Rule 111, The West Bengal Municipal (Building) Rules, 2007: Floor Area Ratio (F.A.R.)
The West Bengal Municipal (Building) Rules, 2007 - Rule 111
Text of rule 111
Floor Area Ratio (F.A.R.)
111. Floor Area Ratio (F.A.R.).—
(1) Permissible floor area ratio shall be as follows:—
Area of Plot Floor Area Ratio
2K 1.25
3K 1.25
4K 1.75
5K 1.75
6K 2.10
7K 2.10
8K 2.25
9K 2.25
10K 3.20
Permissible for
institutional, industrial
and Commercial
Buildings
2.75
Note.—For IT and ITES Buildings, FAR of 5.9 shall be permitted. However, in such building minimum 80% of the
built up space shall have to be utilized for IT or ITES activities and condition stipulated by the State
Government or ULB has to be adhered to.
Exemptions in calculation of FAR should be as per provisions laid down in-Rule 53 (b).
Any plot specified in sub-rule (2) of rule 93, Floor Area Ratio shall be 1.35.
Explanation.—Floor area ratio, for the purpose of this rule, is the ratio of the total area of all the floors including the
areas of walls, passages, staircase blocks, sanitary blocks, etc. of a building and accessory buildings to the gross area of
plot.