Rule 24, Delhi Factories Rules, 1950: Thermometers to be maintained in efficient order- Each thermometer shall be maintained at all times during the period of employment in efficient working order, so as to give accurate indications and in particular

Delhi Factories Rules, 1950 - Rule 24

Text of rule 24

Thermometers to be maintained in efficient order- Each thermometer shall be maintained at all times during the period of employment in efficient working order, so as to give accurate indications and in particular

24. Thermometers to be maintained in efficient order- Each thermometer shall be maintained at all times during the period of employment in efficient working order, so as to give accurate indications and in particular :- (a) the wick and the muslin covering of the wet bulb shall be renewed once a week; (b) the reservoir shall be fitted with water which shall be completely renewed once a day. The Chief Inspector may direct the use of distilled water or pure rain water in any particular mill or mills in certain localities; (c) no water shall be applied directly to the wick or covering during the period of employment. 25. An inaccurate thermometer not to be used without fresh certificate- if an Inspector gives notice in writing that a thermometer is not accurate it shall not, after one month from the date of such notice, be deemed to be accurate unless and until it has been re-examined as prescribed and afresh certificate obtained which certificate shall be kept attached to the Humidity Register. 26. Hygrometer not to be affixed to wall etc., unless protected by wood- (1) No hygrometer shall be affixed to a wall, pillar or other surface unless protected therefrom by wood or other non-conducting material at least half an inch in thickness and distant at least one inch from the bulb of each thermometer . (2) No hygrometer shall be fixed at a height of more than 5 feet 6 inches from the floor to the top of thermometer steam or in the direct draughts from a fan, window or ventilating opening. 27. No reading to be taken within 15 minutes of renewal of water- No reading shall be taken for record on any hygrometer within 15 minutes of the renewal of water in the reservoir. 28. How to introduce steam for humidifications- In any room in which steam pipes are used for the introduction of steam for the purpose of artificial humidification of the air the following provisions shall apply- (a) The diameter of such pipes shall not exceed two inches and in the case of pipes installed after 1 st August, 1950 the diameter shall not exceed one inch; (b) Such pipes shall be short as it reasonably practicable; (c) All hangers supporting such pipes shall be separated from the be pipes by an efficient insulator not less than half an inch thickness (d) No uncovered jet from such pipe shall project more than 4-1/2 inches beyond the outer surface of any cover; http://labour.delhigovt.nic.in/act/details_rules/the%20delhi%20factory%20rules,%201950//factoryrules/ (e) The steam pressure shall be as low as practicable and shall not exceed 70 Ibs. per square inch; (f) The pipe employed for the introduction of steam into the air in a department shall be effectively covered with such non-conducting material, as may be approved by the Inspector in order to minimise the amount of heat radiated by them into the department. Rules 29 to 33 prescribed under sub-section (4) of Section (17) 29. Lighting-application and commencement- (1) Subject as in these Rules provided, Rules 29 to 33 shall apply to factories in which persons are being regularly employed in a manufacturing process or processes for more than 48 hours a week, or in shifts, provided that nothing in these Rules shall be deemed to require the provision of lighting of a specified standard in any building or structure so constructed that, in the opinion of the Chief Inspector, it would not be reasonably practicable to comply with such requirements. (2) Rules 29 to 33 shall come into force, in respect of any class or description of factories, on such dates as the Chief Commissioner may, by notification in the Official gazette, appoint in this behalf. 30.Lighting of Interior parts- (1) The general illumination over these interior parts of a factory where persons are regularly employed shall be not less than 6 feet candles measured in horizontal plane at a level of 3 feet above the floor : Provided that in any such parts in which the mounting height of the light source for general illumination necessarily exceeds 25 feet measured from the floor or where the structure of the room or the position or construction of the fixed machinery or plant prevents the uniform attainment of this standard, the general illumination at the said level shall not be less than 2 feet candle and where work is actually being done the illumination shall be not less than 6 feet candles. (2) The illumination over all other interior parts of the factory over which persons employed pass shall, when and where a person is passing, be not less than 0.5 foot candles at floor level. (3) The standard specified in this Rule shall be without prejudice to the provision of any additional illumination required to render the lighting sufficient and suitable for the nature of the work.

Previous and next

All provisions of Delhi Factories Rules, 1950

Questions people ask

Is rule 24 of Delhi Factories Rules, 1950 still in force?

No repeal of Delhi Factories Rules, 1950 is recorded.