Rule 17, The Punjab Urban Planning and Development Building Rules, 2021: Boundary wall Maximum height allowed

The Punjab Urban Planning and Development Building Rules, 2021 - Rule 17

Text of rule 17

Boundary wall Maximum height allowed

17. Boundary wall Maximum height allowed: - • Front: upto 0.9m with 0.9m high perforated Grill/Jali. • Side & Rear: upto 1.83m. Minimum Turning Radius for corner plot: - 5’-0”. 18. Basement Single story basement is allowed if plot area is 800 sq.m or more, upto zoned area subject to the condition that the owner shall leave minimum 2.44 m (8'-0") setback from the boundary wall of the plot: Provided that the above condition of 2.44 m (8'-0") setback from the adjoining plot shall not be mandatory if adjoining plot does not have a building upto 2.44m from the plot line. The area of the basement should not be more than the ground coverage. Minimum clear height for basement shall be as below: • Non-Habitable use: 2.40 m • Habitable Use: 2.75 m 19. Ramp Not required 20. Stilt, if • Clear Height shall be 7’-6”. provided • Parking provided under stilts shall not be counted towards (Non-habitable Floor Area Ratio but shall be counted toward height of building. height) Serial Parameter Permissible Limits as per Plot Size (sq.m) Number Up to 120 Above Above Above Above 120 to 250 to 350 to 450 250 350 450 PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2305 21. Minimum 1.5 upto D/U above 3 3 Parking required Equivalent size 120 D/U size Equivalent Equivalent as per dwelling Car Spaces sq.m: 1.5 120 upto Car Spaces Car unit size per Equivalent 300 sq.m: per Spaces Dwelling Car Spaces 2 Dwelling per Unit per Equivalent Unit Dwelling Dwelling Car Unit Unit Spaces above D/U per D/U size 120 above upto 300 D/U size sq.m: 2 300 Equivalent 3 Car Spaces Equivalent per D/U Car Spaces per Dwelling Unit 22. Allowable 0.91m or 1/3 1.83 m wide Projection corresponding depth of front or rear setback whichever is less 23. Allowable 1.22 m or 1/3 Balcony corresponding depth of 1.83 m wide front or rear setback whichever is less 24. Rain Water Not required Required Harvesting System 25. Solar Water Residential buildings are also recommended to meet its hot water Heating demand from solar water heaters, as far as possible System Serial Parameter Permissible Limits as per Plot Size (sq.m) Number Up to 120 Above Above Above Above 120 to 250 to 350 to 450 250 350 450 PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2306 26. Solar Photo Plot size Minimum Voltaic requirement 400 yd² (334 m²) to 499 yd² (417 m²): 1 KWp SPV 500 yd² (418 m²) to 999 yd² (835 m²): 2 KWp SPV 1000 yd² (836 m²) to 1999 yd² (1671 m²) : 3 KWp SPV 2000 yd² (1672 m²) and above: 5 KWp SPV 27. Flushing System Provision of dual button type flushing cistern in each water closet. 28. Parapet or Minimum Height: 1.0 m Railing Maximum Height: 1.4 m from the finished floor level 29. Minimum 1050 mm for single loaded and 1500 mm for double loaded. passage or This width shall increase with increase in the occupant load of corridor the building and shall provide as per the National Building Code of India, 2016. 30. Amalgamation Amalgamation allowed or Fragmentation not allowed Fragmentation NOTES:- a) Basement, if constructed, may be used for parking, household storage, habitable and consultancy service purposes. Basement shall be counted towards Floor Area Ratio if used for habitable purposes. b) Front boundary wall shall be optional for providing easy access for parking in front setback within plot area for which approval from the concerned Competent Authority shall be obtained. c) No opening is allowed on party wall of properties. d) The maximum permissible ground coverage and Floor Area Ratio is subjected to the fulfillment of the setback, height and parking norms. e) *Maximum height is excluding mumty, parapet, and architectural features. f) The stilts shall be compulsory and shall be counted towards height of the building. g) In case of Independent floors, plots shall be in a block of row housing and earmarked for independent floors in the Layout Plan or Zoning Plan. Serial Parameter Permissible Limits as per Plot Size (sq.m) Number Up to 120 Above Above Above Above 120 to 250 to 350 to 450 250 350 450 PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2307 h) No individual plot in any block which is not earmarked in the Layout Plan or Zoning Plan for independent floors shall be allowed to be constructed as an independent floor unless the building is detached having minimum plot area 800 square meters. i) The parking required in case of independent floors shall compulsorily be under stilts. However, in case of an independent plot having minimum area of 800 square meters used for independent floors, the parking under stilts shall be optional, provided that the promoter provides surface/ basement parking as per norms within the plot. j) Clear height of Stilt from the finished level of the ground floor to the under surface of the beam, joint girders or any other horizontal structure member shall be 7’-6”. k) In case of independent floor, common staircase or common elevator is permissible maximum for two plots subject to the condition that the minimum clear width of staircases shall be 1350 mm. l) Parking in independent floors under stilts shall be permissible beyond stilts within the plot area, if the parking under stilts is not sufficient as per norms, and m) For calculation of infrastructure required for the project, the population of independent floors having S+4 or G+3 it shall be @ 20 persons per plot, where basement is used for habitable purpose then the density of five person per basement shall be added to the permissible density of the plot. (3) Group Housing Serial Parameter Permissible Limits Number 1. Minimum Set back 6m minimum from site boundary and as per sub rule (1) around building of rule 26 of these building rules. required 2. Maximum Permissible 30 percent of Site area Ground Coverage 3. Maximum Permissible Minimum approach road 18 m 1:2.0 Floor Area Ratio Minimum approach road 24 m 1:2.5 Minimum approach road 30 m 1:3.0 Minimum approach road 45 m & above Unlimited* 4. Maximum Permissible No Restriction subject to the fulfilment of norms such Height as setbacks around building, ground coverage, Floor Area Ratio, structural safety and fire safety norms. PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2308 However, clearance from Airport Authority of India or Indian Air Force is required in case the height of the building is 15m or more or site falls in the red colour of home grid of Colour Coded Zoning Map issued by Airports Authority of India or Indian Air Force. 5. Plinth Level 450mm or as specified by competent authority (from the crown of adjoining road in front). Provided that for a detached building, the plinth level may be more than 450mm: Provided further that the level of front courtyard of any building shall not exceed 450 mm and the ramp from the front road to the courtyard shall be within the plot boundary. 6. Minimum requirements Component of Min. area Min. Min. of different component Building (SQ.M) Width Clear of a building (M) Height (M) Habitable room 9.5 2.4 2.75 Kitchen • where separate 5 1.8 dining area is provided • where separate 4.5 1.8 2.75 store is provided • where dinning 7.5 2.1 included Bathroom 1.8 1.2 2.1 Water Closet (W.C.) 1.2 0.9 2.1 combined bath and w.c 2.8 1.2 2.1 Store 3 1.2 2.2 Single occupancy 7.5 2.1 2.75 Servant Room Serial Parameter Permissible Limits Number PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2309 7. Light and Ventilation (a) one or more openings, such as windows and ventilators, opening directly to the external air or into an open Verandah. (b) such openings, excluding doors inclusive of frames, shall not be less than one-tenth of the floor area. In case of Kitchen such opening shall be increased by 25 percent. 8. Ventilation Shaft the size of ventilation shaft shall not be less than the values given below: Height of building Size (sq.m) Min. one dimension 10m 1.2 0.9 m 12m 2.8 1.2 m 18m 4.0 1.5 m 24m 5.4 1.8 m 30m 8.0 2.4 m Above 30m 9.0 3.0 m Notes: (a) For buildings of height above 30 m, a mechanical ventilation system shall be installed besides the provision of minimum ventilation shaft. (b) For fully air conditioned the ventilation shaft need not be insisted upon, provided the air conditioning system works in an uninterrupted manner, also, provided there is an alternative source of power supply. (c) Mechanical ventilation in building shall be as per the provision of the National Building Code of India, 2016, as amended from time to time. 9. Interior Courtyard Minimum area: 9 sq.m for Light and Minimum width: 2.4m or 1/5 of the average height of Ventilation the building, whichever is more. 10. Staircase Minimum Width: 1350 mm requirement: Minimum Tread: 300 mm Maximum Riser: 150 mm Minimum Clear Head Height: 2200 mm Serial Parameter Permissible Limits Number PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2310 11. Lift and Ramp Lift is mandatory in buildings 15m or more in height requirement and basement provided more than one level as per the provision of the National Building Code of India, 2016. Ramp requirement for pedestrians, differently-abled, elderly and children upto Plinth Level :- Min. Width - 1800mm Min. Slope - 1:12 12. Mumty Allowed upto 2.75 m, otherwise counted towards the height of the building as well as Floor Area Ratio. 13. Services in terrace Solar Photo Voltaic installation, Rain water pipes with drainage, Water Tank, cooling towers for air conditioning plants, mumty, machine room and screening parapet to hide services or as per the provisions of the National Building Code of India, 2016. 14. Gate and post check Watch and ward cabins upto 100 sq.ft along each entry gate exempted from Ground Coverage and Floor Area Ratio (FAR). 15. Boundary wall Maximum height allowed: - Facing road or open area: upto 0.9m solid wall with 0.9m high perforated Grill/Jali. Facing other property: upto 1.83m solid wall Minimum Turning Radius for corner plot: - 5’-0” or 1/8th of the adjoining road width, whichever is more and maximum upto 20’-0”. 16. Basement The multi-level basement in plots of an area above 2025 sq.m shall be allowed below the ground and beyond the building line at ground level subject to a clear minimum front margin of 4.5 m and side and rear margins of 3 m, subject to the provision of mechanical ventilation and all safety provisions and drainage. Basement shall not be allowed in the case of No construction Zone/Area or Master Plan Green area or any other restricted area/zone under the provision of any other Act/policy of the State or Central Government. Serial Parameter Permissible Limits Number PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2311 Minimum clear height for basement shall be as below: • Non-Habitable use: 2.40 m • Habitable Use: 2.75 m 17. Stilt, if provided • Clear Height shall be 7’-6”. (Non-habitable height) • Parking provided under stilts shall not be counted towards Floor Area Ratio and height. 18. Vehicular Ramp Ramps are mandatory. Minimum width: 7.2m for two way traffic 4m for one way traffic Slope: (i) Cars not less than 1:8 and at curve 1:12 (ii) Heavy vehicles not less than 1:15 19. Minimum Parking Size of Dwelling Unit Equivalent Car Space (ECS) required as per size Required of Dwelling Unit size upto 90 sq.m: 1 ECS per Dwelling Unit above 90 upto 120 sq.m: 1.5 ECS per Dwelling Unit above 120 upto 300 sq.m: 2 ECS per Dwelling Unit above 300 sq.m: 3 ECS per Dwelling Unit Additional 10 percent guest parking shall also be provided 20. Projection (Free from 1.83 m wide Ground Coverage and Floor Area Ratio) 21. Balcony 1.83 m wide (Free from Ground Coverage and Floor Area Ratio) 22. Rain Water Mandatory requirement Harvesting System 23. Solar Water Residential buildings are also recommended to meet its Heating System hot water demand from solar water heaters, as far as possible. 24. Solar Photo Voltaic Plot size Requirement required as per plot size (a) 0.5 acre to 1 acre Minimum 10 Kilo Watt (KWp) (b) Above 1 acre to 2 acres Minimum 20 Kilo Watt (KWp) (c) Above 2 acre to 5 acres Minimum 30 Kilo Watt (KWp) (d) Above 5 acre Minimum 40 Kilo Watt (KWp) Serial Parameter Permissible Limits Number PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2312 25. Flushing System Provision of dual button type flushing cistern in each water closet. 26. Parapet or Railing Minimum Height: 1.0 m Maximum Height: 1.4 m from the finished floor level 27. Minimum passage 1350 mm for single loaded and 1800 mm for double or corridor loaded. This width shall increase with increase in the occupant load of the building and shall provide as per the National Building Code Of India, 2016. 28. Economically Weaker As per the government policy dated 24.05.2016 or as Section (EWS) amended from time to time. 29. Green Area Minimum 25 percent of site area in which 15 percent of requirement site area shall be in the form of organized park or playground with minimum width of 15m. 30. Convenient Shopping Maximum upto 1 percent of the total Floor Area Ratio area shall be allowable for convenient shopping such as grocery shop, vegetable shop, laundry and dry cleaning, medical store, confectionery, bakery, hair cutting saloon, stationery shop, milk booth excluding Club Building. 31. Amalgamation or Amalgamation not allowed Fragmentation Fragmentation not allowed Notes:- a) The Floor Area Ratio above 1:2 in case of Group Housing will be chargeable on pro-rata basis. However, the site allotted or sold by the development authority the charges shall be applicable as per the terms and conditions of the allotment letter. b) *Unlimited Floor Area Ratio shall be subject to fulfillment of building controls such as ground coverage, setbacks around the building, parking norms, light and ventilation, height, fire and structural safety. c) Access to commercial building in group housing may be allowed from external road subject to the fulfillment of parking, setback and road width etc. d) The Net Residential Density shall be permissible as per the provisions of the respective Master Plans, government notifications as amended from time to time whichever is applicable. e) For calculation of infrastructure required for the project, the population for group housing shall be @ 4.5 persons per Dwelling Unit. Serial Parameter Permissible Limits Number PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2313 (4) Studio Apartment Serial Parameter Permissible Limits Number 1. Minimum Site Area 2000 sq.m 2. Maximum size of Unit 50 sq.m 3. Minimum Set back 6m minimum from site boundary and as per sub rule around building required (1) of rule 26 of these building rules. 4. Maximum Permissible 30 percent of Site area Ground Coverage 5. Maximum Permissible Minimum approach road 18 m 1:2.0 Floor Area Ratio Minimum approach road 24 m 1:2.5 Minimum approach road 30 m 1:3.0 Minimum approach road 45 m & above Unlimited* 6. Maximum No Restriction subject to the fulfilment of norms such Permissible Height as setbacks around building, ground coverage, Floor Area Ratio, structural safety and fire safety norms. However, clearance from Airport Authority of India or Indian Air Force is required in case the height of the building is 15m or more or site falls in the red colour of home grid of Colour Coded Zoning Map issued by Airports Authority of India or Indian Air Force. 7. Plinth Level 450mm or as specified by competent authority (from the crown of adjoining road in front). Provided that for a detached building, the plinth level may be more than 450mm: Provided further that the level of front courtyard of any building shall not exceed 450 mm and the ramp from the front road to the courtyard shall be within the plot boundary. 8. Minimum Component of Building Min. Min. Min. requirements of area Width Clear different component (SQ.M) (M) Height of a building (M) Habitable room 9.5 2.4 2.75 Kitchen • where separate dining 5 1.8 area is provided PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2314 • where separate store 4.5 1.8 2.75 is provided • where dinning included 7.5 2.1 Bathroom 1.8 1.2 2.1 Water Closet ( W.C.) 1.2 0.9 2.1 combined bath and w.c 2.8 1.2 2.1 Store 3 1.2 2.2 Garage 18 3 2.4 Single occupancy 7.5 2.1 2.75 Servant Room 9. Light and Ventilation (a) one or more openings, such as windows and ventilators, opening directly to the external air or into an open Verandah (b) such openings, excluding doors, shall not be less than one-tenth of the floor area. In case of Kitchen such opening shall be increased by 25 percent. 10. Ventilation Shaft the size of ventilation shaft shall not be less than the values given below:- Height of building Size (sq.m) Min. one dimension 10m 1.2 0.9 m 12m 2.8 1.2 m 18m 4.0 1.5 m 24m 5.4 1.8 m 30m 8.0 2.4 m Above 30m 9.0 3.0 m Notes: (a) For buildings of height above 30 m, a mechanical ventilation system shall be installed besides the provision of minimum ventilation shaft. (b) For fully air conditioned the ventilation shaft need not be insisted upon, provided the air conditioning system works in an uninterrupted manner, also, provided there is an alternative source of power supply. Serial Parameter Permissible Limits Number PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2315 (c) Mechanical ventilation in building shall be as per the provision of the National Building Code of India, 2016, as amended from time to time. 11. Interior Courtyard Minimum area: 9 sq.m Minimum width: 2.4m or 1/5 of the average height of the building, whichever is more. 12. Staircase requirement: Minimum Width: 1350 mm Minimum Tread: 300 mm Maximum Riser: 150 mm Minimum Clear Head Height: 2200 mm 13. Lift and Ramp Lift is mandatory in buildings 15m or more in height requirement and basement provided more than one level as per the provision of the National Building Code of India, 2016. Ramp requirement for pedestrians, differently-abled, elderly and children upto Plinth Level :- Min. Width - 1800mm Min. Slope - 1:12 14. Mumty Allowed upto 2.75 m, otherwise counted towards the height of the building as well as Floor Area Ratio. 15. Services in terrace Solar Photo Voltaic installation, Rain water pipes with drainage, Water Tank, cooling towers for air conditioning plants, mumty, machine room and screening parapet to hide services or as per the provisions of the National Building Code Of India, 2016. 16. Gate and post check Watch and ward cabins upto 100 sq.ft along each entry gate exempted from Ground Coverage and Floor Area Ratio (FAR). 17. Boundary wall Maximum height allowed: - Facing road or open area: upto 0.9m solid wall with 0.9m high perforated Grill/Jali. Facing other property: upto 1.83m solid wall. Minimum Turning Radius for corner plot: - 5’-0” or 1/8th of the adjoining road width, whichever is more and maximum upto 20’-0”. Serial Parameter Permissible Limits Number PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2316 18. Basement Plot size upto 2025 sq.m: single story basement is allowed upto zoned area or upto the boundary of the plot except front and rear side, as the case may be, subject to the condition that the owner shall leave minimum 2.44 m (8'-0") setback from the respective side of the boundary wall of the plot, if adjoining plot has a building upto 2.44m from the plot line. Plot size above 2025 sq.m: The multi-level basement shall be allowed below the ground and beyond the building line at ground level subject to a clear minimum front margin of 4.5 m and side and rear margins of 3 m, subject to the provision of mechanical ventilation and all safety provisions and drainage. Basement shall not be allowed in the case of No construction Zone/ Area or Master Plan Green area or any other restricted area/zone under the provision of any other Act/policy of the State or Central Government. Minimum clear height for basement shall be as below: • Non-Habitable use: 2.40 m • Habitable Use: 2.75 m 19. Stilt, if provided • Clear Height shall be 7’-6”. (Non-habitable height) • Parking provided under stilts shall not be counted towards Floor Area Ratio and height. 20. Vehicular Ramp Ramps are mandatory. Minimum width: 7.2m for two way traffic 4m for one way traffic Slope: (i) Cars not less than 1:8 and at curve 1:12 (ii) Heavy vehicles not less than 1:15 21. Minimum Parking 2 Equivalent Car Space per 100 sq.m of total Floor Space required Area Ratio area 22. Projection (Free from 1.83 m wide Ground Coverage and Floor Area Ratio) Serial Parameter Permissible Limits Number PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2317 23. Balcony (Free from Ground 1.83 m wide Coverage and Floor Area Ratio) 24. Rain Water Mandatory requirement Harvesting System 25. Solar Water Residential buildings are also recommended to meet its Heating System hot water demand from solar water heaters, as far as possible 26. Solar Photo Voltaic Plot size Requirement required as per plot (a) 0.5 acre to 1 acre Minimum 10 Kilo Watt (KWp) size (b) Above 1 acre to 2 acres Minimum 20 Kilo Watt (KWp) (c) Above 2 acre to 5 acres Minimum 30 Kilo Watt (KWp) (d) Above 5 acre Minimum 40 Kilo Watt (KWp) 27. Flushing System Provision of dual button type flushing cistern in each water closet. 28. Parapet or Railing Minimum Height: 1.0 m Maximum Height: 1.4 m from the finished floor level 29. Minimum passage 1350 mm for single loaded and 1800 mm for double or corridor loaded. This width shall increase with increase in the occupant load of the building and shall provide as per National Building Code of India, 2016. 30. Economically Weaker As per the government policy dated 24.05.2016 or as Section (EWS) amended from time to time. 31. Green Area Minimum 25 percent of site area in which 15 percent of requirement site area shall be in the form of organized park or playground with minimum width of 15m. 32. Amalgamation or Amalgamation allowed Fragmentation Fragmentation not allowed Notes:- a) The population density of Studio Apartments shall be counted as two persons per unit. b) The Floor Area Ratio above 1:2 in case of Studio Apartments will be chargeable on pro-rata basis. However, the site allotted or sold by the development authority the charges shall be applicable as per the terms and conditions of the allotment letter. Serial Parameter Permissible Limits Number PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2318 c) *Unlimited Floor Area Ratio shall be subject to fulfillment of building controls such as ground coverage, setbacks around the building, parking norms, light and ventilation, height, fire and structural safety. d) The Net Residential Density shall be permissible as per the provisions of the respective Master Plans, government notifications as amended from time to time whichever is applicable. (5) Farm House Serial Parameters Permissible Limits Number 1. Permissible or 2.5 Acres Minimum Site Area 2. Minimum setbacks Front: 15m required Side and Rear: 6m 3. Maximum Floor 1:0.05 Area Ratio 4. Maximum Ground 5 percent of Site area Coverage 5. Plinth 450mm or as specified by competent authority (from the crown of adjoining road in front). Provided that for a detached building, the plinth level may be more than 450mm: Provided further that the level of front courtyard of any building shall not exceed 450 mm and the ramp from the front road to the courtyard shall be within the plot boundary. 6. Maximum Height of 9 m Building 7. Maximum numbers of G+1 Floors allowed 8. Minimum requirements Component Min. Min. Min. of different component of Building area Width Clear of a building (SQ.M) (M) Height (M) Habitable room 9.5 2.4 2.75 Kitchen where separate 5 1.8 dining area is provided PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2319 where separate 4.5 1.8 2.75 store is provided where dinning 7.5 2.1 included Bathroom 1.8 1.2 2.1 Water Closet 1.2 0.9 2.1 (W.C.) combined 2.8 1.2 2.1 bath and w.c Store 3 1.2 2.2 Single 7.5 2.1 2.75 occupancy Servant Room 9. Light and Ventilation (a) one or more openings, such as windows and ventilators, opening directly to the external air or into an open Verandah. (b) such openings, excluding doors inclusive of frames, shall not be less than one-tenth of the floor area. In case of Kitchen such opening shall be increased by 25 percent. 10. Ventilation Shaft the size of ventilation shaft shall not be less than the values given below:- Height of building Size Min. one (sq.m) dimension 10m 1.2 0.9 m Notes:- (a) For fully air conditioned, the ventilation shaft need not be insisted upon, provided the air conditioning system works in an uninterrupted manner, also, provided there is an alternative source of power supply. (b) Mechanical ventilation in building shall be as per the provision of the National Building Code of India, 2016, as amended from time to time. Serial Parameter Permissible Limits Number PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2320 11. Interior courtyard for Minimum area 9 sq.m Light and Ventilation Minimum width 2.4 m or 1/5 of the average height of the building whichever is more. 12. Staircase Minimum Clear Width: 1000 mm Minimum Tread: 250 mm Maximum Riser: 190 mm Minimum Headroom Height: 2200 mm 13. Lift Allowed as per the provisions of the National Building Code of India, 2016. 14. Mumty Allowed upto 2.75 m, otherwise counted towards the height of the building as well as Floor Area Ratio. 15. Services on Terrace Solar Photo Voltaic installation, Water tank, Rain water pipes with drainage, Water Tank, mumty, machine room and screening parapet to hide services or as per the provisions of the National Building Code of India, 2016. 16. Gate and post check Watch and ward cabins upto 100 sq.ft along each entry gate exempted from Ground Coverage and Floor Area Ratio (FAR). 17. Boundary wall Maximum height allowed: - Facing road or open area: upto 0.9m solid wall with 0.9m high perforated Grill/Jali. Facing other property: upto 1.83m solid wall Minimum Turning Radius for corner plot: - 5’-0” or 1/8th of the adjoining road whichever is more and maximum upto 20’-0”. 18. Basement Basement shall be permitted to the maximum extent of building footprint. Minimum clear height for basement shall be as below: Non-Habitable use: 2.40 m Habitable Use: 2.75 m Serial Parameter Permissible Limits Number PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2321 19. Vehicular Ramp Ramp is not mandatory. Parking in basement can be permitted through car lift. 20. Parking 1.5 Equivalent Car Space / 100 sq.m of the total Floor Area Ratio area. 21. Projection or Balcony Maximum allowable projection (free from ground coverage and floor area ratio): 1.80m (6’-0”) within zoned area 22. Rainwater Harvesting Compulsory 23. Solar Water Heating Not mandatory but recommended meeting its hot System water demand from solar water heaters, as far as possible. 24. Solar Photo Voltaic 5KWp SPV 25. Flushing System Dual button type flushing cistern in each water closet. 26. Parapet or Railing Minimum Height: 1.0 m Maximum Height: 1.4 m from the finished floor level. 27. Minimum Passage 1050 mm for single loaded and 1500 mm for double or Corridor loaded Notes:- (a) The ground coverage and Floor Area Ratio is inclusive of ancillary buildings such as labour/ servant quarters which shall not be more than 25 percent of the Floor Area Ratio area of the site. (b) The temporary structure or building like Cattle Shed, Motor Room, covered parking etc. shall be exempted from ground coverage and floor area ratio. (c) No sub-division of plot shall be allowed. (B) Other general control for residential buildings.- (i) For calculation of infrastructure required for the project, the population of villa shall be counted @ five persons per villa and plotted development shall be counted @ fifteen persons per plot, whereas in case of independent floors having S+4 or G+3 it shall be @ twenty persons per plot and for group housing it shall be @ five persons per Dwelling Unit. where basement is used for habitable purpose then the density of five persons per basement shall be added to the permissible density of the plot. Serial Parameter Permissible Limits Number PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2322 (ii) Floating population shall be taken as minimum one hundred person per acre for calculation of infrastructural or services requirements only and shall not be counted towards the regular density of the project or sector. (iii) The population density of Studio Apartments shall be counted as two persons per unit. (iv) The Population density of Rental housing shall be counted as one person per 12.5 sq.m of total covered area of the building or as per actual, whichever is more. (v) The density for each category of flats in case of Group Housing or Apartments or Studio Apartments shall be calculated separately. The promoter has to clearly indicate the area under each category of flats. (vi) The clubbing of two or more plots or plots earmarked for independent floors in row housing may be allowed. The promoter or owner has to get a revised Zoning Plan approved from the Competent Authority. (vii) In case of residential plot, it is mandatory to provide indigenous or fruit tree in the premises of plot as per criteria described in Part IX of these rules. (viii) In case of Low Density Country Homes Residential Development Projects, Economical Weaker Section housing, Affordable housing, housing for all, Pardhan Mantri Awas Yojna (PMAY), Punjab Shehri Awas Yojana (PSAY) and any other policy relating to housing issued by State or Central Government, the physical and development norms as prescribed in the said policy as amended from time to time shall be applicable. (ix) Professional activity shall be allowed in residential plot and flats on any floor on the following condition:- Part of the premises shall be permitted to be used upto a maximum of 25 percent of Floor Area Ratio or 100 sq.m, whichever is less, for non- nuisance, non service, non-teaching, non-commercial, or non trading activities for rendering consulting based on professional skills such as charted accountant, architect, planner, advocates, doctors (only consultancy) or other similar activities. PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2323 4 (A) COMMERCIAL.- The commercial buildings of various types shall be governed by the following norms, namely:- (1) Convenient Shopping/ Neighbourhood Shopping Plotted within approved layout plan. Serial Parameter Permissible Limits as per Plot Size (sq.m) Num- Category Booth Shops/ shop Shops/ shop cum ber cum offices offices 1. Set backs Setbacks of booths/Shops/shop cum offices shall be governed by the permissible ground coverage and architectural control sheets/zoning plan. 2. Width Upto 3m Above 3m Above 5m of Plot to 5m 3. Maximum 1:1.0 1:2.0 1:3.0 permissible Floor Area Ratio 4. Maximum 100 percent Depth of plot upto Depth of plot upto Permissible 12m : 100 percent 12m : 100 percent Ground Depth of plot more Depth of plot more Coverage than 12m : 80 than 12m : 75 percent percent 5. Maximum Height of booths/ Shops/ shop cum offices shall be governed by Permissible control sheets/zoning plan. Height 6. Maximum 1 (Ground 2 (G+1) 4 (G+3) numbers of Floor) Storeys allowed 7. Minimum 2.2 m 2.5 m 2.5 m width of corridor/ Canopy/ Projection etc. for weather protection Section 180 (2) PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2324 8. Minimum Component Min. area Min. Min. requirements of Building (SQ.M) Width Clear of different (M) Height (M) component Habitable room 9.5 2.4 2.75 of a building Bathroom 1.8 1.2 2.1 Water Closet 1.2 0.9 2.1 ( W.C.) combined bath 2.8 1.2 2.1 and w.c Store 3 1.2 2.2 9. Light and (a) one or more openings, such as windows and ventilators, Ventilation opening directly to the external air or into an open Verandah. (b) such openings, excluding doors inclusive of frames, shall not be less than one-tenth of the floor area. In case of Kitchen such opening shall be increased by 25 percent. 10. Ventilation the size of ventilation shaft shall not be less than the values shaft given below: Height of building Size Min. one dimension 10m 1.2 sq.m 0.9 m 12m 2.8 1.2 m 18m 4.0 1.5 m 11. Staircase requirement: Minimum Width- For Plot width: upto 7.5m Not required 900 mm 900 mm Above 7.5m - 1500 mm Minimum Tread 300 mm 300mm Maximum Riser 150 mm 150 mm Minimum Clear 2200mm 2200mm Head Height 12. Lift Allowed as per the provisions of the National Building Code Of India, 2016. Serial Parameter Permissible Limits as per Plot Size (sq.m) Num- Category Booth Shops/ shop Shops/ shop cum ber cum offices offices PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2325 13. Ramp Ramp is mandatory for plinth • Minimum width: 1800mm • Slope: Not less than 1:12 14. Mumty Allowed upto 2.75 m, otherwise counted towards the height of the building as well as Floor Area Ratio. 15. Services in Solar Photo Voltaic installation, Water tank, Rain water pipes terrace with drainage, Water Tank, cooling towers for air conditioning plants, mumty, machine room and screening parapet to hide services or as per the provisions of the National Building Code Of India, 2016. 16. Basement Single story basement is allowed upto zoned area subject to the condition that the owner shall leave minimum 2.44 m (8'-0") setback from the boundary wall of the plot: Provided that the above condition of 2.44 m (8'-0") setback from the adjoining plot shall not be mandatory if adjoining plot does not have a building upto 2.44m from the plot line. Minimum clear height for basement shall be as below: • Non-Habitable use: 2.40 m • Habitable Use: 2.75 m 17. Minimum 2 Equivalent Car Spaces per 100 sq.m of total Floor Parking Space Area Ratio area. required In addition to the parking spaces provided, a space at the rate of 3.5m x 7.5m, shall be provided for loading and unloading activities for each 1000 m² of floor area or fraction thereof. 18. Rain Water Not required Required Harvesting System 19. Solar Water Recommended to meet its hot water demand from solar water Heating heaters, as far as possible System 20. Solar Photo Not Mandatory Voltaic 21. Flushing Provision of dual button type flushing cistern in each water closet. System Serial Parameter Permissible Limits as per Plot Size (sq.m) Num- Category Booth Shops/ shop Shops/ shop cum ber cum offices offices PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2326 22. Diesel The location of the Diesel Generator (DG) set and exhaust pipe Generator Set height shall be as per the provisions of the CPCB norms. 23. Parapet or Minimum Height: 1.0 m Railing Maximum Height: 1.4 m from the finished floor level 24. Amalgamation Amalgamation allowed or Fragmentation not allowed Fragmentation Notes:- (a) The plotted convenient shopping or neighbourhood shopping development shall be permissible on 18m (60’-0”) wide road subject to the condition that the maximum area of the site shall not be more than 8000 sq.mt. The minimum approach road for area more than 8000 sq. mt. shall be 24m (80'-0"). (b) The Floor Area Ratio above 1:1.75 in case of commercial building, will be chargeable on pro-rata basis. However, the site allotted or sold by the development authority the charges shall be applicable as per the terms and conditions of the allotment letter. (c) In case of commercial plot having openings on both sides- front and rear, then the ground coverage to be permitted in such cases shall be upto 100 percent of the plot area carved out shops, shop-cum-offices, shop-cum-flat etc. subject to the conditions that corridors of appropriate width, as specified above shall be provided in front of each opening. The basement shall be restricted under the building excluding the area under corridors. Floor Area Ratio, height, number of storeys, clear width of the corridor shall be governed by the width of the plot and stipulation made under these rules. However, the total coverage shall continue to be governed by the parking requirements mentioned above with adequate provision, made both in front and rear of the site. (d) Approach to upper floors in case of double storeyed shops, shop-cum- offices or shops can also be permitted from the public corridor. (e) Approach to basement floors shall be permitted only from within the booth or shops or shop-cum-offices. (f) All Government commercial site planned for Retail outlet shall be governed by approved layout plan or zoning plan or standard architectural control sheets prepared by the concerned Development Authorities. Serial Parameter Permissible Limits as per Plot Size (sq.m) Num- Category Booth Shops/ shop Shops/ shop cum ber cum offices offices PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2327 (g) In case of Shop-cum-Offices (SCO), common staircase or common elevator is permissible maximum for two Shop-cum-Offices subject to the condition that the minimum clear width of staircase shall be 1500 mm: Provided that if common lift is given, then the minimum clear width of staircase shall not be less than 1220 mm (4'-0"). (2) Commercials such as Shopping Mall or Shopping Complex or a Building primarily used for Display and Sale of Merchandise or any Similar Purpose; Miniplex; Multiplex Serial Parameter Permissible Limits Num- Category Shopping Mall Miniplex Multiplex ber or Shopping Complex 1. Minimum Set 6m minimum from site boundary and as per sub rule (1) of back required: - rule 26 of these building rules. 2. Maximum Road FAR Road FAR Road FAR permissible Floor width width width Area Ratio (FAR) 24m 1:2.5 18m 1:2.0 24m 1:2.0 as per approach 30m 1:3.0 30m 1:2.5 30m 1:2.5 road. 45m Unlimited 45m Unlimited 3. Maximum 45 percent of 40 percent of 40 percent of Permissible plot area plot area plot area Ground Coverage 4. Maximum No Restriction subject to the fulfilment of norms such as Permissible Height setbacks around building, ground coverage, Floor Area Ratio, structural safety and fire safety norms. However, clearance from Airport Authority of India or Indian Air Force is required in case the height of the building is 15m or more or site falls in the red colour of home grid of Colour Coded Zoning Map issued by Airports Authority of India or Indian Air Force. 5. Plinth Level 450mm or as specified by competent authority (from the crown of adjoining road in front). Provided that for a detached building, the plinth level may be more than 450mm: Provided further that the level of front courtyard of any building shall not exceed 450 mm and the ramp from the front road to the courtyard shall be within the plot boundary. PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2328 6. Habitable Rooms Component Min. area Min. Min. of Building (SQ.M) Width Clear (M) Height (M) Habitable room 9.5 2.4 2.75 Bathroom 1.8 1.2 2.1 Water Closet 1.2 0.9 2.1 (W.C.) combined bath 2.8 1.2 2.1 and w.c Store 3 1.2 2.2 7. Light and Ventilation (a) one or more openings, such as windows and ventilators, opening directly to the external air or into an open Verandah. (b) such openings, excluding doors inclusive of frames, shall not be less than one-tenth of the floor area. In case of Kitchen such opening shall be increased by 25 percent. 8. Ventilation Shaft the size of ventilation shaft shall not be less than the values given below:- Height of building Size (sq.m) Min. one dimension 10m 1.2 0.9 m 12m 2.8 1.2 m 18m 4.0 1.5 m 24m 5.4 1.8 m 30m 8.0 2.4 m Above 30m 9.0 3.0 m Notes:- (a) For buildings of height above 30 m, a mechanical ventilation system shall be installed besides the provision of minimum ventilation shaft. (b) For fully air conditioned the ventilation shaft need not be insisted upon, provided the air conditioning system works in an uninterrupted manner, also, provided there is an alternative source of power supply. Serial Parameter Permissible Limits Num- Category Shopping Mall Miniplex Multiplex ber or Shopping Complex PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2329 (c) Mechanical ventilation in building shall be as per the provision of the National Building Code of India, 2016, as amended from time to time. 9. Interior Courtyard Minimum area: 9 sq.m Minimum width: 2.4m or 1/5 of the average height of the building, whichever is more. 10. Staircase requirement: Minimum Width 1500mm or as 2000mm or as 2000mm or as per occupant per occupant per occupant load whichever load whichever load whichever is more is more is more Minimum Tread 300 mm 300 mm 300 mm Maximum Riser 150 mm 150 mm 150 mm Minimum Clear 2200 mm 2200 mm 2200 mm Head Height 11. Lift and Ramp Lift is mandatory in buildings 15m or more in height and requirement basement provided more than one level as per the provision of the National Building Code of India, 2016. Ramp requirement for pedestrians, differently-abled, elderly and children upto Plinth Level :- Min. Width - 1800mm Min. Slope - 1:12 12. Mumty Allowed upto 2.75 m, otherwise counted towards the height of the building as well as Floor Area Ratio. 13. Services in terrace Solar Photo Voltaic installation, Water tank, Rain water pipes with drainage, Water Tank, cooling towers for air conditioning plants, mumty, machine room and screening parapet to hide services or as per the provisions of the National Building Code of India, 2016. Serial Parameter Permissible Limits Num- Category Shopping Mall Miniplex Multiplex ber or Shopping Complex PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2330 14. Gate and post check Watch and ward cabins upto 100 sq.ft along each entry gate exempted from Ground Coverage and Floor Area Ratio (FAR). 15. Boundary wall Maximum height allowed: - Facing road or open area: upto 0.9m solid wall with 0.9m high perforated Grill/Jali. Facing other property: upto 1.83m solid wall Minimum Turning Radius for corner plot: - 5’-0” or 1/8th of the adjoining road width, whichever is more and maximum upto 20’-0”. 16. Basement Plot size upto 2025 sq.m: single story basement is allowed upto zoned area or upto the boundary of the plot except front and rear side, as the case may be, subject to the condition that the owner shall leave minimum 2.44 m (8'-0") setback from the respective side of the boundary wall of the plot, if adjoining plot has a building upto 2.44m from the plot line. Plot size above 2025 sq.m: The multi-level basement shall be allowed below the ground and beyond the building line at ground level subject to a clear minimum front margin of 4.5 m and side and rear margins of 3 m, subject to the provision of mechanical ventilation and all safety provisions and drainage. Basement shall not be allowed in the case of No construction Zone/ Area or Master Plan Green area or any other restricted area/zone under the provision of any other Act/policy of the State or Central Government. Minimum clear height for basement shall be as below: • Non-Habitable use: 2.40 m • Habitable Use: 2.75 m Serial Parameter Permissible Limits Num- Category Shopping Mall Miniplex Multiplex ber or Shopping Complex PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2331 17. Vehicular Ramp Ramps are mandatory for plot size above 3000 sq.m. Minimum width: 7.2m for two way traffic 4m for one way traffic Slope: i) Cars not less than 1:8 and at curve 1:12 ii) Heavy not less than 1:15 vehicles 18. Minimum Parking 2 Equivalent Car Miniplex Multiplex Space required Spaces /100sq.m. component: component: of total Floor Area 3 Equivalent 3 Equivalent Ratio area Car Spaces / Car Spaces / 100sq.m. of 100sq.m. of total Floor Area total Floor Area Ratio area Ratio area + 30 Commercial percent of the component: FAR that area 2 Equivalent Commercial Car Spaces / component: 100sq.m. of 2 Equivalent total Floor Area Car Spaces / Ratio area 100sq.m. of total Floor Area Ratio area In buildings of mercantile (commercial), in addition to the parking spaces provided, a space at the rate of 3.5m x 7.5m, shall be provided for loading unloading activities for each 1000m² of Floor Area Ratio area or fraction thereof. 19. Minimum width 1500 mm for 2000 mm or as 2000 mm or as single loaded and per occupant per occupant 1800 mm for load whichever load whichever double loaded or is more is more as per occupant load whichever is more Serial Parameter Permissible Limits Num- Category Shopping Mall Miniplex Multiplex ber or Shopping Complex PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2332 20. Rain Water Required Harvesting System 21. Solar Water Recommended to meet its hot water demand from solar Heating System water heaters, as far as possible 22. Solar Photo Voltaic Connected Load Minimum requirement a) 50 KWp to 1000 KWp: Minimum 10 Kilo Watt peak or 5 percent of connected load, whichever is higher b) Above 1000 KWp: Minimum 50 Kilo Watt peak or 3 percent of connected load, whichever is higher. 23. Flushing System Provision of dual button type flushing cistern in each water closet. 24. Parapet or Railing Minimum Height: 1.0 m Maximum Height: 1.4 m from the finished floor level 25. Amalgamation or Amalgamation allowed Fragmentation Fragmentation not allowed Notes: (a) *Unlimited Floor Area Ratio shall be subject to fulfilment of building controls such as ground coverage, setbacks around building, parking norms, light and ventilation, height, fire and structural safety. (b) The Floor Area Ratio above 1:1.75 in case of commercial building, will be chargeable on pro-rata basis. However, the site allotted or sold by the development authority the charges shall be applicable as per the terms and conditions of the allotment letter. (c) In case of Multiplex/ Miniplex or Cinema the physical and development norms as specified in the multiplex/ Miniplex policy or the Punjab Cinemas (Regulation) Act, 1952, as amended from time to time, shall be applicable, however, for any provision not specified /covered under above policies, these rules shall be applicable. (d) In case any provision is not specified /covered under these rules then the physical and development norms as specified in the multiplex/ Miniplex policy or the Punjab Cinemas (Regulation) Act, 1952, as the case may be, shall be applicable. (e) Commercial component such as retail, shopping restaurant, food courts etc. are permissible in miniplex/ multiplex. Serial Parameter Permissible Limits Num- Category Shopping Mall Miniplex Multiplex ber or Shopping Complex PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2333 (3) Hotel or Motel; Club and Guest House/ Lodging & Boarding/ Service Apartments Serial Parameter Permissible Limits Num- Category Hotel or Motel Club Guest ber House/ Lodging & Boarding/ Service Apartments 1. Minimum 12m 18m 24m 18m 24m 12m 18m Approach Road 2. Permissible/ 1000 2000 Above 1000 Above 1000 Above Minimum upto upto 4000 upto 2000 upto 2000 Plot size 2000 4000 sq.yd 2000 sq.yd 2000 sq. mt sq.yd sq.yd sq.mt sq.mt 3. Minimum Set 6m minimum from site boundary and as per sub rule (1) of rule back required:- 26 of these building rules. However, for the plots upto 2025 sq.m area where width of the plot is less than 30.50m (100'-0") and the maximum height of building is below 15m excluding the architectural and symbolism element of religious building like dome, minarets, sikharas, crucifix etc. from building height, then one side setbacks may be relaxed subject to the condition that the owner has to submit a fire safety certificate from the competent authority in this regard. 4. Maximum Minimum Minimum Minimum Permissible Road width FAR Road width FAR Road width FAR Floor Area 24m 1:2.0 18m 1:1.0 12m 1:1.0 Ratio(FAR) as 30m 1:2.5 24m 1:1.0 18m 1:2.0 per approach 45m Unlimited road 5. Maximum 40 percent of plot 40 percent of plot 40 percent of plot Permissible area area area Ground Coverage PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2334 6. Plinth Level 450mm or as specified by competent authority (from the crown of adjoining road in front). Provided that for a detached building, the plinth level may be more than 450mm: Provided further that the level of front courtyard of any building shall not exceed 450 mm and the ramp from the front road to the courtyard shall be within the plot boundary. 7. Maximum No Restriction subject to the fulfilment of norms such as setbacks Permissible around building, ground coverage, Floor Area Ratio, structural Height safety and fire safety norms. However, clearance from Airport Authority of India or Indian Air Force is required in case the height of the building is 15m or more or site falls in the red colour of home grid of Colour Coded Zoning Map issued by Airports Authority of India or Indian Air Force. 8. Minimum Component of Min. area Min. Width Min. Clear requirements Building (SQ.M) (M) Height (M) of different Habitable room 9.5 2.4 2.75 component of Kitchen a building • where separate 5 1.8 dining area is provided • where separate 4.5 1.8 2.75 store is provide • where dinning 7.5 2.1 included Bathroom 1.8 1.2 2.1 Water Closet 1.2 0.9 2.1 ( W.C.) combined bath 2.8 1.2 2.1 and w.c Store 3 1.2 2.2 Garage 18 3 2.4 Serial Parameter Permissible Limits Num- Category Hotel or Motel Club Guest ber House/ Lodging & Boarding/ Service Apartments PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2335 9. Light and (a) one or more openings, such as windows and ventilators, Ventilation opening directly to the external air or into an open Verandah. (b) such openings, excluding doors inclusive of frames, shall not be less than one-tenth of the floor area. In case of Kitchen such opening shall be increased by 25 percent. 10. Ventilation the size of ventilation shaft shall not be less than the values Shaft given below:- Height of building Size (sq.m) Min. one dimension 10m 1.2 0.9 m 12m 2.8 1.2 m 18m 4.0 1.5 m 24m 5.4 1.8 m 30m 8.0 2.4 m Above 30m 9.0 3.0 m Notes:- (a) For buildings of height above 30 m, a mechanical ventilation system shall be installed besides the provision of minimum ventilation shaft. (b) For fully air conditioned the ventilation shaft need not be insisted upon, provided the air conditioning system works in an uninterrupted manner, also, provided there is an alternative source of power supply. (c) Mechanical ventilation in building shall be as per the provision of the National Building Code of India, 2016, as amended from time to time. Serial Parameter Permissible Limits Num- Category Hotel or Motel Club Guest ber House/ Lodging & Boarding/ Service Apartments PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2336 11. Staircase requirement: Minimum 1500 mm or as 2000 mm or 1500 mm or Width per occupant per occupant per occupant load whichever load whichever load whichever is more is more is more Minimum 300 mm 300 mm 300 mm Tread Maximum 150mm 150mm 150mm Riser Minimum 2200mm 2200mm 2200mm Clear Head Height 12. Lift and Ramp Lift is mandatory in buildings 15m or more in height and Requirement basement provided more than one level as per the provision of the National Building Code of India, 2016. Ramp requirement for pedestrians, differently-abled, elderly and children upto Plinth Level :- Min. Width - 1800mm Min. Slope - 1:12 13. Services in Solar Photo Voltaic installation, Water tank, Rain water pipes terrace with drainage, Water Tank, cooling towers for air conditioning plants, mumty, machine room and screening parapet to hide services or as per the provisions of National Building Code-2016. 14. Gate and Watch and ward cabins upto 100 sq.ft along each entry gate post check exempted from Ground Coverage and Floor Area Ratio (FAR). 15. Boundary wall Maximum height allowed: - Facing road or open area: upto 0.9m solid wall with 0.9m high perforated Grill/Jali. Serial Parameter Permissible Limits Num- Category Hotel or Motel Club Guest ber House/ Lodging & Boarding/ Service Apartments PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2337 Facing other property: upto 1.83m solid wall. Minimum Turning Radius for corner plot: - 5’-0” or 1/8th of the adjoining road width, whichever is more and maximum upto 20’-0” 16. Basement Plot size upto 2025 sq.m: single story basement is allowed upto zoned area or upto the boundary of the plot except front and rear side, as the case may be, subject to the condition that the owner shall leave minimum 2.44 m (8'-0") setback from the respective side of the boundary wall of the plot, if adjoining plot has a building upto 2.44m from the plot line. Plot size above 2025 sq.m: The multi-level basement shall be allowed below the ground and beyond the building line at ground level subject to a clear minimum front margin of 4.5 m and side and rear margins of 3 m, subject to the provision of mechanical ventilation and all safety provisions and drainage. Basement shall not be allowed in the case of No construction Zone/ Area or Master Plan Green area or any other restricted area/zone under the provision of any other Act/policy of the State or Central Government. Minimum clear height for basement shall be as below: • Non-Habitable use: 2.40 m • Habitable Use: 2.75 m 17. Vehicular Ramps are mandatory for plot size above 3000 sq.m. Ramp Minimum width: 7.2m for two way traffic 4m for one way traffic Slope: i) Cars not less than 1:8 and at curve 1:12 ii) Heavy not less than 1:15 vehicles Serial Parameter Permissible Limits Num- Category Hotel or Motel Club Guest ber House/ Lodging & Boarding/ Service Apartments PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2338 18. Minimum 2 Equivalent Car 3 Equivalent Car 1.5 Equivalent Car Parking Spaces /100sq.m. Spaces /100sq.m. Spaces /100sq.m. Space of total Floor of total Floor of total Floor required Area Ratio area Area Ratio area Area Ratio area 19. Projection/ 1.83 m wide balcony (Free from Ground Coverage and Floor area ratio) 20. Rain Water Required Harvesting System 21. Solar Water Not mandatory but recommended to meet its hot water demand Heating from solar water heaters, as far as possible System 22. Solar Photo Connected Load Minimum requirement Voltaic a) 50 KWp to 1000 KWp Minimum 10 Kilo Watt peak or 5 percent of connected load, whichever is higher. b) Above 1000 KWp Minimum 50 Kilo Watt peak or 3 percent of connected load, whichever is higher. 23. Flushing System Provision of dual button type flushing cistern in each water closet. 24. Parapet or Minimum Height: 1.0 m Railing Maximum Height: 1.4 m from the finished floor level 25. Minimum width 1500 mm for single 2000 mm or as 1500 mm for single of corridor or loaded and 1800 mm per occupant load loaded and 1800 mm Passage for double loaded or whichever is more for double loaded or as as per occupant load per occupant load whichever is more whichever is more Serial Parameter Permissible Limits Num- Category Hotel or Motel Club Guest ber House/ Lodging & Boarding/ Service Apartments PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2339 26. Amalgamation Amalgamation allowed or Fragmentation not allowed Fragmentation Notes: a) *In rural areas outside Master Plans, the Hotel activity upto one acre area shall be permissible on link roads having minimum width of 22’-0” (4 karam). However, the developer has to widen the road to minimum 40 feet or as specified in the Master Plan whichever is more, by leaving proportionate area from his own land. b) Commercial use within the Hotel Building envelope shall be permissible as per the policy of State Government, as amended from time to time. c) **Unlimited Floor Area Ratio shall be subject to fulfillment of building controls such as ground coverage, setbacks around building, parking norms, light and ventilation, height, fire and structural safety. d) The Floor Area Ratio above 1:3 in case of hotel building, will be chargeable on pro-rata basis. However, the site allotted or sold by the development authority the charges shall be applicable as per the terms and conditions of the allotment letter. (4) Wholesale Trade or Integrated Freight Complex (Standalone); Warehouse or Godown (Standalone) Serial Parameter Permissible Limits Number Category Wholesale Trade or Integrated Warehouse or Godown Freight Complex (Standalone) (Standalone) 1. Minimum Plot 1 Hectare 2000 sq. mt size 2. Minimum Set 6m minimum from site boundary and as per sub rule (1) of back around these building rules. building However, for the plots upto 2025 sq.m area where width of the required plot is less than 30.50m (100'-0") and the maximum height of building is below 15m excluding the architectural and symbolism element of religious building like dome, minarets, sikharas, crucifix etc. from building height, Serial Parameter Permissible Limits Num- Category Hotel or Motel Club Guest ber House/ Lodging & Boarding/ Service Apartments PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2340 then one side setbacks may be relaxed subject to the condition that the owner has to submit a fire safety certificate from the competent authority in this regard. 3. Maximum 1:1.0 1:1.0 Permissible Floor Area Ratio 4. Maximum 40 percent of Site area 65 percent of Site area Permissible Ground Coverage 5. Plinth Level 450mm or as specified by competent authority (from the crown of adjoining road in front). Provided that for a detached building, the plinth level may be more than 450mm: Provided further that the level of front courtyard of any building shall not exceed 450 mm and the ramp from the front road to the courtyard shall be within the plot boundary. 6. Maximum No Restriction subject to the fulfilment of norms such as Permissible setbacks around building, ground coverage, Floor Area Ratio, Height structural safety and fire safety norms. However, clearance from Airport Authority of India or Indian Air Force is required in case the height of the building is 15m or more or site falls in the red colour of home grid of Colour Coded Zoning Map issued by Airports Authority of India or Indian Air Force. 7. Number of Subject to the fulfilment of the setbacks around the building as storey per the height of the building. 8. Minimum Component of Building Min. Min. Min. Clear equirements of area Width Height different (SQ.M) (M) (M) component of Habitable room 9.5 2.4 2.75 a building Bathroom 1.8 1.2 2.1 Serial Parameter Permissible Limits Number Category Wholesale Trade or Integrated Warehouse or Godown Freight Complex (Standalone) (Standalone) PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2341 Water Closet ( W.C.) 1.2 0.9 2.1 combined bath and w.c 2.8 1.2 2.1 Store 3 1.2 2.2 Garage 18 3 2.4 9. Light and (a) one or more openings, such as windows and ventilators, Ventilation opening directly to the external air or into an open Verandah. (b) such openings, excluding doors inclusive of frames, shall not be less than one-tenth of the floor area. In case of Kitchen such opening shall be increased by 25 percent. 10. Ventilation the size of ventilation shaft shall not be less than the values Shaft given below:- Height of building Size (sq.m) Min. one dimension 10m 1.2 0.9 m 12m 2.8 1.2 m 18m 4.0 1.5 m 24m 5.4 1.8 m 30m 8.0 2.4 m Above 30m 9.0 3.0 m Notes:- (a) For buildings having height 30 m or above, a mechanical ventilation system shall be installed besides the provision of minimum ventilation shaft. (b) For fully air conditioned the ventilation shaft need not be insisted upon, provided the air conditioning system works in an uninterrupted manner, also, provided there is an alternative source of power supply. (c) Mechanical ventilation in building shall be as per the provision of the National Building Code of India, 2016, as amended from time to time. 11. Staircase Minimum Width: 2000 mm Minimum Width: 1500 mm requirement: - Minimum Tread: 300 mm Minimum Tread: 300 mm Maximum Riser: 150 mm Maximum Riser: 150 mm Minimum Clear Minimum Clear Head Height: 2200 mm Head Height: 2200 mm Serial Parameter Permissible Limits Number Category Wholesale Trade or Integrated Warehouse or Godown Freight Complex (Standalone) (Standalone) PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2342 12. Lift and Ramp Lift is mandatory in buildings 15m or more in height and Requirement basement provided more than one level as per the provision of the National Building Code of India, 2016. Ramp requirement for pedestrians, differently-abled, elderly and children upto Plinth Level :- Min. Width - 1800mm Min. Slope - 1:12 13. Services in Solar Photo Voltaic installation, Water tank, Rain water pipes terrace with drainage, Water Tank, cooling towers for air conditioning plants, mumty, machine room and screening parapet to hide services or as per the provisions of the National Building Code of India, 2016. 14. Gate and post Watch and ward cabins upto 100 sq.ft along each entry gate check exempted from Ground Coverage and Floor Area Ratio (FAR). 15. Boundary wall Maximum height allowed: - Facing road or open area: upto 0.9m solid wall with 0.9m high perforated Grill/Jali. Facing other property: upto 1.83m solid wall. Minimum Turning Radius for corner plot: - 5’-0” or 1/8th of the adjoining road width, whichever is more and maximum upto 20’-0” 16. Basement Plot size upto 2025 sq.m: single story basement is allowed upto zoned area or upto the boundary of the plot except front and rear side, as the case may be, subject to the condition that the owner shall leave minimum 2.44 m (8'-0") setback from the respective side of the boundary wall of the plot, if adjoining plot has a building upto 2.44m from the plot line. Plot size above 2025 sq.m: The multi-level basement shall be allowed below the ground and beyond the building line at ground Serial Parameter Permissible Limits Number Category Wholesale Trade or Integrated Warehouse or Godown Freight Complex (Standalone) (Standalone) PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2343 level subject to a clear minimum front margin of 4.5 m and side and rear margins of 3 m, subject to the provision of mechanical ventilation and all safety provisions and drainage. Basement shall not be allowed in the case of No construction Zone/ Area or Master Plan Green area or any other restricted area/zone under the provision of any other Act/ policy of the State or Central Government. Minimum clear height for basement shall be as below: • Non-Habitable use: 2.40 m • Habitable Use: 2.75 m Stilt, if • Clear Height shall be 7’-6”. provided (Non- • Parking provided under stilts shall not be habitable counted towards Floor Area Ratio and height. height) 17. Vehicular Ramp Ramps are mandatory for plot size above 3000 sq.m. Minimum width: 7.2m for two way traffic 4m for one way traffic Slope: i) Cars not less than 1:8 and at curve 1:12 ii) Heavy vehicles not less than 1:15 18. Minimum 2 Equivalent Car Spaces/100 1 Equivalent Car Spaces /100 Parking Space sq.m of total Floor Area Ratio sq.m of total Floor Area Ratio area. area. In addition to the parking spaces provided, a space at the rate of 3.5m x 7.5m, shall be provided for loading unloading activities for each 1000 m² of floor area or fraction thereof. 19. Projection or 1.83 m wide balcony (Free from Ground Coverage and Floor Area Ratio) 20. Rain Water Required Harvesting System Serial Parameter Permissible Limits Number Category Wholesale Trade or Integrated Warehouse or Godown Freight Complex (Standalone) (Standalone) PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2344 21. Solar Water Recommended to meet its hot water demand from solar water Heating System heaters, as far as possible 22. Solar Photo Connected Load Minimum requirement Voltaic required a)50 KWp to 1000 KWp Minimum 10 Kilo Watt peak or 5 as per plot size percent of connected load, whichever is higher. b) Above 1000 KWp Minimum 50 Kilo Watt peak or3 percent of connected load, whichever is higher. 23. Flushing System Provision of dual button type flushing cistern in each water closet. 24. Parapet or Minimum Height: 1.0 m Railing Maximum Height: 1.4 m from the finished floor level 25. Minimum 1500 mm for single loaded and 1800 mm for double loaded or passage or as per occupant load whichever is more. corridor 26. Amalgamation Amalgamation allowed or Fragmentation Fragmentation not allowed Notes:- a) For Risk based approval of types of Warehouses or Integrated Freight complex (IFC) refer sub-rule (1) of rule 46. (B) Petrol pumps or Filling -cum-service stations.- Petrol Pump or filling-cum-service stations or two-three wheelers petrol pump shall be governed as per instructions or guidelines of Indian Roads Congress (IRC) or Ministry of Road Transport and Highways (MORTH) or Town and Country Planning Organisation (TCPO) or Department of Housing and Urban Development, Government of Punjab. However, every Petrol Pump or Filling-cum-Service Stations shall have a charging station for electric drive vehicle. Serial Parameter Permissible Limits Number Category Wholesale Trade or Integrated Warehouse or Godown Freight Complex (Standalone) (Standalone) PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2345 5 (A) INDUSTRIAL.- The industrial buildings of various types shall be governed by the following norms, namely:- (1) Low Rise Industry Serial Parameter Permissible Limits Number Category General Industry Information Technology 1. Minimum 15 m (Minimum 16’-6” 15 m (Minimum 16’-6” Approach widen to 50’0”) or as per widen to 50’0”) or as Road master plan whichever is per master plan more whichever is more 2. Minimum Set Open spaces around the 6m minimum from site back around building shall not be less boundary and as per sub rule building than 4.5m. (1) of rule 26 of these building required rules. However, for industrial plots (including I.T Buildings) upto 2025 sq.m area where width of the plot is less than 30.50 m (100'-0"), the front and rear set back shall be ¼ of the height or 2m whichever is more are mandatory. The side setbacks may be relaxed subject to the condition that the owner has to submit a fire safety certificate from the competent authority in this regard. 3. Maximum Unlimited Unlimited Permissible Floor Area Ratio 4. Maximum 65 percent of Site area 65 percent of Site area Permissible **5 percent additional Ground ground coverage shall be Coverage permitted in case of retail service industry 5. Plinth Level 450mm or as specified by competent authority (from the crown of adjoining road in front). Provided that for a detached building, the plinth level may be more than 450mm: Provided further that the level of front courtyard of any building shall not exceed 450 mm and the ramp from the front road to the courtyard shall be within the plot boundary. Section 180 (2) PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2346 6. Maximum Below 15 m Permissible (Excluding equipment, machinery such as chimney, boiler, plant, Height hammer, silos, etc. irrespective of its height) However, clearance from Airport Authority of India or Indian Air Force is required in case site falls in the red colour of home grid of Colour Coded Zoning Map issued by Airports Authority of India or Indian Air Force. 7. Minimum 3.6m, except when air-conditioned where it is 3m. Clear Ceiling Height for industrial area 8. Minimum Component of Building Min. Min. Min. requirements area Width Clear of different (SQ.M) (M) Height (M) component of Habitable room 9.5 2.4 2.75 a building Bathroom 1.8 1.2 2.1 Water Closet ( W.C.) 1.2 0.9 2.1 combined bath and w.c 2.8 1.2 2.1 Store 3 1.2 2.2 Garage 18 3 2.4 9. Light and (a) one or more openings, such as windows and ventilators, Ventilation opening directly to the external air or into an open Verandah. (b) such openings, excluding doors inclusive of frames, shall not be less than one-tenth of the floor area. In case of Kitchen such opening shall be increased by 25 percent. 10. Ventilation the size of ventilation shaft shall not be less than the values Shaft given below: Height of building Size (sq.m) Min. one dimension 10m 1.2 0.9 m 12m 2.8 1.2 m 18m 4.0 1.5 m Notes: (a) For fully air conditioned the ventilation shaft need not be insisted upon, provided the air conditioning system works in an uninterrupted manner, also, provided there is an alternative source of power supply. Serial Parameter Permissible Limits Number Category General Industry Information Technology PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2347 (b) Mechanical ventilation in building shall be as per the provision of the National Building Code of India, 2016, as amended from time to time. 11. Staircase Minimum Width: 1500 mm Minimum Width: 1500 mm requirement: Minimum Tread: 300 mm Minimum Tread: 300 mm Maximum Riser: 150 mm Maximum Riser: 150 mm Minimum Clear Minimum Clear Head Height: 2200 mm Head Height: 2200 mm 12. Lift and Ramp Lift is mandatory if basement provided more than one level as Requirement per the provision of the National Building Code of India, 2016. Ramp requirement for pedestrians, differently-abled, elderly and children upto Plinth Level :- Min. Width - 1800mm Min. Slope - 1:12 13. Services in Solar Photo Voltaic installation, Water tank, Rain water pipes terrace with drainage, Water Tank, cooling towers for air conditioning plants, mumty, machine room and screening parapet to hide services or as per the provisions of the National Building Code Of India, 2016. 14. Gate and Watch and ward cabins upto 100 sq.ft along each entry gate post check exempted from Ground Coverage and Floor Area Ratio (FAR). 15. Boundary wall Maximum height allowed: - Facing road or open area: upto 0.9m solid wall with 0.9m high perforated Grill/Jali. Facing other property: upto 1.83m solid wall. Minimum Turning Radius for corner plot: - 5’-0” or 1/8th of the adjoining road width, whichever is more and maximum upto 20’-0” 16. Basement Plot size upto 2025 sq.m: single storey basement is allowed upto zoned area subject to the condition that the owner shall leave minimum 2.44 m (8'-0") setback from the boundary wall of the plot. Plot size above 2025 sq.m: The multi-level basement shall be allowed below the ground and beyond the building line at ground level subject to a clear minimum front margin of 4.5 m and side and rear margins of 3 m, subject to the provision of mechanical ventilation and all safety provisions and drainage. Serial Parameter Permissible Limits Number Category General Industry Information Technology PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2348 Basement shall not be allowed in the case of No construction Zone/ Area or Master Plan Green area or any other restricted area/zone under the provision of any other Act/ policy of the State or Central Government. Minimum clear height for basement shall be as below: • Non-Habitable use: 2.40 m • Habitable Use: 2.75 m 17. Vehicular Ramp Ramps are mandatory for plot size above 3000 sq.m. Minimum width: 7.2m for two way traffic 4m for one way traffic Slope: i) Cars not less than 1:8 and at curve 1:12 ii) Heavy vehicles not less than 1:15 18. Minimum 1 Equivalent Car Space /100 2 Equivalent Car Spaces/100 Parking sq.m of total Floor Area sq.m of total Floor Area required Ratio area. Ratio area. In addition to the parking spaces provided, a space at the rate of 3.5m x 7.5m, shall be provided for loading unloading activities for each 1000 m² of floor area or fraction thereof. 19. Projection Size of Plot Maximum allowable projection (Free from a) Upto 250 sq.m 1/3 of the corresponding depth of Ground rear front or setback or0.91m (3'-0"), Coverage whichever is less. and Floor b) Above 250 sq.m 1.83 meter (6'-0") Area Ratio) 20. Balcony (Free Size of Plot Maximum allowable Balcony from Ground a) Upto 250 sq.m 1/3 of the corresponding depth of Coverage and rear front or setback or 1.22m (4'-0"), Floor Area whichever is less. Ratio) b) Above 250 sq.m 1.83 meter (6'-0") 21. Rain Water Required Harvesting System Serial Parameter Permissible Limits Number Category General Industry Information Technology PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2349 22. Solar Water Not mandatory but recommended to meet its hot water demand Heating System from solar water heaters, as far as possible 23. Solar Photo Connected Load Minimum requirement Voltaic required a)50 KWp to 1000 KWp Minimum 10 Kilo Watt peak or 5 as per plot size percent of connected load, whichever is higher. b) Above 1000 KWp Minimum 50 Kilo Watt peak or3 percent of connected load, whichever is higher. 24. Flushing System Provision of dual button type flushing cistern in each water closet. 25. Parapet or Minimum Height: 1.0 m Railing Maximum Height: 1.4 m from the finished floor level 26. Minimum 1500 mm for single loaded and 1800 mm for double loaded or passage or as per occupant load whichever is more. corridor 27. Residential Upto 15 percent of the total Floor Area Ratio area in industrial buildings shall be permissible for the housing of staff or workers. Notes:- a) 5 percent additional ground coverage shall be permitted in case of retail service industry. b) *Unlimited Floor Area Ratio shall be subject to fulfilment of building controls such as ground coverage, setbacks around building, parking norms, light and ventilation, height, fire and structural safety. c) In case of Industrial Estate/ Private Industrial Areas or Conglomeration of Industries opt for central parking then: (i) Minimum 20 percent parking shall be within the premises of the industry. (ii) The parking requirement if provided in mechanical/ common pool area shall be duly certified by the concerned association by whom it is being maintained. (iii) The share of common parking shall be calculated as per the total area of the industrial plot duly certified by the concerned agency maintaining that parking. (iv) In case any false claim regarding common parking is observed then the industrial plot holder has to provide parking in his own premises. Serial Parameter Permissible Limits Number Category General Industry Information Technology PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2350 (2) High Rise Industry Serial Parameter Permissible Limits Number Category General Industry Information Technology 1. Minimum 18 m 18 m Approach Road 2. Minimum Set Open spaces around the 6m minimum from site boundary and back around building shall not be less as per sub rule (1) of rule 26 of these building required than 4.5m for height upto building rules. 15 m, with an increase of the open spaces of 0.25 m for every increase of 1 m or fraction thereof in height above 15m. However, for industrial plots (including I.T Buildings) upto 2025 sq.m area where width of the plot is less than 30.50 m (100'- 0"), the front and rear set back shall be ¼ of the height or 2m whichever is more are mandatory. The side setbacks may be relaxed subject to the condition that the owner has to submit a fire safety certificate from the competent authority in this regard. 3. Maximum Unlimited Unlimited Permissible Floor Area Ratio 4. Maximum 65 percent of Site area 65 percent of Site area Permissible **5 percent additional Ground ground coverage shall be Coverage permitted in case of retail service industry 5. Plinth Level 450mm or as specified by competent authority (from the crown of adjoining road in front). Provided that for a detached building, the plinth level may be more than 450mm: Provided further that the level of front courtyard of any building shall not exceed 450 mm and the ramp from the front road to the courtyard shall be within the plot boundary. 6. Maximum No Restriction subject to the fulfilment of norms such as Permissible setbacks around building, ground coverage, Floor Area Ratio, Height structural safety and fire safety norms. PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2351 However, clearance from Airport Authority of India or Indian Air Force is required in case the height of the building is 15m or more or site falls in the red colour of home grid of Colour Coded Zoning Map issued by Airports Authority of India or Indian Air Force. 7. Minimum Clear 3.6m, except when air-conditioned where it is 3m. Ceiling Height for industrial area 8. Minimum Component of Building Min. Min. Min. Clear requirements of area Width Height different (SQ.M) (M) (M) component of Habitable room 9.5 2.4 2.75 a building Bathroom 1.8 1.2 2.1 Water Closet ( W.C.) 1.2 0.9 2.1 combined bath and w.c 2.8 1.2 2.1 Store 3 1.2 2.2 Garage 18 3 2.4 9. Light and (a) one or more openings, such as windows and ventilators, Ventilation opening directly to the external air or into an open Verandah. (b) such openings, excluding doors inclusive of frames, shall not be less than one-tenth of the floor area. In case of Kitchen such opening shall be increased by 25 percent. 10. Ventilation Shaft the size of ventilation shaft shall not be less than the values given below:- Height of building Size (sq.m) Min. one dimension 10m 1.2 0.9 m 12m 2.8 1.2 m 18m 4.0 1.5 m 24m 5.4 1.8 m 30m 8.0 2.4 m Above 30m 9.0 3.0 m Notes:- (a) For buildings of height above 30 m, a mechanical ventilation system shall be installed besides the provision of minimum ventilation shaft. (b) For fully air conditioned the ventilation shaft need not be insisted upon, provided the air conditioning system works in Serial Parameter Permissible Limits Number Category General Industry Information Technology PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2352 an uninterrupted manner, also, provided there is an alternative source of power supply. (c) Mechanical ventilation in building shall be as per the provision of the National Building Code of India, 2016, as amended from time to time. 11. Staircase Minimum Width: 1500 mm Minimum Width: 1500 mm requirement: Minimum Tread: 300 mm Minimum Tread: 300 mm Maximum Riser: 150 mm Maximum Riser: 150 mm Minimum Clear Minimum Clear Head Height: 2200 mm Head Height: 2200 mm 12. Lift and Ramp Lift is mandatory in buildings 15m or more in height and Requirement basement provided more than one level as per the provision of the National Building Code of India, 2016. Ramp requirement for pedestrians, differently-abled, elderly and children upto Plinth Level :- Min. Width - 1800mm Min. Slope - 1:12 13. Services in Solar Photo Voltaic installation, Water tank, Rain water pipes terrace with drainage, Water Tank, cooling towers for air conditioning plants, mumty, machine room and screening parapet to hide services or as per the provisions of the National Building Code Of India, 2016. 14. Gate and post Watch and ward cabins upto 100 sq.ft along each entry gate check exempted from Ground Coverage and Floor Area Ratio (FAR). 15. Boundary wall Maximum height allowed: - Facing road or open area: upto 0.9m solid wall with 0.9m high perforated Grill/Jali. Facing other property: upto 1.83m solid wall. Minimum Turning Radius for corner plot: - 5’-0” or 1/8th of the adjoining road width, whichever is more and maximum upto 20’-0” 16. Basement Plot size upto 2025 sq.m: single story basement is allowed upto zoned area or upto the boundary of the plot except front and rear side, as the case may be, subject to the condition that the owner shall leave minimum 2.44 m (8'-0") setback from the respective side of the boundary wall of the plot, if adjoining plot has a building upto 2.44m from the plot line. Serial Parameter Permissible Limits Number Category General Industry Information Technology PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2353 Plot size above 2025 sq.m: The multi-level basement shall be allowed below the ground and beyond the building line at ground level subject to a clear minimum front margin of 4.5 m and side and rear margins of 3 m, subject to the provision of mechanical ventilation and all safety provisions and drainage. Basement shall not be allowed in the case of No construction Zone/ Area or Master Plan Green area or any other restricted area/zone under the provision of any other Act/ policy of the State or Central Government. Minimum clear height for basement shall be as below: • Non-Habitable use: 2.40 m • Habitable Use: 2.75 m Stilt, if provided • Clear Height shall be 7’-6”. (Non-habitable • Parking provided under stilts shall not be counted height) towards Floor Area Ratio and height. 17. Vehicular Ramp Ramps are mandatory for plot size above 3000 sq.m. Minimum width: 7.2m for two way traffic 4m for one way traffic Slope: i) Cars not less than 1:8 and at curve 1:12 ii) Heavy vehicles not less than 1:15 18. Minimum 2 Equivalent Car Spaces/ 2 Equivalent Car Spaces /100 sq.m Parking 100 sq.m of total Floor of total Floor Area Ratio area. required Area Ratio. In addition to the parking spaces provided, a space at the rate of 3.5m x 7.5m, shall be provided for loading unloading activities for each 1000 m² of floor area or fraction thereof. 19. Allowable Size of Plot Maximum allowable projection Projection a) Upto 250 sq.m 1/3 of the corresponding depth of (Free from front or rear setback or0.91m (3'- Floor Area 0"), whichever is less. Ratio) b) Above 250 sq.m 1.83 meter (6'-0") 20. Allowable Size of Plot Maximum allowable Balcony Balcony (Free a) Upto 250 sq.m 1/3 of the corresponding depth of Serial Parameter Permissible Limits Number Category General Industry Information Technology PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2354 from Ground front or rear setback or 1.22m Coverage and (4'-0"), whichever is less. Floor Area b) Above 250 sq.m 1.83 meter (6'-0") Ratio) 21. Rain Water Required Harvesting System 22. Solar Water Not mandatory but recommended to meet its hot water demand Heating System from solar water heaters, as far as possible 23. Solar Photo Connected Load Minimum requirement Voltaic required a)50 KWp to 1000 KWp Minimum 10 Kilo Watt peak or 5 as per plot size percent of connected load, whichever is higher. b) Above 1000 KWp Minimum 50 Kilo Watt peak or3 percent of connected load, whichever is higher. 24. Flushing System Provision of dual button type flushing cistern in each water closet. 25. Parapet or Minimum Height: 1.0 m Railing Maximum Height: 1.4 m from the finished floor level 26. Minimum 1500 mm for single loaded and 1800 mm for double loaded or passage or as per occupant load whichever is more. corridor 27. Residential Upto 15 percent of the total Floor Area Ratio area in industrial buildings shall be permissible for the housing of staff or workers. (B) Other controls for Industrial Buildings.- (i) For industrial plots more than 1000 sq.m, 10 percent of the total plot area shall be reserved as amenity open space. When such amenity open space exceeds 1500 sq.m, the excess area could be utilized for construction of buildings for banks, canteen, welfare centre and such other common purposes. (ii) Upto 15 percent of the total Floor Area Ratio area in industrial buildings shall be permissible for the housing of staff or workers. (iii) Unlimited Floor Area Ratio shall be subject to fulfilment of building controls such as ground coverage, setbacks around building, parking norms, light and ventilation, height, fire and structural safety. Serial Parameter Permissible Limits Number Category General Industry Information Technology PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2355 6 EDUCATIONAL.- The educational buildings of various types shall be governed by the following norms, namely:- (1) Pre Nursery/ Nursery/ Creche; Primary School (Class 1 To 5); High/ Senior Secondary School/ College or Educational Institute/ Universities Serial Parameter Permissible Limits Num- Category Pre Nursery/ Primary School High/ Sr. Sec. ber Nursery/ (Class 1 To 5) School/ College Creche or Edu. Institute/ Universities 1. Minimum Plot 1000 sq.m 5000 sq.m or as As per the norms Size per affiliation of the affiliation authority norms authority. whichever is more. 2. Minimum 12m 12 m Within Master approach road Plan School : 18m College/ : 24m University Outside Master Plan School : 12m College/ : 18m University 3. Minimum Set Front side: 6m minimum from site boundary and as per back required: - 6m or 1/3 table sub rule (1) of rule 26 of these building of the rules. height of However, for the plots upto 2025 sq.m area building, where width of the plot is less than 30.50m whichever (100'-0") and the maximum height of is more building is below 15m excluding the Other Sides: architectural and symbolism element of 4.5m or 1/3 religious building like dome, minarets, of the height sikharas, crucifix etc. from building height, of building, then one side setback may be relaxed subject whichever is to the condition that the owner has to submit more a fire safety certificate from the competent authority in this regard. Section 180 (2) PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2356 4. Maximum 1:1.0 1:1.2 1:1.5 Permissible Floor Area Ratio as per approach road 5. Maximum 40 percent of 40 percent of 40 percent of Permissible plot area plot area plot area Ground Coverage 6. Plinth Level 450mm or as specified by competent authority (from the crown of adjoining road in front). Provided that for a detached building, the plinth level may be more than 450mm: Provided further that the level of front courtyard of any building shall not exceed 450 mm and the ramp from the front road to the courtyard shall be within the plot boundary. 7. Maximum number G+1 and upto Below 15m No Restriction of Floors/height 9m However, However, subject to the of the Building clearance from clearance from fulfilment of Airport Authority Airport Authority norms such as of India or Indian of India or Indian setbacks around Air Force is Air Force is building, ground required in case the required in case coverage, Floor site falls in the red the site falls in Area Ratio, colour of home the red colour of structural safety grid of Colour home grid of and fire safety Coded Zoning Map Colour Coded norms. issued by Airports Zoning Map However, Authority of India issued by Airports clearance from or Indian Air Authority of India Airport Authority Force. or Indian Air of India or Indian Note: only ground Force. Air Force is floor shall be used required in case the for academics height of the however first floor building is 15m or may be used for more or site falls in Serial Parameter Permissible Limits Num- Category Pre Nursery/ Primary School High/ Sr. Sec. ber Nursery/ (Class 1 To 5) School/ College Creche or Edu. Institute/ Universities PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2357 residential, office, the red colour of storage etc. home grid of Colour Coded Zoning Map issued by Airports Authority of India or Indian Air Force. 8. Minimum Clear 3.6m Ceiling Height for academic area 9. Minimum Component Min. Min. Min. requirements of of Building area Width Clear different (SQ.M) (M) Height (M) component of a building Habitable room 9.5 2.4 2.75 Bathroom 1.8 1.2 2.1 Water Closet 1.2 0.9 2.1 ( W.C.) combined bath 2.8 1.2 2.1 and w.c Store 3 1.2 2.2 Garage 18 3 2.4 10. Light and (a) one or more openings, such as windows and ventilators, Ventilation opening directly to the external air or into an open Verandah. (b) such openings, excluding doors inclusive of frames, shall not be less than one-tenth of the floor area. In case of Kitchen such opening shall be increased by 25 percent. 11. Ventilation Shaft The size of ventilation shaft shall not be less than the values given below:- Height of building Size (sq.m) Min. one dimension 10m 1.2 0.9 m 12m 2.8 1.2 m 18m 4.0 1.5 m Serial Parameter Permissible Limits Num- Category Pre Nursery/ Primary School High/ Sr. Sec. ber Nursery/ Creche (Class 1 To 5) School/ College or Edu. Institute/ Universities PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2358 Height of building Size (sq.m) Min. one dimension 24m 5.4 1.8 m 30m 8.0 2.4 m Above 30m 9.0 3.0 m Notes:- (a) For buildings of height above 30 m, a mechanical ventilation system shall be installed besides the provision of minimum ventilation shaft. (b) For fully air conditioned the ventilation shaft need not be insisted upon, provided the air conditioning system works in an uninterrupted manner, also, provided there is an alternative source of power supply. (c) Mechanical ventilation in building shall be as per the provision of the National Building Code of India, 2016, as amended from time to time. 12. Interior courtyard Minimum area 9 sq.m for Light and Minimum width 2.4 m or 1/5 of the average height of the Ventilation building whichever is more. 13. Staircase requirement:- Minimum Width 1500 mm or as per occupants load whichever is more. Minimum Tread 300 mm Maximum Riser 150 mm Minimum Clear 2200mm Head Height 14. Minimum width 1500 mm for single loaded and 1800 mm for double loaded or of corridor or as per occupant load whichever is more. Passage 15. Lift and Ramp Lift is mandatory in buildings 15m or more in height and Requirement basement provided more than one level as per the provision of the National Building Code of India, 2016. Ramp is compulsory in educational building (upto high/ secondary school level) and shall go up to the highest floor. However, it Serial Parameter Permissible Limits Num- Category Pre Nursery/ Primary School High/ Sr. Sec. ber Nursery/ Creche (Class 1 To 5) School/ College or Edu. Institute/ Universities PUNJAB GOVT. GAZ., SEPTEMBER 10, 2021 (BHDR 19, 1943 SAKA) 2359 shall not be mandatory for higher level educational institute building. Ramp requirement for pedestrians, differently-abled, elderly and children: (a) Minimum width: (i) upto Plinth Level - 1800mm (ii) For Higher Floors–1500mm or as per the occupant load whichever is more (b) Slope: Not less than 1:12 16. Mumty Allowed upto 2.75 m, otherwise counted towards the height of the building as well as Floor Area Ratio. 17. Services in terrace Solar Photo Voltaic installation, Water tank, Rain water pipes with drainage, Water Tank, cooling towers for air conditioning plants, mumty, machine room and screening parapet to hide services or as per the provisions of the National Building Code of India, 2016. 18. Gate Maximum height shall not more than 1.83 m

Previous and next

All provisions of The Punjab Urban Planning and Development Building Rules, 2021

Questions people ask

Is rule 17 of the Punjab Urban Planning and Development Building Rules, 2021 still in force?

No repeal of the Punjab Urban Planning and Development Building Rules, 2021 is recorded.