Rule 52, Tamil Nadu Combined Development and Building Rules, 2019: Requirements of parts of buildings
Tamil Nadu Combined Development and Building Rules, 2019 - Rule 52
Text of rule 52
Requirements of parts of buildings
52. Requirements of parts of buildings.— (1) Plinth.— (a) Main buildings: The plinth or
any part of a building or out house shall be so located with respect to the surrounding
ground level that adequate drainage of the site is assured. The height of the plinth shall
be not less than 45 cm from the surrounding ground level. However in flood prone areas,
plinth shall be above the maximum flood level notified by the concerned authority.
(b) Interior court yards and covered parking areas shall be raised at least 15 cm
above the determining ground level and shall be satisfactorily drained.
(2) Walls .— (a) The outer walls of a building shall be constructed of bricks or stone or
other incombustible material.
(b) All walls of a building must be properly bonded.
(c) Damp-Proof
(i) Every wall and pier of the building except when built on materials such
as steel or reinforced cement concrete shall be provided with a damp-
proof course.
(ii) Damp-proof course shall be laid at a level not higher than the lowest part
of underside of the construction of the ground floor and shall extend to
the full width and extent of such walls or piers. It shall be at least two
centimeters thick. Where the damp-proof course is provided below the
plinth level, vertical damp-proof course shall be provided between the
floor and the inside of the plinth.
(3) Paving materials.— In the case of every building intended to be used for human
habitation, every part of each floor of such building, including every passage and
airy verandah therein, every lavatory, urinal, washing or bathing place included in
it, shall be laid or paved with stone or non-absorbent tiles laid in cement or other
durable material, impervious to moisture.
(4) Structural metal.— shall not be used for conducting electrical or service currents:
Provided that such metal may be used as part of a sufficient and properly earthed
apparatus for protection of the building against damage by lightening.
(5) Habitable rooms.— (a) Height: The height of all rooms for human habitation shall
not be less than 2.75m measured from the surface of the floor to the lowest point of
the ceiling bottom of slab. In the case of pitched roof, the average height of rooms
shall not be less than 2.75m. The minimum clear head room under a beam, folded
plates or eaves shall be 2.4m. In the case of air conditioned rooms, a height of not
less than 2.5m measured from the surface of the floor to the lowest point of air
conditioning duct or the false ceiling shall be provided.
64 TAMIL NADU GOVERNMENT GAZETTE EXTRAORDINARY
(b) Size: The area of habitable room shall not be less than 7.5sq.m with a
minimum width of 2.4m. Pooja room, or store room shall not be taken as a
habitable room]
(6) Kitchen.— (a) Height: The height of a kitchen measured from the surface of the
floor to the lowest point of the ceiling (bottom slab) shall not be less than 2.75m,
except for the portion to accommodate floor trap of the upper floor.
(b) Size: The area of a kitchen where separate dining area is provided shall be not
less than 5.0 sq.m. with a minimum width of 1.8m. where there is a separate
store, the area of the kitchen may be reduced to 4.5sq.m. A kitchen, which is
intended for use as a dining area also, shall have a floor area of not less than
7.5 sq.m. with a minimum width of 2.1m.
(c) Other requirements: Every room to be used as kitchen shall have:
(i) Unless separately provided in a pantry, means for the washing of kitchen
utensils which shall lead directly are through a sink to a grated and
trapped connection to the waste pipe;
(ii) an impermeable floor;
(iii) a flue, if found necessary; and
(iv) a window or ventilator or opening.
(7) Bathrooms and Water closets.— (a) Height: The height of a bathroom or water
closets measured from the surface of the floor to the lowest point in the ceiling
bottom of slab shall not be less than 2.1m.
(b) Size: The area of a bath room shall not be less than 1.4 sq.m. with a minimum
width of 1.0m. The floor area of water closet shall be 1.0 sq.m. with a
minimum width of 0.9m. If bath and water closet are combined, its floor area
shall not be less than 2.4sq.m. with a minimum width of 1.2m.
(c) Other requirements: Every bath room or water closet shall:
(i) be so situated that at least one of its walls shall open to external air;
(ii) not be directly over or under any room other than another water closet,
(iii) washing place, bath or terrace, unless it has a water-tight floor;
(iv) be enclosed by walls or partitions and the surface of every such wall or
partitions shall be finished with a smooth impervious material to a height
of not less than 1m above the floor of such a room;
(v) be provided with an impervious floor covering, sloping towards the drain
with a suitable grade and not towards varandah or any other room; and
have a window or ventilator, opening to a shaft or open space, of area not
less than 0.3 sq.m.
(vi) the door of the water closet or bath not to be directly opened to a kitchen
(8) Mezzanine Floor.— (a) Height - It shall have a minimum height of 2.2 m.
(b) Size- The minimum size of the mezzanine floor, if it is to be used as a living
room shall not be less than 9.5 sq.m.. The aggregate area of such mezzanine
floor in a building shall in no case exceed 1/2nd the plinth area of the
building.
TAMIL NADU GOVERNMENT GAZETTE EXTRAORDINARY 65
(c) Other Requirements - A mezzanine floor may be permitted over a room or a
compartment provided:
(i) it conform to the standard of living rooms as regards lighting and
ventilation in case the size of mezzanine floor is 9.5 sq.m. or more;
(ii) it is so constructed as not to interfere under any circumstances with
the ventilation of the space over and under it;
(iii) such mezzanine floor is not sub-divided into smaller compartments;
(iv) such mezzanine floor or any part of it shall not be used as a kitchen;
and
(v) in no case shall a mezzanine floor be closed so as to make it liable to be
converted into unventilated compartments.
(9) Store room.— Height: The height of a storeroom shall be not less than 2.2m.
Size: The size of a storeroom, where provided in a residential building, shall be
not less than 3sq.m.
(10) Garage.— Height - The height of a garage shall be not less than 2.4 m.
Size - The size of garages shall be as below:
a) Private Garage - 3.0m × 6.0m, minimum; and
b) Public Garage - Based on the number of vehicles parked by Equivalent Car
Unit .
(11) Basement.— (a) The basement shall not be used for residential purposes
(b) The basement shall have the following requirements:
(i) Every basement used for non-habitable purposes shall be in every part at least
2.4m in height from the floor to the underside of the roof slab or ceiling; for
habitable purposes, it shall conform to the standards prescribed for habitable
rooms above.
(ii) Adequate ventilation shall be provided for the basement. The ventilation
requirements shall be the same as required by the particular occupancy
according to National Building Code. Any deficiency may be met by providing
adequate mechanical ventilation in the form of blowers, exhaust fans, air
conditioning systems, etc.;
(iii) Adequate arrangements shall be made such that surface drainage does not
enter the basement;
(iv) The walls and floors of the basement shall be water-tight and be so designed
that the effects of the surrounding soil and moisture, if any, are taken into
account in design and adequate damp proofing treatment is given; and
(v) The access to the basement shall be separate from the main and alternative
staircase providing access and exit from higher floors. Where the staircase is
continuous in the case of building served by more than one staircase, the same
shall be of enclosed type serving as a fire separation from the basement floor
and higher floors.
(vi) The exit requirements in basements shall comply with the provisions of the
NBC Part 4 ‘Fire and Life Safety’
66 TAMIL NADU GOVERNMENT GAZETTE EXTRAORDINARY
(12) Chimneys.— The chimneys shall be built at least 0.9 m above flat roofs,
provided the top of the chimneys is not below the top of the adjacent parapet wall.
In the case of sloping roofs, the chimney top shall not be less than 0.6 m above
the ridge of the roof in which the chimney penetrates.
(13) Parapet.— Parapet walls and handrails provided on the edges of roof terraces,
balcony, verandah, etc. shall not be less than 1.2m and not be more than 1.5m in
height from the finished floor level.
(14) Roofs.— (a) The roof of a building shall be so designed and constructed as to
effectively drain water by means of sufficient rain-water pipes of adequate size
wherever required, so arranged, jointly and fixed as to ensure that the rain-water is
carried away from the building without causing dampness in any part of the walls,
roof or foundations of the building or an adjacent building.
(b) Rain-water pipes shall be affixed to the outside of the external walls of the
building or in recesses or chases cut or formed in such external walls or in
such other manner.
(c) Conservation of rain-water using suitable rainwater harvesting techniques
including by roof water collection shall be made.
(15) Mosquito-proof Water Tank.— Water storage tank shall be maintained in a perfect
mosquito-proof condition, by providing a properly fitting hinged cover, and every
tank more than 1.50mts. in height shall be provided with a permanently fixed iron
ladder to enable inspection by anti-malaria staff.
(16) Lighting and Ventilation.— Rooms shall have, for the admission of light and air,
one or more openings, such as windows and ventilators, opening directly to the
external air or into an open verandah.
(a) Notwithstanding the area of openings stated above, the minimum aggregate
area of such openings, excluding doors inclusive of frames, shall be not less
than one- eighth of the floor area;
Note:
(i) If a window is partly fixed, the openable area shall be counted
(ii) No portion of a room shall be assumed to be lighted, if it is more than
7.5m away from the opening assumed for lighting that portion.
(iii) The area of openings as given above shall be increased by 25% in the
case of a kitchen
(iv) in cases where the ventilation is derived through open to sky. the
dimensions of the open to sky need to be 1.5m x 2.5m. This will apply to
kitchens and store rooms but not to lavatories and bath rooms which
shall have windows or ventilators of not less than 0.5sq.m. abutting such
open space
(b) For requirements regarding lighting and ventilation for different uses and
occupancy reference shall be made to the NBC Part 8 ‘Building Services,
Section 1 Lighting and Ventilation’.
(17) Stairways Requirements.— (a) Minimum width of staircase shall be:
(i) (a) Ordinary Residential buildings…………. 0.75 m
(b) Other Residential buildings ……………. 0.90 m
TAMIL NADU GOVERNMENT GAZETTE EXTRAORDINARY 67
(ii) Assembly buildings like :
Auditoria, assembly halls….. ………………… 2.00 m
(iii) All other buildings………………………………. 1.50 m
(iv) Educational institutions………………………. 2.00 m
b) Minimum tread
The minimum width of tread without nosing shall be 250mm for residential
buildings. The minimum width of tread for other buildings shall be 300mm. In
case of spiral staircases, it shall have the above minimum tread width at the
outer end.
c) Maximum riser
The maximum height of riser shall be 190 mm for residential buildings and
150 mm for other buildings and these shall be limited to 15 per flight.
d) The minimum headroom in a passage under the landing of a staircase shall be
2.2m. The minimum clear headroom in any staircase shall be 2.2m.