Foundations ol Looo-type Boiler Fireboxes

228. Foundations ol Looo-type Boiler Fireboxes.—Whero tho firo-box roof in loco- type boilers it* not stayed direct to the external casing crown or to girders oarried by tho casing or is not connected to tho casing by slings in accordance with Regula- tion 229 (<;) and the whole load on the firebox vertically is borne by the bottom parts of the firobox where connected to tho external casing the working pressure for the parts, if plates are joggled out to meet tho casing or if an ogeo ring is fitted, shall not exceed that found by the following formula :—• 70 (t—1)« X (L+W) W.P.=— — Eqn. (63) t is the thioknoss of the joggled firobox sido plates or fire hole plate (whiohever is leas), ogoo ring in 32nds of an inch, L is the length of firebox casing in inchos measured between tho water sides of front ond plate and saddle plate at the foundation seam, W is the width of firobox oasing in inohes measured betweon the water sides casing sido plates at the foundation seam, Wx is the width of firebox in inches measured botwoen the water sides of firo box sido plates at the commoncoment of curvature abovo jogglod part or where it joins the ogee ring, Whero only a comparatively narrow strip of tho firebox roof is stayod directly to the oasing crown the area so stayed shall be doduoted from the area roprosented by L X W in tho bottom line of tho formula thus, (L X W—A) (W—Wx) and so used in Equation (63) in determining the working pressure for the parts, "A" being the area in square inches of the part of roof supported by tho oasing crown. 227. Cross Tubes.—The working pressure of the tubes shall be determined by tho following formula :•—• 200(t—7) W. P. =- Eqn. (64) W. P . = Working pressure in lbs. por sq. inch, t = minimum thickness in 32nds of an inoh, D=J the internal diameter in inchos of tho cross tube. 228. Uptakes ol Vertical Boilers.—The working pressure for uptake tubes of vertical boilors shall bo determined by Eqns. 57 and 58 but only half the least pressure so found is to be allowed for uptake tubos. SUPPORTS FOR COMBUSTION CHAMBER AKX> FIREBOX CROWN

Previous and next

All provisions of Indian Boiler Regulations, 1950.

Questions people ask

Is regulation 228 of Indian Boiler Regulations, 1950. still in force?

No repeal of Indian Boiler Regulations, 1950. is recorded.