument that indicates the sum ,of a ,limited number of consecutlvelloads.dellvered to bulk. (c) Supplementary .totalization indicating device An indicating.device-with a scale interval greater than ,that of the principal totalizatlon ·indicating device and indicating the sum of consecutive loads weighed over a fairly long period of time. (ii)Control indicating device An indicati11gdevice that enables the use of the instrument as a control instrument to weigh discrete loads for control purposes. (4) Ancillarydevices (i) Zero-setting device The means used to set the weight indicating device to zero when the load receptor Is empty. (a) Non-automatic zero-setting device A zero-setting device that must be operated manually. (b) Semi-automatic zero-setting device A zero-setting device that operates automatically following a manual command. (c) Automatk zero-setting device A zero-setting device that operates automatically and without the Intervention of an operator. (ii) Printing device The means to print the value of each discrete load weighed in the load receptor, or the sum of consecutive loads weighed and discharged to bulk or both. 3. Metrologlcal characteristics (1) Scale-interval A value expressed in units of mass that is the difference between (a) the values corresponding to two consecutive scale marks for analogue indication, or (b) two consecutive indicated values for digital indication. (I) Totalization scale Interval (dtl The scale interval of a principaltotalizatlon Indicating device. (II) Control scale interval (d) The scale interval on a control indicating device. · (2) Weighing cycle The sequence of weighing operations that includes the following :- (I) one delivery of a load to the load receptor, (II) a single weighing operation, (Ill) the discharge to bulk of a single discrete load. (3) Automatic weighing range The range from minimum capacity to maximum capacity. (i) Maximum capacity (Mex) The largest discrete load that can be weighed automatically. (ii) Minimum capacity (Min) The smallest discrete load that can be weighed automatically. (iii) 11Jrgetload The' preset value of the load in the load receptor that causes the flow to stop In each weighing cycle. (4) Minimum totsttzed /o?d(?minl The value of the smallest bulk load that can be totallzed without exceeding the maximum permissible error when the automatic operation is comprised of discrete loads, each within the automatic weighing range. 3(5) Warm-up time The time between the moment that power Is applied to an instrument and the moment at which the instrument is capable of complying with the requirements. 4. Indications and errors (1) Methods of indication (I) Analogue indication An indication allowing the determination of an equilibrium position to a fraction of the scale interval. [qpr [I-? 3(i)] 481 (ii) Digital Indication An Indication In which the scale marks are a sequence of aligned figures that do not permit Interpolation to a fraction of a scale interval. (2) Errors (i) Error (of Indication) The Indication of an instrument minus the (conventional) true value of the mass. (ii) Intrinsic error · The error of an instrument under reference conditions. (iii) Initial Intrinsic error The Intrinsic error of an instrument as determined prior to perfonnance tests and durablllty evaluations. (iv) Fault The difference between the error of indication and the intrinsic error of a weighing instrument. Note 1 : Principally, a fault is the result of an undesired change of data contained In or flowing through an electronic Instrument. Note 2 : From the definition it follows that in this heading a "fault" Is a numerical value. (v) Significant fault A fault greater than dt, The following are not considered to be significant faults, namely :- (a) faults that result from simultaneous and mutually independent cause in the Instrument or in Its checking faclllty, (b) faults that imply the Impossibility of performing any measurement, (c) transitory faults that are momentary variations in the indications which cannot be interpreted, memorized or transmitted as a measurement result, and (d) faults that are so serious that they will Inevitably be noticed by those Interested in the measurement. (vi) Span stability The capability of an Instrument to maintain the difference between the indication of weight at maximum capacity and the Indication at zero within specified limits over a period of use. '-/74 c,071,_,2, (vii) Maximum span stability error A span stability error greater than one half' of the absolute value of the maximum permissible error applicable to the load. 5. Influences and reference conditions (1) Influence quantity A quantity that is not the subject of the measurement but which influences the value of the measurand or the indication of the Instrument. (i) Influence factor . An Influence quantity having a value within the specified rated operating conditions of the instrument. (ii) Disturbance An influence quantity having a value that falls within the limits specified in this International Recommendation but that falls outside the rated operating conditions of the instrument. (2) Rated operating conditions Conditions of use which give the ranges of the influence quantities for which the metrologlcal characteristics are intended to lie within the specified maximum permissible errors. CJ) Reference conditions A set of specified values of Influence factors fixed to ensure valid inter-comparison of the results of measurements. 6. Tests (1) Material test A test carried out on a complete instrument using the type of material that it is Intended to weigh. (2) Simulation test A test carried out on a complete instrument or part of an Instrument in which any part of the weighing operation is simulated. (3) Performance test A test to verify that the equipment under test (EUT) Is capable of accomplishing its intended functions. (4) Span stability test A test to verify that the EUT is capable of maintaining Its performance characteristics over a period of use. PART II 1. General {l)Scope This specification specifies the requirements and 482 . :THE· GAZETi[E •OF INDIA: EXTRAORDINARY [PARTII-SEC. 3(i)} TABLE 2 + l.Odt 500 < m < 2000 + 1.5 dt 2000 < m < 10000 + 0.5 dt O < m < 500 1000 x dt for class· 0.2 Instruments, 400 x dt for class 0.5 instruments, 200 x dt for class 1 Instruments; and 100 x dt for class 2 Instruments. Example : maximum capacity = 1000 kg minimum capacity = 200 kg totalization scale Interval = 0.2 kg (see paragraph 2.4) . accuracy class of Instrument = 0.5 Emin 400 x 0.2 = 80 kg But to satisfy the second indent above : Emin ? min = 200 kg Therefore, in this example the minimum value of the minimum totalized load Is 200 kg. (The values used in this example are not intended to be typical.) (6) Agreement between indicating and printing devices For the same load, the difference between the Digital indications and printed results shall be corrected for the rounding error, and the error shall be determined with an accuracy of at least 0.2 dt, (3) Form of the scale interval The scale intervals of the indicating and printing devices shall be in the form of 1 x 10k,2 x 10k, or 5 x 10k , "k" being a positive or negative whole number 'or zero. (4) Totalization scale interval (dt) The totalization scale Interval shall be : (a) not less than 0.01 % of maximum capacity;and (b) not greater than 0.2 % of maximum capacity. (S)Minimum value of minimum totalized load(Lm1n) The minimum totalized load shall not be less than : (a) the value of the load. for which the maximum permissible error for automatic weighing on initial verification is equal to the totalization scale interval (dt); and (b) the minimum capacity (Min). Note : It results from the first indent above that the maximum permissible error on initial verification (mpe in the follow Ing example) for a load equal to I:min shall not be less than dt, Therefore, using table 1, l:mfn shall not be less than: + 1.0 % + 2.0 % + 0.25 % + 0.5 % ± 0.10 % · ± 0.2 % Verification Inspection Percentage of the mass of the totalized load 2 + 1.00 % 1 + 0.50 % 0.2 0.5 test methods for. discontinuous totalizing automatic weighing instruments {totalizil}g,hopper welghers), [hereafter referred. to.as "mstrurnentstl. It is intended to .provlde -standerdlzed requirements and'test procedures to -evaluate the metrological endttechntcal ·characteristics of an Instrument in a unlform·andttraceable way. (Z) Application This specification appllesto instruments having a load receptor ln·the'.form·cif,a:hopper. This Part doesnotapply.tothe.following types of Instruments :- (a) "welghll}g,ln,motion",instwments, (b) instruments thattotalize the bulk load by multiplying the weight of a preset constant load by;the number of weighing cycles. 2, Hetrologicahrequlrements (1) Accuracy classes Instruments shall be divided into four accuracy classes as follows :- 0.2, 0:5 1, 2 (2) Maximum permtssibleerrors (i) Automatic weighing The maximum permissible errors for each accuracy class shall be the appropriate values in Table 1 given below rounded to the nearest totalizatlon scale interval. Maximum permissible errors apply to loads not less than the minimum totaiized load (Iminl· · TABLE 1 (ii) Influence quantities The maximum permissible errors applied in tests to assess the effect of influence quantities shall be as specified in Table 2 below:- Maximum permlsslble errors Loed (m) expressed in totallzatlon scale intervals · Accuracy class ?._;::: -===- ['1T'TII-? 3(i)] 483 weighing results provided by any two devices having the same scale Interval shall be as follows :- (a) zero for dlgltal indicating or printing devices; (b) not greater than the absolute value of the maximum permissible error for automatic weighing for analogue devices. (7) Influence qu11ntltles (i) Static temperature Instruments shall comply with the appropriate metrological and technical requirements at temperatures from - 100c to+ 450c. For special applications, however, the limits of the temperature range may differ from the above provided that this range is not less than 30°C and Is specified in the descriptive markings. Instruments shall be tested In accordance with the static temperatures test in as specified In paragraph 8(3)(1) of Annex A. (ii) Mains power supply (AC} Instruments that are powered by an AC supply shall comply with the appropriate metrologlcal and technical requirements when operated under variations of voltage from - 15 % to + 10 % of the value marked on the instrument. Instruments shall be tested In accordance with the mains power supply (AC) test as specified In paragraph 8(3)(111)of Annex A. (iii) Battery power supply (DC) Instruments that are powered by a DC supply shall comply with the appropriate metrologlcal and technical requirements in accordance with paragraph 4(3)(viii). Instruments shall be tested in accordance with the battery power supply (DC) test as specified In paragraph 8(3)(1v)of Annex A. 3. Technical requirements (1) Suitability for use Instruments shall be designed to suit the method of operation and the materials for which they are intended. (2) Security of operation (i) Accidental ma/adjustment Instruments shall be constructed so that a maladjustment likely to disturb their metrological performance cannot normally take place without the effect being easily detected. (ii) Purging of load receptor The design of the load receptor and the operation of the Instrument shall be such that the weighing results are not adversely affected by any variation in the quantity of the load remaining In the load receptor after discharge during a weighing cycle. (Iii) Automatic weighing conditions An automatic operation shall be Interrupted, printing shall be prevented or marked and a warning signal shall be given in the following cases :- (a) if the maximum capacity (Max) has been exceeded by more than 9 d; and (b) if the value of the load to be weighed and discharged to bulk is less than minimum capacity (Min), unless processed as the last discrete load of the transaction. (Iv) Operational adjustments It shall not be possible to make operating adjustments nor to reset the indicating devices during an automatic weighing operation, with the exception of the possibility to interrupt the weighing cycle during testing as described in paragraph 6.3.1. (v) Dust extraction The operation of a dust extractor shall not affect the result of the measurement. (vi) Zero-setting device Instruments that do not tare-weigh after each discharge shall be provided with a zero-setting device. An interlock shall be provided to stop an automatic operation If the zero indication varies by: (a) 1dt on instruments with an automatic zero-setting device; or (b) O.Sdt on instruments with a semi­ automatic or non-automatic zero­ setting device. A zero-setting device shall be capable of setting zero to± 0.25 of the smallest scale interval of all the l - - . - ------ - -- --- ------"-?--- ------------------ 484 THE •,GAZETTE OF INDIA: EXTRAORDINARY [PARTfl-SEC. 3(i)] ·Indicating devices of the instrument .:and have.a ra?ge of,ac;IJustmentnot ··exceeding 4% of maximum capacity. (vii) Fraudulent use Instruments shall not have characteristics likely-tofacilitate theirJrauduient use. (3) Instruments with control indicating devices For an instrument ·with a control indicating device, the load ·receptor shall have the facility to support a quantlty.ohtandard weights ln accordance with Table 3 givend,elow::- JABl:E 2 (4) Totalization Indicating and printing devices Instrumentsshall lndude a principal totalization Indicating device end may include a supplementary totalization indicating device, partial totallzation indicating devices, and printing devices. On an instrument equipped with a printing device, the following shall apply :- (a) It shall not be possible to reset the principal totalization indicating device to zero unless the printing device automatically prints the last total indicated before resetting to zero. (b) An automatic printout of the last total shall be generated if the automatic operation is interrupted and operating adjustments can be made. (i) Qua/tty of indication A totallzation indicating and printing device shall allow reliable, simple and unambiguous reading of the results by simple juxtaposition and shall bear the name or symbol of the appropriate unit of mass. (ii) Scale interval Except for a supplementary totallzation indicating device, the scale Intervals of all totalization Indicating devices shall be the same. {iii)Supplementary totettzetton Indicating devices The scale interval of a o maximum capacity Max = ... g or kg or t o minimum capacity Min = ... g or kg or t supplementary totalization indicating device shall be at least equal to ten times the totallzatlon scale interval indicated In the descriptive markings. (iv) Combined indicating devices Two or more types of indicating devices may be combined so that the indication required can be displayed on demand provided that it is clearly Identified. (S) Ancillary devices Ancillarydevices shall not affect the indicated totallzation(s) representing a bulk load for a transaction. (6) Sealing Components that are not intended to be adjusted or removed by the user shall either be fitted with a sealing device or be enclosed. When enclosed, it shall be possible to seal the enclosure. (7) Descriptive markings Instruments shall bear the following markings:­ (i) Marking shown in full o identification mark of the manufacturer o identification mark of the importer (if applicable) , serial number and type designation of the instrument o nature of product o control scale interval (if applicable) .... g or kg or t o Electrical supply voltage .. , V o Electrical supply frequency .. , Hz o Working fluid pressure (if applicable) kPa or bar o Operational speed Max and min (ii) Markings o pattern approval sign in accordance with national requirements 0.2, 0.5, 1 or 2• accuracy class Minimum quantity of standarti weights Max 5 t 20 °/o Max 10 t Max? 5 t 5 t < Max ? 2S·t 25 t < Ma x ·?'50 t 50t<Max Maximum caf)dcl/y (Max) ['WT II-? J(i)J 485 • minimum totalized load •min = ... g or kg or t • totallzation scale interval dt= .. gorkgort • Output per hour at maximum operating speed • Model approval mark (iii) Presentstton of descriptive markings Descriptive markings shall be Indelible and of a size, shape and clarity that permit legibllltyunder rated operating conditions. Markings shall be grouped together in a clearly visible place on the Instrument, either on a descriptive plate fixed near the Indicating device or on the Indicating device Itself. It shall be possible to seal the plate bearing the markings, unless the plate cannot be removed without being destroyed. (8) Verification marks (i) Position Instruments shall have a place for the application of verification marks. The followingapplies for this place : (a) the part on which the marks are located cannot be removed from the Instrument without damaging the marks; (b) the place shall permit the easy appllcatlon of the marks without changing the metrologlcal qualities of the instrument; and (c) the marks shall be visible without requiring that the instrument or its protective covers be moved when it Is In service. (ii) Mounting Instruments required to bear verification marks shall have a verification mark support located as specified above, which shall ensure theconse'rvation of the marks as follows:- (a) When the mark is made with a stamp, the support may consist of a strip of lead or any other material with similar qualities inserted into a plate fixed to the instrument or in a cavity bored into the instrument; (bl When the mark consists of an adhesive transfer, a space shall be provided for this purpose. 4. Requirements for electronic Instruments Electronic instruments shall comply with the following requirements, in addition to the applicable requirements of all other clauses. (1) General requirements (i) Rated operating conditions Electronic instruments shall be designed and manufactured so that they do not exceed the maximum permissible errors under rated operating conditions. (ii) Disturbances Electronic instruments shall be designed and manufactured so that when they are exposed to disturbances, either- (a) significant faults do not occur; or (b) significant faults are detected and acted upon. Note : A fault equal to or less than the value specified in paragraph 4(2)(v) of Part I (1 dtl is allowed Irrespective of the value of the error of indication. (iii) Durability The requirements In paragraphs 4(1)(1) and 4( l)(ii) shall be met durably In accordance with the intended use of the Instrument. (iv) Evaluation for compliance A pattern of an electronic instrument Is presumed to comply with the requirements in 4(1)(1), 4(1)(11) and 4(1)(iii) if it passes the examination and tests specified in Annex A. (2) Application of requirements for disturbances (i) The requirements In paragraph 4(1)(1i) may be applied separately to : (a) each individual cause of significant fault, and/or (b) each part of the electronic instrument. (ii) The choice as to whether to apply paragraphs 4(1)(1i)(a) or (b) is left to the manufacturer. (3) Functional requirements (I) Acting upon a significant fault When a significant fault has been detected, a visual or audible indication -- -?-? - 486 .THE GAZETTE OF ,INDIA: EXTRAORDINARY [PARTII-SEC. 3(i)] shall be provided and shall .continue until the user takes action .or .the fault disappears. Means .shall be .provtded to .retain any totallzedloed inforrnatiorncontalned in the instrumentwhen a significant.fault occurs. (ii) Switch-onprocedure Upon switch-on .(in thecase of electronic instruments permanently.connected to the mains etswltch-onot indication), a special procedure .shall :be ·performed that indicates ·all the relevant signs of the indicator :in :their active and non-active states for a sufficient time to be easily observed by the operator. (iii) Influence quantities An electronic instrument shall comply with the requirementsparagraph 2(7) and in addition •It shall maintain its metrological and technical characteristics at a relative humidityof 85 % at the upper limit of the temperature range of the instrument. · (iv) Disturbances When an electronic instrument is subjected to the disturbances specified in Annex A, either of the following shall apply : (a) the difference between the weight Indication due to the disturbance and the indication without the disturbance (intrinsic error) shall not exceed the value specified in paragraph 4(2)(v) of part I (1 dtl (b) the instrument shall detect and act upon a significant fault. (v) Warm-up time During the warm-up time of an electronic instrument, there shall be no indication or transmission of the weighing result and automatic operation shall be Inhibited. (vi) Interface An instrument may be equipped with an interface permitting the coupling of the instrument to external equipment. When an Interface Is used, the instrument shall continue to function correctly and its metrologlcal functions shall not be influenced. (vii) Mains power supply (AC} An Instrument that operates from the mains shall, in the event of a power failure, ?t -- retain the metrologlcal information contained in the Instrument at the time of failure for at least 24 hours. A switch­ over to an emergency power supply shall not cause a significantfault. (viii) Battery power supply (DC) An instrument that operates from a battery power supply shall, whenever the voltage drops below the manufacturer's specified value, either continue to function correctly or automatically be put out of service. (4) Examination and tests The examination and testing of an electronic weighing Instrument is intended to verify compliance with the applicable requirements of these specifications and especially with the requirements in paragraph 4. (i) Examination An electronic weighing instrument shall be examined to obtain a general appraisal of the design and construction. (II) Performance tests An electronic weighing instrument or electronic device, as appropriate, shall be tested as specified in Annex A to determine its correct functioning. Tests are to be conducted on the whole instrument except when either the size or confiquratlonor both of the instrument does not lend itself to testing as a unit. In such cases, the separate electronic devices shall be subjected to testing. It Is not intended that electronic devices be further dismantled for separate testing of components. In addition, an examination shall be carried out on the fullyoperational weighing instrument or, if necessary, on the electronic devices in a simulated set· up that sufficiently represents the weighing instrument. The equipment shall continue to function correctly as specified in Annex A. (iii) Span stability tests The instrument shall be subjected to span stability tests at various intervals, I.e. before, during and after being subjected to performance tests. When the instrument is subjected to span stability test specified in paragraph 9 of Annex A- ['WT II-1W'6 3(i)] 487 (a) the maximum a!!owable variation in the errors of indication shall not exceed half the absolute value of the maximum permissible error specified In paragraph 2(2)(ii), Table 2 for the test load applied on any of the n measurements; (b) where the differences of the results Indicate a trend more than half the allowable variation specified above, the test shall be continued until the trend comes to rest or reverses itself, or until the error exceeds the maximum allowable variation. 5. Metrologlcal controls (1) Pattem evaluation (i) Documentation The application for pattern evaluation shall include documentation comprising : (a) metrological characteristics of the Instrument; (b) a standard set of specifications for the Instrument; (c) a functional description of the components and devices; (d) drawings, diagrams and general software information (Ifapplicable), explaining the construction and operation; (e) any document or other evidence demonstrating that the design and construction of the Instrument complies with the requirements of these specifications. (ii) General requirements Pattern evaluation shall be carried out on at least one and normally, not more than three instruments that represent the definitive pattern. At least one of the instruments shall be completely installed at a typical site and at least one of the instruments or the major component of an instrument shall be submitted in a form suitable for simulation testing in a laboratory. The evaluation shall consist of the tests specified in paragraph S(l)(iii). (iii) Pattern evaluation tests (a) Instruments shall comply with : • The metrological requirements in paragraph 2,· particularly with reference to maximum permissible errors, when the instrument Is operated in accordance with the manufacturer's specifications for range and product(s); • The technical requirements in paragraph 3 including the requirement for security of operation in paragraph 3(2). Additionally electronic Instruments shall comply with the requirements in paragraph 4. (b) The appropriate metrological authority : • shall conduct the tests in a manner that prevents unnecessary commitment of resources; • shall permit, when the same instrument Is involved; the result of these tests to be assessed for initial verification; is advised to accept, with the consent of the applicant, test data obtained from other metrological authorities without repeating the tests; • shall ensure that an instrument that can be operated as a non-automatic weighing Instrument meets the relevant requirements for class III or class IV of non-automatic weighing instruments. (c) Material tests Instruments shall be subjected to in· situ material tests In accordance with either the separate verification method as specified in paragraph 6(2)(ii) of Annex A or the integral venrlcation method as specified In paragraph 6(2)(1il) of Annex A Where the material test is conducted using the integral control instrument the integral verification method weighing test in paragraph 6(2)(iii)(a) of Annex A shall be performed. In-situ material tests shall be carried out as follows : • in accordance with the descriptive markings; • under the rated operating conditions for the instrument; • not less than three material tests shall be conducted, one at minimum 488 THE GAZETTE OF INDIA: EXTRAORDINARY [PART11--SEC. 3(i)) · .. capacity, one at maximum capacity .and one at.dose .to the ·minimum totalized load :(Smin); • each test shall be conducted at the maximum .rate of ,weighing cycles per·hour; . • with a test load representative of the : range and type otproducts for which the Instrument is 'likely to be used .or a product for which the 'Instrument is specified to be used; • ,with a quantity of material not less than the minimum totalized load . (Smln) marked on the instrument; • when the quantity of material equal to the minimum totalized load (Smin) can be totalized in less than five weighing cycles, the following additional material tests shall be conducted, five cycles each at maximum capacity (Max) and five cycles at minimum capacity (Min); • equipment near the automatic weighing instrument, including conveyors, dust collection systems etc. that are in use when the instrument is in normal operation, shall be in use; • if the Instrument can divert weighed material through alternative discharge facilities, the test program shall be performed for each alternative unless It can be · established that the weigh hopper is not affected for example by different air flow. When a load receptor cannot be loaded with sufficient standard weights to verify and determine the rounding error of the control Instrument indicating device or partial indicating device, then the instrument shall be subjected to material tests by the separate verification method. For this method an appropriately designed control Instrument shall be available so that the material tests can be effectively and efficiently conducted. The error for automatic weighing shall be · the difference between the conventional true value of the mass of the test load as defined In paragraph 6(2)(1i) or 6(3)(iii) as appropriate and the indicated weight observed and recorded as defined in paragraph 6(2)(1) or 6(3)(ii) as appropriate. The maximum permissible error for automatic weighing shall be as specified in paragraph 2(2)(1) Table 1 for initial verification and as appropriate for the class of instrument. (ill) Simulation tests Influence quantities shall be applied during simulation tests in a manner that will reveal an alteration of the weighing result for any weighing process to which the instrument could .be applied, In accordance with : • paragraph 2(7) for all instruments; • paragraph 4 for electronic instruments. When conducting such tests on a load cell or on an electronic device equipped with an analogue component, the maximum permissible error for the device under test shall be 0.7 times the appropriate value specified in Table 2. Note: Since the requirements of this paragraph apply only to the instrument submitted for pattern evaluation and not to those subsequently submitted for verification, the means used to determine the appropriate maximum permissible error or maximum allowable variation has been exceeded will be decided and mutually agreed upon between the Metrological Authority and the applicant. Following are examples of these means : (a) an adaptation of the totalizatlon indicating device to give greater resolution than that of the totalization scale Interval; (b) the use of change point weights; (c) any other means mutually agreed upon. (iv) Provision of means for testing For the purposes of testing, the applicant may be required to furnish the Metrological Authority with the material, handling equipment, qualified personnel, and a control instrument. (v) Place of testing Instruments submitted for pattern approval may be submitted at the following places : (a) the premises of the Metrologlcal Authority to which the application ['WT II-? 3(i)J 489 has been submitted; (b) any other suitable place mutually agreed upon by the Metrologlcal Authority and the applicant. {2}Tests to be carried out during verification and re­ verification (i) Tests Instruments shall comply with the requirements in paragraph 2 [except paragraph 2(7)] and paragraph 3 for any product(s) for which they are Intended and when operated under normal conditions of use. Tests shall be carried out insitu, in a normal Installation. The instrument shall be installed so that an automatic weighing operation will be virtually the same for testing as It Is for a transaction. (a) Non-automatic weighing instru­ ments When an instrument can be operated as a non-automatic weighing instrument, it shall meet the relevant requirements for class III or class IV of non-automatic weighing instruments. (b) Material tests Instruments shall be subjected to in­ situ material tests in accordance with either the separate verification method as specified In paragraph 6(2)(11) of Annex A or the integral verification method as specified in paragraph 6(2)(iii) of Annex A. Where the material test is conducted using the Integral control instrument the integral verification method weighing test in paragraph 6(2)(iii)(a) of Annex A shall be performed. Insltu material tests shall be carried out as follows:- • In accordance with the descriptive markings; • under the rated operating conditions for the instrument; • not less than three material tests shall be conducted, one at minimum capacity, one at maximum capacity and one at close to the minimum totallzed load (•min); • each test shall be conducted at the f..t7 4 c,6) 11- I??, maximum. rate of weighing cycles per hour; • with a test load of products or products for which the instrument is intended; • with a quantity of material not less than the minimum totalized load (•min) marked on the instrument; • when the quantity of material equal to the minimum totalized load (•min) can be totallzed in less than five weighing cycles, the following additional material tests shall be conducted, five cycles each at maximum capacity (Max) and five cycles at minimum capacity (Min); • equipment near the automatic weighing Instrument, including conveyors, dust collection systems etc. that are In use when the instrument ts in normal operation, shall be in use; • if the instrument can divert weighed material through alternative discharge facilities, the test program shall be performed for each alternative unless it can be established that the weigh hopper is not affected for example by different air flow. Testing for the full range of products only needs to be done for one discharge facility. When a load receptor cannot be loaded with sufficient standard weights to verify and determine the rounding error of the control instrument indicating device or partial indicating device, then the Instrument shall be subjected to material tests by the separate verification method. For this method an appropriately designed control instrument shall be available so that the material tests can be effectively and efficiently conducted. The error for automatic weighing shall be the difference between the conventional true value of the mass of the test load as defined in paragraph 6(2)(ii) or paragraph 6(3)(iii), as appropriate and the indicated weight observed and recorded as defined In paragraph 6(2)(1) or paragraph 6(3)(11), as appropriate. The maximum permissible error for automatic weighing shall be as specified 490 THE' GAZETTE <(i)F INDIA: EXTRAORDINARY [PARTll-SEC. 3(i)] in paragraph 2(2)(i) Table 1 .for Initial verification as appropriate for.the class of instrument. (ii) Provlslon.otmeansfor:testlng For the.purposes of.testing, .the.applrcant shall be, required to furntsh with the material, handling equipment, qualified personnel.ard a-control instrument. (3) Tests to.becemea out during inspection Inspection ·shall .be carried out :in accordance with the same provisions as .in paraqraph 5(2) for verification, with the exception that the inspection maximum permissible errors shall 'be applied. 6. Test methods (1) Contro!lnst;ument and test standards The control instrument and standard weights ·used for tests shall ensure the checkln_gof the test load to an error not greater .than : (a) one-third of the maximum permissible error for automatic weighing when the control Instrument or the device used for control purposes Is verified immediately prior to the material test, or (b) one-fifth of the maximum permissible error for automatic weighing in all other cases. Note : When using the integral verification method, a sub-division of the test load is unavoidable and this may also be true when using the separate verification method. When calculating the conventional true value of the mass of the test load, It Is necessary to consider the Increased uncertainty due to sub­ dividing the test load. (2) Separate verification method . With this method, an instrument other than the Instrument being verified is used to determine the conventional true value of the mass of the test load. ' . . (i) Indicated weight A test load shall be weighed as an automatic bulk to bulk weighing operation and the Indicated weight value on the principal totalization indicatingdevice shall be observed and recorded. (ii) Mass of the test load The test load shall be weighed on a control instrument and the result shall be considered as the conventional true value of the mass of the test load. (3) Integral verificationmethod With this method, the instrument being verified is used to determine the conventional true value of the mass of the test load. The Integral verification method shall be conducted by using either of the following : o a partial totallzation indicating device with standard weights to assess the rounding error; or o an appropriately designed control Indicating device. (I) Interruption of automatic operation An automatic weighing operation of a test load shall be initiated following the same procedure. as for weighing bulk to bulk. However, the automatic operation shall be Interrupted twice during each weighing cycle necessary to weigh and discharge a sub-division of the test load. An automatic operation shall not be Interrupted during consecutive weighing cydes if the instrument is installed as an air-enclosed system. (i)(a)Pre-discharge (gross) interrupt After the load receptor has been loaded and the instrument has automatically processed a gross weight, the automatic operation shall be Interrupted. When the load receptor has stabilized, the gross weight indicated or determined by balancing with standard weights shall be recorded and the Instrument switched back to automatic operation. (b) Post-discharge (tare) Interrupt After the load has been discharged and the instrument has automatically processed a tare weight, the automatic operation shall be interrupted. When the discharged load receptor has stabilized, the tare weight indicated or determined by balancing with standard weights shall be recorded and the Instrument switched back to automatic operation. (Ii) Indicated weight The principal totallzatlon indicating device shall be used in obtaining the indicated weight of the test load. (Iii) Mass of the test load For each discharge, the tare weight value subtracted from the gross weight value is ['ll'T II-1s!Us 3(i)] 491 the net weight of the material discharged. A summation of the net welght values of all the discharges in the test load shall be the conventional true value of the mass of the test load.

Previous and next

All provisions of Legal Metrology (General) Rule, 2011

Questions people ask

Is annexure A of Legal Metrology (General) Rule, 2011 still in force?

No repeal of Legal Metrology (General) Rule, 2011 is recorded.