LawGrids logoLAWGRIDS.ORG

Regulation 192, Indian Boiler Regulations, 1950.: Dished shell and firebox crowns

Indian Boiler Regulations, 1950. - Regulation 192

Text of regulation 192

Dished shell and firebox crowns

192. Dished shell and firebox crowns.—(w) In determining the working pressure in accordance with Regulations 189 and 190 no account shall be taken of the In- fluence of the uptake tube in vertical boilers. If dished crown plates having up- takes are fit for higher pressures, when considered as flat plates, under Reg, 19T •uch higher pressure shall be allowed. (b) The radius R of the dished part may be found as follows :— Ca+H« R - Eqn. (27) 2H C and H are the lengths in inches of half the base line or chord on whioh H I* measured and the height of the dish or camber at the middle of the chord ro»* peotively. FLAT PLATES

Previous and next

All provisions of Indian Boiler Regulations, 1950.

Questions people ask

Is regulation 192 of Indian Boiler Regulations, 1950. still in force?