Regulation 228, Indian Boiler Regulations, 1950.: Foundations ol Looo-type Boiler Fireboxes
Indian Boiler Regulations, 1950. - Regulation 228
Text of regulation 228
Foundations ol Looo-type Boiler Fireboxes
228. Foundations ol Looo-type Boiler Fireboxes.—Whero tho firo-box roof in loco-
type boilers it* not stayed direct to the external casing crown or to girders oarried
by tho casing or is not connected to tho casing by slings in accordance with Regula-
tion 229 (<;) and the whole load on the firebox vertically is borne by the bottom
parts of the firobox where connected to tho external casing the working pressure for
the parts, if plates are joggled out to meet tho casing or if an ogeo ring is fitted,
shall not exceed that found by the following formula :—•
70 (t—1)« X (L+W)
W.P.=— — Eqn. (63)
t is the thioknoss of the joggled firobox sido plates or fire hole plate (whiohever
is leas), ogoo ring in 32nds of an inch,
L is the length of firebox casing in inchos measured between tho water sides of
front ond plate and saddle plate at the foundation seam,
W is the width of firobox oasing in inohes measured betweon the water sides
casing sido plates at the foundation seam,
Wx is the width of firebox in inches measured botwoen the water sides of firo
box sido plates at the commoncoment of curvature abovo jogglod part or where it
joins the ogee ring,
Whero only a comparatively narrow strip of tho firebox roof is stayod directly
to the oasing crown the area so stayed shall be doduoted from the area roprosented
by L X W in tho bottom line of tho formula thus, (L X W—A) (W—Wx) and so used
in Equation (63) in determining the working pressure for the parts, "A" being the
area in square inches of the part of roof supported by tho oasing crown.
227. Cross Tubes.—The working pressure of the tubes shall be determined by
tho following formula :•—•
200(t—7)
W. P. =- Eqn. (64)
W. P . = Working pressure in lbs. por sq. inch,
t = minimum thickness in 32nds of an inoh,
D=J the internal diameter in inchos of tho cross tube.
228. Uptakes ol Vertical Boilers.—The working pressure for uptake tubes of
vertical boilors shall bo determined by Eqns. 57 and 58 but only half the least pressure
so found is to be allowed for uptake tubos.
SUPPORTS FOR COMBUSTION CHAMBER AKX> FIREBOX CROWN
Previous and next
Questions people ask
Is regulation 228 of Indian Boiler Regulations, 1950. still in force?
No repeal of Indian Boiler Regulations, 1950. is recorded.