51. Structural Safety.— (1) In the cases of Non High Rise buildings with height upto 12m.,
industrial or institutional buildings upto G+1 floors in height and with floor area both
existing and proposed not exceeding 300 sq.m. the provisions in this part of the rules
relating to structural design, submission of working drawings or structural drawings,
etc. shall not apply except that all such applications and plans for these developments
shall be signed by the owner or Registered Developer, and the Registered Engineer or
Architect who prepared the plan and further the Registered Engineer or Architect shall
certify that the structural design of the small development has been done as per the
latest Indian standard Specifications and the National Building Code.
(2) Structural design.— The structural design of foundations, elements of masonry,
timber, plain concrete, reinforced concrete, pre-stressed concrete and structural
steel shall conform to the provisions of part VI Structural Design Section – 1 Loads,
Section – 2 Foundation, Section – 3 Wood, Section – 4 Masonry, Section – 5
62 TAMIL NADU GOVERNMENT GAZETTE EXTRAORDINARY
Concrete and Section – 6 Steel of National Building Code of India, taking into
consideration the Indian Standards as given in the Annexure - XI
(3) Structural Design Basis Report [SDBR] .— Drawings and Documents to be
submitted for approval of appropriate authorities shall include SDBR. In compliance
of the design with the Indian Standard the Registered Structural Engineer on
Record shall submit a structural design basis report in Form 1 in Annexure - XIV.
(4) Review of Structural Design.—The competent authority for issue of Building
permit in case of Village Panchayats, if necessary, shall constitute a Structural
Design Review Panel (SDRP) consisting of senior SERs whose task will be to review
and certify the design prepared by SER for all High Rise buildings and in cases of
other developments whenever referred by the competent authority excluding for Non
High Rise buildings with height upto 12m.
(5) Certification Regarding Structural Safety in Design.— The Registered Structural
Engineer on Record (SER) shall give a certificate of structural safety of design as per
Proforma given in Form8 in Annexure - XIV at the time of completion and structural
inspection report as per proforma given in Form 9 at different stages of
construction.
(6) Constructional Safety.— (a) All construction except Non High Rise buildings with
height upto 12m. shall be carried out under supervision of the Registered
Construction Engineer on Record (CER)
(b) CER shall give a certificate of structural safety of construction while submitting the
progress report as per proforma given in Form 3 and 4 in Annexure - XIV at the
different stages of construction and at the time of completion as per proforma
given in Form 7 in Annexure - XIV.
(7) Quality Control and Inspection.— (a) All High rise building construction with
more than 18.30m. in height shall be carried out under quality inspection program
prepared and implemented under the the Registered Quality Auditor on Record
(QAR).
(b) The Registered Quality Auditor on Record (QAR) shall give a certificate of
quality control as per proforma given in Form10 in Annexure - XIV .
(c) Quality Inspection Programme to be carried on the site shall be worked out by
QAR in consultation with the owner, builder, CER.
(8) Protective Measures in Natural Hazard Prone Areas.— In natural hazard prone
areas, structures, buildings and installations, which cannot be avoided, such
constructions or developments should be properly safeguarded by taking protective
measures as recommended in Annexure - XII
(9) Maintenance of buildings in seismic Zone-III.— In case of High rise buildings and
buildings for public assembly older than fifty years, it shall be the duty of the owner
of a building, to get his building inspected by a Registered Structural Engineer (RSE)
within a year from the date of coming into force of these rules. The Structural
Inspection Report in Form 9 in Annexure - XIV shall be produced by the Owner to
the competent authority. If any action, for ensuring the structural safety and
stability of the building is to be taken, as recommended by SER, it shall be
completed within five years. For other buildings less than fifty years old, the owner
shall get his building inspected after the age of building has crossed fifty years. The
procedure shall be followed as per above rule.
(b) Seismic Strengthening or Retrofitting.—Prior to seismic strengtheningor
retrofitting of any existing structure, evaluation of the existing structure as
regards structural vulnerability in the specified windor seismic hazard zone
shall be carried out by a Registered Structural Engineer. If as per the
TAMIL NADU GOVERNMENT GAZETTE EXTRAORDINARY 63
evaluation of the Registered Structural Engineer the seismic resistance is
assessed to be less than the specified minimum seismic resistance as given in
the “note” below, action should be initiated to carry out the upgrading of the
seismic resistance of the building as per applicable standard guidelines.
Note:
(i) for masonry buildings reference is to be made to IS: 4326 and IS: 13935
and
(ii) for concrete buildings and structures reference to be made to IS code on
evaluation and seismic strengthening for retrofitting of RCC buildings
under preparation at present.