Form D, THE UTTAR PRADESH BOILER RULES,1969: FORM D
THE UTTAR PRADESH BOILER RULES,1969 - Form D
Text of form D
FORM D
FORM D
(See RULE 29)
Report into the investigations of the accident to Boiler
To,
THE CHIEF INSPECTOR or Bonza$
Urriu? PRADESH,
KANPUR
Su;
In accordance with the instructions, I have held a preliminary enquiry into the
accident and the ciraunstances attending it to Boiler now make the
following reports:
1. Data and place of accident
2 Date of investigation
& Name and address of owner
4. Persons Wiled or injured
6. Name of Maker
8. Short description of the boilers general condition, Its location with respect
of other boilers, the purpose for which it is used and the age of the boiler.
7. Particulars of previous repairs with date
& The boiler was last inspected on by
9. Nature of accident
10. Cause ofaccident
11. crelfieVidirThWks
Inspector of Boilers; Uttar Pradesh
Remarks by the Chief Inspector of Boilers, Uttar Pradesh
Form
Application for qualification tests for welders engaged in welding of
boilers and steam pipes under construction, erection and
fkbrication at site in India and in repairing
Tboilers and steam pipes by welding
q
The Chief Inspector of Boners,
Uttar Pradesh,
Kanpur.
Sir,
I beg to apply for test as qualified Welding Operator and submit below details as
required. Testimonials of my experience supported by my employer together with
one copy of each are sent herewith
2 Two copies of rrty photograph in a passport size are enclosed
Yours Mithitilly, (Applicant)
1. Full name of applicant (in block letters)
2. Age of applicant _________ Date of birth
3. Nationality ______________________
4. Permanent address _______________
5. Details of applicant's service as a-Welder
(Full details together with exact period for which the candidates was
emplqysdand capacity in which employed must be given. Each such statement
must be supported by applicant's employer or employers).
6. Details of previous tests at which candidate has appeared and failed
(Candidate must state name of testing authority before whom he appeared
Eu4on which count he was declared felled).
I desire to be tested in the Electric Arc/Plate Welding/Pipe
Welding/Tube Welding/Oxaetylene process of welding.
Date ------------------------- Signature of applicant.
c.
FORM 'F
(Vide Rum 19
(8) (g))
Declaration of
Inspector
Registered Description Repairs and Purpose Boiler Date of Date of Limit of Date of
Remarks
number of and material alteration For which rating last inspection wonting
hydraulic .
boilers when and since last used hydraulic PresSure teat of
where made inspection test and boilers insteam pipe
pressure lb. per a4
applied in (4./cm. 2)
1 2 a 4 b 6 T 8 9 10
I hereby declare, viz. :
(1) That the abovenamed boiler was duly inspected by me on the ______________________
and found to be in accordance with the rules and requirements of the Indian Boilers Act, 1923 (Act V, of
1923).
(2) That the boiler with attached steam pipes is in charge of a __________________________
and is not so exposed as to be dangerous. -
(3) That the said boiler will, in try judgment be safe for a period of ______________________
months at a working pressure, which is on no account to exceed the pressure stated in column 8 of this
form.
Dated at ________________________________
This _______________ day of _______________ 19
Inspector of Boilers, Uttar Pradesh
Note— The original rules were published with Government notification no. 4792 (ID)/ moon-A
1050 (TD)
1
-64, dated September 17, 1969 and amended vide following, notifications.
(1) No. 2291/XXXVI-3---1105 (V)-74, dated February 1, 1986
(2) No. 4032/XXXVI-3-12 (B)-89, dated November 16, 1990
(3) No. 2426/XXXVI-3-5 (B)-89, dated July 14, 1992