Text of regulation 207

Gusset stays

207. Gusset stays.—The maabnimi working prcpmmi for gusset stays shall be calculated by the following formula :— • 9000 XC W.P. = — • . . . . Eqn. (42) A 0, the oo-effioient, is the number representing the least of the following ;- (1) NiXAi. (2) N J X A J X 1-875. (3) N ,xA,x l -876 . (4) N4XA«. (5) (G—N,D,)/.(t-2) -087. (6) (G!-D 3 )X( t -2 ) \ -037 . NXl JS*B? N3, N4, DX Da, Da, D4. and AL, Ai; A3, A ,̂ are respectively the numbers, diameters and sectional areas of the rivets in the joints of eaoh gusset stay, only- rivets in the supported area, to be < oimideml effective the order of the joints being (1), angles to end plate, (2) end plate unules to tjusset, (3) shell angles to gusset, ana (4) angles to shell, G is the depth in inches of gusset plate measured through the line of rivets attaching it to the end plate angles, Gx is the depth in inohes of gusset plate measured normal to the slant edge of plate through the rivet nearest to the end plate in the joint attaohing gusset plate to shell angles, t ia the thickness of the gusset plate in 32ndw of an inoh, A is the area in square inches of flat plate supported by the gusset stay which, in the case of Lancashire and Cornish boilers, shall be determined as follows : (a) The margins allowed under fiat plate regulations for shell and furnace shall be marked on end plates and the lengths of the centre lines of gussets between them measured, also the distance between eaoh pair of gusset lines from the middle of the smaller in a direction normal to the greater. TfLand l-^be the lengths of two adjaoen* Bso. 81 THB GAZETTE OF INDIA EXTBAOBtHflAjU 8#* gusset lines and if the distant* between them be W, th* area oontained by the gusset fines and the shell and furnace margin lines may be apportioned between the stays thus:— — . .. *• Portion of area in tqnare inches, 8 apportioned to L line gusset Eqn. (43) WOI^+L) = Portion of area in square inohea 8 apportioned to LT line gusset . . . . . Eqn. (44) (b) The portion of the area on the other side of eaoh gusset line shall, except when of triangular form, be found in like manner and its amount added to that al- reedv found to form the total. """ fb) For the triangular portions in the wing spaces the area shall be taken an half the produot of the length of gusset line into the perpendicular distance between it and the intersecting point where the marginal ourves meet. BOLTS AND STUDS 308. (a) Bolts and studs connecting parts of boilers such as shell, end plates, tube plates, furnaces, uptakes, externally fitted manhole covers, mountings, eto., may be made either of steel or good quality wrought iron. (b) The maximum working pressure for the bolts or studs Bhall be oaloulated by the following formula :— N X G / 1-28\E W.P. = 1 D — 1 Eqn. (45) A \ n / D is the diameter of bolt or stud over threads in incb.es, N ia the number of bolts or studs securing the part, n is the number of threads of sorew per inch, 0=4,700 for steel bolts or studs of 28 tons/sq. in. minimum ultimate tensile stress where the diameter over thread is less than 3/4 inch. C—5,100 for steel bolts or studs of 30 tons/sq. in. minimum ultimate tensile stress where the diameter over thread is less the 3/4 inoh. 0=5,600 for steel bolts or studs of 35 tons/sq. in. minimum ultimate tensile stress where the diameter over thread is less than 3/4 inoh. C=5,600 for steel bolts or stud a of 28 tons/sq. in. minimum ultimate tensile stress where thf diameter over thread ic not less than 3/4 inoh and not greater than 7/8 inch, C--7,000 for steel bolts for studs of 28 tons/sq. in. minimum ultimate tensile stress -«here the diameter over thread is greater than 7/8 inch. When the material is iron, a reduction of 15 per oent Bhall be made in the work- ing pressure as calculated by the formula. A the area in square inohes of the surface supported by the bolts or studs. For jointed flanges the area shall be taken to extend to midway between the pitoh line of tho bolts and the inner edge of the flange by whioh the part is secured, _/u L Ji UAzijLlli UJ JIMD1A JKjAlKAOKDlNAKi [PART I I TUBE PLATES

Previous and next

All provisions of Indian Boiler Regulations, 1950.

Questions people ask

Is regulation 207 of Indian Boiler Regulations, 1950. still in force?

No repeal of Indian Boiler Regulations, 1950. is recorded.