Regulation 194, Indian Boiler Regulations, 1950.: Flat plates supported by stays and nuts and large washers or strips or doublings
Indian Boiler Regulations, 1950. - Regulation 194
Text of regulation 194
Flat plates supported by stays and nuts and large washers or strips or doublings
194. Flat plates supported by stays and nuts and large washers or strips or
doublings.—(a) Whero the plates ari- supported by stays passing through tlvm and
are fitted with nuts inside and washers and nuts outside, tho diameter of the wa-
shers being at least 31 times that of the stay, and their thickness at least two-thirds
that of tho plate, nut not greater than that of the plate, the maximum working
pressure shall be ;—
100
W.P. =, [(t-l)»+'15V] Eqn. (29)
A'+B»
(6) where the washers have a diameter of at least two-thirds of the pitch of
the stays and a thickness of at least two-thirds of the thickness of the plate, but not
. . i i . U J 1JNU1A jiJAi±tA.OJtlJJUNA. ... [J.J ttiX
greater than that of the plate, and are riveted to the piale in an ffloient manner,
the maximum working pressure shall be :—
100
W. P. =-• [(t-l)«+-36V] Eqn. (30)
A»+B"
(o) Where the plate is stiffened by strips at least two-thirds of the pitch of the
Htftye in breadth whioh have a thickness of at least two-thirds of that of the plate
but not greater than that of the plate, and are riveted to the plate in an effloient
manner, the maximum •working pressure shall be:—
100
W. P . - ~ — - [ ( t - l ) « + - 5 5 V ] Eqn. (31)
A«+B»
(d) Where the plates are fitted with doubling plates having a thiokness of at
least two-thirds of that of the plate but not greater than that of the plate, and are
riveted to them in an effloient manner, the maximum working pressure shall be :•—
100
W. P. =. t(t-l)»+-85t1"] Eqn. (32) •,
A'+B*