Form II, Central Electricity Authority (Measures relating to Safety and Electric Supply) Regulations, 2023.: FORM II
Central Electricity Authority (Measures relating to Safety and Electric Supply) Regulations, 2023. - Form II
Text of form II
FORM II
FORM II
[See Regulation (32) and (45)]
(Installations of voltage level more than 250 V up to and including 650 V)
Report / Application No. __________
Date of inspection by Electrical Inspector or self-certification by supplier/owner/consumer
______________________________
Date of last inspection or self-certification ___________________
1. Consumer No. ______________________
2. Voltage and system of supply:
(ii) Volts _____________(ii) No. of Phases _____________ (iii) AC/DC _______________
3. Name of the consumer or owner _____________________________
4. Address of the consumer or owner _____________________________
5. Location of the premises _____________________________
6. Particulars of the installations:
(a) Motors:
Make S. No. kW/MW rating Voltage rating Type
(i) ________________________________________________________________
(ii) ________________________________________________________________
(b) Other equipment (complete details to be furnished):
(i) ________________________________________________________________
(ii) ________________________________________________________________
(c) Total connected load kW / kVA _________________________________________
(d) Generators: (complete detail to be enclosed)
Make S. No. kVA rating Voltage rating Type
(iii) ________________________________________________________________
(iv) ________________________________________________________________
7. General condition of the installation:
Sl.No. Regulation No. Requirements Report
1. Regulation 3 Is the record of the designated persons properly made and kept
up to date and duly attested?
Yes/No
2. Regulation 14 (i) Is/Are there any visible sign(s) of overloading in respect
of any apparatus wiring?
Yes/No
(ii) Whether any unauthorised temporary installation exist? Yes/No
(iii) Are the electric supply lines and apparatus so installed,
protected, worked and maintained as to prevent danger?
Yes/No
(iv) Any other general remarks.
3. Regulation 15 Give report on condition of service lines, cables, wires,
apparatus and such other fittings placed by the supplier or
owner of the premises. If not satisfactory, give details.
Satisfactory/
Not Satisfactory
4. Regulation 16 Whether suitable cut-outs/CBs provided by the supplier at the
consumer‟s premises are within enclosed fire proof
receptacle?
Yes/No
5. Regulation 17 (i) Whether switches are provided on live conductors? Yes/No
(ii) Whether indication of a permanent nature is provided as
per regulation so as to distinguish earthed or earthed
neutral conductor from the live conductor as per IS color
Yes/No
154 THE GAZETTE OF INDIA : EXTRAORDINARY [PART III—SEC.4]
code?
(iii) Whether a direct line is provided on the neutral in the case
of single-phase double pole iron clad
switches/Isolators/CBs instead of fuse?
Yes/No
6. Regulation 18 (i) Whether earthed terminal is provided by the supplier? Yes/No
(ii) General visible condition of the earthing arrangement. Satisfactory/
Not Satisfactory
7. Regulation 19 (i) Are bare conductors in building inaccessible? Yes/No
(ii) Whether readily accessible switches have been provided
for rendering them dead?
Yes/No
8. Regulation 20 12. Whether “Danger Notice” in Hindi and the local language of
the district and of a design as per the relevant standards is
affixed permanently in conspicuous position?
Yes/No
9. Regulation 21 (i) Whether insulating floor or mats have been provided? Yes/No
(ii) Whether identification of panel has been provided on the
front and the rear of the panel?
Yes/No
10. Regulation 23 Whether flexible cables used for portable or transportable
equipment covered under the regulation, are heavily insulated
and adequately protected from mechanical injury?
Yes/No
11. Regulation 24 State the condition of metallic coverings provided for various
conductors.
Satisfactory/
Not Satisfactory
12. Regulation 26 Whether the circuits or apparatus intended for operating at
different voltage(s) are distinguishable by means of
indication(s) of permanent nature?
Yes/No
13. Regulation 28 Whether all circuits and apparatus are so arranged that there is
no danger of any part(s) becoming accidentally charged to any
voltage beyond the limits of voltage for which it/they is/are
intended?
Yes/No
14. Regulation 29 (i) In the case of generating stations, whether fire-buckets
filled with clean dry sand have been conspicuously
marked and kept in convenient location in addition to fire-
extinguishers suitable for dealing with fires ?
Yes/No
(ii) Whether First Aid Boxes or cupboards conspicuously
marked and properly equipped are provided and
maintained?
Yes/No
(iii) Is adequate staff trained in First Aid Treatment and
firefighting?
Yes/No
15. Regulation 30 (i) Whether instructions in English or Hindi and the local
language of the district and where Hindi is the local
language, in English and Hindi, for the resuscitation of
persons suffering from electric shock have been affixed in
a “conspicuous place”?
Yes/No
(ii) Are the persons specified under this Regulation able to
apply instructions for resuscitation of persons suffering
from electric shock?
Yes/No
16. Regulation 36 State insulation resistance between conductors and earth in
Mega Ohms.
----- Mega Ohms
17. Regulation 37 (i) Whether a suitable linked switch, or circuit breaker is
placed near the point of commencement of supply so as to
be readily accessible and capable of being easily operated
Yes/No
[भाग III—खण्ड 4] भारतकाराजपत्र:असाधारण 155
to completely isolate the supply?
(ii) Whether every distinct circuit is protected against excess
electricity by means of a suitable circuit breaker or cut-out
?
Yes/No
(iii) Whether suitable linked switch or circuit breaker is
provided near each motor or apparatus for controlling
supply to the motor or apparatus?
Yes/No
(iv) Whether adequate precautions are taken to ensure that no
live parts are so exposed as to cause danger?
Yes/No
18. Regulation 39 (i) Whether clear space of 100 cm is provided in front of
the main switchboard?
Yes/No
(ii) Whether the space behind the switchboard exceeds 75
cm in width or is less than 20 cm?
Yes/No
(iii) In case the clear space behind the switchboard exceeds
75 cm, state whether a passage way from either end of the
switchboard to a height of 1.80 metre is provided.
Yes/No
19. Regulation 43 (i) Have the frame of every generator, stationary motor and
so far as practicable, portable motor and the metallic
parts (not intended as conductors) of all transformers and
any other apparatus used for regulating or controlling
electricity and all apparatus consuming electricity at
voltage exceeding 250 V but not exceeding 650 V been
earthed by two separate and distinct connections with
earth?
Yes/No
(ii) Have the metal casings or metallic coverings containing
or protecting any electric supply line or apparatus been
properly earthed and so joined and connected across all
junction boxes as to make good mechanical and
electrical connection?
Yes/No
(iii) Whether the consumer‟s earth-electrode is properly
executed and has been tested. If yes, give value of earth
resistance?
Yes/No
_____Ohm
(iv) Is the earth wire free from any mechanical damage? Yes/No
(v) Whether record of earth resistance value maintained? Yes/No
(vi) Is the protective equipotential bonding tested? Yes/No
(vii) Is the fault loop impedance at origin of installation
tested?
Yes/No
(viii) Is the fault loop impedance of each circuit tested? Yes/No
(ix) Is the fault loop impedance tested for all sources? Yes/No
20. Regulation 44 Whether Residual Current Device of Appropriate capacity as
defined in Regulation have been provided?
Yes/No
21. Regulation 47 Have the protections and interlocks for the generating units
been provided. Details of the protections shall be given.
Yes/No
22. Overhead Lines (i) State if the consumer has any overhead lines. Yes/No
(ii) Does the overhead line near the premises of consumer
meets the requirement of regulations 60, 61 and 62? If
not, give details.
Yes/No
(iii) Is guarding provided for overhead lines as per regulation
76?
Yes/No
(iv) Any other remarks. Yes/No
156 THE GAZETTE OF INDIA : EXTRAORDINARY [PART III—SEC.4]
Date:
Signature of the supplier/ Owner / Consumer
Name ______________________
Designation _________________
File No. ____________________
To: Office of Electrical Inspector for ………………...