LawGrids logoLAWGRIDS.ORG

Rule 22, The Maharashtra Factories Rules, 1963: Disposal of trade waste and effluents

The Maharashtra Factories Rules, 1963 - Rule 22

Text of rule 22

Disposal of trade waste and effluents

22. Disposal of trade waste and effluents.-(1) In the case of a factory where the drainage system is proposed to be connected to the public sewerage system, prior approval of the arrangements made shall be obtained from the Local Authority. 1[(2) For the areas notified under Water (Prevention and Control of Pollution) Act, (6 of 1974) necessary approval to arrangements made for the treatment and disposal of all types of trade-waste and effluents shall be obtained from Maharashtra Water (Prevention and Control of Pollution) Board, constituted under that Act.] 2[3] In the case of factories other than those mentioned in sub-rule (1) prior approval of the arrangements made for the disposal of trade-wastes and, effluents shall be obtained from the Health Officer. Rule 22-A Prescribed under sub-section (2) of section 13 3[22-A. Ventilation and temperature.-(1) Limits of temperature and air movement.- In any factory the maximum wet-bulb temperature of air in a work- room at a height of 1.5 metres above the floor level shall not exceed 30oC and adequate air movement of at least 30 meters per minute shall be provided; and in relation to dry-bulb temperature, the wet-bulb temperature in the work-room at the said height shall not exceed more than that shown in the Schedule hereto, or as regards a dry-bulb reading intermediate between the two dry-bulb readings, that specified in relation to the highter of these two dry bulb readings: SCHEDULE Dry bulb temperature Wet Bulb temperature 30oC to 34oC 29oC 35oC to 39oC 28.5oC 40oC to 44oC 28oC 45oC to 47oC 27.5oC Provided that if the temperature measured with a thermometer inserted in a hollow globe of 15 centimeters diameter coated mat black outside and kept in the environment for not less than 20 minutes, exceeds the dry-bulb temperature of air, the temperature so recorded by the globe thermometer shall be taken in place of the dry-bulb temperature: Provided further that when the reading of the wet-bulb temperature outside in the shade exceeds 27oC, the value of the wet-bulb temperature allowed in the 1 Ins. and renumbered by G.N. dt. 8.2.1988 2 Renumbered by G.N. dt. 8.2.1988 3 Added by G.N. of 15.10.1984 The Maharashtra Factories Rules, 1963 101 schedule for a given dry-bulb temperature may be correspondingly exceeded to the same extent: Provided further that this requirement shall not apply in respect of factories covered by section 15 of the Act and in respect of factories where the nature of work carried on involves production of excessively high temperature referred to in clause (ii) of sub-section (i) of section 13 to which workers are exposed for short periods of time not exceeding one hour followed by an interval of sufficient dura- tion in thermal environments not exceeding those otherwise laid down in the rule: Provided also that the Chief Inspector, having due regards to the health of the workers, may in special and exceptional circumstances, by an order in writing exempt any factory or part of a factory from the foregoing requirements; subject to such conditions as he may specify. (2) Provision of thermometers.-(a) If it appears to the Inspector that in any factory, the temperature of air in a work-room is sufficiently high and is likely to exceed the limits prescribed in sub-rule (1), he may serve on the factory manager an order in writing requiring him to provide sufficient number of whirling hygrometers or any other type of hygrometers and direct that the dry-bulb and wet-bulb reading in each such work-room shall be recorded at such positions and at such intervals, as approved by the Inspector, by a person specially nominated for the purpose by the manager and approved by the Inspector. (b) If the Inspector has reason to believe that a substantial amount of heat is added inside the environment of a work-room by radiation from walls, roof or other surroundings, he may serve on the factory manager an order requiring him to provide one or more globe thermometers referred to in the first proviso in sub- rule (1) and further requiring him to place the globe thermometers at places specified by him and keep a record of the temperature in a register showing the spots, the timings and the temperature observed. (3)(a) In every factory the number of ventilation openings in the work-room below the caves shall, except where mechanical means of ventilation as required by sub-clause (b) below are provided be of an aggregate area of not less than 15 per cent of the floor area and so located as to afford a continued supply of fresh air: Provided that out of this total ventilation area, ventilation opening equivalent to at least 10 per cent of the floor area shall, be located at not more than one meter sill level height from the floor level: Provided further that the Chief Inspector may relax the requirements regarding the amount of ventilation openings if he is satisfied that having regard to the location of the factory, orientation of the work-room, prevailing winds, roof height and nature of manufacturing process carried on, sufficient supply of fresh air into the work-room is afforded during most of the working time: Provided also that this requirement shall not apply in respect of work-rooms of factories which are covered by section 15 of the Act, or in which temperature and humidity are controlled by refrigeration or air-conditioning or both. (b) Where in any factory due to special circumstances such as situation with respect to adjacent building or internal obstructions like partitions etc. the height of the building or floor space, the requirements of ventilation openings under clause(a) cannot be complied with for any work-room or where the span of work- room, having necessary ventilation openings exceeds 18 metres or where any 102 The Maharashtra Factories Rules, 1963 work place is at a distance exceeding 9 metres from a ventilation opening at working level or in the opinion of the Inspector the temperature of air in a work- room is sufficiently high and is likely to exceed the limits prescribed in sub-rule (1), additional ventilation by mechanical means shall be provided. (c) The amount of fresh air supplied by mechanical means of ventilation in an hour shall be equivalent to at least six times the cubic capacity of the work-room and shall be distributed evenly throughout the work-room without dead air-pockets or undue draughts caused by high inlet velocities. (d) In regions where in summer (15th March-15th July) dry bulb temperatures of outside air in the shade during most part of the day exceed 35oC and simultaneous wet bulb temperature are 25oC or below and in the opinion of the Inspector the manufacturing process carried on in the work-room of factory permits thermal environments with relative humidity of 5 per cent or more, the Inspector may serve on the factory manager an order to have sufficient supply of outside air for ventilation cooled by passing it through water sprays either by means of unit type of evaporative air coolers (desert coolers) or, where supply of outside air is provided by mechanical means through ducts in a plenum system, by means of central air washing plants.] Rules 23 to 33 prescribed under sub-section (1) of section 15

Previous and next

All provisions of The Maharashtra Factories Rules, 1963

Questions people ask

Is rule 22 of the Maharashtra Factories Rules, 1963 still in force?

No repeal of the Maharashtra Factories Rules, 1963 is recorded.