Regulation 206, Indian Boiler Regulations, 1950.: Measurements of stayed areas in the end plates of locotype and vertical boilers
Indian Boiler Regulations, 1950. - Regulation 206
Text of regulation 206
Measurements of stayed areas in the end plates of locotype and vertical boilers
206. Measurements of stayed areas in the end plates of locotype and vertical
boilers.—When the areah supported b\ ->tays aro semi-circular as in the upper
parts of the end plates and amokebox tube plates of loootype boilers, or annular
as in the crown plates of vertical type boilers, the area to be supported by stays, A in
Eqns. 39 and 40 shall, in the first case, bo the area of the plate contained within
iihe margins orodited to oasing or barrel sides, screw stays, fire door ring or tube stays
as the case may be, and in the seoond case be the area of the annulus between the
margins credited to uptake and ah ell, When bolt staying is neoessary, the stays shall
be properly distributed ; the aggregate stay seotion shall then be used, in the formula
for calculating the working pressure.