Text of regulation 191

Dished ends oi Lancashire and Cornish type Boilers

191. Dished ends oi Lancashire and Cornish type Boilers.—(a) For dished ends of Lancashire and Cornish boilers with external or internal flanges for furnace* formed in one piece, without stays and subject to internal pressure the maximum working pressure shall be determined by the following formula :— (t~8)x30xS W.P. = Eqn. (26) R W.P. in the working pressure in lbs. per square inoh, t is the thickness of the end plate in 32nds of an inoh, R is the inner radius of curvature of the end in inches which shall not exceed one and a half times the internal diameter of the shell to whioh it is attaohed, 8 is the minimum tensile breaking strength of the plate in tons per square inch Or whatever is allowed for it. (b) The inside radius of curvature at the flange shall be not less than 4 times th» thickness of the plate and in no case less than 3J inohes.