Regulation 8, Joint Electricity Regulatory Commission” (Distribution Code) Regulations, 2010.: STANDING COMMITTEE FOR DESIGN, CONSTRUCTION AND MAINTENANCE PRACTICES

Joint Electricity Regulatory Commission” (Distribution Code) Regulations, 2010. - Regulation 8

Text of regulation 8

STANDING COMMITTEE FOR DESIGN, CONSTRUCTION AND MAINTENANCE PRACTICES

8. STANDING COMMITTEE FOR DESIGN, CONSTRUCTION AND MAINTENANCE PRACTICES.- 1. Standing Committee for design, construction and maintenance practices shall under the chairmanship of the technical Member/Director of the licensee be constituted by the licensee, within one month w.e.f. the commencement of this Code and shall comprise of- (a) the senior most Engineer (Planning) of the licensee (b) the senior most Engineer (Materials Management) of the licensee (c) the senior most Engineer (Design and Planning) of the STU ; and (d) any other person as the licensee may deem appropriate. 2. The Standing Committee shall be an advisory body having perpetual term and shall hold its meeting at least once in each quarter. The Standing Committee shall suggest and make recommendations to the licensee on matters amongst others in the following areas:- (a) to review and suggest the latest practices on design and technical specifications of line materials, meters and metering equipment, service line 41 | P a g e materials, sub-station equipments like transformers, circuit breakers, CT/PT sets etc; (b) to suggest vendor selection and short listing procedures for various equipments and materials being used in bulk; (c) to suggest best industry practices and innovative techniques for construction, operation, maintenance of HT / LT lines and Grid Sub- stations, Pole mounted and other plinth mounted sub-stations etc; (d) to recommend and suggest the latest technology up gradation and process such as IT tools and SCADA and other Control System; (e) to recommend embargo and restrictions on dangerous, unhygienic practices and material from point of view of safety, environmental up-keep and pollution norms. 9. SECURITY STANDARDS 1. The Distribution System shall be planned and maintained so as to fulfill the following security standards except under Force Majeure conditions beyond the reasonable control of the Distribution Licensee. 2. The feeders, either HT or LT, feeding important loads such as hospitals, crematoria, airports, railway stations, and the like shall be planned to have a selective switching system, so that selective switching can be operated to transfer the load on to an alternate healthy feeder. Appropriate safety precautions shall invariably be taken in this regard. In case of failure of the feeder, these switches shall be operated immediately either manually or automatically depending on the importance of the load. 3. The feeders connected to important industries which are very sensitive to interruption of even short duration shall be planned to have automatic switchover to an alternate healthy feeder in case of failure of supply. 4. Loading in any current carrying component of the Distribution System (e.g. Conductors, joints, transformers, switchgear, cables and other apparatus) shall not exceed 75% of their respective thermal limit. 5. The rupturing capacity of the switchgear employed in the system shall have at least 25% more capacity than the short circuit level computed even considering the anticipated future development of the system. 6. Provision shall be made for every HT feeder, either primary or secondary, to manually switch over to the immediately available HT feeder of the same voltage class available in the vicinity. Provision shall be made in the design itself for any HT feeder to share at least 50% of the loads in the adjacent feeder during emergencies. 7. In case of single contingency; failure of any substation equipment controlling any outgoing 11 kV feeder, the load interrupted shall not generally exceed 50% of the total demand on the substation. The Distribution Licensee has to bring it down to 20% within a period of three years. 42 | P a g e 8. There shall be adequate stand by capacity in the system. 9. The design of the Distribution System shall accommodate the arrangements in such a way that the electricity supply need not be interrupted for more than the specified duration as per JERC (Standard of Performance) Regulations 2009 of Licensee in case of breakdown of any distribution transformer. Similarly in case of failure of 11 kV feeders including terminal equipment, the design shall accommodate an arrangement for the power supply not to be interrupted to the extent possible.

Previous and next

All provisions of Joint Electricity Regulatory Commission” (Distribution Code) Regulations, 2010.

Questions people ask

Is regulation 8 of Joint Electricity Regulatory Commission” (Distribution Code) Regulations, 2010. still in force?

No repeal of Joint Electricity Regulatory Commission” (Distribution Code) Regulations, 2010. is recorded.