Rule 43, Tamil Nadu Combined Development and Building Rules, 2019: Provisions for differently abled, elderly and children
Tamil Nadu Combined Development and Building Rules, 2019 - Rule 43
Text of rule 43
Provisions for differently abled, elderly and children
43. Provisions for differently abled, elderly and children.— In order to provide barrier
free environment in the buildings and premises used by public the following should be
provided. These regulations shall be applicable to all buildings and facilities used by
the public such as educational, institutional, assembly, commercial, business,
48 TAMIL NADU GOVERNMENT GAZETTE EXTRAORDINARY
mercantile buildings and group housing constructed on plots having an area of more
than 2000 sq.m. It shall not apply to private residential buildings.
(a) Types of buildings to adopt barrier free guidelines
(i) Buildings to be designed for Ambulant Disabled People:
Higher Secondary School, Conference Hall, Dance Halls, Youth Centers, Youth
Clubs, Sport Centers, Sport Pavilions, Boat Club Houses, Ice Rinks,
Bowling Centers, Swimming Pools, Police Stations, Law Courts, Courts
Houses, Sport Stadiums, Theaters, Concert Halls, Cinemas, Auditoria, Small
Offices (the maximum plinth area 1400 sq.mt) Snack Bars, Cafes and
banqueting rooms (for capacity above 50 dinners).
Note:
(a) In sport stadiums provisions shall be made for non-ambulant spectators
(small wheel chair)
(b) @ 1:1000 up to 10,000 spectators and @ 1:2000 for spectators above
10,000.
(c) In Theaters, Concert Halls, Cinemas and Auditoria provisions shall be
made for non-ambulant spectators (Small Wheel Chairs) @ 1/250 up to
1000 spectators and 1/500 for spectators above 1000.
(ii) Buildings to be designed for Non-Ambulant Disabled People:
Schools for differently abled and other buildings such as Residential building,
Educational building, Institutional building, Assembly building, Business
building, Mercantile building, Industrial building, Storage building, Hazardous
building, Mixed Land use buildings, Wholesale Establishment and along with
Botanical Gardens, Religious Buildings, Elderly People Clubs, Village Halls, Day
Centers, Junior Training Centers, Post Offices, Banks, Dispensaries, Railway
Stations, Shops, Super Markets, and Departmental Stores.
Note:
Large wheel chair criteria shall be applicable on ground floors of the
following building, post offices, banks, dispensaries, railway station, shops,
supermarkets, and departmental stores.
(iii) Buildings to be designed for Non-Ambulant People (using small wheel
chairs)
Public lavatories in Tourist Sports, Clubs, Motels, Professional and
Scientific Institution, Museum, Art Galleries, Public Libraries, Laborites,
Universities, College for further Education, Teachers Training Colleges,
Technical College, Exhibition Halls Dentist Surgeries, Administrative
Department of the Hospitals, Service Stations, Car Parking,
Buildings Airports Terminals, Bus Terminals, Factories.
Employing differently-abled for sedentary works, Large Offices, with plinth area
abode 1400 sq.mt., Tax Offices, Passport Offices, Pension Offices, and Labour
Offices, Cafes, Banqueting Rooms and Snack Bars (For capacity above 100
dinners.
(b) Site development:
Level of the roads, access paths and parking areas shall be described in the plan
along with specification of the materials.
Access Path / Walk Way
Access path from plot entry and surface parking to building entrance shall be
minimum of 1800 mm wide having even surface without any steps. Slope, if any,
shall not have gradient greater than 5%. Selection of floor material shall be made
TAMIL NADU GOVERNMENT GAZETTE EXTRAORDINARY 49
suitably to attract or to guide visually impaired persons (limited to coloured floor
material whose colour and brightness is conspicuously different from that of
the surrounding floor material or the material that emits different sound to guide
visually impaired persons; hereinafter referred “o as "guiding floor material".
Finishes shall have a non- slip surface with a texture traversable by a wheel
chair. Kerbs wherever provided should blend to a common level.
(c) Parking:
For parking of vehicles of differently-abled people, the following provisions
shall apply:
(i) Surface parking for two car spaces shall be provided near entrance for the
physically differently-abled persons with maximum travel distance of 30m. from
building entrance.
(ii) The width of parking bay shall be minimum 3.6 meter.
(iii) The information stating that the space is reserved for wheel chair users
shall be conspicuously displayed.
(iv) Guiding floor materials shall be provided or a device, which guides visually
impaired persons with audible signals, or other devices, which serves the
same purpose, shall be provided.
(d) Building requirements
The specified facilities in buildings for persons shall be as follows:
(i) Approach to plinth level:
Every building should have at least one entrance accessible to the differently
abled and shall be indicated by proper signage. This entrance shall be
approached through a ramp together with the stepped entry.
(ii) Ramped Approach:
Ramp shall be finished with non-slip material to enter the building. Minimum
width of ramp shall be 1800mm with maximum gradient 1:12. Length of ramp
shall not exceed 9.0 meter having 800mm high hand rail on both sides
extending 300mm beyond top and bottom of the ramp. Minimum gap from the
adjacent wall to the hand rail shall be 50mm.
(iii) Stepped Approach:
For stepped approach size of tread shall not be less than 300mm and maximum
riser shall be 150mm. Provision of 800mm high hand rail on both sides of the
stepped approach similar to the ramped approach.
(iv) Exit/Entrance Door:
Minimum & clear opening of the entrance door shall be 900mm and it shall not
be provided with a step that obstructs the passage of a wheel chair user.
Threshold shall not be raised more than 12mm.
(v) Entrance Landing:
Entrance landing shall be provided adjacent to ramp with the minimum
dimension 1800mm x 2000mm. The entrance landing that adjoins the top end
of a slope shall be provided with floor materials to attract the attention of
visually impaired person's (limited to coloured floor material whose colour and
brightness is conspicuously different from that of the surrounding floor material
50 TAMIL NADU GOVERNMENT GAZETTE EXTRAORDINARY
or the material that emits different sound to guide visually impaired persons.
Finishes shall have a non-slip surface with a texture traversable by a wheel
chair. Kerbs wherever provided should blend to a common level.
(vi) Corridor connecting the entrance/ exit for the differently abled:
The corridor connecting the entrance / exit for differently abled leading directly
outdoors to a place where information concerning the overall use of the
specified building can be provided to visually impaired persons either by a
person or by signs, shall be provided as follows:
(a) Guiding floor materials' shall be provided or device that
emits sound to guide visually impaired persons.
(b) The minimum width shall be 1500mm.
(c) In case there is a difference of level, slope ways shall be
provided with a slope of 1:12.
(d) Handrails shall be provided for ramps/slope ways.
(vii) Stair-ways:
One of the stair–ways - near the entrance / exit for the differently abled shall
have the following provisions:
(a) The minimum width shall be 1350 mm.
(b) Height of the riser shall not be more than 150 mm and width of the
tread 300mm.
(c) The steps shall not have abrupt (square) nosing.
(d) Maximum number of risers on a flight shall be limited to 12.
(e) Handrails shall be provided on both sides and shall extend 300 mm on
the top and bottom of each flight of steps.
(viii) Lifts:
Wherever lift is required as per bye-laws, provision of at least one lift shall be
made for the wheel chair user with the following cage dimensions of lift
recommended for passenger lift of 13 person’s capacity of NBC 2005, BIS.
Section 4.9.3 Table no1- Desirable Lift size
Clear internal width 1100 mm Clear internal depth 2000 mm Entrance door
width 900 mm
(a) A hand rail not less than 600mm long at 1000mm above floor level shall
be fixed adjacent to the control panel.
(b) The lift lobby shall be of an inside measurement of 1800 mm x 2000 mm
or more.
(c) The time of an automatically closing door should be minimum 5
seconds and the closing speed should not exceed 0.25 m/ sec.
(d) The interior of the cage shall be provided with a device that audibly
indicates the floor, the cage has reached indicates that the door of
the cage of entrance or exit is either open or closed.
(e) Graphic or Braille signage, as per the Harmonized Guidelines, shall
be provided in the lift lobby.
TAMIL NADU GOVERNMENT GAZETTE EXTRAORDINARY 51
(ix) Toilets:
One special W.C. in a set of toilets shall be provided for the use of differently
abled with essential provision of washbasin near the entrance for the differently
abled.
(a) The minimum size shall be 1500 mm x 1750 mm.
(b) Minimum clear opening of the door shall be 900mm and the door shall
swing out.
(c) Suitable arrangement of vertical/horizontal handrails with 50mm
clearance from wall shall be made in the toilet.
(d) The W.C. seat shall be 500mm from the floor.
(x) Proper signage:
(a) Appropriate identification of specific facilities within a building for the
differently abled persons should be done with proper signals.
(b) Visually impaired persons make use of other senses such as hearing and
touch to compensate for the lack of vision, whereas visual signals benefit
those with hearing disabilities. Signs should be designed and located so
that they are easily legible by using suitable letter size (not less than 20
mm high).
(c) For visually impaired persons, information board in brail should be
installed on the wall at a suitable height and it should be possible to
approach them closely.
(d) To ensure safe walking, there should not be any protruding sign
which creates obstruction in walking.
(e) Public Address System may also be provided in busy public areas.
(f) The symbols/information should be in contrasting colour and properly
illuminated because people with limited vision may be able to
differentiate amongst primary colours.
(g) International Symbol Mark for wheel chair be installed in a lift, toilet,
staircase, parking areas, etc., that have been provided for the differently
abled.
Previous and next
All provisions of Tamil Nadu Combined Development and Building Rules, 2019
Questions people ask
Is rule 43 of Tamil Nadu Combined Development and Building Rules, 2019 still in force?
No repeal of Tamil Nadu Combined Development and Building Rules, 2019 is recorded.