Regulation 229, Indian Boiler Regulations, 1950.: Girder stayB lor firebox crowns
Indian Boiler Regulations, 1950. - Regulation 229
Text of regulation 229
Girder stayB lor firebox crowns
229. Girder stayB lor firebox crowns.—(a) For girders supporting crown plates
of rectangular fireboxes, where the ends of the girders are supported by the vertical
end or aideplates, their proportions shall he calculated from the following formula:—
C S T d 1
W.P. = — _ _ • Eqn. (65>
Where WP = Woiking pressure in lb. per sq. inch,
S = Minimum tensile stress of tho material in tons per sq. inch,
T = Total thickness of the stay in thirty seconds of an inch,
d = Depth of the girder si ay in inehei,
L = Length of girder stay in inches measured between the inside
of the tube plate and the firehole plate, or between the inside
of the Bide plates, according to the method of support.
Y = Pitch of girder stays in inches,
C = 22 for steel plates or steel forgings 19 for steel castings.
(b) Where girders are supported in any other way 1han by tho end or wide plates
of the firebox or combustion chamber the calculations for (letcunining the working
pressure shall be made in accordance with the actual conditions of support.
In such cases the length of the strip of firebox or combustion chamber top
plate to be supported by the girder shall, Hubjcot to the limit imposed on tho distanco
of the nearest stay, bo taken as equal to the product of tho number of bolts carried
by the girder into the pitch of the bolts. A maximum nominal stress of 14,000 lbs.
per square inch on girder section shall be allowed for steel.
(c) Slings, links, pins, rivets, and connections to shell of slung girders shall be
sufficient to carry the whole load that would oLhorwise be carried by the girder, and
each girder must be equally slung or supported. For wiresses allowed on tho sections,,
see Regulation 203.
(d) In the oase of girders supported at tho onds only by angle bars riveted to
the casing crown, the length L may, when the girder extends over the full broadth'
of the angle face, be taken as the distance between the centres of the angle faces.
When this distanco does not oxceed that of L in the formula, the pressure shall be
determined in the ordinary way. The supporting angles and rivets shall be of suffi-
cient seoiion for the intended purpose. For stresses allowed on the sections, see
Regulation 203.