Form 1, Tamil Nadu Combined Development and Building Rules, 2019: Form 1

Tamil Nadu Combined Development and Building Rules, 2019 - Form 1

Text of form 1

Form 1

Form 1 Structural Design Basis Report (1) This report to accompany the application for Building Developments Part1 General Data S.No. Description Information Notes 1. Site Address ……………………….. 2 Name of Owner 3 Name of Registered Developer along with the Registration Number 4 Name of Registered Architect/Engineer along with the Registration Number 5 Name of Registered Structural engineer along with the Registration Number 6 Use of the building 7 Number of stories above ground level (including storeys to be added later, if any) 8 Number of basements below ground level 9 Type of structure Load bearing walls R.C.C. frame R.C.C. frame and Shear Walls Steel frame 10 Soil data Type of soil Design safe bearing capacity IS:1893 C1.6.3.5.2 IS: 1904 IS: 1892 IS: 2131 IS: 2720 11 Dead loads (unit weight adopted)  Earth  Water  Brick masonry  Plain cement concrete  Reinforced cement concrete  Floor finish  Other fill materials IS: 875 Part 1 12 Imposed (live) loads IS: 875 Part 2 Floor loads Roof loads 13 Cyclone/Wind  Speed  Design pressure intensity IS: 875 Part 3 TAMIL NADU GOVERNMENT GAZETTE EXTRAORDINARY 127 14 Seismic zone IS: 1893 (2002) 15 Importance factor IS:1893(2002) Table 6 16 Seismic zone factor (Z) IS:1893 Table 2 17 Response reduction factor IS:1893 Table 7 18 Fundamental natural period – approx. IS:1893 C1.7.6 19 Design horizontal acceleration spectrum value (Ah) IS: 1893 C1.6.4.2 20 ♥ Expansion/Separation Joints 21 Building is regular/irregular IS 1893  Enclose detailed drawings drawn to scale for each floor  In case terrace garden is provided, indicate additional fill load and live load along with the detailed drawings drawn to scale Part 2 Load bearing masonry buildings Sl.No. Description Information Notes 1 Building category IS: 4326 C1.7 Read with IS:1893 Zone Bldg. II III IV V Ordinary B C D E Important C D E E 2 Basement Provided 3 Number of floors including Ground Floor (all floors including stepped floors in hill slopes) 4 Type of wall masonry 5 Type and mix of Mortar IS: 4326 C1.8.1.2 6 Re: size and position of openings (See note No.[i])  Minimum distance (b5)  Ratio (b1+b2+b3)/11 or (b6+b7)/12  Minimum pier width between consequent opening (b4)  Vertical distance (h3)  Ratio of wall height to thickness 4 Ratio of wall length between cross wall to thickness IS: 4326 Table 4, Fig.7 7 Horizontal seismic band  at plinth level  at window sill level  at lintel level  at ceiling level P IP NA � � � � � � � � � � � � (see note No.2) IS:4326 C1 8.4.6 IS: 4326 C1 8.3 IS: 4326 C1 8.4.2 IS: 4326 C1 8.4.3 IS: 4326 C1 8.4.3 128 TAMIL NADU GOVERNMENT GAZETTE EXTRAORDINARY  at eave level of sloping roof  at top of gable walls  at top of ridge walls � � � � � � � � � IS: 4326 C1 8.4.3 IS: 4326 C1 8.4.4 8 Vertical reinforcing bar at corners and T junction of walls at jambs of doors and window openings � � � � � � IS: 4326 C1 8.4.8. IS: 4326 C1 8.4.9 9 Integration of prefab roofing/flooring elements through reinforced concrete screed. � � � IS:4326 C1 9.1.4 10 Horizontal bracings in pitched truss in horizontal plane at the level of ties in the slopes of pitched roofs � � � � � � Notes: (i) Information in Item 6 should be given on separate A4 sheets for all walls with large number of openings (ii) IP indicated “Information Provided” IP indicates “Information to be provided” NA indicates “Not Applicable” Tick mark one box Part 3 Reinforced concrete framed buildings Sl. No. Description Information Notes 1 Type of building  Regular frames  Regular frames with Shear Walls  Irregular frames  Irregular frames with Shear Walls  Soft storey IS: 1893 C1 7.1 2 Number of basements 3 Number of floors including ground floor 4 Horizontal floor system  Beams and slabs  Waffles  Ribbed floor  Flat slab with drops  Flat plate without drops 5 Soil data  Type of soil  Recommended type of foundation -Independent footings -Raft -Piles  Recommended bearing capacity of soil IS: 1498 TAMIL NADU GOVERNMENT GAZETTE EXTRAORDINARY 129  Recommended type, length, diameter and load capacity of piles  Depth of water table  Chemical analysis of ground water  Chemical analysis of soil 6 Foundations Depth below ground level Type Independent Interconnected Raft Piles 7 System of interconnecting foundations Plinth beams Foundation beams IS: 1893 C1 7.12.1 8 Grades if concrete used in different parts of building 9 Method of analysis used 10 Computer software used 11 Torsion included IS: 1893 C1 7.9 12 Base shear a. Based on approximate fundamental period b. Based on dynamic analysis c. Ratio of a/b IS: 1893 Cl. 7.5.3 13 Distribution of seismic forces along the height of the building. IS:1893 Cl.7.7 (Provide sketch) 14 The Column of soft ground storey specially designed. IS: 1893 Cl.7.10 15 Clear minimum cover provided in  Footing  Column  Beams  Slabs  Walls IS: 456 Cl. 26.4 16 Ductile detailing of RC frame  Type of reinforcement used  Minimum dimension of beams  Minimum dimension of columns  Minimum percentage of reinforcement of beams at any cross section  Maximum percentage of reinforcement at any section of beam  Spacing of transverse reinforcement in 2-d length of beams near the ends  Ratio of capacity of beams in shear to capacity of beams in flexure  Maximum percentage of reinforcement in column IS: 456 Cl. 5.6 IS: 13920 Cl.6.1 IS: 13920 Cl.7.1.2 IS: 456 Cl.26.5.1(a) IS: 13920 Cl.6.2.1 IS: 456 Cl.26.5.1.1(b) IS: 13920 Cl.6.2.2 IS: 13920 Cl.6.3.5 IS: 456 Cl.26.5.3.1 IS: 13920 Cl. 7.4 130 TAMIL NADU GOVERNMENT GAZETTE EXTRAORDINARY  Confining stirrups near ends of columns and in beam-column joints Diameter Spacing  Ratio of shear capacity of columns to maximum seismic shear in the storey. 17 Does the features require clearance by SDRP Example: High rise building Prefab building Building in hazard prone areas Foundation i. In case raft foundation has been adopted, indicate K value used for analysis of the raft. ii. Incase pile foundations have been used, give full particulars of the piles, type, dia, length, capacity iii. In case of high water table, indicate system of countering water pressure, and indicate the existing water table, and that assumed to design foundations. Idealization for Earthquake analysis i. In case of composite system of shear walls and rigid frames, give distribution of base shear in the two systems on the basis of analysis, and that used for design of each system ii. Indicate the idealization of frames and shear walls adopted in the analysis with the help of sketches. iii. Submit framing plans of each floor iv. In case of basements, indicate the system used to contain earth pressures. Part 4 Buildings in structural steel 1 Adopted method of design o Simple o Semi-rigid o Rigid IS:800 Cl 3.4.4 IS:800 Cl.3.4.5 IS:800 Cl.3.5.6 2 Design based on o Elastic analysis o Plastic analysis IS: 800 Section-9 SP;6 (6) 3 Floor construction o Composite o Non composite o Boarded 4 Roof construction o Composite o Non composite o Metal o Any other 5 Horizontal force resisting system adopted Frames Braced frames Frames & shear walls Note: Seismic force As per IS:1893 Would depend on system 6 Slenderness ratios maintained Members defined in Table 3.1, IS:800 IS 800; Cl.3.7 7 Member deflection Beams, Rafters IS:800 Cl.3.13 TAMIL NADU GOVERNMENT GAZETTE EXTRAORDINARY 131 limited to Crane Girders, Purlins Top of columns 8 Structural members o Encased in concrete Not encased IS: 800 Section-10 9 Proposed material o General weld-able o High strength o Cold formed o Tubular IS: 2062 IS: 8500 IS: 801, 811 IS: 806 10. Minimum metal thickness Specified for corrosion protection o Hot rolled sections o Cold formed sections o Tubes IS: 800, Cl.3.8 Cl.3.8.1 to Cl.3.8.4 Cl.3.8.5 11 Structural connections o Rivets o CT Bolts o S H F G Bolts o Black Bolts o Welding field Shop (Specify welding type proposed) Composite IS: 800, Section-8 IS: 1929, 2155, 1149 IS 6639, 1367 IS 3757, 4000 IS: 1363, 1367 IS: 816, 814,1395, 7280, 3613, 6419, 6560, 813, 9595 12 Minimum Fire rating proposed, with method o Rating……………hour s o Method proposed. -In tumescent painting -Spraying -Quilting -Fire retardant boarding IS: 1641, 1642, 1643 Part-5 Any special weakness in the building making it vulnerable for stability related failure and the precaution to be taken during execution/completion and finishing to be indicated. Part-6 Recommendations of structural Engineer with respect to special requirements needed with respect to structural safety and stability to be taken note of by competent authority feature like incorporation of swimming pool, heavy load on roof ,prefabricated structure or any other hazardous features should be included. 132 TAMIL NADU GOVERNMENT GAZETTE EXTRAORDINARY

Previous and next

All provisions of Tamil Nadu Combined Development and Building Rules, 2019

Questions people ask

Is form 1 of Tamil Nadu Combined Development and Building Rules, 2019 still in force?

No repeal of Tamil Nadu Combined Development and Building Rules, 2019 is recorded.