Rule 97, TRIPURA BUILDING RULES — 2017: Open spaces for building
TRIPURA BUILDING RULES — 2017 - Rule 97
Text of rule 97
Open spaces for building
97. Open spaces for building.-
(1) Generally-
(a) every room intended for human habitation shall abut an interior or exterior open
space or an open verandah open to such interior or exterior open space. Open
Page 65
spaces shall be areas forming integral parts of the plot at ground level and shall be
open to sky without any projection or overhang excepting cornices, chajja or
weather-shades of not more than 0.50 meter width;
(b) every building shall have exterior open sprees comprising front open space, and
side open spaces. The minimum width prescribed for front open space, rear open
space and side spaces shall be provided along the entire front, rear and side faces of
the building respectively. For this purpose the front of the building shall be that face
of the building which faces the means of access of the building and the rear of the
building is that face of the building which is farthest from the means of access. These
provisions shall also be applicable to each individual building separately when a plot
contains more then one building. In the case of a corner plot located at the crossing
of more than one street or passage, the rear of the building shall be deemed to be
that face of the building, which is farthest from the widest of all such streets and/or
passages;
(c) open spaces prescribing to one site cannot be taken for another site. No building
shall at any time be erected on any open space prescribed in these rules for a
building and from part of the site thereof, nor shall such open space be taken into
account in determining the area of any open space required under these rules for
any other building.
(d) If the front open space is 3.00 meters or more in width a Gate Gomti for security
purpose may be allowed in the said open space. The covered area of such Gomti
shall not in any case exceed 3.00 sq. m. and the height of such Gomti shall not
exceed 3.00 meters. The covered area of the Gate Gomti shall not be included in
calculation of ground coverage.
(2) The minimum front, rear and side open spaces shall be provided along the entire
faces /sites of the building as given in the table below:
Minimum width of open space in meters Front Rear Side
Residential and Educational uses 1.5 m. 1.5 m. 1.5 m.
Commercial, Public and other uses 2.5 m. 2.5 m. 2.5 m.
Provided that the minimum clearance, on all the sides between a building
wall and the toe of a retaining or other protective wall shall be 1.50 meters,
except on the side where the septic tank shall be installed, in which case, the
minimum clear distance of 2.1 meters shall be provided:
provided further that for mixed use buildings, the minimum front open
space shall be the one applicable for that particular occupancy which gives the
provision of the minimum front open space in these rules, provided that for a
building more than 11.00 meters in height the Minimum open spaces provided in
sub-rule(2) above shall be increased by 0.3 meter in all cases.
(3) Notwithstanding anything contained elsewhere in this rule in the case of a
building with a septic tank, a side open space of 2.1 meters shall be provided on any one
side of the building for the provision of the said septic tank.
(4) In the case of a building more than 25.0 meters in depth, a passage of width not
less than 3.5 meters shall be provided along the entire depth of the building.
(5) For plots of size not more than 65(sixty five) sq. meters minimum side space of
0.90 meter may be allowed on each side provided the building height does not exceed
6.5 meters -
(a) notwithstanding anything contained in this rule, the minimum distance across
the side open space from every new building to an existing building with a door
or window opening shall be 1.80 meters;
(b) notwithstanding anything contained in this rule the minimum width of side open
space for an industrial or storage or mercantile (wholesale) building shall be
Page 66
(6)
98.
3.50 meters;
(c) in the case of a building more than 24.00 meters in depth on a plot abutting any
street a passage along the side depth of the building shall be provided and the
minimum width of such passage shall be 4.0 meters.
The interior open space shall be as follows: -
(a) For inner courtyard -
in case the whole of 1(one) side or part of at least 2(two) sides of every
room excepting bath, water closets and store-room is not abutting either
the front, rear or side open spaces, it shall abut an inner courtyard whose
minimum width shall be 30% of the height of the building or 3.00 meters
whichever is more.
(b) for ventilation shaft, that is to say -
for ventilating water closet bath room and kitchen such water closet or
bath room or kitchen if not opening to front side, rear or interior open
space, shall open on to a ventilation shaft, the size of which shall not be
less than the values given below :-
Height of building Minimum Area of ventilation
(meters) shaft Sq. Mts.
up to 11.00 1050 1.00
Above 11.00 but not more than 3.00
12.50 1'20
Note: No chajja shall be allowed in the ventilation shaft unless the width of shaft
is 2.40 meters or more.
( c) the minimum width shall not be less than 20% of the height of the building
or 2.50 meters, which ever is more.
(7) The service rooms shall have access by means of 2(two) passages of
staircases, providing access and exit from higher and lower level floors, the width
of which shall not be less than 1.2 meters and the slope shall not be steeper than
one 1:1 and so located that the travel distance on any floor up to any such access
or exit is not more than 15.0 meters.
(8) Mezzanines are to be used strictly for purposes other than habitation or
kitchens and eating places and may be provided between any 2(two) floor shall be
permitted with a minimum clear height at every part of at least 2.0 meters
measured from the floor to the lower most point on the underside of the roof, slab,
beam or false ceiling. The area of such mezzanines shall be included in floor area
in all calculations.
Access, circulation and parking. -
(1) Every plot shall abut a means of access which may be a public street or
private street or passage, the minimum width of which shall be as specified in this
rule.
(2) Any building which in full or part is put to assembly occupancy for the
purpose of theatre, motion picture house, city hall, skating-rink, auditorium,
exhibition hall or for similar other purposes shall not be allowed on a plot located
within 50 meters of the junction of 2(two) streets, the width of each of which shall
be a minimum of 8.0 meters.
(3) Every building on a plot having more than one building shall abut an internal
Page 67
99.
road connecting the means of access of the plot and such roads shall conform to
the requirements of internal roads specified in rule 52(1).
Number of car parking Spaces as per Covered Area of plot and Use Group
Residential and Educational uses 1 Car Space per 300 sq. meters.
Commercial, Public and other uses 1 Car Space per 200 sq. meters.
In case of a plot having more than one building or use, parking requirements
shall be calculated according to the proportionate floor area of each building or use
group, as the case may be.
(4) For plots abutting non-vehicular means of access less than 3.0 meters in width,
car parking space need not be provided within the plot area but space with vehicular
access has to be identified and owned by applicant for the required parking /garage
space, as per this rule.
(5) The parking space for each vehicle shall be accessible from the means of
access, either directly or through a driveway or internal circulation, aisle, the width of
which shall not be less than 3.5 meters for cars and 5.0 meters for trucks and the
gradient of which shall not be more than 1:6.
(6) The minimum size of a car parking space shall be 2.50 meters x 5.00 meters and
that for a truck or bus parking space shall be 3.75 metre x 10.00 meters. These spaces
do not include the area of circulation, internal roads, aisles and driveways, and
standards for those shall be guided by provisions in the National Building Code.
(7) No garage for car shall be less than 2.5 meters x 5.00 meters (clear size) with a
minimum head room of 2.0 meters and no garage for truck shall be less than 3.75
meters x 10.00 meters (clear size) with a minimum head room of 3.50 meters.
(8) (a) An internal road must be so constructed as to have a slope inwards/ towards
the hillside. Such slope must be not less than the gradient of the road;
(b) where required, the inner and outer edges of an internal road must be
protected by protective walls of such number and placed in such positions as
the ULB may direct and constructed in accordance with the specifications in
this rule.
Drainage measures. -
(1) (a) An open drain must be provided on the inner side of an internal road
constructed in accordance with the specifications in rule 98.
(b) an effective slope and drainage system shall be maintained at all times on the
developed ground after slope cutting or filling, during and after development as per this
rules on any side;
(c) the drainage system shall efficiently collect and carry away from the site, the
water collected within the premises or the building complex or from the hillside above, fix
suitable disposal as quickly an possible to water courses such) as main drains or natural
streams/jhoras without stagnation, avoiding any possibility or erosion, slope failure,
damage to the building or other property in the vicinity.
(2) (a) proper slops not less than 1 : 60 shall be maintained all around a building for
quick drainage of the entire plot as provided in Rules 90(1) (d) and 98.
The possibilities of erosion or ground failure through ingress and percolation of
water into soft ground or through joints and fissures in the soil crust shall be prevented by
suitable surface protection measures such as surface grouting, stone pitching, planting of
small plant and grass, so as to protect and make the surface impervious in accordance
with the provisions of the BIS Code, specially the minimum distance from provision
required to be maintained for planting trees;
(b) the flow of water, particularly on the upper side of the building, shall be
diverted away from the foundations through suitable lined or unlined drains;
Page 68
100.
(c ) drains for sullage/rain water must be constructed with round or half-round
tiles embedded in concrete, or with U-shaped stone masonry set in lime mortar and
plastered over the inner surface with Portland cement or with U-shaped stone concrete
and the sectional area of every drain shall be subject to the approval of the ULB.
(d) drains for surface water only may be constructed either of dry rubble
masonry or of any other material approved by the ULB and may be either rectangular or
U-shaped in section. Such drains shall not be connected with any drain carrying sullage
water or sewage;
(e) except with the written permission of the ULB no covered drain shall be
constructed and no existing open drain shall be covered in;
(f) no building shall be placed cover any drain;
(Q) where a small drain is crossed by a private road, a removable,
R.C.C. slab cover or wooden or iron grating, if the ULB so direct, must be laid
over the drain, instead of covered culvert;
(h) drains must discharge into the nearest water channel or public drain,
unless in any case the ULB othenivise direct, The outfall of a drain into a water channel
or public drain must be protected and guided in such manner as ULB may direct. Where
the drain of a private road joins the drain of a public road, the former drain must be so
directed or so protected by strike boards as to minimize the risk of damage to the public
drain or road.
Filters may also be provided where necessary;
(i) every building must be constructed so as not to project over, or admit of
water from the roof falling upon or damaging, any open space, road or passage it abuts,
whether public or private;
(j) every building shall have rain water gutters and pipes connected to a
drain, along the periphery of a building;
( k) a masonry drain must be placed round the periphery of every building or
block of buildings, sufficient in section and slope to the satisfaction of the ULB for the
effectual of the building and placed as to admit of the drainage being led into some drain
at the time existing or projected;
(l) the surrounding round adjacent to the building must be sloped from all
sides towards the perimeter drain and an impervious apron, not less than 0.75 m. wide
shall be provided all around the building to prevent the entry of water into the
foundations.
(3) (a) Septic tank and soak pits shall also be so located so as to be easily
accessible from the means of access to the plot.
(b) Soak pits shall be constructed on the side of buildings as far as possible,
at right angles to the slope of the land and as far as possible from the building
foundations. There shall be a minimum clearance of 2.1 meters between the foundation
and the soak pit to minimize the chances of dampness and slope failures due to
seepage from the soak pit.
(4)(a) A private bridge must be constructed as and where necessary to the satisfaction
of the ULB so as to leave sufficient watenNay to pass the maximum discharge of the
channel spanned by the bridge.
(b) The invert of the channel under a private bridge must, as far as
practicable, be laid to the same slope as that of the channel.
(c) When a pocket for the deposit of debris is cut in the hillside above a private
bridge, it must be lined with masonry walls unless, if constructed on solid rock.
Protective work in hills. -
(1) The cutting of slopes in the creation of steps and terraces for development
work shall be carried out while ensuring the stability of excavations to provide for the
Page 69
safety of the buildings located and constructed thereon in accordance with the
provisions in the BIS Codes.
(2) Local ground conditions shall be taken into account in the determination of the
appropriate precautionary work and protection walls such as revetments, retaining
walls, toe walls and breast walls as well as the specifications of the latest relevant
codes of practice of the Bureau of Indian Standards including :-
IS 14243 - part I & ll: Selection and development of site for building in hill areas
guidelines.
(2) The maximum height of cutting for development work as per soil strata shall be as given
below:
Lose soil or boulders with soil matrix 4.0 m
Compact soil or boulders with soil matrix overlaying loose, soft, fractured of firm 6.0 m
hard rock strata which remains vertical in 4 m high cutting when dry
Hard stable rock with or without compact soil or boulder with soil matrix up to 2 m 8.0 m
thick
Cutting of slopes over a height of 6.0 meters shall not be ordinarily permitted,
excepting with the special approval of the ULB.
(4)(i) The foundation of every protection wall must be taken down to original and firm
soil or rock, have a bed line cut at right angles with the face of the wall and a slope of 3:
1 towards the hillside;
(ii)(a) where a protection wall does not exceed 6.0 meters in height and is not
surcharged the mean of thickness of the revetment of wall above the footings shall not
be less than one-third of the vertical height of the revetment of wall, measured from the
top of the footings,
(b) where a protection wall does not exceed 6.0 meters in height and is
surcharged, the height assumed, for the determination of mean thickness of the
revetment or wall above the footings, shall be one and a half times the actual vertical
height :
Provided that the width at the top shall in no case be less than 0.5 meters and
shall not in any case exceed 1.0 meter,
(c) no structure shall be allowed to be raised from the top of the retaining /
protective walls.
(iii)(a) a protective wall may be of dry rubble masonry, or cement masonry as
per the directions of the ULB.
(b) dry stone masonry protection walls shall include cement masonry bands,
in 1 : 4 cement sand mortar 0.4 to 0.6 meter thick, at top
and bottom and vertically at 3.0 to 5.0 meters spacing,
(c) no stone used shall be of greater height than its length or breath, all
stones used must be laid on their natural beds, and must be arranged so as to break
joint as far as may be possible,
(d) every protection wall must be built up solid to full section and sprawls or
chips shall not be used for filling the courses unless their use is unavoidable;
(iv) one though bonding stone or line of bonding stones must be inserted at intervals
at 1.50 meters in each course, and at points intermediate between the corresponding
bonding stones of the course show :
any of the bonding stones, which do not extend right through the wall, must
overlap each other for one-third of their length.
(v)(a) special investigations and analysis shall be carried out to determine the details
of protection works in the case of R.C.C. retaining walls or protection walls on steep cut
slopes greater than 6.0 meters in height, or in case of fine soils like silt, clay or shales,
(b) in all such cases, detailed designs must be submitted to the Local Body and the
Page 70
101.
sections must be such as the ULB may approve,
(c) protection walls of height more than 6.00 meters and successive retaining walls,
shall only be permitted when there is hard stable rock behind and below the toe of the
said wall, as permissible under relevant BIS codes of practice;
(vi) the height of cutting for any step of a stepped building shall not be more than 4 m
and successive protection walls shall only be permitted when there is hard stable rock
behind and below the toe of every such walls;
(vii)(a) weep-holes shall be provided in breast walls and retaining walls equipped with
graded filter for proper drainage at intervals of 1.2 meters horizontally and 1.2 meters
vertically, in staggered manner and beginning from 0.20 meter above ground level.
(b) water along the base of a breast wall and retaining wall shall be drained
out by means of a suitable lined drain forming an integral part of the drainage system as
specified in Rule
(viii) when, a slope is determined to be vulnerable to a debris slide in pursuance of
any requisition or direction made or given by the ULB, the angle of a slope shall be
reduced to an angle of not more then 30° to the horizontal plane through trimming or
cutting to make the slopes stable along with minor protection both for soil and building
work.
Any barren surfaces above a cut slope shall be planted with selected varieties of
light but deep rooted bushes, shrubs and grass to cheek soil erosion and improve the
stability of the slope, in pursuance of any requisition or direction made or given by the
ULB.
Special Conditions.-
(1)(a). Additions to existing buildings shall only be permitted in the case of
structurally sound structures with a record of the complete details pertaining to the soil
stability materials and system of construction.
(b) the total floor area, height and ground coverage after addition to an
existing building shall not exceed the provisions of maximum permissible floor area,
height and open space as per the criteria specified in this rule and other relevant rules,
while the additions to an existing building shall further conform to the provisions for front,
rear and side setback as specified in these rules.
(2) In the case of multiple buildings in a plot, open space shall be set aside as
specified in for the purpose of public and community activity, in addition to the provisions
for open space and for providing the means of access as specified in this rule.
(3) Every building erected or re-erected, must have such structural and architectural
features as to prevent the building being in the opinion of the ULB unsightly or unsuitable
to its surroundings.
Furthermore, if the roof or walls of any building is, in the opinion of Local Body is
in an unsightly condition they may, by written order direct the owner to repair, paint or
colour-wash such part of the building as they may direct within the period specified in the
order.
(4) The foundations of all buildings, parts must rest on solid ground or rock and have
width and depth suitably designed, according to the distribution of the soil and hard rock
strata in different parts of the foundation, and have dimensions worked out as per the
permissible safe bearing capacity and other consideration in accordance with relevant
Codes of practice of BIS. The depth below the ground level shall not be less than 2.00
meters in the case of R.C.C. column footings and 1:2 meters in the case of all
foundations.
(5) Every building or part thereof shall have continuous foundation walls, extending
below ground level as specified. All openings in such walls or in floors, walls, windows
and drains and all junctions between building parts shall be tightly closed or effectively
secured with pest proof screening materials as approved by the ULB.
Page 71
(6) The party-walls of a masonry or framed building or the end wall of a Ferro-
concrete building must be built of stone or brick bedded in lime or cement mortar for their
full height and if the ULB so direct, must be carried up of a thickness of not less than
0.25 meter, above the roof, flat or gutter to such a height as will give a distance of at
least 0.5 meters measured at right angles to the slope of the roof above the highest part
of the roof flat or gutter.
(7)(a)lndividual columns of all R.C.C. framed building, in the case of stepped
foundations, shall be interconnected in 2(two) directions, generally at right
angles, by R.C.C. beams at the footing level, designed in accordance with the
latest edition of BIS Codes of practice;
(b) individual columns of all R.C.C. framed buildings as well as all external and
internal walls of a load bearing structure, shall be interconnected in 2(two) directions
generally at right angles, by R.C.C. beams at plinth level, adequately designed in
accordance with BIS Codes of practice;
(c)there shall be adequately designed R.C.C. lintel bands in all external and internal
brick and stone masonry walls at vertical intervals not more than 0.9 meter. These shall
be continuous and connected to each other at the same level in the case of all load
bearing walls and tied to the columns in case of R.C.C. framed structure.
(8) No building shall be altered so as to reduce the number, width or location of
exist to less than what is required under the criteria specified in this rules.
(9) If any car parking space is required to be provided under the criteria specified in
this rules and no such car parking space can be provided in such existing building, the
floor area allowable under the provisions of these rules shall be reduced by the area
required for such car parking spaces which cannot be provided for in the said building.
(10) No building shall be erected or re—erected in any locality if the ULB at a
meeting, records in writing that the proposed construction, either by reason of the nature
of its construction and location or by reason of the uses to which it is intended to be put,
is likely to affect in any substantial degree prejudicially any existing building, in the
locality by reducing its market value or by diminishing any advantage it enjoys on
account of its situation or othenNise.
(11) The ULB may decide the widths of buffer zone upslope and down slope of
National Highways and State Highways where no new construction or addition/alteration
to any existing structures or change of use will be allowed.
(12) The minimum widths for corridors within the building shall be as follows:
Residential tenement (internal) 0.9 meter
Mercantile, Business and Assembly buildings 2.0 meters
Access to shop in mercantile buildings
(shops on one side only)
(shops on one side only) 2.0 meters
3.0 meters
The width of all other corridors and those connecting vertical exist to individual units,
shall not be less than the width of the corresponding staircases as specified in the
rules.
Page 72
102.
PART XI
Heritage Building
Preserva_tion M conserva_tion of Heritage Buildings.-
(1) Every owner or occupier of any heritage building declared as such by the ULB
shall maintain, preserve and conserve it and shall not change its use in contravention of
the provisions of these rules or the regulations made there under for its maintenance,
preservation or conservation.
Explanation |.- The word "maintain”, with its grammatical variations and cognate
expressions, shall include fencing covering, repairing, restoring or cleansing or doing of
any act which may be necessary for the purpose of preserving or conserving, of or
securing convenient access to, a heritage building.
Explanation ll. - “Owner” shall, notwithstanding anything contained elsewhere in
the Act include, for the purposes of this chapter -
(a) a joint owner of a heritage building vested with the power of management
thereof on behalf of himself and any otherjoint owner, or successor in-title of any
such joint owner, or
(b) a manager or trustee, vested with the power of management of a heritage
building or successor- in-office of such manager or trustee.
(2) Where the ULB on the recommendation of the Heritage Conservation Committee
and also the Mayor/Chairperson of the ULB is of the opinion that any building in the ULB
should be preserved and conserved for historical architectural, environmental, cultural
and ecological purpose, it may declare such building as a heritage building;
provided that during the period when any proposal for declaring any building as
a heritage building under consideration of the Heritage Conservation Committee or the
Mayor/Chairperson of the ULB, no owner of such building or no lessee or sub-lessee to
whom such building has been leased out, shall transfer such building by way of sale,
lease or mortgage without prior approval of the Mayor/Chairperson of the ULB.
(3) The Mayor/Chairperson of the ULB shall constitute a Committee to be called the
Heritage Conservation Committee with the Mayor/Chairperson of the ULB as its
Chairman and the ln-Charge of Public Works Section as its Convener.
(4) The committee shall have, in addition to the Chairman and the convener, seven
other members as follows:-
a) one shall be a nominee of the District Magistrate of the District;
b) one shall be a nominee of the Director of the Department of Archaeology,
Govt. of Tripura/Govt. of India;
(c) one shall be an eminent Architect;
(d) one shall be an Artist;
(e) one shall be an Environmentalist;
(f) one shall be a Historian;
(g) one shall be the concerned Executive Engineer of the ULB/ Engineering
wing of UDD
(5) The Committee may co-opt any person to be nominated by the concerned
department of the State Government while dealing with any land or building under the
management of the said department.
(6) The Committee shall, in accordance with the provisions of the Act and the rules
and the regulations made there under scrutinize every application or proposal for:
declaration of a building as a heritage building, and recommend to and also advise the
Mayor/Chairperson in respect of preservation and conservation of such building.
(7) The committee shall meet as such periodical interval as may be determined by
the Chairman.
(8) The Chairman shall, in case of emergency take such measures as may be
Page 73
necessary for the preservation and conservation of a heritage building provided that
such measures shall be required to be approved by the Heritage Conservation
Committee at its meeting.
(9) The Heritage Conservation Committee shall have the power to function
independent of the ULBs for the purpose of preservation, conservation and maintenance
of heritage building in so far such power does not offend any other provision of the Act or
the rules made there under relating to construction or use of building:
provided that for erection or re-erection in a heritage building and part thereof or
for restoration of any heritage building to its old shape, design or beauty in the case of
unlawful demolition, or for making any change of internal and external wall, structural
pattern, floor, roof, interior or exterior architectural floor, facade or skyline or for any
other change, of a heritage building the provisions of the Act and the rules made there
under shall apply mutates mutandis.
(10) Subject to the other provisions of the Act the Mayor/Chairperson, may acquire,
purchase or take on lease any heritage building for the purpose of preservation and
conservation thereof ;
Provided that in the case of heritage building declared as such for the purpose of
preservation and conservation as required under the Tripura Town and Country Planning
Act, 1975, the approval of the concerned department of the State Government shall be
taken.
(11) When the owner of any heritage building is not willing to preserve or conserve
any heritage building, the Mayor/Chairperson may for the purpose of acquisition of such
heritage building by agreement and on the recommendation of the Heritage
Conservation Committee and with the approval of the ULB allow the transfer of right of
development of such heritage building, which shall be heritable and transferable, to the
owner of such heritage building in such manner, and subject to such conditions, as may
be prescribed.
Explanation l. - “Development" shall have the same meaning as in the Tripura
Town and Country Planning Act,1975.
Explanation ll.- "Right of development of a heritage building” shall mean the right
of development, in the prescribed manner, of such potentials as may be available in
respect of such heritage building on a plot of land different from the land and building
comprising the heritage building but in the same ward of the ULB.
(12) Subject to such rules or regulations as may be made under these rules and any
Act every person shall have the right to access to any heritage building acquired by the
ULB.
(13) The ULB shall have the right to allow the transfer of right of development to the
lessee of a heritage building where the unexpired period of the term of lease is for 90
years, and to take the heritage building on sub-lease by agreement, if there is provisions
for such sub-lease in the deed executed between the owner and the lessee, provided
that the question of payment of premium or rent in such case to the owner shall not,
notwithstanding any agreement in this behalf arise, and if the owner as confirming party
to the agreement waives the right to receive any further payment of such premium or
rent.
(14) If the ULB considers that it is necessary to acquire any building declared as a
heritage building for the purpose of preservation and conservation as required under
sub-clause (ii) of clause (a) of sub-section (4) of section 31 of the Tripura Town and
Country Planning Act, 1975, by agreement or under the Land Acquisition Act 1984,
permission of the concerned Department of the State Government shall be taken before
such acquisition.
(15) If the owner of a heritage building enters into an agreement with the ULB to
maintain, preserve and conserve such heritage building property at his own expenses
the ULB may, in such case, exempt wholly or partly the owner of such heritage building
Page 74
from payment of rates of taxes or fees for supply of water or any other charge in respect
of such heritage building.
(16)(i) The Mayor/Chairperson may pending acquisition of a heritage building by
the ULB under these rules or any Act and with the approval of the ULB propose to the
owner of such heritage building to enter into an agreement with the ULB for a specified
period for the maintenance of such heritage building;
(ii) the agreement as aforesaid may provide for all or any of the following
matters:-
(a) maintenance of the heritage building by the owner or by any other person
willing to maintain the said heritage building,
(b) custody of the heritage building and the duties of the person who may be
employed to watch it;
(c the restriction on the owners right-
(1) to use the heritage building for any other purpose detrimental to
its conservation.
(2) to chase any fee for entry into, or inspection of, the heritage
building, and
(3) to build on or near the site of the heritage building.
Previous and next
Questions people ask
Is rule 97 of TRIPURA BUILDING RULES — 2017 still in force?
No repeal of TRIPURA BUILDING RULES — 2017 is recorded.