LawGrids logoLAWGRIDS.ORG

Annexure D, Legal Metrology (General) Rule, 2011: ANNEXURED

Legal Metrology (General) Rule, 2011 - Annexure D

Text of annexure D

ANNEXURED

ANNEXURED TYPICAL EXAMPLES This annexure contains diagrams of weights used for testing of high capacity weighing machines, which are considered suitable for use as patterns because of their design and ease of use. RECTANGULAR STANDARD WEIGHTS 500 kg. and 1000 kg. SUITABLE FORSTACKING Dimensions (mm) .... ??? --=----·:?rJ - ----?'+•o, ., _J .. ft - . ! It "' !-· ·- -· ? I - i . ?M - - 500kg 1000kg .a 273 504 b 100 120 C 0100 0140 .. . . ·-· .. - ·- '.--:-:::-.',. - ['!l'III-=3(i)] 353 RECTANGULAR STANDARD WBGHT 1000 kg SUITABLE FOR STACKING o, • J-----, ----ii-- I o :.. ! 111\ . . . .. '---?--..., . - .... I'? ?' -'...??· -? IE § .•. - s - ... .. • "'' ·"\. - ? ,, 'J - • - ? -?-_:_- ?==-=-==--_:_c___:____:_:;.::__ _ __:_-_ce"'--"·=· ==--?-?===--------- 3S4 THE:GAZETTE OF INDIA: EXTRAORDINARY , CYLINDRIC.AL STANDARD WEIGlfTS 500 kg and 1000 kg Sl!JITABLE FOR STACKING AND ROLLING Dimensions (mm) FOR 500 kg WEIGHT [PARTll---SEC. 3(i)] [r = 10 R = 20] ---·----- ---------------- ' ['WT Il-eFs3(i)] 355 Cylindricalmeasures Conical measures Dipping type Pouring type 2. Denominations The denominations of the different types of measures shall be as under : SIXTHSOiEDULE SPEOFICAlIONSFORMEASURES [See Rule 12] PART I· UQUID CAPAOTY MEASURES 1, General This Part deals with two types of cylindricalliquid measures, namely the dipping and the pouring types, and one type .ofconical measures. TABLE 11 Nominal Dimensions of Cylindrical Capacity Measures G 1 litre 500ml 200ml 100ml 8 Conical measures Max. Min. Min. H 100ml 50ml 20ml Cyffndricalmeasures 50ml 20ml Denominations D Dipping type Pouring type 3. Shapes and dimensions (a) The shape and dimensions of cylindrical measures (dipping and pouring types) shall be as shown in Figures 12 and 13 and Table 11. 20 litres 10 litres 5 litres 2 litres 2 litres 1 litre 500ml 200ml 1 litre 500ml 200ml 100ml I H 100 lltill ml - L..? i I i i RIVETED j { ?LOED, i SOUlfRl:D j OURAZED I ! 100 llr.n ml ' l ! i ' 11-o I i '- .. ?,- .... ?•••n--•'"--••••-•••-H,_, io---o----i ti'l'PIIOXl IWETED IIELDED, SOLDERED OR BRAZED i-----0---1 DIPPINGlYPE CYLINDRICAL MEASURES (SCHEMATIC) FIGURE-12 POURING 1YPE CYLINDRICAL MEASURES (SCHEMATIC) AGURE-13 . .J. _ 356 THE GAZETTE OF INDIA: EXTRAORDINARY [PARTII-SEC. 3(i)) (b) The shape and dimensions of conical measures shall be as shown in Figure 14 and Table 12. TABLE12 NOMINAL DIMENSIONS OF CONICAL CAPACITY MEASURES Denomination A 8 C D E F G H J K M Min. 20 litres 97 388 288 208 194 390 1.00 35 86 29 30 10 litres 77 308 307 174 154 309 1.00 30 75 26 25 5 litres 61 244 245 147 122 247 0.80 25 65 24 20 2 litres 45 180 180 118 90 182 0.80 20 56 22 16 1 litre 36 143 143 95 72 145 0.63 20 45 18 16 500ml 28 114 113 74 56 115 0.63 15 35 14 12 200ml 21 84 84 53 42 86 0.63 10 24 10 8 100ml 17 66 67 41 34 69 0.63 10 18 7 8 Note 1 : All dimensions in millimetres. Note 2 :Tolerance on dimensions± 10 per cent except in case of 10 litre and 20 litre measures for which the tolerance shall be ± 5 per cent. 4. Material (a) Cylindricalmeasures-The bodyofcyllndrical measures shall be manufactured In one piece from aluminium alloy sheets, brass sheets or stainless steel sheets. The minimum thickness of the sheets shall be as specified in Table 11. (b) Conical measures-The conical measures shall be fabricated from galvanised steel sheets, aluminium alloy sheets, copper sheets, brass sheets, stainless steel sheets . or tinplate. The minimum thickness of the sheets shall be as specified In Table 12. (c) The handles for the measures shall be fabricated from the same material as that used for the body. 5, Manufacture and finish (a) Cylindricalmeasures made of brass sheets and copper sheets shall be tinned or tin-plated uniformly all over the inside as well as the outside surfaces. Conical measures made of brass sheets or copper sheets, shall be well tinned or tin-plated uniformly all over the inside when they are used for measuring commodities like milk, edible oils and such other food artlcles. (b) The handles shall be of robust construction and shall be well formed and shaped generally as shown In Figure 12, 13 and 14. They shall be securely fixed to the body by means of riveting, soldering or brazing. Note .t: Capacity measures when used for measuring milk shall have the handle fixed by welding, soldering or other suitable methods. Brazing so as not to leave pockets in which dirt may accumulate. Note 2: Dipping type of cylindrical measures may also have handles substituted by two suitable but diagonally opposite brackets affixed to the walls of the measure by means of soldering, brazing or welding so as to hold the measure properly by a handle at right angles to the walls of the measures · to facilitate Its use in hot and boiled milk trade. (c) The measures shall be free from any surface defects and indentations and shall be smoothly finished at the top. (d) Cylindricalmeasures shall be provided with a well formed and proportioned spout to facilitate pouring. (e) Conical measures shall be provided with a retaining lip to avoid spilling. The retaining Upshall be provided with a plug of suitable --------? -,-?•1,-···?··· [ 'lT'T II -1!i"6 3 (i ) ] 357 ----8 ----11 } I I I C H NAME AND DENOMINATION PLATE F· ---DIA---? RIVETED WELDED SOLDEERED OR BRAZED POURING 1YPE CONICAL MEASURE (SCHEMATIC) RGURE-14 material with a collar to receive the lead for the Legal MetrologyOfficer's seal. A small hole, about 5 mm in diameter shall be provided at the bottom of the retaining lipto indicate the level to which the measures shall be filled and the hole shall be located on the side at right angles to the handle. The bottom of conical measures shall be suitably reinforced. (f) The measures shall be so designed that, when they are tilted 120 degrees from the vertical, they shall become o:impletelyempty. (g) The finished measures shall have adequate robustness for durability. 6. Permissible error The maximum permlssible errors shall be as specified: measures measures ml ml 20 I 100 10 I 50 51 30 21 30 15 11 20 10 500 ml 15 8 200 ml 8 4 100 ml 5 3 50 ml 3 20 ml 2 Lt7Y ,:;{J,r?qo Inspection 25 15 15 . 7.5 10 5 7.5 4 5 2 2.5 1.5 1.5 1 Denomination Verificatlcn In excess only Cylindrical Conical Cyllndtical · Conical measures measures Excess Deficiency Excess ml Error same as Error same as in verification in verification _J __ Deficiency ml 50 358 THE GAZETTE OF INDIA:EXTRAORDINARY [PARTll--SEC. 3(i)] 7. Markjng (a) ,Every ,cyllndr.lcalmeasure shall have the denomination and manufacturer's name or trade mark Indelibly stamped on it. In the case of conical measures, the denomination and manufacturer's name or trade-mark shall be either embossed on the body or indelibly marked on a name plate securely fixed to the body. (b) The denominations shall be Indicated with the abbreviations 'I' and 'm' for litre; and 'ml' and 'iilm' to Indicate millilitre •. Note :The abbreviation 'm' or 'iilm' may be Indicated in the regional script. The size of numerals and letters Indicating denominations on the measures shall be twice the size of the letters Indicating the manufacturer's name or trade mark. 8, Stamping (a) Cylindrlcal a,pacity measures: The Legal MetrologyOfficer's seal shall be stamped just above the indication of the denomination of the capacity measure. (b) Conical capacity measures: The Legal Metrology Officer's seal shall be stamped on the lead pellet provided for this purpose. PART II DJSPENSINGMEAS\JRES 1, General This Part deals with two types of dispensing measures made of glass or transparent plastic materials, used for dispensing purposes. Conical dispensing measures of capacity 100 ml may also be used in the sale of liquor. 2. Types and denominations Dispensing measures shall be of the following types and denominations:- (a) Conical measure.r-200 ml, 100 ml, so ml, 20 ml, 10 ml and 5 ml. (b) Beakermeasure.r-1000 mi and 500 ml. 3. Materials (a) Glass measure.r-The measures shall be made from clear and transparent glass. They shall be well annealed; free from stones, cracks and chippings; and as free as possible from blisters and other defects. - z.=iift:: N Lead glass shall not be used for the measures. (b) Transparent plastic measures-The measures shall be made from a clear and transparent plastic material, manufactured from plasticised polyvinyl chloride or copolymer, the major constituent of which Is polyvinylchloride. The plastic materials used shall not contain any constituents known to be injurious to health and likelyto be extracted by contact with liquids. 4. Definition of capacity The capacity corresponding to any graduation marks Is defined as the volume of water at 27°C, expressed In millilitres, required to fill the measure to that graduation mark at 27°C,the observer's eye being level with the front graduation marks and the lowest point of the water meniscus appearing to touch the top edge of that mark. 5. Shape, construction, etc. of conical measures (a) Shape-The measures shall be conical as shown in Figure 15A to 15G. The SO ml measures shall be· either tall or squat as shown in Figure lSC and 150 respectively. (b) Construction- (1) Each measure shall have a pouring lip. The form of the lip shall be such that, when the measure is filled with water to the highest graduation mark, the contents may be poured from the lip in a stream falling clear of the outside of the measure. {II) Each measure shall have a base on which it shall stand vertically without rocking when placed on a horizontal surface. The size of the base shall be such that the measure, when empty, shall not fall when placed on a plane inclined at 15° to the horizontal. The bottom of the measuring space shall be uniformly rounded and shall merge smoothly Into the sides of the measure. (Ill) The wall thickness of the measures shall be sufficient to ensure sturdy construction and shall not show any local departures from uniformity. (Iv) The external surface of the measure shall be a cone having an included 359 angle of not less than 13° and not more than 14°. (v) The overall volume of the measure shall be such that when It Is filled with water to the highest graduation mark and a volume of water equal to half its nominal capacityIs.added to it, there shall be no overflow. But, the addition of a further quantity of water equal to quarter the nominal capacity shall result in water overflowing from the pouring lip. (c) Graduatlons- (1) The conical measures shall be graduated in accordance with Table 13. (ii) With the pouring dip of measure facing to the right, the front graduation marks shall be placed at right angles to and on the right hand side of a vertical line extending from above to the top graduation mark to near the base of the measure and below the bottom graduation mark. (iii) The graduation marks shall be marked as shown in Figure lSA to lSG. The marks shall be engraved or etched · and they shall be of a uniform . thickness not exceeding 0.3 mm., provided that they may taper slightly towards the ends. The graduation marks shall lie In planes perpendicular to the axis of the measure and shall be horizontal when the measure is standing on a horizontal surface. (iv) Each graduation number shall be etched or engraved close to the end of the graduation mark to which it relates and In such a manner that It would be bisected by a prolongation of that graduation mark. (v) The numbered graduation marks shall have the minimum length specified In Col. 7 of Table 13. The unnumbered graduation marks shall be at least two-third the length of the numbered graduation marks and dearly shorter than the numbered marks. TABLE13 Details of Conical Measures Denomination Graduated Numbered Back Lowest Af. Af. Lines Graduation At mark Height of lowest graduation Mark above bottom of measuring space Minimum length of mark l 2 4 5 ml ml ml ml ml 200 50, 100, 120, 50, 100, 120, 50, 100, so 140, 160, 140, 160, 180, 200 180,200 200 100 Every 10 ml 10, 20, 40, 60, 20, 60, 10 from 10 to BO,100 100 100ml 50 (Tall) Every 10ml · 10, 30, 50 30, 50 10 from 10 to 50 ml 50 (Squat) Every 10 ml 10, 30, so 30, so 10 from lOto 50ml 20 Every 5ml 5, 10, 20 10, 20 5 from 5 to 20ml 10 Every ml 2, 4, 6, B, 10 2, 6, 10 2 from 2 to 10ml 5 Every ml 1, 3, 5 3, 5 1 from 1 to 5ml 7 cm cm 6.5±0.5 2.0 3,0±0,5 1.75 4.0;t0.5 1.5 2.0;t0.5 1.5 2.5:1:0.5 1.25 2.5±0.5 1.0 2.5±0.5 0.75 360 THE:GAZETTE OF JNDIA:EXTRAORDINARY [PARTII--SEC.J(i)] {vi) The height of. the lowest.qraduatlon merk-above.the-iowest ,point of the FIGURE-15A 2000ml ?ml , i . ., ' FIGIJREalSB '100:ml FIGURE-15C 50ml (Tall) bottom of the measuring space shall be within the limits given in Col. 6 of Table 13. FIGURE-150 FIGURE-15E 50 ml 20ml {SQUAT) I WFJ Ji (d) Permissible errors-The maximum permissible errors on verification or on inspection shall be as specified below (in ml): 200, 180, 160 ± 3.0 140, 120, 100 ± 2.0 90, 80, 70, 60 ± 1.5 Measures except SO ml (Squat) SO ml (Squat) measures Capacity corres­ ponding to graduation mark (1) 50, 40 30 20 15 10, 9 8, 7, 6 5 4 3 2 1 (2) ± 1.0 ±0,8 ± 0.6 ± 0.5 ± 0.4 ± 0.3 ± 0.25 ± 0.20 ± 0.16 ± 0.12 + 0.08 (3) ± 1.00 ± 1.00 ± 0.80 ±0,6 F!GURE·15F F!GURE·JSG 10ml S ml Note :The permissible errors, apart from those of the 50 ml squat measure, apply to graduation marks corresponding to the capacities stated, irrespective of the nominal capacity of the conical measure concerned. 6. Shape a,nstruction, etc. of beaker measures (a) Shilpe-The measure shall be in the form shown in Figure 16A and 168. {b) Construction-- (i) Each measure shall be provided with a pouring lip. The form of the lipshall be such that, when the measure Is · filled with water to the highest graduation marks, the contents may be poured from the lip in a stream falling clear of the outside of the measure. (ii) Each measure shall be provided with a base on which it shall stand vertically without rocking when placed on a horizontal surface. The size of the base shall be such that the measure, when empty, shall not fall when, placed on a plane inclined at 15° to the horizontal. The bottom of the measuring space shall be uniformly rounded and shall merge smoothly into the sides of the measure. (iii) The overall volume of the measure shall be such that when the measure is filled with water to the highest graduation mark and a volume of - -- - ·-?---:-- 361 water equal to quarter the denomination volume is added to it, the water shall not overflow. (c) G!'i1dimtlons- (i) The graduation rnerks shall be marked as shown in Figures 16A and 16B and Table 14. The marks shall be etched or engraved and shall be of a uniform thickness not exceeding 0.3 mm, provided that they may taper slightly towards the ends. The graduation marks shall lie in places perpendicular to the axis of the measures and shall be horizontal when the measure is standing on a horizontal surface. (ii} Each graduation numbered shall be etched or engraved close to the end of the graduation mark to which it relates and in such a manner that it 1000 ml would be bisected by a prolongation of that graduation mark. (iii) The distance between the highestand the lowest graduation marks and the height of the lowest graduation mark above the Inside of the base of the measuresrall be In ao::ordarcewith Cols. (3) and(4) respedivel'/ oflable 14. (d) Permissible envl'-The maximum permissible · errors on verificati011or on Inspectionshall be ± 7 ml for 1000 ml measures and ± 5 ml for 500 ml measure. · 7. Marking Each measure shall have permanently and legibly engraved or etched its denomination in Jndo-Arabic numerals, the abbreviations 'ml' and 'Mil' being used to indicate millilitres. The manufacturer's name or trade mark shall be marked on the underside of the base of each measure. Note: The abbreviation '11@1' may be indicated in (egionalscript. 500 ml BEAKER MEASURES OF METRIC SERIES FIGURE·16 A FIGURE-16 B 362 'ffHE·.GAZETJ:E OF .JNDIA: EXTRAORDINARY TABLE14 '.GRADUATION,AND DIMENSIONS OF BEAKER MEASURES [PART!I-SEC. 3(i)) Deno­ mination (J)ml 1000 500 ·Graduation ,at ;(2) 200to:IODOml ·at ·each 1:00 ,ml;numbered 'back lines at 200,600and 1000ml lOOto 500ml at each SO ml; numbered at each 100 ml; unnumbered back lines at 100,300 and 500 ,Distance .between Jowest& .highest · graduation marks (J)cm 11±1 9±0.S Height of lowest graduation mark above bottom of measuring surface (4)cm 4±1 3±0.5 Diameter of top (*S)cm 12 10 Min. Diameter of base (*6)cm 9 8 Overall height (1) 23 18 minimum thickness of the sheet for liquor measures shali be 1.2 mm. 5. Shapes and dimensions The shapes and nominal dimensions of hand operated liquor measures and automatic liquor measures shall be as given in Figure 17, 18 and 19 respectively. 6. Manufacture (a) Liquor measures made of brass sheet shall be well tinned or silver-plated uniformly all over the Inside as well as the outside surface. (b) Hand operated liquor measures shall be well formed, Measures of 60 ml and 30 ml capacity may be joined together with a common stem by brazing. (c) The measures shall be free from any surface defects and indentations and shall be smoothly finished. (d) Automatic liquor measures shall be capable of delivering 30 ml of liquor when tilted at an angle of 120 from the vertical. (e) Hand operated liquor measures shall have a knurled edge. 7. Permissible error The maximum permissible errors shall be as given . below:- * these are only recommendatory 8. Stamping The Legal Metrology Officer's seal shall be affixed after each verification just above the uppermost graduation marks. PART III· UQUOR MEASURES 1, General This Part deals with the requirements for liquor measures of two types. 2. Types Liquor measures shall be of the following two types:- (i) Hand operated, and (ii) Automatic. 3. Denominations The denominations of the types of liquor measures shall be as given below:- Hand operated : 100 ml, 60 ml and 30 ml. Automatic : 20 ml. 4. Material The body of the liquor measures shall be made from glass or brass sheet or. stainless steel sheet The Denomination 100 ml 60 ml 30 ml •. Permissible error ±3ml ±2ml ±lml 363 M 30ml 38 i i I i i I _,) (.. ., ·, -,:;,-·-·-·-·-·-··? \ I l i , .) \. ,., '· "4--·-·-·---?.:. SHAPE AND NOMINAL DIMENSIONS OF COMBINED LIQUOR MEASURES ? 100ml i ! ,) '· ·' '·,. '·-·..,.-·-·-·-? 67 22 32 ?ml. 100 ml, 60 ml and 30 ml capacity FIGURE-17 ft-- 48 •--ti SHAPEANDNOMINALDIHENSIONS OF COMBINED LIQUOR MEASURE 60 ml and 30 ml capacity FIGURE-18 ' ' 64 l_1 fl SHAPE AND NOMINAL DIMENSIONS OF AUTOMATIC LIQUOR MEASURE FIGIJRE-19 364 THE GAZETTE OF INDIA: EXTRAORDINARY [PAJITII-SEC. 3(i)] Metallic measures lm O.Sm 8. Markings (a) Every liquor measure shall have the denomination and manufacturer's name or trade mark legibly and indeliblymarked on it. (b) The denomination shall consist of international form ·of Indian numerals and the abbreviations 'ml' and 'film' to Indicate millilitres. The size of numerals shall be twice the size .of the letters indicating the manufacturer's name or trademark. Note :The abbreviation 'fiR;ft' may be Indicated in the regional script. 9. Stamping Legal MetrologyOfficer's seal shall be affixed after every verification just below the indication of the denomination mark. PARTJV· LENG'JH MEASURES (NON-FLfXIBLE) 1. General This Part deals with the non-flexible type of length measures made or manufactured from metal or wood. 2. Denominations The denominations of the length measures shall be as follows :- Wooden measures 2m lm 0.5m 3. Material, shape, etc. of metallic measures (a) Material-The measures shall be made from · mild steel, brass or stainless steel. (b) Shape and dimensions-The shape and dimensions of the measures shall be as is shown in Figure 20. (c) Graduationr-The graduation marks shall be made at every centimetre or at every centimetre for the first ten centimetres and thereafter at every five centimetres. The graduation marks at every ten centimetres shall be numbered. The marks at the centimetre divisions shall extend over half the breadth and thoseatflvecentimetre divisions over full breadth of the measures. A cross mark shall be provided at 25 cm in the case of 0.5 m measure and at 25, 50 and 75 cm In the case of 1 m measure (See Figure 20). The graduations shall be only on one side of the measure. (d) Permissible erro!'-The error on the length between any two consecutive five centimetre graduation marks shall not exceed± 0.25 mm and further the error from the beginning of the measure to any graduation mark shall not exceed 1.0 mm for 1 metre bar and 0.5 mm for half metre bars provided that the errors on the full length of the measures shall not exceed the following limits : Denomination Verification Inspection Excess Defidency Excess Deficiency 1 m 1.0 mm 0.5 mm 1.0 mm 1.0 mm 0.5 m 0.5 m 0.25 mm 0.5 mm 0.5 mm (e) Provision for stampim- The measures shall be provided with a copper rivet near each end (see Figure 20) firmly fixed in a hole, countersunk on both sides, for the Legal Metrology Officer's stamp. An arrow head shall be marked at each end of the measure to providethe points for checking the length. 4. Material, shape, etc. of wooden measures (a) Materials-The measure shall be made from well seasoned timber of any one of the following species :- (a) Teak ( Tectona grandis Linn. lj (b) Roseweed (Delbergia Latifolia Roxb) (c) Shisham (DalbergiasissooRoxb) &.L.,., .... , i====::J c==:::i c===:::J? CGPPERRN£RT FOR SEAL SECTIONAL ENLARGED VIEW OF RIVET ENLARGED VIEW OF REVERSE SiDE METALLlC LENGTli MEASURE FIGURE-20 365 (d) Haldu (Adhinacordifo!iaHoock./j (e) Bljasal (Pterocarpus marsupium Roxb) (f) Boxwood (B!axuxsempervirens) · (g) Beech (Fagus syfvam:a) (b) Shape and dimensionr The shape and dimensions of the measures shall be as shown in Figure 21 . 8.0+0.Smm?l shoped21SWGBras.iStnp . , • • ir 2m I ' , ,, I I ' ' ' ' ,L I I t .•200an ?o .? .. I! 0 w ?· ' "' i. r ViewofRevitrseSide S«1ionalEnlarged?1cw lflet2mctres XYZ WOODEN MEASURE FIGURE-21 (c) Graduationr-Thegraduation marks shall be made at every centimetre for the first ten centimetres and thereafter at every five centimetres. The graduation marks at every ten centimetres shall be numbered. The marks at the centimetre divisions shall extend over half the breadth and trose at the five centimetre division over the full breadth of the measures. A cross mark shall be provided at e1ery 25 cm, excludingthe one metre and two metre graduations. (See Figure 21) Last and first marks shall coincide with the end faces. The graduation shall be on one side of the measures only. (d) Permissible error-The error on the length between any two consecutive five centimetre graduation marks shall not exceed ± 1 mm, and further the error from the beginning of the measures to any graduation marks shall not exceed 2 mm, for 2 metre bar, 1 mm for 1 metre bar and 0.5 mm for half metre bar provided that the errors on the full length of the measure shall not exceed the following limits : Denominati0/1 Verification Inspection Excess Deficiency Excess Deficiency 2m 4mm 2mm 4mm 4mm lm 2mm 1mm 2mm 2mm 0.5mm 1mm 0.5mm 1mm 1mm (e) Provision for stamping-Each measure shall be provided at each end with a metal tip not less than 1 cm in width, securely riveted with two rivets at each end, as shown in Figure 21 for receiving the LegalMetrologyOfficer's stamp. The width of the tips shall be included in the total length of the measure. s. Manufacture and finish (a) The measure shall be evenly finished and shall be reasonably straight. (b) In the case of metallic measures, the graduation marks and the cross marks shall be legible and deep enough to ensure 366 THE GAZETTE OF INDIA: EXTRAORDINARY [PARTII-SEC. 3(i)] lndelibilityover a reasonably long period of use, but .not so deep as to make the measures liable to be easily bent. In the case of wooden. measures, the markings shall be finished neatly, sharply and legibly, in a colour contrasting with the wood finish. They shall be visible from a distance and shall remain indelible over a reasonably long period of use. 6. Marking (a). The denomination shall be stamped on the ungraduated side of the measure at about one-third of the total length from the beginning of the measure and the manufacturer's name or trade mark at a similar distance from the end of the measure. In the case of wooden.measures, the markings shall be finished in the same manner as the graduations. (b) In Indicatingthe denominations the numerals shall be preceded by the word '>im' and followed by metre. The size of numerals and letters, indicating denominations of the measures shall be twice the size of the letters indicating the manufacturer's name or trade mark. (c) The end of the measure shall be marked on the graduated side with the International form of Indian numeral Indicating the denomination, preceded and followed by the letters 'm' and 'm'. Note:Theword and abbreviation'>im' or'i:it' may be indicated In the regional script. PARTY-FOLDING SCALES 1. General This Part deals with wooden folding scales. 2. Denominations The denominations of folding scales shall be 1 m and O.Sm. 3, Materials (a) The scales shall be made from strips or sheets of wood. They shall be reasonably uniform, In width and thickness throughout the entire length. (b) The scales shall be made of any one of the followingspecies of timbers:- (1) Boxwood (Buxus sempervtrens) (ii) Gardenia (Gardenia sp) (iii) Parrotla (Parrotia jucquemontlana) (Rand/a dumetorom) (iv) Dudhl ( Wrtghtia sp) (v) Bamboo. (vii Haldu (Adina cordifolla Hoock f.) (vii) Kalam (Mltragyna pafVlfollakorth) (viii) Kuthan (Hymenodlctyon excelsum wall) (Ix) Gamri ( Gmellna abrorea Linn) (c) The timber shall be thoroughlyseasoned and radially sawn. The moisture content of the timber shall be between 8 and 12 per cent. The timber shall be free from knots, cracks, sap wood, shakes and other visible defects such as decay, insect attack, etc. and shall be fairly straight-grained. 4. Manufacture (a) General-The scales shall be reasonably straight and flat, the edges parallel to each other and the ends reasonably square. (b) No point on any of the edges shall be more than 0.5 mm distant from the straight line connecting its extremities. No point on the surface of a scale shall be more than 0.5 mm distant from the plane of the surface. (c) The scales shall consist of four pieces hinged together and it shall be an end measuring scale. (First and last graduation shall be the end face). The joints shall work smoothly without undue play and shall be sufficiently free from the folds to be opened and closed . without strain. The brass caps shall be closely fitted and strongly secured to the blades. They shall be made flush with the sides of the scales. (d) A protective layer of suitable lacquer or varnish or any other suitable material shall be provided. s. Dimensions The principaldimensions of the scale blanks shall be as follows :- length of graduated Width max. Min. Thickness pa,t (m) (mm) (mm) . (nm} 0.5 15.0 14.5 4 ± 1 1 20.0 19.0 5 ±1 6. Graduations (a) Graduation marks shall be made at every millimetre with a longer line at every S mm and centimetre. The length of the graduation lines shall be as follows:- cm marks 6 mm 5 mm marks 4 mm 1 mm marks 2..5 mm (b) The lines shall be fine and clear, of uniform depth and thickness, and perpendicular to the edges. The thickness of lines shall be not more than 0.2 mm for stamped scales and 0.1 mm for engine divided scales. The lines shall be of sufficient depth to be legible and Indelible. [ 'WI II <li"6" 3 (i ) ] 367 (c) The lines shall be fill? in black and natural background or with a suitable colour which shall contrast with thecolour of the base to. ensure legibility. (d) Every centimetre shall be numbered in international form of!ndian numerals. The height of the figures shall be between 2 .0 and2.Smm. 7. Permissible error The cumulative error for the entire graduated part shall nl exceed ± a.so mm. Further, over any 10 cm length scale, the error shall not exceed± 0.2 mm. 8. Marking (a) The denomination shall be stamped on the ungraduated side of the measure at a distance about one-third of the total length from the beginning of the measure. The manufacturer's name or trade mark shall be indicated Indeliblyat the same distance from the other end of the measure. The markings shall be finished in the same manner as the graduations. (b) In indicatingthe denominations the numerals shall be preceded by the word "ifm" and followed by 'metre'. Note :The word "-iim" may be Indicated In the regional script. 9. Stamping The LegalMetrology Officer's seal shall be affixed either on the metal strip at the ends or the central ·hingeas may be convenient. . PART VI-FABRIC OR PLASTIC TAPE MEASURE 1. General (a) This Part deals with fabric or plastic tape measures, which are used for measurements, where the use of rigid length measures Is not convenient or practicable. (b) Tape measures of 0.5 m to 5 m, made of materials specified in clause 4(b), are intended to be used for measurements required In the tailoring trade, anatomical measurements or household measurements. lllpe measures of 5 m and above made of materials specified in clause 4( c) are intended to be used for measurements of buildings, roads, timber and timber products and for other similar measurements but not for measurements of land, storage tanks, fermentation vats and other similar measurements. 2. Classes of accuracy Fabric or plastic tape measure shall be divided into three classes of accuracy, namely, aass I, Class II and Class III, in accordance with their accuracy. 3. Nominal lengths Fabrics or plastic tape measures shall be made in nominal lengths of 0.5 m, 1 m, 1.5 m, 2 m, 3 m, 4 m, 5 m or multiples of 5 metres, provided that the maximum nominal length shall not exceed 100 metres. Note :The nominal length of a fabric or plastic tape measure is the distance at the reference · temperature of 20°C between the initial and term Ina I graduation lines, when the tape measure is stretched, in the wet or dry condition, and without friction on a horizontal plane surface, under an extension of 20 newtons. The length so measured shall be equal, within the limits of maximum permissible errors, to the nominal length of the tape measure. 4. Materlal (a) The materials used shall be adequately strong, stable and resistant to atmospheric conditions under the normal conditions of use and shall comply with the following requirements :- (I) When ordinarilyused at temperatures between ± 8°C of the reference temperature, the variation in length of the tape measure shall not exceed the maximum permissible error. (II) When used with a change of± 10 per cent in the tension, the variation In length of the tape measure shall not exceed the maximum permissible error. (b) Tilpe measures of nominal length O.Sm to Sm: (I) The tape measure may be made from a suitable fabric or plastic material. (II) The fabric shall be coated with suitable paints, enamels or other suitable coating so as to give the tape measure a good finish. All coatings shall be non-cracking and water resistant. (c) Tape measure of nominal length above Sm: (i) If made from fabrics, the fabric may be reinforced length-wise with rust­ proof and rigid wires of metal or other equivalentmaterial. • j_ ·-- 368 THE GAZETTE OF INDIA: EXTRAORDINARY [PARTll-SEC. 3(i)] (ii) If-made-from ·plastic materials, the tape measure shall be reinforced length-wise .by rneans of rust-proof and rigidwires of metal or glass fiber. (iii) If made from any other material, the tape measure shall satisfy the condltlonsspecified in clause 4(a). 5. Manufacture (a) General.; (i) Tape measures shall be well-made, . robust and carefully finished. (ii) 'The cross-section of the tape measures shall have such dimensions and shape that, under normal conditions of use it allows the tape measure to have the accuracy specified for its class. (iii) Tape measures shall be so made that when they are stretched over a plane surface their edges are practically straight and parallel. (iv) The rings, winding, devices or other devices shall be attached to the tape in such a manner that they do not cause any inaccuracy or permanent defonmatlon in the tape. (b) Tape meesores of nominal length O.Sm to Sm: (i) Tape measures of nominal length O.Sm to Sm shall have a width of not less than 5mm and not more than 25 .mm. (ii) If not wound on a spool or In a case, both the ends of the tape measure shall be reinforced with plastic or metal strips, of the same width as the tape measure, over a length of not less than 10mm or more than 100mm. (iii) If wound on a spool or In a case, the tape measure shall have a metal ring or other device securely attached to the outer end of the tape measure. A device, retraction or winding of the tape shall be provided. (c) lape measure of nominal length above Sm : (i) The tape measures shall have a width of not less than 10 mm and a thickness between 0.3 and 0.6 mm. (ii) A metal ring shall be securely attached to the outer end of each tape measure. The ring shall be securely fastened to the tape measure by a metal strip of the same width as the tape. (iii) The outer end of the tape measure shall be reinforced over a length of not less than 100 mm by a strip of leather or other suitable material of the same width as the tape measure. The strip shall pass round the inner end of the ring and under the metal strip . Note :This strip, besides serving as a protective device shall also be utilised for affixing the stamp of verification. (iv) The tape measure shall be rolled into a suitable container or wound on a windingdevice made of metal, plastic, leather or other suitable material. 6. Graduations (a) General requirements : (i) Graduation lines shall be clear, uniform, indelible and so made as to ensure easy and unambiguous reading. (ii) The value of the graduations shall be of the form 1 X 10",2 X 10' OT 5 X 10", the exponent "n" being positive or negative whole number or zero. The value of the graduation, however,shall not exceed: 1 cm, on measures of nominal length less than or equal to 2m, 10 cm, on measures of nominal length more than 2 m, but less than 10 m, 20 cm, on measures of nominal length more than 10 m, but less than SOm, 50 cm, on measures of nominal length equal to or more than 50 m. (Ill) Graduation lines shall be reasonably straight, perpendicular to the axis of the tape measures and of uniform thickness throughout the length. (Iv) Graduations lines shall be so made that they form a clear and distinct scale and their thickness does not cause any inaccuracy of reading. (b) Tape measures of nominal length 0.5 m to Sm: (i) The zero graduation line may be located at the outer end of the ring or 369 other device or may commence on the tape itself at a length equal to or greater than 50 mm from the outer end of the ring or other device. (ii) The tape measures may be graduated throughout at every millimetre or every5mm. ). (iii) The graduation lines at every10 mm shall be marked in such a manner that there is. no confusion between the 10 mm lines and the millimetre or 5 mm lines. (iv) The tape measures may be graduated on one side or both the sides. If the tape is graduated on one side, the manufacturer's name, trade mark, advertisement or other similar matter may be printed on the ungraduated side of the tape measure. (c) Iepe measures of nominal length above Sm: (i) The zero graduation line may be located at the outer end of the metal ring or on the tape itself, at a length equal to or greater than 100 mm from the outer end of the ring. (ii) The tape measure may be graduated at e;ery millimetre, every 5 millimetre or every 10 millimetre. (iii) The graduation lines at every 10 mm shall be marked in such a manner that there is no confusion between the 10 mm graduation lines and the millimetre or 5 mm graduation line. (iv} The graduation lines at every 10 m shall have a length approximately half the width of the tape. (v) Every graduation line at 50 mm shall have the same length as the graduation line at 10 mm but may have an arrow at Its end. This requirement shall not apply to tape measures graduated at every millimetre. (vi) The zero grad·uatlon line, the graduation lines at every 100 millimetres and at every metre shall have a length equal to the width of the tape. 7. Numbering (a} General requirements : (i) The numerals shall be indicated clearly, uniformly and indelibly and shall be easily and unambiguously legible. (ii) The places, dimensions, shape, colour and contrast of the numerals shall be suitable for the scale and graduation lines to which they relate. (Ill) The numerals shall be marked parallel to or perpendicular to the axis of the tape measure depending upon the intended manner of use of the measure. (b) On tape measures of nominal length 0.5 m to Sm: (I) Every graduation line at 10 mm shall be marked with the complete number of centimetre. Explanation :The graduation number marked may be, for example 122 and not. 22 after completion of one metre. (ii) The heightofthe numerals shall not exceed two-thirds the width of the tape measures. (c) On tape measures of nominal length above 5m: r: ,c (i) The graduation lines at every 100 mm and at every metre shall be numbered. The numerals shall have a height of not more than two-thirds of the width of the tape. (II) the metre graduations shall be accompanied by the symbol 'rn' and, if required,' tll' Note: The abbreviation 'tll' may be indicated In the regionalscript. (Ill) After the graduation line at one metre, every graduation line at 100 mm may be marked with an additional numeral indicating the completed number of metres. This numerals, if provided, may be located just above, below or in line with the numeral of the 100 mm graduation line. The height of the numeral may be approximately half the height of the numerals indicating 100 mm. 8. Maximum pennissible error (I) On verification, under the conditions specified in clause 2, the error on the length .L / 370 ·,THEfGAZETTE:Of INDIA: EXTRAORDINARY .. [PARTII-SEC. 3(i)] between.the axis of any twqgrai:luation:lines shall notexc-eed : ... · '>"., .. · for oesst ;±:'(0:1-.+:0,ll) mm; for Class.II ±:(0:3-:+:0.21:}mm;and for Class III £(0;6 :+,OAL:),mm;' Where'.L•tsithe·lerigth ·between the two graduation lines .concerned, expressed in metres;rounded.off.tothe·next higher whole number. of metres. (ii) The maximum iperrnisslbte error on tape · measures on:lnspection shall be twice that specified .for werification, the methods of verification.remaining .unchanged. (iii) Tape measure of .nominal length 0.5 m to 5 m shall·belongto accuracy aass II or Class m. (iv) Tape .measures of nominal length above 5 m shall belong to accuracy Class I, Class II or Class HI. · 9. Marldngs . (a) Tape measures of nominal length 0.5 m to Sm: The tape measures and the case or container, if provided shall be marked at a suitable place with the following markings : (i) nominal length in metres. (ii) manufacturer's name or trade mark or both. (iii} class of accuracy II or III In an oval. (iV} an Indication of the location of zero on the scale. (v) model approval number Issued by the · Central Government .. (b) Tape measure of nominal length above Sm: · The tape measure and the case or container or other device, where provided shall be marked near the zero graduation line and on the container, case or other device with the following markings :- (i) nominal length in metres. (ii) manufacturer's name or trade mark or both.· (iii) class of accuracy : I, II or III in an oval. (iV) an indication of. the location of zero on the scale.» · ,· ? , (v) model approval number Issued by the Central Government. (c) The inscription shall be clearly visible and legible. ,' ., . ,,, . ·.\'":::.-: (d) Advertising inscriptions, if made, shall be carried out of such a manner that they did not Intrude in any way with the use of the tape measure. 10. Sea/Ing The stamp of verification shall be affixed on the metal, plastic, leather or other strip provided at the beqlnnlnqof the tape measure. PART VII-5TEEL TAPE MEASURES 1. General This Part deals with steel tape measures which are used for measurements where the use of rigid length measures is not convenient or practicable .. 2. Classes of accuracy Steel tape measures shall be divided into three classes, namely, Class I, Class II and Class III, In accordance with their accuracy. 3. Nomlna/lengths The tape measures shall be made in nominal lengths of 0.5 rn, 1 m, 1.5 m, 2 m, 3 m, 4 m, 5 m or multiples of 5 m, provided that the maximum nominal length not exceed 200m. Note : The nominal length of a steel tape measure Is the distance at the reference temperature of± zooc, between the initial and terminal graduation lines, when the tape measure is stretched, without friction, on a horizontal plane surface, under a tension of 50 newtons. The length so measured shall be equal, within the limits of maximum permissible errors, to the nominal length of the tape measures. 4. Materials (a) The materials used shall be adequately strong, stable and resistant to environmental influences under normal conditions of use and shall comply with the following requirements : (I) when ordinarily used at temperatures between ± 10°C of the reference temperature, variation in length of the tape measure shall not exceed the maximum permissible error; (Ii} when used with a change of± 10% in the tensions, the variation in length of the tape measure shall not exceed the maximum permissible error. (b) The tape measure shall be made from steel or stainless steel. 5. Manufacture (a) Tape measures shall be well made, robust and carefully finished. (See Figure 22 to 26). (b) The cross section of the tape measures shall . - - -··--.- .--. ?--·- -- ['WTII ?3(i)J 371 have such dimensions and shape that, under normal conditions of use, it allows the tape measures to have the accuracy specified for its class. Note : It ts recommended for guidance of manufacturer and users that tape measure may have a width of not less than 5 mm and a maximum thickness of 0.4 mm. (c) The steel tape measure sha II be so made that when It Is stretched on a plane surface, the edges are practicallystraight and parallel. (d) At the zero end, tape measures shall be provided, with a ring or other device for facilitating withdrawal. The ring or other device, when provided, shall be fastened to the tape measure by a metal strip of the same width as the tape. (e) The tape measures shall be capable of being wound Into suitable container or other winding device of robust construction and made of metal, plastic, leather or other suitable material. (f) The winding devices shall be so designed that they do not cause any Inaccuracy or permanent deformation in the tape. (g) The edges of tape measures shall be slightly rounded. (h) The tape measure shall be provided with rust proof coating and shall be free from burrs. 6. Graduations (a) General requirements (i) Graduation lines shall be clear, uniform, indelible and so made as to ensure easy and unambiguous reading. (ii) The value of the graduations shall be of the form 1 x 10", 2 x 10" or 5 x 10" metre where the exponent 'n' being a positive or negative whole number or zero. The value of the graduations, however, shall not exceed : 1 cm, on measures of nominal length less than or equal to 2 rn, 10 cm, on measures of nominal length more than 2 m but less than 10 rn, - 20cm, on measures of nominal length more than 10 m, but less than 50 m, 50 cm, on measures of nominal length equal to or more than 50 m. (iii) Graduation lines shall be reasonably straight, perpendicular to the axis of the tape measure, and of uniform thickness throughout their length. (iv) Graduation lines shaD be so made that they form a clear and distinct scale and that their thickness does not cause any inaccuracy of reading. (b) Tape measures above 5 m to 200 m shall be graduated only on one side. Tape measures of 0.5 m to 5 m may be graduated on both sides (Only metric scale). (c) The graduated lines, numbers and other markings shall be either in relief, engraved, typographically printed or made in any other suitable manner. (d) The zero of the scale may be located at the outer or inner edge of the ring or other device, or may also be located on the tape measure itself, ata length equal to or greater than: (I) 50 mm from the outer end of the ring or other device, in the case of tape measures of nominal length 0.5 m to 5 m; and (II) 100 mm from the outer end of the ring or other device,- in the case of tape measures of nominal lengths aboves m. '.' (e) Tape measure of denominationsO.Sm to Sm may be graduated throughout at every millimetre, every 5 millimetre or every 10 millimetre. (i) The graduation lines at every 10mm shall be marked In such a manner that there is no confusion between the 100 mm graduation lines and the millimetre or 5 mm graduation lines. (II} In the case of tape measures graduated at every 5 mm or 10 mm, not less than the first 100 mm shall be subdivided into millimetre. (f) In the case of tape measures of nominal length above 5 m, every graduation line at 50 mm shall have the same length as the graduation line at 10 mm but may have an arrow at its end. This requirement shall not apply to tape measures graduated at every millimetre. (g) The thickness of the graduation lines shall not exceed the following limits : 0.4 mm in the case of Class I and Class II tape measures, and 0.5 mm In the case of Class III tape measures. (h) In the case of tape measures of nominal length 0.5 m to· 5 m, the graduation lines 372 lTHE•_GAZEITE OF INDIA: EXTRAORDINARY [PARTII-SEC. 3(i)] ? I H 'I I t I I END OF MEASURE FIGURE-22 MEASURE WITH ZERO AWAY FROM RING . FIGURE-23 l111111111l11111mrl?111r EXAMPLES OF GRADUATIOIII LINES AND NUMERING FIGURE. 24 i r81f912f,f11r, Fit, F, r, F, r, F13f ? 18I 19I21°I 11I 12I 13I 14I 15I 16I j7 I 18I l9I31° 1x1d' · ............ 1 .....__.__.1__,_I ?_..__.__. I . sx10" , 1, 1, 1j,, 1,,, 1, 1, 1, 1,I .. 21 20 19 18 17 . IU.USTRATION OF A MEASURE COMMENCING WITH ZERO FIGURE25 ------- ---L 373 fOOmm . ;, u u " " " . " ? 0" ••.. 'r : : I"') 0 10 ,> . ). 14m 1 0 IU.USTRA1l0NOFLONGMEASUREOFFABRICORGLASSFIBREANDCONTAINER FIGURE-26 374 THE GAZETTE OF !NDIA:EXTRAORDINARY [PARrll-SEC. 3(i)] may have a length between one-fourth and full width of the tape, depending upon convenience. In the case of tape measures of nominal length above 5 m, the length of the graduation lines may 'be as follows :- {i) for millimetre graduation lines, about one-third of the width of the tape; (ii) for 5 millimetre graduation lines, .about half the width of the tape; (iii) Jor :10 :millimetre graduation lines, ,about.two-thirds the width of the tape; .and (iv) ,for lOOmillimetre graduation lines and ,for metre graduation lines as well as ,for the zero graduation lines, equal :to the width of the tape. 7. Numbering (a) General requirements : (i) The numerals shall be Indicated clearly, uniformly and Indelibly and shall be easily and unambiguously legible. (ii) Toe places, dimensions, shape, colour and contrast of the numerals shall be suitable for the scale and graduation lines to which they relate. (iii) The numerals shall be marked parallel to or perpendicular to the axis of the tape measure depending upon the Intended manner of use of the measure. (b) The following graduation lines shall be numbered: 10 mm, for tape measure of nominal length 0.5 to S m, 100 mm for tape measure of nominal length exceeding 5 m. (c) The metre graduation lines shall be numbered and accompanied by the symbol 'm' and if required "ifi" Note : The abbreviation ">ii" may be indicated In the regional script. (d) In the case of the tape measure of nominal length of 0.5 m to 5 m, the height of the numerals shall be such as would facilitate the reading of the measurement without ambiguity. · (e) In the case of tape measures of nominal length 5 m and above, after the graduation line at one metre, every graduation line at 100 mm may be marked with an additional numeral indicating the completed number of metres. This numeral, if provided, may be located just above or in line with the numeral of the 100 mm graduation line. The heightof this numeral may be approximately half the height of the numerals indicating 100mm. · (f) In the case of tape measures of nominal length 5 m and above the height of the numerals, except those given in sub-clause (e) of clause 7 may be: (i) about 1/3 of the width of the tape, for 10 mm graduation lines, (ii) about 1/2 of the width of the tape, for 100 mm graduation lines, and (Iii} about 2/3 of the width of the tape, for metre graduation lines. (g) If tapes of 0.5 m to 5 m are contained In special container may be marked with Its dimension, for example, SO mm, to facilitate measurement of internal dimensions. 8. Maximum permissible error (a) On verification, under the conditions specified in clause 2, the error on the length between the axis of any two graduation lines shall not exceed : for Class I± (0.1 + O.ll) mm, for Class II± (0.3 + 0.2L) mm, and for Class III± (0.6 + 0.4L) mm, where Lis length between two graduation lines concerned, expressed in metres, rounded off to the next higher whole number of metres. (b) The maximum permissible error on tape measures on inspection shall be twice that specified for verification, the method of verification remaining unchanged. (c) Steel tape measures of nominal length 0.5 m to 5 m shall belong to accuracy Class I or Class II. (d) Tope measures of nominal length above 5 m shall belong to accuracy Class I, Class II or Class III. ----- --- 375 2. Definitions (a) Surveying chain+An instrument for measuring the surface distance between two points. (b) Length of chain-The distance between the outside edges of the handles when fully stretched. (c) Tallies-Metallic tags or indicators of distinctive pattern fixed at (various points) of the chain, to facilitate quick reading of fractions of a chain. 3. Material The different components of the chains shall be made from the materials mentioned against each. 9. Markings (a) The steel tape measures shall be marked at a suitable place near the end and on the container, where provided with the following markings: (i) nominal length in metre, (ii) an Indication of the location of the zero of the scale, .. (iii) the manufacturer's name or trade - mark or both, (iv) class of accuracy : I, II or III in an oval, (v) model approval number issued by the Central Government. (b) The inscriptions shall be clearly visible and legible. · (c) Advertising inscriptions, if made, shall be carried out in such a manner that they do not intrude in any way with the use of the tape measure. 10, Sealing · The stamp of verification shall be affixed on the metal, plastic, leather or other strip provided at the beginning of the tape measure. Components Handle Eye Bolt Collar Ring Link, Small Link, Large Link, Connecting Tally Indicating ring Material Brass castings Brass suitable for free cutting and high speed machine work Galvanised mild steel wire 4mm. Brass sheet or galvanized sheet Brass wire PARTVIII•SURVMNGCHAINS 1. General This Part deals with link type surveying chains of 20 m and 30 m lengths for land measurement. 4. Constructional details (a) The nomenclature of the different parts of the chain and their dimensions shall be as Indicated in Figure 27, 28 & 29. (b) The tallies shall be fixed at every fifth metre fi------ ··---+--1··r ·· I ·· 1 --ooo--oqo--or--000-0-0 . . \_ BRASS RING AT EVERY METRE LENGTH TALLIES 1-5 TO 2-0 MM THICK 20-METRE CHAIN FIGURE-27 --------------- 376 THE GAZETTE OF INDIA: EXTRAORDINARY [PARTll-----.5EC.J(i)] 1,......-------------som .., IBRASS RING AT EVERY METRE LENGTH -TALLIES 1-5 TO 2·0 MM THICK ENGRAVE 30 m ON.SURFACES A AND B TO INDICATE THE'LENGTH OF·CHAIN A 30-METRECHAIN FIGURE-28 llmt11 UNK.I..AKGE.4.00mm(OR8SWG) ?.OOm,a (OR I SWG) 93ilmai 13? RING HANDLE 6mmDIA Engrave 20 m OR 30 m OM SURFACE INDICATE THE LENGTH OF CHAIN 74+1rn.m NOMENCIJ\lURE AND DETAILS OF 5 m LENGTH ATlliE BEGINNING AND END OF SURVEYJNG CHAIN FIGURE-29 ['1fll II ? 3(i)) 377 Decimetre Full width of the tape Metre Full width of the tape (cl The tape shall be so made that it is capable of being wound on a drum and held In a winding frame or case. (d) The free end of the tape shall be fitted with the dip weight or arrangements provided for attaching the dip weight. 6. Dip weights (al Dip weights shall be of two types, light and heavy, and shall be of cylindrical torpedo shape. The dimensions for light and heavy dip weights shall be as shown in Figure 30. (bl The light type may either be fixed permanently to the tape or attached separately to it by any suitable device. (cl The heavy type shall be attached to the tape by a swivel hook (See Figure 31l. 2. Definitions A dip tape shall mean essentially a graduated steel tape in one continuous length used in conjunction with a dip weight. 3. Denominations The tape shall be of the denominations 5, 10, 15, 20, 25 and 50 metres. 4. Material (a) Tape-The steel used shall have a minimum tensile strength of 1500 M Pa. (bl Dip weights or dip bobs-The dip weights · shall be made of brass or other non-sparking or low sparking material, sufficiently hard to resist damage by contact with steel. 5. Dlptape (al The dip tape shall be of the following dimensions: Width : l3 mm or 16 mm Thickness : Between 0.20 and 0.30 mm · Length : One continuous piece of sufficient length for the purpose required. The tape shall be longer than the distance between the dip reference point and the bottom of the container. (b) Graduations (ll The tape shall be marked legibly and indelibly on one side only with a line at every millimetre or five millimetres, centimetre, decimetre and metre. The height of marking lines shall be as follows: along the chain. Small rings shall be fixed at every metre, except where tallies are attached. Thllles shall have distinctive shapes depending on their position in the chain as . shown In Figure 27 and 28. (c) Connecting links between two large links shall be oval In shape, the central one being a circular ring. (d) To faciUtate holding the arrows (chain pains) in position with the handle of the chain, a groove shall be cut on the outside surface of the handle as shown in Figure 29. The radius of the groove shall correspond to the radius of the arrows. (el The handle joint shall have flexibilityin order that It may be possible to swivel the handle round the eye bolt. A swivel may also be provided at the middle of the chain. 5. Permissible error (a) When measured with a tension of 80 newtons every metre length shall be correct with an error not exceeding± 2 mm. The overall length of the chains shall be correct within the following limits of error : 20 metre chains± 5mm 30 metre chains ± 8 mm (b) The permissible errors shall be the same for verification and inspection. Explanation : Nominal distance between the centres of the circular links containing the small rings or tallies shall define the distance. 6. Marking (a) The tallies used for marking the distances in chain shall be marked with letters ',:ft' and 'm' (See Figure 29). (b) The length of the chain, 20 m or 30 m, as the case may be, shall be indelibly marked over the handle (See Figure 29l, (c) The chains shall be indeliblymarked, on the reverse side of the surface of the handle having the denominations with the manufacturer's name or trade mark. Note : The abbreviation .it may be Indicated in the regional script. 7, Provision for stamping A metal label or disc shall be permanently attached to the handled at the beginning of each chain for the verification of stamp. PARTIX-TAPESFORUSEINMEASUREMENTOF OR.QUANTITIES 1. General This Part covers the requirements of tape with the dip weight attached to it and to be used In gauging petroleum, petroleum products and other oils. · Unit of graduation Millimetre Five millimetres Centimetre Approximate height of graduaffon mm 4 6 8 - .... ?- 378 ·rHE GAZETTE OF INDIA: EXTRAORDINARY [PARTIl--SEC. 3(i)] 3 35 7t05 150 DETAIi. Of HOLE 130 3S ,so ---lll--.....j ----•U---...i (LightType} (HeavyType) All dimensions in millimetres UGHT AND HEAVY DIP WEIGHT FIGURE-30 ['<11'1II-? 3(i)] 0 379 / I \ I I \ I I \ L--:--? I I I I I I I I I I I I I I I I I 1 I I I I I I I I I I I I I I 1---1--? \ I I \ I I \ I I \ I I \-'-' 300t0.5rnm SWIVEL HOOK ATTACHMENT FIGURE-31 380 'THE GAZETTE OF INDIA: EXTRAORDINARY (PARTII-SEC. 3(i)] Light Heavy (d) The dip weight shall'have the lengths of graduation and weights given below : denominations shall be legibly marked. In addition, direction of winding shall also be leglbly marked on the case or reel. Suitable provisions shall be made for LegalMetrologyOfficer's stamps on the dip weight and the tape. (c) Every dip weight and dip tape shall be suitably marked to identify them with each other, Note : The word 'tim' and abbreviation 'l!\' may be Indicated in the regional script. SEVENTH SCHEDULE· HEADING· A [See Rule 13J SPECJflCATION FOR NON-AUTOMATIC WEIGHING INSTRUMENTS PART I TERMlNOl.OGY · 1. General definitions (1) Weighing instrument Measuring instrument that serves to determine the mass of a body by using the action of gravity on this body. The Instrument may also be used to determine other quantities, magnitudes, parameters or characteristics related to mass. Accordingto its method of operation, a weighing instrument Is classified as an automatic or non­ automatic Instrument. (2) Non-automatic weighing instrument Instrument that requires the intervention of an operator du?ing the weighing process, for example to deposit on or remove from the receptor, the load to be measured and also to obtain the result. The Instrument permits direct observation of the weighing results, either displayed or printed; both possibilities are covered by the word "indication". Note : Terms such as "Indicate", "indicating component" and their derivatives do not include printing, A non-automatic weighing instrument may be -graduated or non-graduated, -self-Indicating, semi-self-indicatingor non-self Indicating. Note : In this specification, a non-automatic weighing Instrument is called an "instrument". (i) Graduated instrument Instrument allowing the direct reading of the complete or partial weighing result. (II) Self-indicating instrument Instrument in which the position of ±0.4 mm ±0,6 mm ± 1.0 mm ± 1.0 mm for the first five metres plus 0.5 mm for each addl- tlonal five metres or part thereof subject toa maximum error of 2.0mm. Not more than± 0.4 mm (I) One metre mark (ii) Two metre mark (iii) Five metre mark (iv) My metre mark beyond the first five metres (b) Between any two adjoining decimetre and metre lines (c) From zero to the points specified below: Length of graduations 150,mm 150 mm from bottom weight 700 + 50 g 1500 + 50 g (e) The dlp weight shall .be graduated in a manner similar to .the tape. (f) The graduations on the dip weight shall begln:from.its,bottomand shall be carried over.lnsuch a manner that when the dip weight Is attached to the tape the graduations are continuous from the weightto the tape. 7. Permissible error The error in the length of the tape supported on horizontal surface with a tension of 50 newtons shall not exceed the followinglimits : (a) Between any two Not more adjoining mm and cm than ± 0.2 mm lines 8. Marking (a) Every centimetre, decimetre and metre shall be marked with International form of Indian numerals. The decimetre and metre numerals shall be In bold type. The metre divisions shall, in addition, bear the designation •'tjj' or 'rn' or both. The end of the tape measure shall be marked with word '"ITll:' or 'metre' or both. (b) On the ungraduated side and on the case of each tape and also on the dip weight, the name or trade-mark of the manufacturer and the 381 equilibrium rs obtained without the intervention of an operator. (iii) Semi-self Indicating instrument Instrument with a self-indication weighing range, In which the operator Intervenes to alter the lfmits of this range. (iv) Electronic instrument Instrument equipped with electronic devices. (v) Instrument with price scales Instrument that indicates the price to pay by means of price charts or scales related to a range of unit prices. (vi) Price computing instrument Instrument that calculates the price to pay on the basis of the indicated mass and the unit price. (vii) Price-label/Ing instrument / Price computing instrument that prints the weight value, unit price and price to pay for pre-packages. (viii) Self-service Instrument Instrument that is intended to be operated by the customer. (3) Indication provided by an instrument (i) Printing indication Indication, signals and symbols that are subject to requirements of this specification (ii) Indication, signals and symbols that are not primary indications. 2. Construction of an Instrument In .thls specification the term "device" Is used for any means by which a specific function is performed, irrespective of the physical realization, e.g. by a mechanism or a key initiating an operation; the device may be a small part or a major portion of an instrument: · {1) Main device (i) Load receptor or pan Part of the Instrument intended to receive the load. (ii) Load transmitting device Part of the Instrument for transmitting the force produced by the load acting on the load receptor, to the load-measuring device. (iii) Load-measuring device Part of the Instrument for measuring the mass of the load bymeans of an equilibrium device for balancing the force coming from the load transmitting device, and an Indicating or printingdevice. (2}Module Part of an instrument which performs a specific function, can be examined separately and Is subject to specified partial error limits. (3) Electronic parts (i) Electronicdevice A device employingelectronic subassembly and performing a specific function. An electronic device Is usually manufactured as a separate unltand can be independently tested. Note : An electronic device, as defined above, may be a complete instrument (e.g. Instrument for direct sales to the public) or parts of an Instrument (e.g. printer, Indicator). (ii) Electronic sub-assembty A part of an electronic device, employing electronic components and having a recognizable function of its own. (e.g. AID converter, display matrix). (Ill) Electronlccomponent The smallest physical entity that uses electron or hole conduction in semi· conductors, gases or In a vacuum. (4) indication device (of a weighing instrument) Part of the load measuring device on which the direct reading of the result is obtained. (i) Indicating component Component indicating the equilibrium and/ or the result on an instrument with one position of equilibrium it indicate only the equilibrium (so-called zero). On an instrument with several positions of equilibrium it indicates both the equilibrium and the result. On an electronic instrument, this is the display. (11)Scafe mark A line or other mark on an indicating component corresponding to a specified value of mass. (Ill) Scale base An Imaginary line though the centres of all the shortest scale marks. -- - - -·- - -- -------c========-=:J_:..::·===--==========?- 382 THE GAZETTE OF INDIA: EXTRAORDINARY [PARrJI-SEC.3(i)) (5) Auxiliary indicatingdevices (i) Device for Interpolationof reading(Vernier) Device connected.to the:indicating element and sub-dividing the scale of an instrument, without special adjustment. (ii) Complementary indicating device Adjustable device by means of which it is possible re estimate, .in units of mass, the value corresponding to the distance between a scale mark and the Indicating component, (iii) Indla,tfng device with a differentiated scale. division Digital .Indicatingdevice of which the last figure after the decimal sign Is clearly differentiated from other figures. (6) Extended indicating device A device temporarily changing the actual scale interval (d) to a value less than the verification scale interval (e) following a manual command. (7) Supplementary devices (i) Levelling device Device for setting an instrument to its reference position. (ii) Zero setting device Device for setting the indication to zero when there Is no load on the load receptor. (a) Non automatic zero setting device Device for setting the Indication to zero by an operator. (b) Semi automatic zero setting device Device for setting the Indication to zero automatically following a manual control. (c) Automatic zero-setting device Device for setting the Indication to zero automatically without the intervention of an operator. (d) Initial zero-setting device Device for setting the Indication to zero automatically at the time the lnstrumenfis switched on and before it is ready for use. (iii) Zero tracking device Device for maintaining the zero Indication within certain limits automatically. (iv) Tare device Device for setting the indication to zero when a load is on the load receptor; without altering the weighing range for net loads (additive tare device); or reducing the weighing range for net loads· (subtractive tare device). It may function as: a non-automatic devices {load balanced by an operator); a semi-automatic device {load balanced automatically following a single manual command); an automatic device {load balanced automatically without the intervention of an operator). (a) Tare balancing device: Tare device without indication of the tare value when the instrument is loaded. {b) Tare weighing device: Tare device that stores the tare value and Is capable of indicating or printing it whether or not the instrument Is loaded. (v) Preset tare device Device for subtracting a preset tare value from a gross or net weight value and Indicating the result of the calculation. The weighing range for net loads is reduced accordingly, (vi) locking device Device for immobilizing all or part of the mechanism of an instrument. (vii) Auxiliary verification device Device permitting separate verification of one or more main devices of an Instrument. (viii) Selection device for load receptors and load measuring devices Devices for attaching one or more load receptors to one or more load measuring devices, whatever intermediate load transmitting device are used. (Ix) Indication stabilizing device Device for maintaining a stable indication under given conditions. 3. Metrologica/ characteristics of an instrument (1) Weighing capacity (Max) (I) Maximum weighing capacity, not taking Into account the additive tare capacity. [ '1llT II -'€i1>'s 3 ( i) ] ------·-- - --· 383 (ii) Minimumcapacity(Min) Value of the load below which the weighing results may be subject to an excessive relative error. (iii) Self-indication eapacity Weighing capacity within which equilibrium is obtained without the intervention of an operator. (iv) Weighingrange Range between the minimum and maximum capacities. (v) Extension lnteival of self-lndieatlon Value by which it is possible to extend the range of self-Indication within the weighing range. (vi) Maximum tare effect (T = + ... , T = · ... ) Maximum capacity of the additive tare device or the subtractive tare device. (vii) Maximum safe load (Lim) Maximum static load that can be carried by the Instrument without permanently altering Its metrological qualities. (2) Scale divisions (i) Scale spacing (Instrument with analogue indication) Distance between any two consecutive scale marks, measured along the scale base. (Ii) Actual scale interval (d) Value expressed in units of mass of,­ the difference between the values corresponding to two consecutive scale marks, for analogue indication, or the difference between two consecutive indicated values, for digital Indication. (iii) Verification scale interval (e) Value expressed in units of mass, used for the classlflcations and verification of an instrument. (iv) Scale inteival of numbering Value of the difference between two consecutive numbered scale marks. (v) Number of verification scale intervals (single lnteival instrument) Quotient of the maximum capacity and the verification scale interval: n= Max/e (vi) Multi-inteival instrument Instrument having one weighing range which is divided Into partial weighing ranges each with different scale intervals, with the weighing range determined automatically according to the load applied, both on Increasing and decreasing loads. (vii) Multiple range Instrument Instrument having two or more weighing ranges with different maximum capacities and different scale intervals for the same load receptor, each range extending from zero to its maximum capacity. 4. Metro/09/cal properties of an instrument (1) Discrimination Ability of an instrument to react to small variation of load. The discrimination threshold, for a given load, is the value of the smallest additional load that, when gently deposited on or removed from the load receptor causes a perceptible change In the indication. (2) Repeatability Abilityof an instrument to provide results that agree one with the other when the same load is deposited several times and In a practically identr ;al way on the load receptor under reasonably constant test conditions. (J) Durability Ability of an instrument to maintain Its performance characteristics over a period of use. (4) Warm-up time The time between the moment power Is applied to an instrument and the moment at which the instrument is capable of complying with requirements. ' 5. Indications and errors (1) Methods of tndtcstion (/) Balancing by weights: Value of metrological controlled weights that balance the load (taking into account the reduction ratio of the load). (II) Analogue tndtcsdon: Indication enabling the evaluation of the equilibrium position to a fraction of the scale interval. 384 ,TFIB."GAZE'fTE ·OF INDIA: EXTRAORDINARY · [PARTII-SEC. 3(i)] (iii) Digital Indication : Indication ·Jn .. which· the scale marks are composed of a sequence of aligned figures thatxdo, notpermit interpolation to fractions of the scale interval. (2) Weighingresults Note: The followingdefinitions·apply,only when the Indication has-been.zero 'before the loadnes been.applied ·to:the .lnstrument. {i) Gross. va/ue;{(i):: Indlcation,oflthe weight ·of a load on an instr.ument, ·with .no .tare or preset tare device· ln.opereton, (ii) Net,value:(N): Indication of the weight of a load on an instrument after operation of a tare devfce. (iii) rare ,v;;lue (T) : The weight value of a load, determined by a tare weighing device. {J) Other weight values (i) Preset tare value {PT) : Numerical value, representing a weight that is Introduced into the Instrument. "Introduced" includes such as keying in, recalling from a data storage, or Inserting via an interface. (ii) calculated net value: Value of the difference between a gross or net weight value and a preset tare value. (iii) calculated total weight value : Calculated sum of more than one weight value and/or calculated net value. (4)Reading (i) Reading by simple juxtaposition Reading of the weighing result by simple juxtaposition of consecutive figures giving the weighing result, without the need of calculation. {ii) Overall Inaccuracy of reading The overall Inaccuracy of reading of an instrument with analogindication Is equal to the standard deviation of the same Indication, the reading of which is carried out under normal conditions of use by several observers. It Is customary to make at least ten readings of the results. (ill} Rounding error of digital indication Difference between the indication and the result the instrument would give with analog indication. (Iv) Minimum reading distance The shortest distance that an observer Is able to freely approach the indicting device to take a reading under normal conditions of use. This approach is considered to be free for the observer if there is a clear space of at least0.8 min front of the indicting device. {See figure 32 A) The Minimum read· ing distance is S; However, if S < 0.8 Indicating device m. the minimum reading distance is L. Platform FIGURE- 32A (5) Errors (See Figure 32 B for illustration of certain terms used) -------- ['WT II-? 3(i)] " " r- - -- - ----- - - - - I I I r-r - - - - - - - - - - - - - J 385 £, -- --·--- c, .. .. : . .,. '; -- _-_- , - ... <.f I -- --- -- -- --- c, ?.,,,;"" - _-_-___ .. -- , i.--??-=-:--?--???-.J5r-:::::::::::,???--i? ''· . - - . +--,-------+-- Mn, ' 2t L. - .. - --- .. - - - - - - - -, 2 .. FIGURE·32B Illustration of certain terms used M = mass to be measured E = error of indication MPE1=maximum permissible error on verification MPEz=maxlmumpermissible error in servlce (inspection) C = characteristic under reference conditions C 1 = characteristic due to influence factor or disturbance Cz =characteristic after durability tests I, = intrinsic DE= durability error Situation 1 : Shows the error E1 of an instrument due to an influence factor or a disturbance, !1 is the intrinsic error. The fault due to the influence factor or disturbance applied equals E1 minus Ii. Situation 2: Shows the error E2 of an instru­ ment after the durability test. 12is the Initial Intrinsic error. The durability error equals E2 minus 12. (I) Error (of Indication) The indication of an instrument minus the (conventional) true value of the mass. (ii) Intrinsic error The error of an instrument under reference conditions. (iii) Initial intrinsic error The intrinsic error of an instrument as determined prior to the performance arid span stability tests. 1 Mn, ...._ - - - - - - - - - - - (iV) Maximumpermissible error Maximum difference, positive or negative, allowed by regulation between the Indication of an Instrument and the corresponding true value, as determined by reference standard masses, with the Instrument beingat zero at no-load, in the reference position. (v) Fault The difference between the error or Indication and the Intrinsic error of an Instrument. Note: Principally, a fault Is the result of an undesired change of data contained in or flowing through an electronic instrument. (vi) Significant fault A fault greater than e. Note: For a rnulti-intervel instrument, the value of e is that appropriate to the partial weighing range. The following are not considered to be significant faults, even when they exceed e: • Faults arising from simultaneous and mutually independent causes in the Instrument. • Faults implying the impossibility to perform any measurement. • Faults being so serious that they are bound to be noticed. by alt those interested in the result of measurement. ·--?--- -- ?---- . --? --1?- ? --- 386 ,THE GAZETTE OF. INDIA: EXTRAORDINARY [PARTII-SEC. 3(i)] o Transltory'faults+belnq -momentarv variations in the indication which cannot be ··Interpreted, . memorized or transmitted as a measuring·result. (vii) Durab17/tyerror The difference between:.the intrinsic error over a:pertod of use and the·initial intrinsic error of..an Instrument. (viii) Significant durab17ityerror A durabltity,error:greater .than e: Note J: A durab!llty,error can:be due.tornechanlcal wear and tear ondue•to,driftand.aging of electronic parts. The concept '.Of •significant·durability error applies only to electronlc,parts. Note 2: For a multHnterval instrument, the value of e is that appropdiateto.the partial weighing range. The followingare not consideredto be significant durability error, .even when they exceed e: Errors ocour:dng.after a perlod of Instrument use that are clearly the result of a failure of a device/ component, or ,d a disturbance and for which the indication : o cannot be Interpreted, memorized, or transmitted as a measurement result/or o implies the impossibility to perform any measurement, or o is so obviously wrong that It Is bound to be noticed by all those interested In the results of measurement.' · (ix} Span stilbllity The capacity of an instrument to maintain the difference between the Indication of weight at maximum capacity and the indication at zero over period of use within specified limits. 6. Influence and reference conditions (1) Influence quantity A quantity that is not the subject of the measurement but which influences the values of the measure and or the Indication of the Instrument. (i) Influence factor An Influence quantity having a value within . the specified rated operating conditions of the Instrument. (ii) Disturbance An influence quantity having a value within the limits specified in this specification but outside the specified rated operating conditions of the instrument. (2} Rated operating conditions Conditions of use, giving the range of values of influence quantities for which the metrologlcal characteristics are intended to lie within the specified maximum permissible errors. (3) Reference conditions A set of specifiedvalues of influence factors fixed to ensure valid inter-comparison of the results of measurements. (4) Reference position Position of the instrument at which its operation is adjusted. 7. Performance test A test to verify whether the equipment under test (EUT) is capable of performing its intended functions. PART II NON-AllT'OMAllCWEIGHING INSTRUMENTS J. Scope. This specification specifiesthe metrological and technical requirements for non-automatic weighing instruments and will not be applicable to the following non-graduated instruments : (1) Beam scale (2) Counter machine 2. Prlndples/nvolved (1) Units of measurement (i) The units of mass to be used on an instrument shall be the kilogram (kg) the milligram (mg), .the gram (g) and tonne . (t). (ii) For special application e.g. trade with precious stones, the metric carat (1 carat = 0.2 g) may be used as unit of measurement. A symbol for the carat shall be\\c". (2) Metrolog/calrequirements The requirements apply to all instruments irrespective of their principles of measurement. Instruments are dassified according ta: o the verification scale interval, e the number of verification scale intervals. The maximum permissible errors are in the order of magnitude of the verification scale interval. A minimum capacity (Min) is specified to indicate that the Instrument should not be used for measuring loads below that limit. [ '1l'T II -"1lJ116 3 (i ) J 387 (2) Verification scale Interval (i) Verification scale interval shall be in the form 1 X 10k,2 X 10k,5 X 1Qk k being a positive or negative whole number or equal to zero. (ii) The verification scale interval for different types of Instruments shall be as given in Table 16. 3. Metro/oglca/ requirements {I} Principles of classification (i) Accuracy classes The accuracy classes for instrument and their symbols shall be as given in Table 15. TABLE15 (3) Classlfic8tlon of instruments (I) Toe verification scale interval, number of verification scale Intervals and the minimum capacity, in relation to the accuracy class of an instrument, shall be as given in Table 17. e=d Verification scale interval TABLE16 Type of instrument Graduated, without auxiliaryIndicating device Graduated, with auxlllary Indicating device . e is chosen by the manufacturer according t'? requirement in sub­ paragraph (3) and clause (iii}of sub-paragraph (5) of this paragraph. Non-graduated e is chosen by the manufacturer according to sub-paragraph (3) of this paragraph. n I m SymbolOass· Special accuracy Highaccuracy Medium accuracy Ordinary accuracy TABLE17 Accuracy class Verification scale lntervale Number.of verification scale intervals n=Max/e Minimum rapacity may have weighing ranges in classes I and II or in classes II and III. The instrument as a whole shall then comply with the more severe requirements of sub-paragraph (9) o( this paragraph applicable to either of the two classes. (4) Additional requirements for a multi-interval instrument (I) Partial weighing range Each partial range (index i = 1, 2 ... ) shall be defined by: -Its verification scale intervals ei, e,+i > e1 Its maximum capacity Maxi Its minimum capacity Mini=Max(i-1)(for I = 1 the minimum capacity is Mini = Min) minimum Special I O.OOlgse 50 000* Highll 0.001 gs es 0.05 g 100 O.lgse 5000 Medium Ill O.lgses.2g 100 Sgse 500 Ordinary IV 5 g < e 100 Note : For values of 'e' less than 1 mg In respect of class I accuracy instruments, e shall be taken to be equal to 1 mg for the purpose of verification/Inspection. See for exception In clause (v) of sub-paragraph (5) of this paragraph. (ii) On multiple range instruments, If the verification scale intervals are e1, ez .... er­ with ei < ez < ... < e,, Min, n and Max shall be indexed accordingly. ( iii) On multiple range instruments each range shall be treated as an instrument with one range. (iv) For special application that are clearly marked on the instrument, an Instrument maximum 100 000 100 000 10000 10000 1000 lOOe 20 e SOe 20e 20 e 10e 388. THE GAZETTE OF INDIA:EXTRAORD!NARY [PARTCT-SEC. 3(i)] last differentiated figure : 5 d = 0.01 g or 0.05 g 0 e = 0.1 g last differentiated figure : 8 d = 0.01 g or 0.02 g e = 0.1 g d = 0.1 g 0.2 g 0.5 g TABLE19 e= lg lg lg (i) Example of a complementary indicating device(*) (II) examples of indicatingdevices each with a differentiated scale division (**) for an instrument of class I with d< 0.1 mg, n may be less than 50000. (I) Values of maximum permissible errors on vetittcstion/reverlticstton The maximum permissible errors allowed for increasing or decreasing loads shall be as given Table 26. (v) Minimum number of verification scale Intervals Figure 32-C Example of a auxiliaryindicating device (Iv)Minimum capacity The minimum capacity of the instrument Is determined in conformity with the requirements in Table 17. (6) Maximum permissible errors i2 3, 4 I g I I2 3, 4 (I g I TABLE20 IVIllIII The numberotventlcatlonscale intervals n for each partial range is equal to n1 = Maxifei (ii) Accuracy class ei and· ni In each partial·welghing range, and minishall comply with:therequirements given In Table 40 according to the accuracy class of the Instrument. (iii) Maximum capacity ofpartial weighing ranges With ·.the exception of the last partial weighlngr.mge, the.requirements In Table · 18 shallbe complied with, according to the accuracy.class of the instrument. TABLEl.8 Gass Max;fe;+1 > 50 000 > 5 000 > 500 ?. 50 (iv) Instrument with a tare device Requirements concerning the ranges of a multi­ interval instrument apply to the net load, for every possible value of the tare. (5) Auxiliaryindicating devices (i) Typeend appliCation Only Instruments of classes I and II may be fitted with an auxiliaryindicatingdevice, which shall be,- -a device with a rider, or -a device for Interpolation of reading, or -a complementary indicatingdevice (*) or -an Indicatingdevice with a differentiated scale division (**). These devices shall be permitted only to the right of the decimal sign. (ii) A multi-interval instrument shall not be fitted with an auxiliary indicating device. (iii) VerifiCatlon scale interval The verification scale interval e shall be determined by the expression d « e « 10d*** such that e ;;;1 x 10kkg, 2 x 10kkg, 5 x 10kkg k being a positive or negative whole number, or zero. This condition shall not apply to an instrument of class I with d < 1 mg. In that case e shall uniformly be 1 mg. ***The value of e, calculated followingthis rule, are, for example, Maximum permissible errors on veriRcatlon/ re-verification For loads m expressed In verification scale intervals e 50000< m 5 200000 5000 5 m 5 20 000 200000 < m 20000 <m < 100000 ±0.5e ±le +!.Se Class I Min 5 m 5 SO 000 Class II Min s m £ 5000 Class Ill Min5m 5500 soo 5m5 2000 2000 < m < 10000 Class IV Min5m5SO SO <m 5200 200 < m < 1000 - -- -------.-.---?--------------? 389 (ii) Values of maximum permissible errors in inspection The maximum permissible errors during inspection shall be twice the maximum permissible errors allowed on verification. (iii) Basic rules ccncerning the determination of errors (a) Influence factors Errors shall be determined under normal test condition. When the effect of one factor Is being evaluated, all other factors are to be kept relatively constant, at a value close to normal. (b) Maximum permissible errors for net values The maximum permissible errors apply to the net value of the load for every possible tare load, except preset tare values (c) Tare weighing device The maximum permissible error for a tare weighing device Is the same, for any tare value as those of the Instrument, for the same value of load. (7) Permissible difference between results Regardless of what variation of results is permitted, the error of any single weighing result shal I by itself not exceed the maximum permissible error for the given load. (i) Repeatability The difference between the maximum and minimum results of several weighings of the same load shall not be greater than the absolute value of the maximum permissible error for the given load. (ii) Eccentric loading The Indications for different positions of a load shall meet the maximum permissible errors, when the Instrument is tested according to sub-paragraphs (a) to (d) of this paragraph. (a) Unless otherwise specified hereafter, a load corresponding to 1/3 of the sum of the maximum capacity and the corresponding maximum additive tare effect shall be applied. (b) On an instrument with a load receptor having n points of support, 474 ? •)/1-'1)5" with n>4, the fraction 1/(n-1) of the sum of the maximum capacity and the maximum additive tare effect shall be applied to each point of support. (c) On an instrument with a load receptor subject to minimal off-centre loading (e.g. tank, hopper) a test load correspondingto one-tenth of the sum of the maximum capacity and the maximum additive tare effect shall be applied to each point or support. (d) On an instrument used for weighing rolling loads (e.g. vehicle scale, rail suspension instrument) a rollingtest load corresponding to the usual rolling load, the heaviest and the most concentrated one which may be weighted, but not exceeding 0.8 times the sum of the maximum capacity and the maximum additive tar effect, shall be applied at different points on the load receptor. (Ill) Multiple indicating devices For a given load the difference between the Indications of multiple indicating · devices induding tare weighing device, shall be not greater than the absolute value of the maximum permissible error, but shall be zero between digital indicating or printing devices. (Iv) Different positions of equ,1/brium The difference between two results obtained for the same load when the method of balancing the load is changed {Inthe case of an instrument fitted with a device for extending the self-indication capacity) in two consecutive tests, shall not exceed the absolute value of the maximum permissible error for the applied load. (8) Discrimination (I) Non-self indicating instrument An extra load equivalent to the value of the maximum permissible error for the applied load when gently placed or withdrawn from the instrument at equilibrium shall produce movement as required under sub-paragraph (1) of paragraph 6. (II) Self or semi-self indicating instrument (a) Analogue indication An extra load equivalent to the 390 ''THE' GAZETTE ·.OF INDIA: EXTRAORDINARY [PARTIJ---SEC. 3(i)] maximum -permrsslbte -error for ·!IPPlledload when. placed,gently on or-withdrawn-from tthe ,Instrument at -equtllbrtum shall cause a .permanent.dlsplacement .of the lndlcating.element,.correspondlngto not.less 'than ·0:7 times the extra load. (b) :.Digltai;lndlcation 1An:addltlonal,load equal to 1.4 times .the actual, .scale interval, when (Qentfy,placed,on.or withdrawn from tthe 'instrument at equilibrium shall ,change the :initial indicatlon. (9) Variation due to influence quantities and time An instrument shall comply, unless otherwise specified, with,,!ll.Jb-paragraphs (6), (7) and (8) of this paragraph under the conditions of (II)and (iii) of sub-paragraphr(9)-ofthls paragraph and additionally it shall comply with clauses (i) and (Iv) of sub­ paragraph {9) of this paragraph. · (i) lilting (a) For Instrument of dass II, III or IV liable to be tilted, the influence of tilting shall be determined under the effect of a lengthwise or transverse tilting equal to 2/1000 or corresponding to the limiting value of tilting marked on, or Indicated by a level Indicator, whichever Is the greater tilt. The absolute value of the difference between the indication of the Instrument in its reference position (not tilted) and the indication in the tilted position shall not exceed: - at no load, two verification scale intervals, (the instrument having first been adjusted to zero at no load in Its reference position) except instruments of class II. - at self indication capacity and at maximum capacity, the maximum permissible error (the Instrument having been adjusted to zero at no load both in the reference and in the tilted position). An instrument sha II be fitted with a levelling device and a level Indicator fixed firmly on the instrument in a place clearly visible to the user, unless the Instrument is: freely suspended, or installed in a fixed position, or complying with the requirements on tilting when tilted to 5% in any direction. . The limiting value of the level indicator shall be obvious, so that tilting is easily noticed. Note : Limiting value of tilting : Displacement of 2 mm from a central position. (b) On a class I instrument, the limiting value of tilting shall correspond to a tilt of no more than 2/1000 otherwise the Instrument shall meet the requirement for Instruments of class II. (ii) Temperature (a) Prescribed temperature limits If no particular working temperature Is stated in the descriptive markings of an Instrument, this instrument shall maintain Its metrological properties within the following temperature limits: -1ooc + 400c (b) Special temperature limits An instrument for which particular limits of working temperature are stated in the descriptive markings shall comply with the metrological requirements within those limits. T?e limits may be chosen according to the application of the instrument. The ranges within those limits shall be at least equal to: 5 °c for instruments of class (!) 15 °C for instruments of class (II) 30 °C for instruments of class (III) and (IV) (c) Temperature effect on no-load indication The Indication at zero or near zero shall not vary by more than one verification scale interval for a difference in ambient temperature of 1°C for instruments of class (I) and 5°C for other classes. For multi-interval instruments and for multiple range instruments this applies to the smallest verification scale interval of the instrument. (Ill) Mains power supply An Instrument operated from a mains 391 power supply shall comply with the metrologlcal requirements if the power supply varies: in voltage from :-15% to+ 100/oof the value marked on the Instrument, in frequency: from-2% to+2% of the value marked on the instrument, if alternate current Is used. (iv) Time under reasonably constant environmental conditions, an instrument of class I, II or III shall meet the following requirements. (a) When any load Is kept on the instrument, the difference between the Indication obtained Immediately after placing a load and the indication observed during the following 30 minutes, shall not exceed o. 5 e. However, the difference between the Indication obtained at 15 minutes and after that at 30 minutes shall not exceed 0.2 e. If these conditions are not met, the difference between the Indication obtained Immediately after placing a load on the Instrument and the indication observed during the followingfour hours shall not exceed the absolute value of the maximum permissible error at the load applied. (b) The deviation on returning to zero as soon as the indication has stabilized, after the removal of any load which has remained on the instrument for one half hour, shall not exceed 0.5 e For a multi-interval instrument, the deviation shall not exceed 0.5 ei_. On a multiple range Instrument, the deviation on returning to zero from Max 1 shall not exceed 0.5 e1. Furthermore, after returning to zero from any load greater than Maxiand immediately after switching to the lowest weighing range, the indication near zero shall not vary by more than e1 during the following 5 minutes. (c) The durability error due to wear and tear shall not be greater than the value of the maximum permissible error. Adherence to this requirement is assumed if the instrument has passed the endurance test specified in paragraph 9, which shall be performed only for instrument with Max?lOOkg. (10) Pilttem evaluation tests Upon pattern evaluation, the tests given In paragraph 9 and Annexure A shall be performed, to verify adherence to the requirement in sub-paragraphs (6), (7), (8) and clauses (i) to (iv) of sub-paragraph (9) of this paragraph, sub-paragraph (5) and (6) of paragraph 4, sub-paragraph (3) of paragraph 5 and sub-paragraph (1) of paragraph 6. The endurance test shall be performed after all other tests in paragraph 9 and Annexure A. 4. Technical requirements For ii se/F or semi· se/Flndfr:atfng tnstrumeots (1) General requirements of construction (I) Suitability (a) Suitability for application An instrument shall be designed to suit its intended purpose of use. (b} Suitability for use An instrument shall be solidly and carefully constructed in order to ensure that it maintains Its metrological qualities during a period of use. (c) Suitability for verification An instrument shall permit the tests set out in this specification to be performed. In particular, load receptors shall be such that the standard masses can be deposited on them easily and In total safety. If weights cannot be placed, an additional support may be required. It must be possible to identifydevices that have been subject to a separate type examination procedure (e.g. load cells, printers). {II)Security (a) Fraudulent use An instrument -shall have no characteristics likely to facilitate its fraudulent use. --/...?-?--- 392 THE GAZETTE OF INDIA: EXTRAORDINARY [PARTII-Sa:. 3(i)] (b) Acctdental- breakdown .and mal­ adjustment An Instrument shall be so constructed that an accidental .breakdown or a mal-adjustmentof control elements likelyto disturb its correct functioning cannot take place without Its effect being evident. (c) Controls controls .shall be .so designed that they cannot·normally come to rest in positions .other than those intended by ,design_, unless during the manoeuvre all Indication is made possible, :keys shall be marked unambiguously. (d) Securing (Sealing) of components and pre-set controls An .Instrument shall have provisions as required by the director legal metrology, for securing components and preset controls to which access or adjustment likely to affect the metrologlcal characteristics of the Instrument, is possible. On a class I instrument devices to adjust sensitivity may remain unsecured. (e) Adjustment If an Instrument is fitted with an automatic or a semi-automatic span adjustment device, this device shall be incorporated inside the Instrument. External influence upon this device shall be practically impossible after sealing. (f) Gravity compensation A gravity sensitive Instrument may be equipped with a device for compensating the effects of gravity variation. After securing, external influence on or access to this device shall be practically Impossible. (2) Indketton of weighing results (i) Quality of reading Reading of the results shall be rellable, easy and unambiguous under conditions of normal use: the overall inaccuracy of reading of an analogue indicatingdevice shall not exceed 0.2e. the figures forming the results shall be of a size, shape and clarity for reading to be easy. l.,L.?-- · The scale, numbering and printing shall permit the figures which form the results to be read by simple juxtaposition: Provided that this requirement shall not be applicable in the case of steel yard type weighing instruments. (II) Form of the indication (a) Weighing results shall contain the names or symbols of the units of mass in which they are expressed. For any one indication of weight, only one unit of mass shall be used. The scale interval shall be in the form 1 x 10k,2 x 10kor 5 x 10k,in which the result is expressed, the index k being a positive or negative whole number or equal to zero. All indicating, printing and tare weighing devices of an instrument shall, within any one weighing range, have the same scale Interval for any given load. (b) A digital indication shall display at least one figure beginning at the extreme right. Where the scale interval is changed automatically the decimal sign shall maintain its position in the display. A decimal fraction shall be separated from its integer by a decimal sign (comma or dot), with the indication showing at least one figure to the left of the sign and all figures to the right. Zero may be indicated by one zero to the extreme right, without a decimal sign. The unit of mass shall be chosen so that weight values have not more than one non-significant zero to the right. For values with decimal sign, the non-significant zero is allowed only in the third position after the decimal sign. (Iii) Limits of Indication There shall be no indication above Max +9 e (iv) Approximate indication device The scale interval of an approximate indicatingdevice shall be greater than MaX/100 without being smaller than [ 'WT II 1siUG 3 ( i) ] 393 20 e. This approximate device is considered as giving secondary Indications. (v) Extending the range of self-indication on a semi-self-Indicating instrument The extension Interval of the range of self­ indication shall not be greater than the value of the self-indication capacity. (a) The scale interval of extension of the range of the self-indication should be equal to the capacity of self, indication (comparator instruments are excluded from this provision). (b) An extension device with accessible sliding poises is subject to the requirements of clause (ii) of sub­ paragraph (2) of paragraph 6. (c) On an extension device with enclosed sliding poises or mass switching mechanisms each extension should involve an adequate change in the numbering. It should be possible to seal the housing and the adjusting activities of the weights or masses. 1.10"@ I (3) Analogue indicating device. The followingrequirements apply in addition to those In clause (i) to (iv) of sub-paragraph (2) of this paragraph. (I) Scalemarks : Length and width Scale shall be designed and numbered so that reading the weighing results is easy and unambiguous. (a) Formsofscalemarks. Scale marks shall consist of lines of equal thickness; this thickness should be constant and between 1/10 and 1/4 of the scale spacing, without being less than 0.2mm. The length of the shortest scale mark should be at least equal to the scale spacing. (b) Arrangements of scale marks Scale marks should be arranged In accordance with one of the sketches in Figure 32-D (the line joining the end of the scale marks optional). 2.1<>"@ I I I 5.10"® ii, r,1,1,r,l ,r,1,1,1,L Figure 32 D-Examples of the application to rectilinear scales (c) Numbering On one scale, the scale Interval of numbering should be: --constant, -In the form 1 x 10k,2 x 10k,5 x 10k units (k being a positive or a negative whole number or equal to zero), -not greater than 25 times as the scale Interval of the instrument. If the scale is projected on a screen, at least two numbered scale marks l(7 4 e, 6}!t - 9 9 should appear wholly in the projected zone. The height of the number (real or apparent) expressed in millimetres should be not less than 3 times the minimum reading distance expressed in metre, without being less than 2 mm. This height should be proportional to the length of the scale mark to which it relates. The width of a number, measured parallel to the base of the scale, ---- - -dj=·-??====== 394 . THE GAZETTE OF INDIA: EXTRAORDINARY [PARTII-SEC. 3(i)] should .be. less .than .the distance between two consecutive numbered scale marks. (d) Indicating component The width of the polnter of the indicating components should be approximately equalto 'that of the scale marks and of the ·1engthsuch that the tip is etteast level with the shortest mark. .The distancebetween the scale and the pointer should be at the most equal to the .scale spacing, without being greaterthan 2mm. (ii) Scale spadng on an instrument of class{!) or (II); 1 mm for indicatinqdevlces: 0.25 mm for complementary Indicating devices; on an instrument of class III and III!. 1.25 mm for dial indicating devices. 1. 75 rnm for optical projection Indicating devices. (iii) Umitsofindication Stops shall be provided to limit the movement of the indicating component whilst allowing it to travel below zero and above the capacity of self-indication. This re-requirements does not apply to multi­ revolution dial instruments. The stops limiting the movement of the indicatingcomponents should permit it to travel across zones of at least 4 scale spacings below zero and above the capacity of self-Indication (three zones are not provided with a scale on fan charts and on dials with a single revolution pointer they are called "blank zone"). (iv) Damping Dampingshould achieve a stable Indication within 5 simple half periods of oscillation. Hydraulic damping elements sensitive to variations In temperature should be provided with an automotive regulating device or an easily accessible manual regulating device. It should be Impossible for the fluid of hydraulic damping elements on portable instruments to spill when the instrument is inclined at 450, (4) Dig/ta/indicating and printing devices The following requirements apply in addition to those in clauses (i) to (v) of sub-paragraph (2) of this paragraph. (i) Change of indication After a change in load, the previous Indication shall not persist for longer than 1 second. (II) Stable equilibrium Equilibrium is deemed to be stable when,- ln case of printing and/or data storage, the requirement in clause (v) of sub­ paragraph {4) of this paragraph are met, In case of zero or tare operations clauses (Iv), (vi), (vii) of sub-paragraph (5) and (viii) of sub-paragraph (6) of this paragraph, it is sufficiently close to the final equilibrium to allow a correct operation of the device within relevant accuracy requirements. (Ill) Extended indicating device An extended indicating device shall not be used on an instrument with a differentiated scale division. When an instrument is fitted with an · extended indicating device, displaying the Indication with a scale interval smaller than 'e' shall be possible only. during pressing a key, or ' for a period not exceeding 5 seconds after a manual command. In any case printing shall not be possible. (Iv) Multiple use of indicating device Indications other than primary indication may be displayed in the same indicting device, provided that, - Quantities other than weight values are Identified by the appropriate unit of measurement, or symbol thereof, or a special sign. Weight values that are not weighing results (sub-clause (I) through clause (Ill) of sub-paragraph (2) of paragraph 5 Part I ) shall be clearly identified, or they may be displayed only temporarily on manual command and shall not be printed. No restrictions apply if the weighing mode Is made inoperative by a special command. ['WT 11-= 3(i)] 395 (v) Printing device Printing shall be clear and permanent for the intended use, printed figures shall be at least 2 mm high. If printing takes place, the name or the symbol of the unit of measurement shall be either to the right of the value. or above a column of values. Printing shall be impossible when the equilibrium is not stable. Stable equilibrium is considered to be achieved when over a period of 5 seconds following printout, no more than two adjacent values are indicated, one of which being the printed value. (vi) Memory storage device The storage of primary indications for subsequent indication, date transfer, totalizing, etc, shall be impossible when the equilibrium is not stable. The criterion of stable equilibrium is the same as in clause (v) of sub-paragraph (4) of paragraph 4. (5) Zero setting and zero-tracking devices An instrument may have one or more zero· setting devices and shall have not more than one · zero-tracking device. (i) Maximum effect The effect of any zero setting device shall not alter the maximum weighing capacity of the instrument. The overall effect of zero setting and zero tracking device shall be not more than 4% and of the initial zero setting device not more than 20% of the maximum capacity. (ii) Accuracy After zero setting, the effect of zero deviation on the result of the weighing shall be not more than 0.25 e; however, on an Instrument with auxiliary Indicating device this effect shall be not more than 0.5 d. (iii) Multiple range instrument Zero setting In any weighing range shall be effective also in the greater weighing ranges If switching to a greater weighing range Is possible while the instrument is loaded. (iv) Control of the zero setting device An instrument except an Instrument according to sub-paras (13) and (14) of this paragraph, whether or not equipped with an initial zero-setting device, may have a combined semi-automatic zero-setting device and a semi-automatic tare-balancing device operated by the same key. If an instrument has a zero device and a tare-weighing device, the control of the. zero-setting device shall be separated from that of the tare-weighing device. A semi-automatic zero setting device shall function only; and when the instrument is In stable equilibrium, it cancels any previous tare operation. (v) Zero indicating device on an instrument with digital indication An Instrument with digital indication shall have device that displays a special signal when the deviation from zero is not more than 0.25 e. This device may also work when zero is indicated after a tare operation. This device is not mandatory on an Instrument that has an auxiliary indicating or a zero-tracking device provided that the rate of zero tracking is not less than 0.25 d/second. (vi) Automatic zero setting device An automatic zero-setting device shall operate only when,- the equilibrium is stable, and the indication has remained stable below zero at least 5 seconds. (vii) Zero tracking device A zero tracking device shall operate only when.- the indication is at zero, or at a negative net value equivalent to gross zero, and the equilibrium is stable, and the corrections are not more than 0.5 d/ second. When zero is indicated after a tare operation, the zero tracking device may operate within a range of 4% of max around the actual zero value. (6) Tilre device (I) General requirements : A tare device shall comply with the relevant provisions of sub-paragraph ( 1) through (4) of this paragraph. ' ? -- 396 THE GAZETTE OF INDIA: EXTRAORDINARY [PARTII-SEC. 3(i)] (ii) Scale interval: The scale interval of a tare-weighing device shall be equal to the scale Interval of the instrument for any given load. (iii) Accuracy: A tare device shall permit setting the indication to zero with an accuracy better than: ± 0.25e for electronic instruments and any instrument with analogue indication. ± 0.25e for mechanical instruments with digital indication and instruments with auxiliary ,indication device. ± O.Se for mechanical instruments with digital indication and instruments with auxiliary indication device. On a multi-interval instrument e shall be replaced by e1. (iv) Operating range The tare device shall be such that It cannot be used at or below its zero effect or above its maximum indicated effect. (v) Visibilityof operation Operation of the tare device shall be visibly indicated on the instrument. In the case of instruments with digital indication this shall be done by marking the indicated net value with the sign "NET" or "Net" or "net". Note: If an instrument is equipped with a device that allows the gross values to be displayed temporarily while a tare device is In operation, the "NET" symbol disappears while the gross value is displayed. This is not required for an Instrument with a combined semiautomatic zero-setting device and a semi-automatic tare­ balancing device operated by the same key. (vi) Subtractive tare device: When the use of subtractive tare device does not allow the value of the residual weighing range to be known, a device shall prevent the use of the Instrument above its maximum capacity or Indicate that th Is capacity has been reached. (vii) Multlple range instrument: On a multiple range instrument the tare operation shall be effective also in the greater weighing ranges, if switching to a greater weighing range is possible while the Instrument is loaded. (viii) Semi-automatic or automatic tare devices These devices shall operate only when the instrument is in stable equilibrium. (ix) Combined zero setting and tare balandng device If the semi automatic zero setti? device and semi automatic tare balancing device are operated by the same key; sub clause (II) and (v) of sub-paragraph (5) of this paragraph and if appropriate sub-clause (vii} of sub-paragraph (5) of this paragraph apply at any road. (x) Consecutive tare operations Repeat operation of a tare device is permitted. If more than one tare device is operative at the same time, tare weight values shall be clearly designated when indicated or printed. (xi) Printing of weighing results Gross weight values may be printed without any designation. For a designation by a symbol, only "G" Is permitted. If only net weight values are printed without corresponding gross or tare values, they may be printed without any d?slgnation. A symbol for designation shall be "N". This applies also where semi­ automatic zero setting and semi­ automatic tare balancing are initiated by the same key. Gross, net or tare values determined by a multiple range instrument or by a multi­ Interval instrument need not be marked by a special designation referring to the (partial) weighing range. If net weight values are printed together with the corresponding gross and/or tare values, the net and tare values shall at least be identified by the corresponding symbof ''N" and ''T'? However, tt is permitted to replace the symbols G, N, T by complete words. If net weight values and tare values .determined by different tare devices are printed separately, they shall be suitably Identified. [IWTil-?3(i)] 397 (7) Preset tare device (7)(i) Scale interval Regardless of how a preset tare value is ,r,t,oduced into the device, its scale interval shall be equal or automatically rounded to the scale interval of the instrument. On a multiple range instrument, a preset tare value may only be transferred from one weighing range to another one with a larger verification scale interval but shall then be rounded to the latter. For a multiple Interval instrument, the maximum preset tare value shall not be greater than Maxi and the indicated or printed,calculated net value shall be rounded to the scale interval of the instrument for the same net weight value. (ii) Modesofoperation A preset tare device may be operated together with one or more tare devices provided that: clause (x) of sub-paragraph (6) of this paragraph Is complied, and a Preset tare operation cannot be modified or cancelled as long as any tare device operated after the preset tare operation is still in use. preset tare devices may operate automatically only if the preset tare value is clearly identified with the load to be measured. (iii) Indication of operation For the indicating device clause (v) of sub­ paragraph (6) of this paragraph applies. It shall be possible to indicate the preset tare value at least temporarily. Provisions of clause (xi) of sub-paragraph (6) of paragraph 4 applies accordingly provided that if the calculated net value Is printed, at least the preset tare value Is printed as well, with the exception of an Instrument covered by sub-paragraphs (13), (14) or (16} of this paragraph. Preset tare values are designated by the symbol "PT"; however, it is permitted to replace the symbol "PT" by complete words. (8) Lockingpositions :i) Prevention of weighing outside the "weight" position If an instrument has one or more locking device, these devices shall only have two stable positions corresponding to "locked" and "weigh"; and weighing shall only be possible in the "weigh" position. A "pre-weigh" position may exist on any instrument of class I or JI, except under sub-paragraphs (13), (15) or (16) of this paragraph. (ii) Indication of position The "locked" and "weigh" positions shall be clearly shown. (9) Auxiliary calibration devices (removable or fixed) (I) Devices with one or more platform The nominal value of the ratio between the weights to be placed on the platform to balance a certain load and this load shall not be less than 1/5000 (it shall be visibly Indicated just above the platform). The value of the weights needed to balance a load equal to the verification scale interval shall be an integer multiple of O.lg (ii) Numbered sca(edevices The scale interval of the auxiliaryverification devices shall be equal to or smaller than 1/5 of the verification scale interval for which it is intended. (1OJSelection of weighing 1anges on a weighing scale on a multiple range instrument The range which is actually in operation shall be clearly indicated. (a) Manual selection of the weighing range is allowed -from a smaller to a greater weighing range at any load; -from a greater to a smaller weighing range when there is no load on the load receptor and the indication is zero at a negative net value. The tare operation receptor shall be cancelled and the zero shall be set to± 0.25 e both automatically. (11) Device for selection (or switching) between various load receptors-Load transmitting devices and various load measuring devices (1)Compensation of no load effect The selection device shall ensure compensation for the unequal no load effect 398 THE •GAZETTE OF INDIA: EXTRAORDINARY [PARTIl-SEC 3(i)] of the various 'loed receptors-lead transmitting devices, ln.use, (ii) Zerosetting Zero setting ·of an instrument with any multiple ,combination of various load measuring devices and various load receptors ·shall be possible without any _ambiguity and in .accordance with the provisions Of sub-paragraph (5) of paragraph 4. (iii) Impossfbllttyofweighing Weighing .shall not be possible while selectfon devices are being used. (iv) Identification of the combination use Combination of load receptors and load measuring devices used shall be readily identifiable. (12) "PlusH and "minus· comparative Instrument For the purpose of verification a "heavy" or "plus» and "light" or "minus" comparators Instrument is considered to be a semi-self indicating Instrument. (i) Distinction between "pus" and "mtnus" zone On an analogue indicating device, the zones situated on either side of zero shall be distinguished by"+" and"·", On a digital indicating device, an inscription nearer the indicating device shall be given, range ± gram (kg, t) range gram (kg, t)/+ gram (kg, t) (ii) Form of scale Scale of a comparator instrument shall have at least one scale division dequal to e (d = e} on either side of zero. The corresponding value shall be shown at either end of the scale. {13) Additlonaf requirement for an instrument for direct sales to the pubfJ:. The following requirements apply to an Instrument of class II, III, or IV with a maximum capacity not more than 100 kg capacity designed for direct sa!e to the public. (i) Primary Indication On an Instrument for direct sale to the public, the primary indications are the weighing results and the information about the correct zero position, tare, and pre-set tare operation. (II) Zero setting device An Instrument for direct sale to the public shall not be fitted with a non-automatic zero setting device unless operated with a tool. (Iii) Tare device A mechanical instrument with a weight receptor shall not be fitted with a tare device. An Instrument shall not be fitted with a device which can recall the gross value while a tare or pre-set tare device is In operation. (a) Non-automatic tare device A displacement of 5 mm of a point of the control shall be at the most equal to one verification scale interval. (b) Semi-automatic tare device An instrument may be fitted with semi automatic tare device if- the action of the tare device does not permit the reduction of the tare; and their effect can only be cancelled when there is no load on the load receptor. In addition, the instrument shall comply with at least one of the following requirements: the tare value is indicated permanently in a separate display, the tare value Is indicated with a sign "·" (minus), when there is no load on the load receptor, or the effect of the device is cancelled automatically when the indication returns to zero when unloading the load receptor after the stable net weighing results greater than zero has been indicated. (c) Automatic tsre device An instrument shall not be fitted with an automatic tare devices. (Iv) Preset tare device A preset tare device may be provided if the preset tare value is indicated as a . primary indication on a separate display ['1Tll II-? 3{i)] 399 which is clearly differentiated from the weight display sub-clause (b) of clause (iii) of sub-paragraph (13) of this paragraph, applies. It shall not be possible to operate a pre­ set tare device, if a tare device is In use. Where a preset tare is associated with a price look up (PLU),the preset tare value may be cancelled at the same time, as the PLU is cancelled. (v) Impossibility of weighing It shall be Impossible to weigh or to guide the indicating element during the normal locking operation or during the normal operation of adding or subtracting weights. (vi) Visibility All primary Indications shall be displayed clearly and simultaneously to both the vendor and the customer. On digital devices that display primary indications, the numerical figures on either set shall be of the same dimension and at least 10 mm high, with a tolerance of 0.5mm On an instrument to be used with weights, it shall be, possibleto distinguish the value of the weights. · (vii) No auxilfary and extended indicating device An instrument shall not be fitted with any auxiliary indicating device nor an extended indicating device. (viii) Instrument of class II An Instrument of class II shall comply with the requirements given in sub-paragraph (9) of paragraph 3 for an Instrument of class Ill. (ix) Significant fault When a significant fault has been detected, a visible or audible alarm shall be provided for the customer, and data transmission to any peripheral equipment · shall be prevented. This alarm shall continue until such time as the user takes action or the cause disappears. (x) Counting ratio The counting ratio on a mechanical counting Instrument shall be 1/10 or 1/100. (14) Additional requirements for an instrument for dlrea sale to the public with price indication The following requirements are to be applied in addition to sub-para(13) of this rule: (I) Primary indications On a price indicating Instrument, the supplementary primary Indication are unit price and price to pay and if applicable, number, unit price and price to pay for non-weighed articles and price totals. Price charts, such as fan charts, are not subject to the requirements of this specification. (Ii) Instrument with price scales For unit price and price-to-pay scales, sub­ paragraph (2) r:J this paragraph and dauses (i) to (iii) of sub-paragraph (3) of this paragraph apply accordingly. The decimal shall be indicated to two places. Reading from price scales shall be so possible that the absolute value of the difference between the product of the Indicated weight Wand unit price U and the indicated price to pay Pis not greater than the product of e and the unit price of that scale. 1w.u- P Is e.u (ill) Price computing instrument (a) The price to pay shall be calculated and rounded to the nearest interval of price to pay, by multiplication of weight and unit price, both as indicated by the instrument. The device which performs the calculations in any case considered a part of the instrument. (b) The unit price is restricted to price/ 100g or price/kg. (c) Notwithstanding. the provisions In clause (i) of sub-paragraph (4) of this paragraph, the indication of weight unit price and price to pay, shall remain visible after the weight indication is stable and after any introduction of the unit price, for at least one second and while the load is on the load receptor. (d) Notwithstanding the provisions in clause (i) of sub-paragraph (4) of this paragraph, these indications 400 THE·GAZETTE OF INDIA: EXTRAORDINARY [PARTII-SEC. 3(i)] . may remain visible for not more than Jc seconds after ·removing the load, .provlded that.thewelqht indication · has· been stable 'before and the Indication would.otherwise be zero. As long as there Is a weight -fncllcatlon after ,removing the load, !'It shall notbe .possible to introduce or.change.a .unlt price. (e) .Iftransection performed by the : Instrument is printed, weight, unit ;price and price-to-pay shall all be ,printed. (f) The data may be stored in a memory .of the instrument before printing. h same data shall not be printed twice on the ticket for the customer. Instrument that can be used for price labelling purpose, must comply with sub-paragraph (16) of this paragraph as well. (iv) Specialapplications of a price computing instrument Only if all transaction performed by the instrument or by connected peripheral are printed on a ticket or label Intended for the customer, a price computing instrument may perform additional functions which facilitate trade and management. These functions shall not lead to confusion about the results of weighing and price computing. Other operations or indications not covered by the following provisions may be performed, provided that no Indication which could possibly be misunderstood as a primary Indication, is presented to the customer. (a) Non-weighed articles An Instrument may accept and record positive or negative prices to pay one of several non-weighed articles, provided the weight indication is zero or the weighing mode is made inoperative. The price-to-pay for one or more of such articles, shall be shown in the price­ to-pay display. If the price to pay is calculated for more than one equal article, the number of such articles shall be shown on the weight display,without being possibly taken for a weight · and the price for one article on the unit price display, unless supplementary display are used to show the number of articles and articles price. (b) Totalization An instrument may totallze transaction on one or several tickets; the price total shall be indicated on the price-to-pay display and printed, accompanied by a special word or symbol, either at the end of the price-to-pay column or on a separate label ticket with appropriate reference to the commodities whose prices to pay have been totalized; all prices to pay that are totalized shall be printed and the price total shall be the algebraic sum of all these prices as printed. An instrument may totalize transaction performed on other instruments linked to it, directly or over metrologically controlled · peripherals, and if the price-to-pay scale intervals of all connected instruments are identical. (c) Multi-vendor operation An instrument may be designed to be used by more than one vendor or to serve more than one customer at the same time provided that the connection between the transactions and the relevant vendor or customer is appropriately identified. (d) Cancellation An instrument may cancel previous transaction, where the transaction has already been printed, the relevant pnce-to-pev cancelled shall be printed with an appropriate comment. If the transaction to the cancelled is displayed to the customer, it shall be clearly differentiated from normal transaction. (e) Additional information An instrument may print additional information if this is clearly correlated to the transaction and does not interfere with the assignment of the weight value to the unit symbol. 401 (v) Self servke Instrument ·-"•· A self service instrument need not have· two sets of scales displayed. If a ticket or label is printed, the primary indications shall include a designation of · the product when the instrument used to sell different products. (15) Instruments similar to one normally used for direct sale to the public An Instrument similar to one normally used for direct sale to the public which does not com ply with the provisions of sub-paragraphs (13) and (14) of this paragraph shall carry near the display,the . indelible marking : "NOT TO BE USED FOR DIRECT SALE TO THE PUBLIC" (16) Price label/Ing instrument Clause (viii) of sub-paragraph (13), sub· clauses (a) and (e) of clause (Ill) of sub­ paragraph (14), sub-clause (a) of clause (iv) of sub-paragraph (14) and sub-clause (e} of dause (iv) of sub-paragraph (14} of this paragraph respectively apply. A price labelling instrument shall have at least one display for the weight. It may be used temporarily for set-up purpose such as supervision of setting weight limits, unit price, preset tare values, commodity names. It shall be possible to verify,during use of the Instruments, the actual values of unit price and preset tare value. Printing below minimum capacity shall not be possible. Printing of labels with fixed values of weight, unit price and price-to-pay is allowed provided that the weighing mode is made In-operative. (17) Meehan/cal counting instrument with unit­ weight receptor For the purpose of verification, a counting instrument Is considered to be a semi­ self indicating instrument. (i) Indicating device To permit verification, a counting instrument shall have a scale with at least one scale division d = e on either side of zero, the corresponding value shall be shown on the scale. t,7lt 4 0}11- /o/ (Ii) Counting ratio The counting ratio shall be shown dearly Just above each counting platformor each counting scale mark. 5. Requirements for electronic instruments In addition to paragraphs 3 and 4, an electronic instrument shall comply with the following requirements. (1) Generi:!I requirements (i) An electronic instrument shall be designed and manufactured such that when It Is exposed to disturbances : either; (a) significant faults do not occur, or (b) significant faults are detected and acted upon. . Note: A fault equal to or smaller than eis allowed Irrespective of the value of the error cf Indication. (II) The requirements in sub-paragraphs (6), (7), (8) and (9) of paragraph 3 and clause (I) of sub-paragraph (1) of this paragraph shall be met durably in accordance with the Intended use of the instrument. (Iii) A pattern of an electronic instrument Is presumed to comply with the requirements In clause (i) and (ii) of sub-paragraph (1) and clause (ii) of sub-paraqraph (3) of this paragraph, If it passes the examinations and tests specified in sub-paragraph (4) of this paragraph. (iv) The requirements In (I) of sub-paragraph (1) of this paragraph may be applied separately to- (a) each individual clause of significant fault, and/or; (b) each part of the electronic instrument The choice; where sub-clause (a) or (b) of clause (i) of sub-paragraph (l} of paragraph 5 is applied, is left to the manufacturer. (2) Acting upon significant faults , When a significant fault has been detected, the instrument shall either be made Inoperative automatically. or a visual or audible indication shall be provided automatically and shall continue until such time as the user takes action or the fault disappears. ----- --- - _J -?---- - 402 THE GAZETTE OF INDIA: EXTRAORDINARY [PARTII-SEC. 3(i)] ·-, (3) Functional requirements (i) Upon·swltch on (switch-on of indication), a special procedure shall be performed that shows all relevant signs of the indicator ln.the active and non-active state sufficiently long to be checked by the operator. (ii) In addition to the sub-paragraph (9) of paragraph 3 an electronic instrument shall comply wlth the .requirements under relative:humldityof 85%.at the upper limit of the temperature range. This Is not applicable to an electronic instrument of class I and of class II, if e Is less than 1 g. (iii) Electronic Instruments, class I Instruments exempted, shall be subjected to the span stability test specified in clause (Iv)of sub­ paragraph (4) of this paragraph. The error near maximum capability shall not exceed the maximum permissible error and the absolute value of the difference between the errors· obtained for any two measurements shall not exceed half the verification scale interval or half the value of the maximum permissible error, whichever Is greater. (iv) When an electronic instrument is subjected to the disturbances specified in clause (iii) of sub-paragraph (4) of this paragraph, the difference between the weight indication without the disturbance (intrinsic error), shall not exceed e or the instruments shall detect and react to a significant fault. (v) During the warm-up time of an electronic instrument there shall be no Indication or transmission of the weighing result. (vi) An electronic instrument may be equipped with Interfaces permitting the coupling of the instrument to any peripheral devices or other Instruments. An interface .shall not allow the metrologlcal functions of the Instruments measurement data to be inadmissibly influenced by the peripheral devices (for example computers), by other interconnected instruments, or by disturbances acting on the Interface. Functions that are performed or Initiated via an Interface shall meet the relevant requirements and conditions of clause (iv) of this sub-paragraph. Note : An "interface" comprises all mechanical, electrical and logic properties at the data Interchange point between an instrument and peripheral devices or other Instruments. (a) It shall not be possible to introduce into an instrument, through an interface, instructions or data intended or suitable to: o display data that are not clearly defined and could be mistaken for a weighing result, o falsifydisplayed, processed or stored weighing results, o adjust the instrument or change any adjustment factor; however instructions may be given through the interface to carryout an adjustment procedure using a span adjustment device incorporated inside the instrument or for instruments in class I, using an external standard mass, o falsify primary indication displayed in case of direct sales to the public. (b) An interface through the functions mentioned in sub-cl a use (a) of clause (vi) of sub-paragraph (3) of this paragraph cannot be performed or initiated, need not be secured. Other interface shall be secured as per sub-clause (d) of clause (ii} of the sub-paragraph (1) of paragraph 4. (C, An interface intended to be connected to a peripheral device to which the requirements of this (Schedule) apply, shall transmit data relating to primary indication in such a manner that the peripheral device can meet the requirements. (vii) A battery operated electronic instrument shall either continue to function correctly or not indicate any weight values, whenever the voltage is below the manufacturer's specified value. (4) Performance and span stability tests (I) Test considerstions : All electronic instruments of the same · category, whether or not equipped with checking facilities, shall be subjected to the same performance test programme. (II) State of instrument under test: Performance tests shall be carried out on fully operationalequipment in its normal --- -·-- --- ----. :.. .. . . ['WT 11-= 3(i)] 403 operational state or in a status, as similar as possible thereto. If an electronlc instrument is equipped with an interface permitting the coupling of the instrument to external equipment, the instrument shall, during the tests mentioned In sub-paragraphs (2), (3) and (4) of paragraph 3 of Annexure A be coupled to external equipment, as specified by the test procedure. (iii) Performance test Performance tests shall be performed according to paragraphs 2 and 3 of Annexure A. TABLE 43-A Tests Characteristic under test Static temperature Influence factor Damp heat, steady state Influence factor Power voltage variations Influence factor Short time power reductions Disturbance Bursts (transients) Disturbance Electrostatic discharge Disturbance Electromagnetic susceptibility Disturbance (iv) Span stability test Span stability test shall be performed according to paragraph 4 of Annexure A. 6. Technical requirements for a non-self Indicating Instrument A non-self-Indicating instrument shall comply, as far as applicable, with paragraphs 3 and 4. (1) Minimum sensitivity An extra load equivalent to the absolute value of the maximum permissible error for the applied load, shall be placed on the instrument at equilibrium and shall cause a permanent displacement of the Indicating element of at least 1 mm for an Instrument of class I or II 2 mm for an Instrument of class III or IV with Max. 30 kg S mm for an Instrument of class III or IV with Max. 30 kg The sensitivity tests shall be carried out by placing extra loads with a slight Impact in order to eliminate the effects of discrlmlnatlon threshold. (2) Indicating deVice (I) General provisions - (a) Equilibrium.Indicatingcomponent If two indices are provided, with one fixed and another movable then the thickness of the two indicating components shall be equal and the distance between them shall not exceed their thickness. However, this distance may be equal to 1 mm, If the thickness of the indices is less than this value. (b} Securing It shall be possible to secure the sliding poises, the removable masses and the adjusting cavities or the housings of such devices as prescribed by Director. (c) Printing If the device permits printing, this should be possible only if slidingbars or poises or a mass switching mechanism are each in a position corresponding to a whole number of scale divisions. Except for accessible sliding poises or bars, printing should be possible only if the equilibrium indicating component is in the reference position to within the nearest half scale interval. (II) SI/dingpoise device (a) Form of scale marks On bars on which the scale interval is the verification scale interval of the instrument, the scale marl<s shall consists of lines of constant thickness. On other major ( or minor) bars, the scale marks shall consist of notches. (b) Scale spacing The distance between scale marks shall not be less than 2 mm and be of sufficient length so that the normal machining tolerance for notches or scale marks does not cause an error in the weighing result exceeding 0.2 of the verification scale interval. · (c) Stops The displacement of slidingpoises on major and minor bars shall be limited 404 THE GAZETTE OF INDIA:EXTRAORDINARY [PARTII-SEC. 3(i)] to the graduated part of major and minor bars. (d) Indicating component Each sliding poise device shall be provided with an indicating component. (e) Accessible sliding poise device ·niere shall be no moving parts in •slidingpoises, except sliding minor :bars. "There -shall be no cavity on sliding poises that could accidentally hold foreign bodies. .It shall be possible to secure parts that are detachable. The displacement of sliding poises on major and minor bars shall require a certain effort. (iii) Indication by use of proportional weights The reduction ratios shall be in the form 10k,k being an integer or zero. On an Instrument intended for direct sale to the public,the height of the raised edge of the weights receptor platform should not exceed one-tenth of the greatest dimension of the platform, without being , more than 25 mm. (J) Condition of construction (1) Equilibrium indicating component An Instrument shall be provided with two moving Indices or one moving Indicating component and a fixed datum mark, the respective position of which Indicates the reference position of equfllbrlum. On an Instrument of class III or IV designed to be used for direct sale to the public, the Indices shall allow the equilibrium to be seen from the opposite sides of the Instrument. (ii) Knives, bearings and friction plates. (a) lypes of connection Levers shall be fitted with knives only and these shall be pivoted on bearings. The fine of contact of the knives and bearing shall be a straight fine. Counter beams shall be pivoted on knife edges. (b) Knives The knives shall be fitted to the levers In such a way that the invariabilityof the ratios of the lever arms is assured. They shall not be welded or soldered. The edges of the knives of one and the same lever shall be practically parallel and shall be situated in one plane. (c) Bearings : The bearings shall not be welded or soldered to their supports or in their mountings. It shall be possible for bearings of an instrument with ratio platforms and steelyards to osclllate in all directions on their supports or in their mountings. On such instruments anti· disconnection devices shall prevent the disconnection of articulated parts. · (d) Friction plates : The longitudinal play of the knives shall be limited by friction plates. There shall be point contact between knife and friction plates and it shall be situated on the extension of the line(s) of contact between knife and bearing(s). The friction plate shall form a plane through the point of contact with the knife and its plane shall be perpendicular to the line of the contact between knife and bearing. It shall not be welded or soldered to the bearings or their support. (iii) Hardness Contact parts of knives, bearings, friction plates, inter levers, inter lever supports and finks shall have a hardness of at least 58 Rockwell C. (iv) Protective coating A protective coating may be applied to the parts in contact of jointed components provided that this does not lead to changes of metrological properties. (v) · Tare devices No Instrument shall be fitted with a tare device. (4) Simple sliding poise instrument (steelyard) (I) General (a) Scale marks : The scale marks shall be lines or notches, either on the ['lflT [[-<§!Us 3(i)] 405 edge, or on the flat of the graduated shank. The minimum scale spacing is 2 mm between notches and 4 mm between lines. (b) Pivots : The load per unit length on the knives shall be not more than 10 kg/mm. The bores of bearing in the form of an annulus shall have a diameter at least equal to 1.5 times the largest dimension of the cross section of the knife. (c} Equilibrium indicating component The length of the equilibrium indicating component, if provided taken from the edge of the fulcrum knife-edge of the instrument, shall be not less than 1/15 of the length of the graduated part of the major sliding poise bar. (d) Distinctive mark The head and the sliding poise of an Instrument with detachable sliding poises shall bear the same distinctive mark. (ii) Instrument with single capacity (a) Minimum distance between knife­ edges The minimum distance between knife-edges is, - 25 mm for maximum capacities less than or equal to 30 kg. 20 mm for maxim um capacities exceeding 30 kg. (b) Graduation The graduation shall extend from zero to the maximum capacity. (c) Zero setting If an instrument of class III or IV is provided with a zero-setting device, this shall be a captive screw or nut arrangement with a maximum effect of 4 verification scale intervals per revolution. (5) Instrument with a load measuring device with accessible sliding poises {of steelyard type) (i) General The provisions of sub-paragraph (2) of paragraph 6 relating to load measuring devices with accessible sliding poises shall be observed. (ii) Range of numbered scale The numbered scale of the instrument shall permit continuous weighing from zero to the maximum capacity. (iii) Minimumsca/espacing The scale spacing ix of the different bars (x = 1, 2, 3 .... ) ix? dx/( ex 0.05) mm but ix? 2mm ·(iv) Ratio platform If an instrument is provided with a ratio platform for extending the indicating range of the numbered scale, the ratio between · the value of the weights placed on the platform to balance a load and the load itself shall be 1/10 or 1/100. This ratio shall be indicated legibly and permanently on the beam in a positionclose to the ratio platform, in the form 1 : 10, 1 : 100 or 1/10, 1/100. (v) Zero setting An instrument shall have a zero-setting device consisting: either of a cup with greatly convex cover or of a captive screw or nut arrangement with a maximum effect of 4 verification scale intervals per revolution. (vi) Lockingof the beam An instrument shall have a manual device for locking the beam, the action of which prevents the equilibrium indices coinciding when at rest. (vii) Wooden parts If certain parts of an instrument, such as the frame, the platform or the board are of wood, this shall be dry and free from defects. It shall be covered with a paint or an effective protective varnish. No nails shall be used for the final assembly of wooden parts. 7. Marking of an instrument (1) Descriptive markings All instruments shall carry, in order, the following markings: (i) Compulsory in all cases manufacturer's mark, or name written in full, ----?· ---- -- - ---- ---? ------·?.J>-·· 406 THE GAZETTE OF INDIA:EXTRAORDINARY [PARTII-SEC. 3(i)] • indication of accuracy class in the form for special accuracy I for high accuracy JI for medium accuracy m for ordinary accuracy N • maximum capacity in the form Max • minimum capacity in the form Min · verifkation scale intervalin the fonn e = (ii) Compulsory If applicable mark of manufacturer's agent for an imported Instrument, identification mark on each unit of an instrument consisting of separate but associated units. · pattern approval mark, · scale Interval if d-c e in the form d = .: maximum additional in the form T = + ... tare effect • maximum subtractive in the form T = - ... tare effect If different from Max in the form 1 : ...... or 1/ . ± mg/g/kg/t · maximum safe load • the special temperature limits within which the instrument complies with the prescribed conditions of correct operation in the form Lim = in the form •c; ....... •c; • counting ratio on a counting instrument range of plus/minus Indication of a digital comparator instrument (iii) Presentation of descrtptiVe markings The descriptive marking shall be indelible and of a size shape and clarity allowing easy reading. They shall be grouped together in a clearly visible place either on a descriptive plate fixed to an instrument, or on a part of the Instrument itself. The markings:Max . Min .. e . d lfd = e and Accuracy class . shall also be shown near the display of the result if they are not already located there. It shall be possible to seal the plate bearing the descriptive marking. (a) Markings in special cases: In special case, some of the markings shall be In the form of a table as illustrated below:- For a multi-interval For an Instrument with more For an instrument with instrument than one weighing range (W1, ?) , weighing ranges in differentdasses Wt W2 W1 W2 II . m Max 2/5/15 kg Max 20 kg 100kg Max 1000g 5000g Min20g Min 200g 1 kg MinSg 40g e = 1/2/5 g e = 10g 50g e = 0.1 g 2g d =0.02g 2 (b) Dimensions : When several plates are placed one above the other (as for example In the case of an instrument consisting of several separate devices) they should be of the same width. This common width is fixed at 80 mm. (c) Fixing: The plate shall be fixed by rivets or screws with one of the rivets of red copper or material having qualities recognised as similar. It should be possible to secure the head of one of the screws by means of a lead cap inserted in a device that cannot be dismantled. The diameter of the rivet or of the lead cap should be able to accommodate a stamp 4 mm in diameter. (d) Dimension of the letters : The height of capital letters should be at least 2 mm. (Iv)Specific cases (a) Instrument having several load receptors and load measuring devices Each load measuring device which Is connected or can be ccnnected to one or ['IT'f n-= J(i)J 407 more load receptors, shall bear the descriptive markings relating to these viz. identification mark, maximum capacity, minimum capacity, verification scale interval and if appropriate, maximum safe load and maximum additive tare effect. (b) Instruments consisting of separately built main parts If main parts cannot be exchanged without altering the metrological characteristics of the Instrument, each unit shall have an identification mark which shall be repeated in the descriptive markings. (2) Verification marks (i) Position An Instrument shall have a place for the application of verificatiOn marks. This place shall,- be such that the part on which It is located cannot be removed from the instrument without damaging the marks allow easy application of the marks without changing the metrological qualities of the instrument be visible without the instrument having to be moved, when It is In service. (ii) Mounting An Instrument required to bear verification marks sha II have a verification mark support, at the place provided for above, which ensures the conservation of the marks: (a) When the mark is of the self-adhesive type, a space shall be provided on the instrument for the application of the mark. 8. Metro/oglca/ control (1) Verifieatlon (i) Visual inspection Before testing, the instrument shall be visually Inspected for metrologlcal characteristics, l.e., accuracy class, Min, Max e, d. prescribed Inscription and position for verification and control marks. model approval number wherever applicable. (ii) Tests Tests shall be carried out to verify compliance with the following requirements : • clause (I) of sub-para (6) of paragraph 3-Value of maximum permissible error, • sub-clauses (b] and (c) of clause (iii) of sub-paragraph (6) of paragraph 3-Maximum permissible error for net and tare values, • clause (ii) of sub-paragraph (6) of paragraph 3-Scale interval of the tare weighing device, • clause (iii) of sub-paragraph (7) of paragraph 4 operation of the tare device shall be visible. • clause (i) of sub-paragraph (7) of paragraph 3 repeatability (3 weighing on classes III and IV and 6 weighing for I and II) • clause (ii) of sub-paragraph (7) of paragraph 3-Eccentrlc loading • sub-paragraph (8) of paragraph 3- Discrlminatlon (iii) Stamping Verification shall be testified byverification marks. All components whose dismantling or maladjustment might alter the metrological characteristics of the instrument should be secured by a seal. (2) Inspection During inspection the following tests shall be carried: - maximum permissible error; clause (i) of sub-paragraph (6) of paragraph 3, - Eccentric loading; clause (ii) of sub· paragraph (7) of paragraph 3, - the seal applied during verification shall remain intact. 9. Test procedure during verification and Inspection (J) Evaluation of error At a certain load L, the indicated value, I Is noted. Additional weights of say 1/10 e are successively added until the .L--·· 408 iTHE<GAZENE<OF INDIA: EXTRAORDINARY [PARTII-SEC. 3(i)] indlcatlon.,of the instrument'is Increased unambiguously by .one -scaie Interval (I + e), 'The addlticnel.load .Ladded to the load receptor gives the: Indication P, by using the formula P=l+-(l/2)e-t.L The error Is E-= P -,L =I+ (1/2)e-L-.t.L .S: mpe (2)We/ghts (i) The standard .weights used for verification of an· Instrument shall not have an error greater than 1/3 of the maximum permissible.error of the instrument for the applled.lcad. (ii) Substitution of standard weights : While verifying.Instrument with maximum of 1 tonne and more, instead of standard weights, any other constant load may be used,,provlded that standard weights of at least 1 tonne or 50% of maximum, whichever Is greater, is used .. (3) Weighingtests Apply test loads from zero up to and includingMax. and similarlyremove the test loads back to zero. During verification 5 test loads shall be selected and during inspection 3 test loads. The test loads selected shall Include Max., Min and values at or near those at which the maximum permissible error changes. When loading or unloading, the weights shall be progressively Increased or decreased. If the instrument Is provided with an automatic zero setting device, it shall remain In operation during test. Error is calculated as given in sub-para (l)above. (4) Weighing test using substitution method Apply the test loads from zero up to and includingmaximum portion of the standard weights. Determine the error and then remove the weights so that the no load indication, or In the case of an Instrument with a zero tracking device, the Indication of say lOe, Is reached. Substitute the previous weights with substitution material until the same changeover point, as used for the determining of the error is reached. Repeat the above procedure until Max. of the instrument Is reached. Unload in reverse order to zero, i.e. unload the weights and determine the change over point. Place the weights back and remove the substitution material until the same changeover point is reached. Repeat this procedure until no-load is reached. (S) Tare (I) Tare weighing Weighing tests shall be performed at least at two different tare values. At least S steps may be selected includingMin. loads close to values at which mpe changes and the value close to the maximum possible load (or maximum additive tare if provided). (6) Eccentricity test Large weights should be used in preference to several small weights. The load shall be applied centrally in the segment If several weights are used. The location of the load shall be marked on a sketch in the report. The automatic zero-setting device shall not remain in operation during the sets. (I) Instrument with load receptor having not more than four points of supports The four quarter segments roughly equal to 1/4 of the surface of the load receptor shall be loaded in turn. (II) Instruments with a load receptor having more than four points of support The load shall be applied over each support on an area of the same order of the magnitude as the fraction of 1/n of the surface area of the load receptor, where n Is the number of points of support. (Ill) Instrumentwithspeciillloadreceptor(tank, hopper) The load shall be applied to each point of support. (Iv) Instrument used for weighingrollingloads A rolling load shall be applied at different positions on the load receptor. These positions shall be at the beginning, the middle and at the end of the load receptor In the normal driving direction. The positions shall then be tested in the reverse direction. 409 (7) Discrimination test The followingtests shall be performed with three different loads, i.e. Min, 1/2 load and Max. (i) Non-self Indication and analogue fndla,tion An extra load shall be placed gently on or removed from the load receptor while the instrument Is at equilibrium. (ii) Diglti1fIndication : A load plus sufficient additional weights (say 10 times 1/10 of e) shall be placed on the load receptor. The additional weights shall then be removed until the indication, I Is decreased unambiguously by one actual scale interval i.e. I-d, One of the additional weights shall be replaced and a load equal to 1.4 e shall then be placed gently on the load receptor and give a result, Increased by one actual scale interval above the initial Indication, i.e. l+d. (8) Repeatability test Two series of weighing shall be performed; one at 1/2 load and the other at max. Readings shall be taken when the instrument Is loaded and unloaded. (9) Creep test Load the Instrument close to Max. Take one reading as soon as the Indication has stabilized and then note the Indication while the load remains on the Instrument for a period of four hours. During this test the temperature should not vary more than 2°c. The test may be terminated after 30 minutes If the indication differs less than O.Se during the first 30 minutes and the difference between 15 and 30 minutes is less than 0.2e. (1 O) Zero return test The deviation In the zero indication before and after a period of loading with a load close to Max for half an hour, shall be determined. The reading shall be taken as soon as the indication has stabilized. For mulflplerange instruments, continue to read the zero indication during the following 5 minutes after the Indication has stabilized. If the instrument is provided with automatic zero-setting or zero-tracking, it shall not be In operation. · Test for the stability of equilibrium (Instruments with printing and/or data storage devices) Load the instrument up to 50 per cent of Max. Manually disturb the equilibrium and Initiate the command for data printing or data storage as soon as possible. Read the indicated value 5 seconds after printing. Perform the test 5 times. {il) Influence factors (I) nlting The instrument shall be tilted both forwards and backwards longitudinally, and from side to side transversely. In the text that follows, class 11 instrument Intended for direct sales to the public are designated class II* and class II Instrument not intended for direct sale to the public are designated class II. In practice the tests ( no load and loaded) can be combined as follows : After zero setting In the reference position, the indication is determined at no load and at the two test loads. The instrument Is then unloaded and tilted (without a new zero setting), after which the indication at no load and at the two test loads are determined. This procedure is repeated for each of the tilting directions. In order to determine the influence of tilting on the loaded instrument, the Indication obtained at each tilt shall be corrected for the deviation from zero which the instrument had prior to loading. If the instrument is provided with automatic zero-setting or zero tracking, It shall not be in operation. Tilting class II, III and III! instruments (a) Tilting at no-load {class II*, Ill and III!) : The instrument shall be set to zero in its reference position (not tilted). The instrument shall then be tilted longitudinally up to 2/1000 or the limiting value of the level indicator, 410 THE GAZETTE OF !NOIA: EXTRAORDINARY [PARTII-SEC. 3(i)] whichever Is greater. The zero Indication. is noted. The test shall be repeated with transverse tilting. (b) TIiting when loaded (class II, II*, III and III!): The'lnstrument.shall be set to zero In Its reference position and two .weighings ·shall be carrled out at a ·load. close to the lowest load where the :maximum permissible error •changes, ·and at a load close to Max. The instrument is then unloaded and tilted 'longitudinally and set to zero. The ,tiJting shall be 2/1000 or the lfmltlng value of the level Indicator, whichever is greater. Weighing tests as described above shall be performed. The test shall be repeated with transverse tilting. (c) Tiltlng class I instrument : The Instrument shall be tilted longitudinally up to the limitingvalue · of the level indicator. Check the tilt. Repeat with transverse tilting. If the tilt Is not greater than 2/1000, no further testing Is required. Otherwise test as per "tilting when loaded (class II, II* III and III!)" in (b} above. (d} Instrument without level Indicator: For an Instrument liable to be tilted and not fitted with a level indicator the test "tilting class II, III and III!" as given in (a) and (b) shall be performed except that the instrument shall be tilted 5% instead of 0.2%. (12) Wa1771up time test An instrument using electric power shall be disconnected from the supply for a period of at least 8 hours prior to the test. The instrument shall then be connected and switched on and as soon as the indication has stabilized, the instrument shall be set to zero and the error at zero shall be determined. Calculation of error shall be made. The instrument shall be loaded with a load close to Max. These observations shall be repeated after 5, 15 and 30 minutes. For Instruments of class I, the provisions of the operating manual for the time following connection to the mains shall be observed. . · (13) Temperature tests See Figure 32 E for practical approach to performing the temperature tests. (I) Static temperature tests : The test consists of exposure of the equipments under test (EUT)to constant temperatures within the range stated under free air conditions, for a 2 hour period after the EUT has reached temperature stability. The weighing tests (loading and unloading) shall be carried out o at a reference temperature (normally 200c but for class I instruments the mean value of the specified temperature limits); o at the specified high temperature; o at the specified low temperature or at a temperature of soc if the specified low temperature is below 100c; and • at the reference temperature. The change of temperature shall not exceed 1OC/min during heating and cooling down. ' For class I instruments changes In barometric pressure shall be taken into account. The absolute humidity of the test atmosphere shall not exceed 20 g/m3, unless the operating manual gives different specifications. (II) Temperature effect on the no-load Indication : The instrument shall be set to zero and then changed to the prescribed highest and lowest temperature as well as at soc If applicable. After stabilisation the error of the zero indication shall be determined. The change in zero indication per 1°c (class I) instrument or per soc (other Instruments) shall be calculated. The changes of these errors per 1°c (class I Instruments) or per s0c (other Instruments) shall be calculated for any two consecutive temperature of this test. ['11'1I[-? 3(i)J 411 Test severity : Voltage variations : This test may be performed together with the temperature test. The errors at zero shall then be additionally determined immediately before changing to the next temperature and after the 2 hour period after the Instrument has reached stability at this temperature. Note : Pre-loading Is not allowed before these measurements. If the Instrument is provided with automatic zero-setting or zero-tracking, it shall not be in operation. (14) Voltilge variation Stabilize the EUT under constant environmental conditions. The test consists of subjecting the EUT to variations of AC mains voltage. The test shall be perfonmed with test loads of lOe and a load between 1/2 Max and Max. Upper limit v + 10% Lower limit V - 15% Where V is the value marked on the Instrument. Maximum allowable variations : All functions shall operate as designed, and all indications shall be within the maximum permissible errors. If the instrument is provided with an automatic zero-setting or a zero trackingdevice, It may be in operation during the test. (15) Endurance test: (Applicable only to instruments of class II, III and IIII with Max ?100 kg The endurance test shall be performed after all other tests. Under nonmal conditions of use, the Instrument shall be subjected to the repetitive loading and unloading of a load approximately equal to 50% of Max. The load shall be applied 100 000 times. The frequency and speed of application shall be such that the instrument attains an equilibrium when loaded and when unloaded. The force of the load applied shall not exceed the force attained In a nonmal loadingoperation. A weighing test In accordance with the procedure shall be performed before the endurance test is started to obtain the intrinsic error. A weighing test shall be performed after the completion of the loadings to determine the durability error due to wear and tear. If the Instrument Is provided with automatic zero-setting or zero-tracking device it may be in operation during the test. :.? " i " ., • I • !L J Q• II A '!I I.I • " " ? - FIGURE 32E Proposed test sequence for tests given in clauses (i) and (ii) ofsub-paragraph (13) of Paragraph 9 of Part·ll (temperature test where the temperature limits are +40°C / • 10°C) Annex-A ADDffiONAL TESTS FOR ELECTRONIC INSTRUMENTS FOR MODEL APPROVAL J. General requirements for electronic instruments under test (EUT) Energise the EUT for a time period equal to or greater than the warm up time specified by the manufacturer and maintain the EUT energised for the duration of the test. Adjust the EUT as closely as practicable to zero prior to each test, and do not re-adjust it at any time during the test, except to reset It If a significant fault has been Indicated. The deviation of the no-load indication due to any test condition shall be recorded, and any load Indication shall be corrected accordingly to obtain the weighing result. 412 THE GAZETTE OF INDIA: EXTRAORDINARY [PARTII-SEC. 3(i)] The handlingof the instrument shall be such that no condensation of water occurs on the instrument: 2. Performance tests for influence factors 2( 1) Static temperatures. 2(2) Damp heat, steady state (not applfcable to class I instrument or class II Instruments where e Is less than 1 gram). Test procedure in brief : The test consists of exposure of the EUT to a constant temperature and a constant relative humidity. The EUT shall be tested with at least five different test loads. o at the reference temperature (20 °c or the mean value of the temperature range whenever 20°c is outside this range) and a relative humidity of 50% following conditioning. o at the high temperature of the range specified In clause (ii) of sub-paragraph (9) of paragraph3 of Part n and a relatiYe humidity of 85%, two days following temperature and humiditystabilization, and o at the reference temperature and relatlYe humidity of 50%. Maximum allowable variations : All functions shall operate as designed. All indications shall be within maximum permissible errors. 3, Power voltage variations Performance tests for disturbances (1) Short time power reductions Test procure In brief : Stabilize the EUT under constant environmental conditions. A test generator capable of reducing the amplitude of one or more half cycles (at zero crossings) or the AC mains voltage shall be used. The test generator shall be adjusted before connecting the EUT. The mains voltage reduction shall be repeated ten times with an Interval of at least 10 seconds. The test shall be performed with test loads of lOe and a load between 1/2 Max and Max. Test severity Reductions 100% 50% Number of half cycles J 2 Maximum allowable variations The difference between the weight Indication due to the disturbance and the indication without the disturbance shall either not exceeds eor the instrument shall detect and react to a significant fault. (2)Burst The test consists in exposing the EUT to specified bursts of voltage spikes. Before any test stabilize the EUT under constant environmental conditions. The test shall be applied separately to: power supply lines, l/0 circuits and communications lines, If any. The test shall be performed with test loads . of 10 e and a load between 1/2 Max and Max. Test severity : Open circuit output test voltage for: o power supply lines 1 kV e I/0 signal 1, data and control lines O.SkV. Maximum allowable variations : The difference between the weight indication due to the disturbance and the indication without the disturbance shall either not exceeds e or the Instrument shall detect and react to a significant fault. (J) Electrostatic discharge The test, consists in exposing the EUT to specified, direct and Indirect, electrostatic discharges. This test includes the paint penetration method, if appropriate, for direct discharges the air discharge shall be used where the contact discharge method cannot be applied. Before any test stabilize the EUT under constant environmental conditions. At least 10 direct discharges and 10 Indirect discharges shall be applied. The time interval between successive discharges shall be at least 10 seconds. The test shall be performed with test loads of lOe and a load between 1/2 Max. and Max. Maximum allowable variations : The difference between the weight indication due to the disturbance and the indication without the disturbance shall either not exceeds e or the instrument shall detect and react to a significant fault. [ '!ll'T ll -111"6 3 ( i) ] 413 (4) Immunity to radiated electromagnetic fields The test consists in exposing the EUT to specified electromagnetic fields. Before any test, stabilize the EUT under constant environmental conditions. The EUT shall be exposed to electromagnetic fields of the strength and character as specified by the severity level. The test shall be performed with one small test load only : Frequency range 26-1000 MHz Field strength 3 V{m Modulation 80% AM 1 kHz sine wave Maximum allowable variations : The difference between the weight Indication due to the disturbance and the Indication without the disturbance either shall not exceed e or the instrument shall detect and react to a significant fault. 4. Span stability test (Not applicable to class I instruments) Test procedure In brief : The test consists in observing the variations of the error of the EUT under sufficiently constant ambient conditions (reasonably constant conditions In a normal laboratory environment) at various Intervals before, during and after the EUT has been subjected to performance tests.: The performance test shall Include the temperature test and If applicable, the damp heat test; they shall not lndude any endurance test; other performance test In this Annexure and In paragraph 9 shall be performed. The EUT shall be disconnected from the mains power supply, or battery supply where fitted, two times for at least 8 hours during the period of the test. The number of disconnections may be Increased If the manufacturer specified so or at the discretion of the approval authority In the absence of any such specification. For the conduct of this test the manufacturer's operating instructions shall be considered. The EUT shall be stabilised at sufficiently constant, ambient conditions after switch-on for at least 5 hours, but at least 16 hours after the temperature and damp heat test have been performed. Test duration : 28 days or the period necessary for the performance tests to be carried out, whichever Is shorter. nme between measurements : Between 1/2 and lOdays. 47!.f,; ,711-/oq Test load : Near Max : The same test weights shall be used throughout this test. Number of measurement at least 8. Test sequence : Stabilize all factors at sufficiently constant ambient conditions. Adjust the EUT as close to zero as possible. Automatic zero-tracklnq shall be made Inoperative and automatic bullt In span adjustment device shall be made operative. Applythe test weight(s)and determined the error. At the first measurement Immediately repeat ·zeroing and loading four times to determine the average value of the error. For the next measurements perform only one unless either the result is outside the specified tolerance or the range of the five readings . of the initial measurements Is more than O. le. Record the following data:­ (a) data and time (b) temperature (c) barometric pressure (d) relative humidity (e) testload (f) Indication (g) errors (h) changes in test locations and apply all necessary corrections resulting from variations of temperature, pressure, etc. between the various measurements. Allow full recovery of the EUT before any other test is performed. Maximum allowable variations The variation in the errors of indication shall not exceed half the verification scale interval or half the absolute value of the maximum permissible error on initial verification or the test load applied, whichever is greater, on any of the nmeasurements. Where the difference of the results indicate a trend more than half the allowable variation specified above, the test shall be continued until the trend comes to rest or reverses itself, or until the error exceeds the maximum allowable variation. · SEVEN1lt SOIEDUU: HEADING-B. (see rule 13) GENERAL REQUIREMENTS J. category Weighinginstruments of the following categories are included In this Part: (a) Beam Scales (b) Counter Machines 414 THE GAZETTE OF INDIA: EXTRAORDINARY [PARTII-SEC. 3(i)] 2. Constructions (a) Weighing instruments .shall .be of such materials, design and construction that under normal conditions of.service: (I) They maintain accuracy. (ii) They function·satisfactorlly without the need forfrequent adjustment. (iii) Excessive stresses ·do not develop In the vital parts. (b) The pivots, :knife-edges and bearings, wherever ·used shall be of agate or suitabJe,hard,material or of suitable quality steel. i1'he•steel 'knife-edges and bearings shall have,the 'hardness specified below: (i) For 'beam scale of classes C and D and with capacities 10kg. and below not less than 54 Rockwell C. (ii) .F.Gr·other weighing instruments-60 to 66 Rockwell C. (c) The pivots, knife-edges and bearings shall be protected against corrosion and dirt. 3. Marking (a) All weighing Instruments shall carry the followingmarkings:- (i) manufacturer's name, or his registered trade mark. (ii) to weight kg, or g as appropriate. (iii) dass, wherever applicable. Note : The manufacturer's name or registered trade marks shall be such as will not be mistaken for the stamp or seal of the verification authority. (b) The markings shall be indelible and of a size, shape and clarity allowing easy reading under normal conditions of use of the Instruments. (c) All numerals appearing on weighing instruments shall be international form of Indian numeral. 4. Sealing All weighing Instruments shall be provided by the manufacturers with a plug or stud of soft metal to receive the stamp or seal of the verification authority. Such plug or stud shall be provided in a conspicuous part of the Instrument and shall be made in such a manner as to prevent Its removal without obliterating the seal. PART I BEAM SCALES J. Definitions (a) Beam Scale-A weighing instrument with equal arms having three knife edges, three bearings, an indicator (pointer) in the centre, and pans suspended from the end knife-edges. (b) Sensitivity figure-It is expressed in terms of milligrams per division. (c) Sensitiveness-It is expressed as the least weight, required to be added to or removed from one of the pans, to cause a visible displacement of the pointer from Its position of equilibrium. Note : 1. Sensitivity figures shall be determined only for those beam scales which have a pointer with sector plate. For other beam scales the sensitiveness test shall apply. 2. All class 'A' beam scales shall be provided with a pointer with sector plate or the scale. (d) Error (Due to inequality of arms)-The error due to inequality of arms of a beam scale under specified load conditions Is equal to the mass of the additional weights required to bring to equipoise the balance, carrying weights of equal masses In the pans. (e) Greatest Error (Due to Inequality of Arms)-The greatest error due to Inequality of arms Is the error determined with two weights each equal to the capacity (full load) of the balance. 2. Classes and Capacities (a) Beam scales shall be of any one of the four classes namely, A, B, C or D, based on limits for sensitivity figure/sensitiveness and greatest error specified in Tables 21-A to 21-D, respectively. (b) Beam scales of the different classes shall · be of one of the capacities mentioned in Tables 21-A to 21-0. (c) The trades for which the different classes of scales may be used are: Class of Scale Use A * Commercial assay and in 'Dharam Kanta' for verifying the weights of bullion and precious stones. · B Precious stones, jewels, pearls, bullion, precious metals, saffron and similar expensive commodities, chemists and druggists preparations, perfumery, etc. C Base metals and commodities such as cereals, tea, coffee, tobacco, Jute, cotton, dry fruits, spices, oil seeds, etc. D Welghment of cheaper commodities such as scrap iron, fuel, wood, charcoal, vegetables, etc. * Single pan balances may also be used in place of Class A or B beam scales. (For tests to be conducted on such balances see annexure at the end of this psrt.) ·····-?-···•···' .... _ t .. - ·-··--- •. ['WT II-? 3(i)] <nm efiT = : a:mT"lR"T 415 TABLE 21 A UM!TS FOR SENSITIVITY FIGURE AND GREATEST ERROR FOR BEAM SCALES Class'A'. eaeacity Verification Inspection SenSltlVlty figure per Greatest error 1 Sensitivity figure per Greatest error division of scste at no allowed when division of scete at no aflowed when 108d and at full toad full'[_loaded , load and at fut/ load fufl"t_loaded . 1 2 3 4 5 m m m m 2g 0.02 0.04 0.06 0.08 5g 0.05 0.10 • 0.15 0.20 10 g 0.10 0.20 , 0.30 0.40 - 20 g 0.20 0.40 I 0.60 0.80 50 g 0.50 1 ' 1.5 2 100 g 1 2 . 3 4 200 g 2 4 6 8 500 g 5 10 , 15 20 1 kg 10 20 , 30 40 2 kg 20 40 60 80 5 kg 30 60 90 120 10 kg 50 100 150 200 20 kg 100 200 300 400 50 kg 200 400 600 800 TABLE 21 B LIMITS FOR SENSITIVENESS AND GREATEST ERRORS FOR BEAM SCALES Ci1eacity 1 2 g 5 g 10 g Class'&'· Verification Inspection Sensitiveness Greatest error Sensitiveness Greatest error at luff load allowed when at full load allowed when fulf't_loaded ? I fully loaded 2 3 4 5 1 mg 2 mg 3 mg 4 mg 2 mg 4 mg 6 mg 8 mg 3 mg 6 mg 9 mg 12 mg --- ---· - ----- -------?-- - _j ---------- 416 THE GAZETTE OF JNDIA:EXTRAORDINARY [PARTJI-SEC. 3(i)] 1 2 3 4 5 20/ 5.mg 10mg 15 mg 20 mg . so g 10 mg 20 mg 30 mg 40 mg 100 g 20 mg 40 mg 60 mg 80 mg 200 g 30 mg 60 mg 90 mg 120 mg 500 g 50mg 100 mg 150 mg 200 mg 1 kg 100 mg 200 mg 300 mg 400 mg 2 kg 2.00 mg 400 mg 600 mg 800 mg 5 kg 300 mg 600 mg 900 mg 1.2 g 10 kg 500 mg 1 g 1.5 g 2 g 20 kg 1 g 2 g 3 g 4 g 50 kg 2 g 4g 6g 89 100 kg 5 g 10 g 15 g 20 g 200 kg 10 g 20 g 30 g 40g TABLE 21 C UMITS OF SENSmVENESS AND GREATEST ERRORS FOR BEAM SCALES C11e.acity Verification I nse.ection Sensitiveness Greatest error Sensitiveness Greatest error at full load allowed when at fully load allowed when fully loaded I full.f..loaded 1 2 3 4 5 100 g 100 mg 200 mg 300 mg 400 mg 200 g 200 mg 400 mg 600 mg 800 mg 500 g 500 mg 1 g 1.5 g 2 g 1 kg 1 g 2 g 3g 4 g 2 kg 2 g 4g 6g 89 5 kg 3g 6g 9g 12 g 10 kg 5 g 10 g 15 g 20 g 20 kg 10 g 20 g 30 g 40 g 50 kg 15 g 30 g 45 g 60 g 100 kg 25 g 50 g 75 g 100 g 200 kg . 50 g 100 g 150 g 200 g 300 kg 75 g 150 g 225 g 300 g 500 kg 100 g 200 g 300 g 400 g 1000 kg 150 g 300 g 450 g 600 g ['IWTII ?3(i)J TABLE21D LIMITS OF SENSffiVENESS AND GREATEST ERRORS FOR BEAM SCALES 417 (a) Material for Class A Beam Scales-Class A beam scales shall be made of non-magnetic materials only, except knife-edges and bearings. (b) Material for other Class of Beam Scales­ Beams and pans shall be made of stain less steel, mild steel, brass or bronze. Aluminium alloy may be used in balances, having a capacity of not more than 50g. The pans of Class B beam scales may be made of glass also. In the case of beam scales of Classes C and D, pans of hard-wood shall be permitted for capacities 100 kg. and above. The pans of beam scales, when made of timber, shall be adequately reinforced and protected against wear. Sensitiveness at full load g 1 2 5 5 10 10 20 20 50 30 100 50 200 100 300 150 500 200 1000 300 3. Materials capacity Verification Class'D' Inspection Greatest error Sensitiveness at full Greatest error allowed when load allowed when fully loaded fully loaded g 3 4 5 10 15 20 20 30 40 40 60 80 60 90 . 120 100 150 200 200 300 400 300 450 600 400 600 800 600 900 1200 (c) Suspension-Pans shall be suspended from the beam by metal chains through stirrups, hooks or rings. In the case of Class B beam scales of capacity 100 g or less, the pans may be suspended by sll k or nylon th reads. (d) All mild steel parts used In beam scales shall be suitably protected against rust. · 4. Construction (a) Knife-edges and Bearings (i) The knife-edges and bearings used in beam scales shall be of one of the following types:- Agate-bo-Whereln agates bearings are fitted in a brass or iron box, with side holes which permit the projecting ends of the knife-edges to pass into the boxes and rest on or rise to their bearings (See Fig· 33 A). BEAM AGATE BOX BEAM FIGURE-33 A 418 THE GAZETTE OF INDIA:EXTRAORDINARY [PART!I--SEC. 3(i)] Dutch-end-Wherein the end bearings are fixed inside plates bolted together across the'beam to form a shackle (See Figure- 33 B) DlJfCH-END BEAM FIGURE·33B Swan-neck-4Vherein the ends are curved and slotted, the bottom of the slot forming a knife-edge, the extremities of the beam being widened In direction at right angles to its length so that the base of the slot is parallel to the central knife-edge (See Figure SS·H). SWAN NECK BEAM FIGURE·33C BEAM Continuous knlfe-edge'-Whereln the knife- edges bear along their whole length (See Fig 33 D) COtffiNUOUS KNIFE FIGURE33D ------------ - ------- 419 (ii) Class A beam scales shall have continuous knife-edgesand shall be provided with means for rellevlng all the knife-edges from the bearings. (iii) aass 6, beam scale shall not have swan­ neck fittings. (b) Glass Case- Eveiybeam scale of aass A shall be provided with a glass case. It shall also be provided with bubble or a plumb line and levelling screws to facilitate levelling of the Instrument. (c) Leading Dimensions (I) No dimensions have been specified for Class A beam scales. (II) Beam scale of Classes 6, C and D shall have the leading dimensions specified in Tables 21 E to 21 I and Figure 33 E to 33 I as applicable to within the tolerances specified In 4(d). For Class C beam scales of capacities 5 kg and below fixed hooks mayalso be provided. TABLE21E LEADING DIMENSIONS OF BEAM Class B (withpointer above the beam) Capacity Length between ends Depth at the centre Thickness of plate at the (Nominal) (Nominal) centre (Nominal) L D T 1 2 3 4 mm mm mm FLAT1YPE 2g 70 10 2 5g 95 12 2 10g 110 15 2 20g 120 20 3 50g 135 22 3 100g 150 25 4 200g 170 25 5 500g 200 30 5 1 kg 250 40 6 2 kg 300 45 6 5 kg 450 50 6 10 kg 500 58 8 20 kg 600 58 10 so kg 750 100 15 100 kg 1000 110 18 200 kg 1250 125 25 OPEN PAmRN (BRIDGE)1YPE 200g 170 25 5 SOOg 260 37 5 1 kg 310 44 5 2 kg 350 48 5 5 kg 450 60 6 10kg 500 70 8 20 kg 600 80 10 50 kg 750 120 15 100kg 1000 150 20 420 THE GAZETTE OF !ND!A:EXTRAORDINARY [PARTTI-SEC. 3(i)] TABLE21F LEADING DIMENSIONS OF BEAM Class B (Flat and Open Pattern Type with pointer below the beam) Capacity Length between the ends Depth at the centre Thickness of plate at the (Nominal) (Nominal) centre knife edge (Nominal) A L D T 1 2 3 4 mm mm mm 2g 70 3 2 5g 95 3 2 10g 110 4 2 20g 120 20 3 50g 135 20 3 100g 150g 20 4 200g 200 20 6 500g 235 25 8 1 kg 300 30 8 2 kg 320 30 8 5 kg 350 32 10 10 kg 400 40 12 20kg 500 50 14 50kg 700 70 18 100kg 800 80 20 200kg 1250 125 25 TABLE21G LEADING DIMENSIONS OF BEAf1 Class C (Swan Neck Type) Capacity Length between the Depth at the centre Thickness of plate at the ends (Nominal) (Nominal) centre knife edge (Nominal) L D T 1 2 3 4 mm mm mm 100g 150 30 4 200g 200 40 s 500g 300 40 6 1 kg 350 45 6 2kg 400 45 6 5 kg 550 70 6 10kg 600 80 6 20 kg 750 108 8 50 kg 900 116 8 100 kg 1200 138 14 200kg 1350 148 16 300kg 1650 154 18 500kg 1800 178 25 1000 kg 2000 200 32 . ,- 1 . ['fill n-= 3( i) l TABLE21H I LEADING DIMENSIONS OF BEAM Class C (Dutch End Type) 421 Capacity Length between end Depth at the centre Th lckness of plate at the knife-edges (Nominal) knife-edge (Nominal) (Nominal) L D T 1 2 3 4 mm mm mm 100g 150 35 4 200g 200 40 5 500g 300 40 6 1 kg 350 45 6 2 kg 400 45 6 5 kg 450 70 6 10 kg 450 75 8 20 kg 600 75 8 50kg 750 80 8 100kg 900 120 14 200 kg 900 133 16 300kg 1050 142 16 500kg 1350 192 20 1000 kg 1650 203 25 TABLE21 I LEADING DIMENSIONS OF BEAM Class 'D' • Capacity Length between the end Depth at the centre Thickness of plate at knife-edges (Nominal) (Nominal) the centre (Nominal) L D T 1 2 3 4 kg mm mm mm SWAN-NECK WITH FIXED FLAT HOOKS 5 550 70 6 10 600 80 6 20 750 108 6 50 900 116 8 100 1200 138 14 200 1350 148 16 300 1650 154 18 DETACHABLE FLAT HOOKS 500 1800 178 25 1000 2000 200 32 4 7 lf c; o) 11 - f o G 422 THE .GAZETTE OF. INDIA: EXTRAORDINARY [PARTII-SEC. 3(i)] BEAM SCALE CLASS B (FLAT TYPE) .· FIGURE-33E ,...- X -·----- ---------- .SEAL' --- - --'·y'-- .; __ -- - -. &-?????- L ?? SECTI0NXX BEAM SCALE CLASS C (DUTCH END TYPE) F1GURE-3JF TI SECTION XX i:J SEAL ,]( BEAM SCALE CLASS C (SWANNECK WITH SEPARABLE FLAT HOOKS FIGURE33G [ '11'1 II -1'.si"s 3 ( i ) ] FIGURE-33G 423 T SEAL D ?-----·_.;_ L --- X ·X T SECTION XX BEAM SCALE CLASS B (OPEN PAITERN TYPE) FIGURE-33H X <> tl====?\r·..1,....-,-x----t- APROX -M;+i,,.2,,...-? APROX 5T010MM 2HOLES BEAM SCALE CLASS D (SWAN-NECKWITH FIXED FLAT HOOKS) FIGURE33 I. Note: Oass D beam scales shall be dlstJnguished from Class C scale by the existence of two Identical holes 5 to 10 mm in diameter through the beam, one on either side of the central knife-edge. (d) Permissible variation In Dimensions-The dimensions of the beam scales shall not vary by more than 10 per cent of the dimensions prescribed In Tables 21 E to 21 I. · (e) Attachment for Adjusting the Balance of a Beam scale-Beam scales of Classes B, C and D may be provided with a balance ball or balance box securely attached to one of the suspended chains or· pans in such a manner that it is not possible to alter it easily. The balance ball or balance box shall not be so large as to contain more loose material 424 THE GAZETTE OF INDIA: EXTRAORDINARY [PART!I-SEC. 3(i)) than an amount exceeding one.percent in weight of the capacity of beam scales under 100 kgor an amountexceedlng.lkg for.beam scale of qipaclty 100 kg and above. (f) Arrangement adjustir,g sensitivity figure-­ Beam scales- of Class. A shall 'be provided with an .attachment for adjusting the sensitivity figure. Beam scales of other classes shall not be provided with an attachment to adjust their sensitiveness. (g) For the purposes of postal transactions Class C beam scales may be provided with an open type pan as illustrated in Figure 33 J. OPEN TYPE PAN FIGURE33J 5. Tests (a) Test for sensitivity figure or sensitiveness Only -Class W beam scales shall be tested for sensitivity figure. The sensitivity figure shall be determined at zero and full loads and shall comply with the requirements specified in Table 43-B, Beam scales other than Class W shall be tested for sensitiveness at full load only and shall comply with the requirements specified in Tables 43-C to 43-E. (i) Class A Beam Scales-For determining the sensitivity figure of a Class A beam scale at no load, the beam scale shall be properly balanced without any load In the pans. A small weight whose mass Is accurately known shall be put on one of the pans. This small weight shall be so chosen that the turning points of the pointer remain within the reading Index. The rest point shall be determined by the usual oscillation method. The weight sha!I then be transferred to the other pan and the second rest point shall be determined. If the rest points shift by 'n' divisions on the scale and if the mass of the test weight Is 'w' mg., the sensitivity figure 's' in mllligrams per division, at no load, is given by the relation: s = 2w/n. A similar test with appropriate weights in each pan representing the full capacity of the beam scale, shall be performed to determine the sensitivity figure of the beam scale at full load. (II) Class A beam scales 2g to 20g-As it is not practicable to make weights of denominations smaller than one milligram, the sensitivity figure of beam scales of smaller capacities, that is, from 2 g to 20 g shall be determined by means of a pair of weights, each weight having a mass of approximately 5 mg. The difference in the masses of the two weights of the pair shall be adjusted to be of the order of 0.05 mg, 0.12 mg., 0.25 mg, or 0.5 mg depending on the beam scale under test, that is, for testing 2 g, 5 g, 10 g or 20 g, beam scale, respectively.This difference should be known accurately. After balancing the beam scale at zero load, one of the two weights in the pair shall be put on the right pan and the other weight on the left pan. The rest point shall be determined. The two weights shall then be inter-changed and the second rest point shall be similarly determined. If the rest point shifts by 'n' divisions and if the ['WT II-? 3(i)) 425 difference between the masses of the two test weight Is 'w' mg., the sensitivity figure 's' of the beam scale in milligrams per division at zero load Is given by the relation: s = 2w/n. To determine the sensitivity figure of the beam scale at full load a similar test shall be performed with weights equal to the maximum capacity of the beam scale in each pan. (iii) Beam scales other than class A-Pans of a beam scale other than Class A, shall be loaded with weights representing Its full capacity and the scale is balanced. Weights of such mass shall then be added on one of the pans as may move the tip of the pointer from its equilibrium position by an appreclable distance. After removing these weights the same test shall be repeated on the other pan and the weights required for movingthe tip of the pointer by the same distance on the other side of the equilibrium positionshall then be added. If these weights are denoted by 'wt' and 'w2' respectively, the sensitiveness "s" of the beam scale is given by the relation: s=?1?2 2 (b) Inequality of Arms Test (i) Class A Beam Scale-The error due to inequality of arm of Class A beam scale shall be detenmlned by the following method. The beam scale shall be properly balanced without any load In the pans. The rest point (R,) shall be determined by the usual oscillation method. After arresting the beam both the pans shall be loaded with equal weights of same material and representing the full capacity of the beam scale. The beam scale shall then be properly balanced by adding small weights. The rest point (R,) shall be determined by the oscillation method. After arresting the beam, the loads, including the small weights, shall be interchanged and scale balanced again by putting additional weights (m), if necessary on one of the pans. The rest point (R,)shall again be determined. The error (E) caused due to Inequality of the arms of the scale is given by E= m + IB1±R? 2 2 where 5 is the sensitivity figure of the beam scale. ti 7 'f "' /J If - Io 7 (ii) Beam scales other than Class A-In the case of beam with fixed hooks the beam with hooks but without chains and pans shall be checked for balance. If detachable hooks are provided the beam alone shall be checked. The loose hooks shall then be attached and the assembly checked for balance. The chains and pans shall then be attached In the case of both the types of balances and checked again for balance. After checking at no load, each of the pans shall be loaded with weights equal to the maximum capacity of the beam scale and the scale shall be balanced. The loads thereon shall then the interchanged and the beam scale balanced again by adding necessary weights on one of the pans. The additional weight shall be equal to twice the error due to inequality of arms of the beam. In the case of beams with attached hooks, the loads shall be Interchangedalong with the chains, and pans and In the case of beams with detachable hooks the loads shall be interchanged along with the hook chains and pans. (Ill) The figure so obtained shall be halved to determine the error at full-load. These should be within the limits specified in Tables 43-B to 43-E. (c) Shift 7eslc--Beam scales other than Class A-,­ With the pans loaded to half the capacity, no appreciable difference in the accuracy of the instrument shall result from moving the knife-edges or bearings laterally or backwards and forwards within their limits of movement. Similarlywhen the above load is moved to any position on the pan, the difference shown shall not be appreciable. Note: The words 'appreciable difference' shall mean 'a difference which can be detected', but the Legal Metrology Officer should exercise his discretion in each particular case. 6. S'1aflng All beam sea les sha JI be provided by the manufacturer with a plug/plugs or stud/studs of soft metal to receive the stamp or seal of the verification authority. Such plug/plugs or stud/studs shall be provided In a conspicuous position and shall be made In such a manner as to prevent its removal without obliterating the seal/seals.

Previous and next

All provisions of Legal Metrology (General) Rule, 2011

Questions people ask

Is annexure D of Legal Metrology (General) Rule, 2011 still in force?

No repeal of Legal Metrology (General) Rule, 2011 is recorded.