Rule 112, The West Bengal Municipal (Building) Rules, 2007: Maximum 'lumber of floor
The West Bengal Municipal (Building) Rules, 2007 - Rule 112
Text of rule 112
Maximum 'lumber of floor
112. Maximum 'lumber of floor.—
(1) Maximum number of floors to be built up shall be as follows:—
Area of Plot Maximum no. of Floors allowed
2K G Plus 1
3K G Plus 1
4K G Plus 2
5K G Plus 2
6K G Plus 3
7K G Plus 3
8K G Plus 4
9K G Plus 4
10K G Plus 7
Any plot specified
in sub-rule (2) of
rule 93.
G Plus 1
G means Ground floor
54 THE KOLKATA GAZETTE, EXTRAORDINARY, FEBRUARY 14, 2007 [PART I
(2) So far as the restrictions to the number of storeys to be permitted in the buildings are concerned, the parking
floor in the main building at ground level up to 2.25 m in height from garage floor level to the beam soffit will not be
considered as floor, and will not be taken into consideration for the purpose of calculation of F. A.R.
(3) One mumti or a stair cover above the permissible number of storeys will be allowed in each of the buildings and
this will not be covered by the rule of floor area ratio. The overall height of stair cover shall not exceed 2.85 m.
(4) The overall height of all tall buildings including the Mast should not exceed the approval accorded by the
Airport Authority of India.
Note.—parking space at ground level shall be provided in all buildings including co-operative buildings, on any plot
of 4 cottah or above, the maximum clear floor height of such parking space shall be 2.25 m. The height shall be measured
from the ground level to the beam soffit level of ground floor slab (the ground floor) being the floor just above the parking
space. Such parking space shall not be taken into account to calculate the permissible floor area ratio.
Previous and next
All provisions of The West Bengal Municipal (Building) Rules, 2007
Questions people ask
Is rule 112 of the West Bengal Municipal (Building) Rules, 2007 still in force?
No repeal of the West Bengal Municipal (Building) Rules, 2007 is recorded.