Regulation 199, Indian Boiler Regulations, 1950.: Bar or bulb stiffened end plates and smokebox tube plates of locotype boilers

Indian Boiler Regulations, 1950. - Regulation 199

Text of regulation 199

Bar or bulb stiffened end plates and smokebox tube plates of locotype boilers

199. Bar or bulb stiffened end plates and smokebox tube plates of locotype boilers.—Where suoh plates instead of being supported by stays aie stiffened in the steam space by substantial tec oi angle bar s securely riveted to the plate and ex- tending across the plate to within tbe margin allowed by Equation (37) or where suoh plates are formed with a deep bulb extending across the plate to well within the margin allowed, for the support thus given, 0 shall be taken as equal to 80 and 70 for plates not exposed, and exposed, to- flame respectively. The margin or pitch for suoh stiffening shall be measured from the centre line of rivets or commencement of ouivahiro of bulb provided it is not more than 2 inches from the oentre line of bulb. For the flat plate above the stiffenej or bulb, 0 shall be token as the mean of the values appropriate for the points of support.

Previous and next

All provisions of Indian Boiler Regulations, 1950.

Questions people ask

Is regulation 199 of Indian Boiler Regulations, 1950. still in force?

No repeal of Indian Boiler Regulations, 1950. is recorded.