Section 99, The Building and other Construction Workers‘ (Regulation of Employment and Conditions of Service) Act, 1996
The Building and other Construction Workers‘ (Regulation of Employment and Conditions of Service) Act, 1996 (27 of 1996) - Section 99
Text of section 99
99. Pipe and Pumps:-The employer shall ensure at a construction site of a
building or other construction work that—
(a) a scaffolding carrying a pipe for pumped concrete is strong
enough to support such pipe at time when such pipe is filled
with concrete or water or any other liquid and to bear all the
building workers who may be on such scaffold at such time,
safely;
(b) every pipe for carrying pumped concrete is—
(i) securely anchored at its end point and at each curve on
it;
(ii) provided near the top of such pipe with an air release
valve; and
(iii) securely attached to a pump nozzle by a bolted collar or
other adequate means;
58 The Building and Other Construction Workers‘ Rule 100
(Regulation of Employment and Conditions of Service)
Central Rules, 1998
(c) the operation of concrete pumps are governed by standard
signals relevant in accordance with the relevant national
standards;
(d) building workers employed around a concrete pump wear safety
goggles.