Rule 23, The Maharashtra Factories Rules, 1963: When artificial humidification not allowed
The Maharashtra Factories Rules, 1963 - Rule 23
Text of rule 23
When artificial humidification not allowed
23. When artificial humidification not allowed.-There shall be no artificial
humidification in any room of a cotton spinning or weaving factory-
(a) by the use of steam during any period when the dry bulb temperature of
that room exceeds 85 degrees:
(b) at any time when the wet bulb reading of the hygrometer is higher than that
specified in the following Schedule in relation to the dry bulb reading of the
hygrometer at that time; or as regards a dry bulb reading intermediate
between any two dry bulb readings indicated consecutively in the Schedule
when the dry bulb reading does not exceed the wet bulb reading to the
extent indicated in relation to the lower or of these two dry bulb readings:-
Dry bulb Wet bulb Dry bulb Wet bulb Dry bulb Wet bulb
60.0 58.0 77.0 75.0 94.0 86.0
61.0 59.0 78.0 76.0 95.0 87.0
62.0 60.0 79.0 77.0 96.0 87.5
63.0 61.0 80.0 78.0 97.0 88.0
64.0 62.0 81.0 79.0 98.0 88.5
65.0 63.0 82.0 80.0 99.0 89.0
66.0 64.0 83.0 80.5 100.0 89.5
67.0 65.0 84.0 81.0 101.0 90.0
68.0 66.0 85.0 82.0 102.0 90.0
69.0 67.0 86.2 82.5 103.0 90.5
70.0 68.0 87.0 83.0 104.0 90.5
71.0 69.0 88.0 83.5 105.0 91.0
72.0 70.0 89.0 84.0 106.0 91.0
73.0 71.0 90.0 84.5 107.0 91.5
74.0 72.0 91.0 85.0 108.0 91.5
75.0 73.0 92.0 85.5 109.0 92.0
76.0 74.0 93.0 86.0 110.0 92.0
The Maharashtra Factories Rules, 1963 103
Provided, however, that clause (b) shall not apply when the difference between
the wet bulb temperature as indicated by the hygrometer in the department
concerned and the wet bulb temperature taken with a hygrometer outside in the
shade is less than 3.5 degrees.