External inspection of economiser
21. External inspection of economiser :- (a) After the economiser has been
cleaned, the Dy. Director shall make a thorough examination so far as its
construction permits. The external condition of the tubes shall be carefully noted
for wasting especially at the feed inlet end and all accessible tubes shall be
calipered. The internal surfaces of cast iron tubes shall be calipered as far as
possible and shall be closely observed for graphitic wasting. In the event of any
failure, these shall be broken up for scrutiny, so that the general internal
condition of the other tubes may be estimated.
(b) Where tubes or other parts are wasted, the strength shall be recalculated.
(c)The scraper gear shall be examined to note if any parts are missing, if the
length of travel is adequate and if the scrapers are correctly adjusted.
(d) All cap bolts are to be inspected, also the condition and position of the
damper and baffles.
(e) The record of each inspection and calculation shall be entered in the
memorandum of Inspection Book.
Previous and next
Questions people ask
Is rule 21 of the Maharashtra Economiser Rules, 1965 still in force?
No repeal of the Maharashtra Economiser Rules, 1965 is recorded.