LawGrids logoLAWGRIDS.ORG

Annexure 1, .lharkhand Building Bye-laws 2016: ANNEXURE-1

.lharkhand Building Bye-laws 2016 - Annexure 1

Text of annexure 1

ANNEXURE-1

ANNEXURE-1 - ;; ii) - 114 - Structural details and calculations of buildings on plot up to 500 square meters and up to three storied structure excluding basem ent/sti It. ~~ enrolled as Authority licensee, violates any of the rules, regulations, byelaws and I or planning standards of Authority. for the time being in force, his enrolment in authority shall be cancelled and the enrollment fee of Rs. 1000/- charged initially from him shall be forfeited 2) ENGINEER (A) Qualification and Experience:- The minimum qualification for an Engineer shall be Degree in Civil Engineering or equivalent. The qualification for licensing of Engineer will be corporate membership (Civil) of the Institution of Engineers or such Degree or Diploma in Civil or Municipal or Structural Engineering which make him eligible for such membership, of which is recognized by Union Public Service Commission for the post of an assistant Engineer. (B) Competence:- The Licensed Engineers shal I be competent to carry out the work related to the building permit given below and shall be entitled to submit: i) All plans and information connected with building permit. Subject to section-16.3 .2 D) Registration Fee:- Architects registered under the Council of Architecture Act 1972 shall be entitled for a registration as a licensed technical personnel of Authority without paying any licensing annual fees for the same, 111is shall not be binding on registration of an Architect engaged for any specific purpose. However if they desire to be enrolled as lifetime licensee of the Authority, a lump sum payment of Rs. 1000/­ (0ne Thousand ) shall have to be made to the Authority as a fee for such enrollment, so that Authority may be able to intimate them by post from time to time about the provisions of planning standards and building byelaws and other relevant information with amendments (if any ) in rules and byelaws of the Authority. But In case an architect - 115 - Engineers (India) ore uivalent degree in Civil Engineer from ~ ~---- his enrolment in authority shall be cancelled and the enrollment fee of Rs. I 000/- charged initially from him shall be forfeited. 3) STRUCTURAL ENGINEER A) Qualification & Experience:- The minimum qualifications for a structural engineer shall be degree in Civil Engineering/fellow of the Intuition of and or planning standards of Authority, for the time being in force, sound construction non-hazardous, functioning of the services incorporated in the building and for making adequate provisions for services and equipment for protection from the fire hazards as per the stipulations of the National Building Code of India in the buildings. ii) If he/she is found negligent in his/her duties and responsibilities the Authority may black-list an Engineer in case of serious defaults or repeated defau Its The registration shall be liable to be revoked temporarily or permanently by the Authority in such cases of negligence and defau It. D) Registration Fee:- The fees for this purpose shall be Rs. 5000/- for one calendar year and it may be renewed in next calendar years by paying Rs. 1000/- to the Authority. But In case an engineer enrolled as Authority licensee, violates any of the rules, regulations, byelaws provision as per the approval plans but also is in conformity with the stipulations of the ational Building Code 2005 and the BIS standards for safe and C) Duties & Responsibilities:- i) He/She shall be responsible for making adequate iii) Certificate of supervision and completion for all buildings. iv) Preparation of all service plans and related information. v) Issuing certificate of supervision for development of land for all area. - 116 - B) Competence:- The licensed structural Engineers shall be competent to prepare the structural details and calculations for all bui I dings and undertake supervision. In case of buildings having special structural features, as decided by the Authority, which are within the horizontal areas and vertical limits specified in Annex A of Part-II, A-2.2.1 (b) and A-2.4.1 (a) of NBC 2005 they shall be designed only by structural engineers. C) Duties and Responsibilities:- i) To prepare a report of the structural design. ii) To prepare detailed structural design, drawings and specifications and to prescribe the method and technique of its execution strictly on the basis of the National Building Code or relevant BIS specifications. iii) To supply copies of structural drawings to the site supervisor. iv) To inspect the works at all important stages and certify that the work being executed is up to the satisfaction of the Architect. v) To certify the structural safety and overall structural soundness of the building to the Architect. vi) To advise the Owner/ Architect/Engineer for arranging for tests and their reports for soil, building material etc. for his evaluation and design consideration. vii) To prepare the revised calculations & drawings incase of any revision with reference to the earlier submission of drawing and design in a particular case. viii) To submit the certificate of structural safety and over all structural soundness of building to Authority. ~'¢Xy Note - 5 years experience shall be relaxed to 2 year in the case of Post Graduate degree in Structural Engineering/ higher qualification. recognized foreign institution, with 5 year experience m structural engineering practice. township. ii) Certificate of supervision for development of land of all areas. C) Duties and Responsibilities:- He/she shall be responsible for making adequate arrangements to ensure not only that the work is executed as per the approved plans but also is conformity with the stipulations of the National Building Code, 2005 and the BIS ~ v .t -117- development of land of all areas including integrated xi) In case of multistoried buildings and buildings of a special nature as identified by the Authority from time to time, the structural Calculations/Drawings shall be got vetted by Indian Institute of Technology/National Institute of Technology or any organization empanelled by the State Disaster Management Authority or the Building Construction Department. D) Registration Fee :- The fees for this purpose shall be Rs. 5000/- for one calendar year and it may be renewed in next calendar year by paying Rs. 1000/- to the Authority. But In case an structural engineers enrolled as Authority licensee, violates any of the rules, regulations, byelaws and/or planning standards of Authority, for the time being in force, his enrolment in authority shall be cancelled and the enrollment fee of Rs. 1000/- charged initially from him shall be forfeited. 4) TOWN PLANNER A) Qualification & Experience:- The minimum qualification for a town planner shall be recognized Post Graduate Degree/Diploma in Town Planning and registered membership of ITPI and not be in arrears of subscription. B) Competence:- The licensed town planner shall be entitled to submit: i) All plans and related information connected with - 118 - functioning of the services incorporated in the building and for making adequate provisions for services and equipment for protection from the fire hazards as per the stipulations of the National Building Code of India 2005. D) Registration Fee :- The fees for this purpose shall be Rs. 5000/- for one calendar year and it may be renewed in next calendar years by paying Rs. 1000/- to the Authority. But In case an Town Planner enrolled as Authority I icensee, violates any of the rules, regulations, byelaws and/or planning standards of Authority, for the time being in force, his enrolment in authority shall be cancelled and the enrollment fee of Rs. 1000/- charged initially from him shall be forfeited. 5) SUPERVISOR/DRAFTSMAN A) Qualification and Experience:- The minimum qualifications for a supervisor shall be recognized Diploma 111 Civil or Architecture, or Draftsmanship in Civil or Architectural Assistantship plus 2 years experience in building design, construction and supervision. B) Competence:- The licensed supervisor/Draftsman shall be entitled to submit: i) All plans and related information connected with building permit for residential buildings on plot up to 100 sq. m. and up to two storeys, ii) Certificate of supervision for buildings as per (i). C) Duties and Responsibilities of Supervisor:- i) To adhere strictly to the architectural and structural drawings/ specifications and written instructions of the structural Engineer and Architect/Engineer. ii) To follow the provisions of NBC, 2005 or BIS specifications as regards materials, components, qualitx control and the process of construction. ~\>~(Y standards for safe and sound construction non-hazardous, 6) GROUP AGENCY i) When any Group or Agency comprising of qualified Architect /Engineer/ Town Planner is practicing, then the qualifications and experience, competence, duties and responsibilities and registration will be the combination of individual qualification and experience, competence, duties & responsibilities and registration as provided in Schedule lto5. ~ ~ f -119- caused in the course of his work in the people in neighborhood. D) Registration Fee - The fees for this purpose shall be Rs. 2000/- for one calendar year and it may be renewed in next calendar years by paying Rs. 500/- to the Authority. But In case an Supervisor/Draftsman enrolled as Authority licensee, violates any of the rules, regulations, byelaws and/or planning standards of Authority, for the time being in force, his enrolment in authority shall be cancelled and the enrollment fee of Rs. I 000/- charged initially from him shall be forfeited. iv) He shall be in charge of site and responsible for supervision of the work. v) He shall ensure that all the works under his charge are carried out in conformity with the approved drawing and as per the details and specifications supplied by the Architect/Engineer. vi) He shall take adequate measures to ensure that no damage is caused to the work under construction and the adjoining properties. vii) He shall also ensure that no undue inconvenience is iii) To bring to the notice of the structural Engineer and Architect/Engineer/any situation or circumstances which in his opinion are liable to endanger the safety of structure. - 120 - B) Registration/Renewal:- i) Registration of builders shall be done by the Authority. The registration shall be done in the prescribed form. The registration shall be valid for one calendar year and shall be renewable annually. The fee for initial registration of a builder shall be Rs. 75000/- and the renewal fee shall be Rs. 15000/- An application form for the registration of builders will be as follows:- ' ~"~~ -J 7) BUILDER A) Oualification:- i) A person/firm engaged m construction activities/ building activities in an urban area. ii) A person or group of persons having qualification of Civil Engineering, Architecture and Town Planning. iii) The Authority may classify the builders into different categories considering their experience, expertise and annual turnover. ii) The Authority may also empanel public undertaking/agencies engaged in development work for quick execution of Government/Private projects within its jurisdiction. Registration Fee The fees for this purpose shall be Rs. I 0000/- for one calendar year and it may be renewed in next calendar years by paying Rs. 2000/- to the Authority. But In case an Group Agency enrolled as Authority licensee, violates any of the rules, regulations, byelaws and/or planning standards of Authority, for the time being in force, his enrolment in authority shall be cancelled and the enrollment fee of Rs. 1000/- charged initially from him shall be forfeited. - 121 - Name of the applicant (Builder/Firm/ Developer) 2 Address of Applicant, issued by the officer, not below the rank of Civil SDO/SDM (a) Local Address (b) Permanent Address 3 Academic/Technical Qualifications (a) Builder/Developer (b) Name, Address and Technical Qualification of Engineer Associated with the builder/developer(Engineer should have recognized Degree/Diploma and 3 years minimum experience in civil building construction work). (c) Name, Address of Architect and Technical qualification (Architect associated with builder/developer should have Degree from recognized institution with 3 years minimum experience in civil building Planning work) 4 Service Tax Registration Number and Latest return of service Tax In case of new builder/ developer, Service Tax registration must be submitted by him within 3 months from the date of making investment in construction of Building/Apartment etc. 5 Current year Income tax return (Certified copy to be attached) 6 Affidavit to be submitted at the time of registration by the Builder I Developer that he would submit Labour License either in his own name or in the name of Labour Supplier employed by the Builder for construction of that specific project within 3 months from the date of start of construction of the project 7 Work Experience in Civil Construction work (if any) 8 (a) If Building Construction has been done by the applicant, mention the B.C. No. and Passing Authority with details. (b) Year of Building Construction A~~ ( applicant with application of photo passport Attach one more colour Paste passport size colour photo of applicant FORM OF APPLICATION FOR REGISTRATION OF BUILDER .. 122 - project and shall bear responsibility for any irregularity ~;~ Architect/Engineer/Town Planner to prepare plans, designs, drawings and specifications for execution of the works in accordance with the requirements of these bye laws. ii) He shall not cause or allow any deviations from the approved drawings in the course of the execution of the qualified a engage shall He/She/Firm i) C) Responsibilities:- Full signature of applicant with date Cost of Application Form ns0.00 Only (Non-Refundable) (c) Name of Land Owner/ Building Owner if the Land/Builder is not belonging to Builder/ Developer by self and certified copy of Mutual contract/agreement to be attached for construction of the Building/Apartment over that land 9 Character Certificate issued by the Deputy Commissioner/District Magistrate of period not earlier than 6 months IO Is any unauthorized construction case pending after the construction of the sanctioned building plan (If yes, mention its full details, Name of the Authority/Court, case no. and present status of case) Information to be submitted by affidavit. 11 Annual Turn Over of not below 50 lacs rupees duly Audited by Chartered Accountant for the last three years. (Certified copy to be attached) 12 Details of the Movable and Immovable Property to be supported by affidavit containing that the concerned Developer/ Builder is having property of value not below than 50 lacs rupees. 13 Is applicant registered for work in any department? (If yes, mention full details with Registration No.) 14 Details of Registration fee by way of DD payable in favour the Authority. For f 50,000/­ in case of new registration & fl 0,000/- in case of renewal. c) Credit facility/liquid assets. d) Bidding capacity of project. ii) Any other relevant criteria required as per Standard Bidding Document (SBD) of the project. iii) Registration with the BCD of Government of Jharkhand ~I~ .C: vr public sector undertakings. ,~ ~\ ~ -123- .. 8) Contractor A) Oualification:- i) A person/firm engaged 111 construction activities/ building activities in the State of Jharkhand/India. ii) Availability of - a) Ownership/proof of hire/lease. b) Equipment/key technical personnel required by labour laws. vii) He shall submit the completion certificate and obtain occupancy permission from the Authority. viii) He shall explain the construction I design and its intended use as per approved plan, to the pro pective purchaser of the premises under construction. committed in the use and function of the building or its parts for which the approval has been obtained. iii) He shall not commence the use of building or hall not give the possession to occupy the building to any one before obtaining the occupancy certificate from the Authority. v) He shall provide adequate safety measures for structural stability and protection against fire hazards likely form installation of services like electrical installation, plumbing, drainage, sanitation, water supply etc. whenever required under the bye laws. vi) He shall provide adequate for safety and welfare of the construction workers at the construction site as .. - 124 - A device to heat water using solar energy as heat source. (i) Electricity operated or fuel fired boilers/ systems to heat water (ii) "Auxiliary back up" coming out from solar water heating system to meet I continuous requirement of hot 1. Installation of Solar Assisted Water Heating System in Buildings: to ensure the implementation of the guidelines issued by ministry of non-conventional energy sources on accelerated development and deployment of solar water heating systems in domestic, industrial and commercial sectors. No new building in the following categories in which there is a system of installation for supplying hot water shall be built unless the system of the installation is also having an auxiliary solar assisted water heating system:- i) Hospitals and Nursing Home Hotels, Lodges, and Guest Houses, Group Housing with the plot area of 4000 sq m. iii) Hostels of Schools, Colleges and Training Centres with more than 1 00 Students. iv) Barracks of armed forces, paramilitary forces and police v) Individual residential buildings having more than 150 sq m. plinth area vi) Functional Buildings of Railway Stations and Air Ports like waiting rooms, retiring rooms, rest rooms, inspection bungalows and catering units vii) Community Centres, Banquet Halls, Barat Ghars, Kalayana Mandaps and buildings for similar use. A. Definitions "Solar Assisted Water Heating System Guidelines for installation of solar water heating system Annexurc-11 - 125 - 25 It. per day for each bathroom and kitchen subject to ~~ & recommended minimum capacity shall not be less than consultation with the local body. The be decided in 11. Existing Buildings: Installation of Solar Assisted Water Heating Systems in the existing building shall be made mandatory at the time of change of use to above said category provided there is a system or installation for supplying hot water. 111. Capacity: The capacity of solar water heating system to be installed on the building of different categories shall B. Guidelines for Installation of Solar Water Heating System i. New Buildings: Clearance of plan for the construction of new buildings of the aforesaid categories shall only be given if they have a provision in the building design itself for an insulated pipeline from the rooftop in the building to various distribution points where hot water is required. The building must have a provi ion for continuous water supply to the solar water heating system. The building should also have open space on the rooftop, which receives direct sun light. The load bearing capacity of the roof should at least be 50 kg. per sqm. All new buildings of above said categories must complete installation of solar water heating systems before obtaining necessary license to commence their business. water. Such buildings of above aid categories for which (iii) ·'New Building" construction plans have been submitted to the Authority for clearance. Such buildings, which are (iv) "Existing building" licensed to perform their respective business. - 126 - .. v. Auxiliary System: Wherever hot water requirement is continuous, auxiliary heating arrangement either with electric elements or oil or adequate capacity may be provided. 2. A separate guide lines shall be issued for installation of solar plant, solar power backup and metering system by the Urban Development and Housing Department. ~~r the condition that maximum of 50% of the total roof area is provided with the system. iv. Specifications: Installation of Solar Assisted Water Heating System shall conform to BIS specification IS 12933. The solar collectors used in the system shall have the BIS certification mark. ( Maximum Permissible SI. NameofULB FAR Residential Commercial l Ranchi Municipal Corporation As per Master Plan 2 Dhanbad Municipal Corporation & MADA Area 2.5 2.5 3 Chirkunda agar Panchayat 2.0 2.0 4 Giridih agar Parishad 2.5 2.5 5 Hazaribagh agar Parishad 2.5 2.5 6 Jhumritilya agar Parishad 2.0 2.0 7 Koderma agar Panchayat 2.0 2.0 8 Chas Municipal Corporation 2.5 2.5 9 Phusaro agar Parishad 2.0 2.0 10 Chatra agar Parishad 2.0 2.0 1 l Bundu agar Panchayat 2.0 2.0 12 Gum la ahgar Panchayat 2.0 2.0 13 Lohardaga agar Parishad 2.0 2.0 14 Simdega agar Parishad 2.0 2.0 15 Khunti Nagar Panchayat 2.0 2.0 16 Ramgarh Nagar Parishad 2.0 2.5 17 Dumka Nagar Parishad 2.5 2.5 18 Basukinath Nagar Panchayat 2.0 2.0 19 Deoghar Municipal Corporation 2.5 2.5 20 Madhupur agar Parishad 2.0 2.0 21 Godda Nagar Panchayat 2.0 2.0 22 Pakur Nagar Panchayat 2.0 2.0 23 Sahebganj Nagar Parishad 2.0 2.0 24 Rajmahal Nagar Panchayat 2.0 2.0 25 Mihijham agar Parishad 2.0 2.0 26 Jamtara Nagar Panchayat 2.0 2.0 27 Chaibasa agar Parishad 2.0 2.0 28 Chakaradharpur Nagar Parishad 2.0 2.0 29 Jamshedpur NAC 2.5 3.0 30 Mango NAC 2.5 3.0 31 Jugsalai Municipality 2.5 3.0 32 Chakuliya Nagar Panchayat 2.0 2.0 33 Saraikela Nagar Panchayat 2.0 2.0 34 Adityapur Nagar Parishad 2.5 3.0 35 Medininagar Nagar Parishad 2.5 2.5 36 Hussianabad Nagar Panchayat 2.0 2.0 37 Vishrampur Nagar Panchayat 2.0 2.0 ;") ~ ~//)'?'!J. - 127 - .. Annexure-111 Maximum Permissible FAR for Different ULBs - 128 - .. FAR value as and when required. respective up coming Master Plan of Towns. The Urban Development & Housing Department can altered/modified For other occupancy the FAR value shall be as per these Bye-laws. (2) The FAR value may be altered/modified according to the Note:- (I) 38 Garhwa Nagar Panchayat 2.0 2.0 39 Nagar Untari Nagar Panchayat 1.5 1.5 40 Manjhiaon Nagar Panchayat 1.5 1.5 41 Latehar Nagar Panchayat 1.5 2.0 42 Ranchi Regional Development Authority, As per Master Plan Ranchi I Name of the Firm - 2 Registration of the Firm - Details of land on which tower Photo is to be installed (land related 3 paper): (a) Photocopy of sale deed/lease (b) Photocopy of Khatiyan (c) Photocopy of Mutation (d) Photocopy of Rent receipt 4 Land/Building Owner of Consent Paper/ Agreement - Certificate satisfy that CJ CJ 5 proposed tower shall be able to - carry wind pressure. Proposed tower is not in a air CJ CJ 6 traffic zone a certificate from Airport Authority has been - attached for the same. A certificate that the concern CJ 7 building is capable of carrying - CJ load of the proposed tower. 8 Photocopy of structural design - of propose tower. Height of the proposed tower 9 shall be measured form ground --------------------------------------------------------- floor of the building on which - ----------------------- 111. tower is going to be installed. (a) If height is less than 40111. and outside 7km. than whether on line application has been made or not. A oath with CJ CJ detailing out that in case of any - objection/rejection correction 10 measures shall be taken out by TSPs/IPs. OR (b) If height is above 40m. and CJ D under 7km. then a certificate of SACFA/Airport Authority of India is available or not. Acknowledgement receipt has been enclosed or not by CJ CJ TSPs/lPs in context of self 11 certificate produced before - TERM CELL of DOT with regard to EMR. OR ' ~ -r= - 129 -

Previous and next

All provisions of .lharkhand Building Bye-laws 2016

Questions people ask

Is annexure 1 of .lharkhand Building Bye-laws 2016 still in force?

No repeal of .lharkhand Building Bye-laws 2016 is recorded.