Regulation 221, Indian Boiler Regulations, 1950.: Corrugated Furnaces oi. Horizontal Boilers
Indian Boiler Regulations, 1950. - Regulation 221
Text of regulation 221
Corrugated Furnaces oi. Horizontal Boilers
221. Corrugated Furnaces oi. Horizontal Boilers.—Tho maximum working
pressure to be allowed on corrugated furnaces shall be determined by the following
formula—
0
W.P. = — (t—1) Eqn. (59)
D
D is the least external diameter in inches measured at the bottom of the
corrugations on the water side,
t is the thiokness of the furnaoe plate in 32nds of an inch measured at the bottom
of the corrugation or chamber,
C = 480 for the Fox, Morrison, Deighton, Purves, and other similar furnaces
and 510 for the Leeds Forge Bulb Suspension Furnace.