LawGrids logoLAWGRIDS.ORG

Rule 23, The Factory rules 1962: Ventilation and temperature

The Factory rules 1962 - Rule 23

Text of rule 23

Ventilation and temperature

[23. Ventilation and temperature. - (1) Limits of temperature and air movement. - In any factory the maximum wet-bulb temperature of air in a work room at a height of 1.5 meters above the floor level shall not exceed 30 degrees Celsius and adequate air movement of at least 30 meters per minute shall be provided and in relation to dry-bulb temperature, the wet-bulb temperature in the work-room at the said height shall not exceed that shown in the schedule annexed hereto, or as regards a dry-bulb reading intermediate between the two dry-bulb readings that specified in relation to the higher of these two dry-bulb readings : Schedule Dry-bulb temperature Wet-bulb temperature 30°C to 34°C 29°C 35°C to 39°C 28.5°C 40°C to 44°C 28°C 45°C to 47°C 27.5°C : Provided that if the temperature measured with a thermometer inserted in a hollow globe of 15 centimeter coated met black outside and kept in the environment for not less than 20 minutes exceeds the dry-bulb temperature of air, the temperature so recorded by the globe thermometer shall be taken in place of the dry-bulb temperature : Provided further that when the reading of the wet-bulb temperature outside in the shade exceeds 27 degree celsius, the value of the wet-bulb temperature allowed in the schedule for a given dry-bulb temperature may be correspondingly exceeded to the same extent : Provided further that this requirement shall not apply in respect of factories covered by Section 15 and in respect of factories where the nature of work carried-on involves production of excessively high temperatures referred to in clause (ii) of sub-section (1) to which workers are exposed for short periods of time not exceeding one hour followed by an interval of sufficient duration in thermal environments not exceeding those otherwise laid down in this rule : Provided further that the Chief Inspector, having due regard to the health of the workers, may in special and exceptional circumstances, by an order in writing exempt any factory or part of a factory from the foregoing requirement, in so far as restricting the thermal conditions within the limits laid down in the schedule are concerned, to the extent that he may consider necessary subject to such conditions as he may specify. (2) Provision of thermometers. - (a) If it appears to the Inspector that in any factory, the temperature of air in a work room is sufficiently high and is likely to exceed the limits prescribed is sub-rule (1), he may serve on the manager of the factory an order requiring him to provide sufficient number of whirling hygrometers or any other type of hygrometers and direct that the dry-bulb and wet-bulb reading in each such workroom shall be recorded at such positions as approved by the Inspector twice during each working shift by a person especially nominated for the purpose by the manager and approved by the Inspector. (b) If the Inspector has reason to believe that a substantial amount of heat is added inside environment of a workroom by radiation from walls, roof or other solid surroundings, he may serve on the manager of the factory an order requiring him to place the globe thermometers referred to in the first proviso in sub-rule (1) at place specified by him and keep a record of the temperature in a suitable register. (3) Ventilation. - (a) In every factory the amount of ventilating openings in a workroom below the caves shall, except where mechanical means of ventilation as required by clause (b) below are provided, be of an aggregate area of not less than 15% of the floor area and so located as to afford a continued supply of fresh air : Provided that the Chief Inspector may relax the requirements regarding the amount of ventilating openings if he is satisfied that having regard to the location of the factory orientation of the workroom, prevailing winds, roof height and the nature of manufacturing process carried on, sufficient supply of fresh air into the workroom is afforded during most part of the working time : Provided further that this requirement shall not apply in respect of workrooms of factories- (i) covered by Section 15; or (ii) in which temperature and humidity are controlled by refrigeration, and air conditioning. (b) Where in any factory owing to special circumstances such situation with respect to adjacent buildings and height of the building with respect to floor space, the requirements of ventilation openings under clause (a) of this sub-rule he may serve on the manager of the factory an order requiring him to provide additional ventilation either by means of roof ventilators or by mechanical means. (c) The amount of fresh air supplied by mechanical means of ventilation in an hour shall be equivalent to at least six times the cubic capacity of the workroom and shall be distributed evenly throughout the workroom without dead air pockets or undue draughts cansed by high inlet velocities. (d) In regions where in summer (15th March, 15th July) dry-bulb temperature of outside air in the shade during most part of the day exceed 35 degrees Celsius and simultaneous wet-bulb temperatures are 25 degrees celsius or below and in the opinion of the Inspector the manufacturing process carried on the workroom of a factory permits thermal environments with relative humidity of 50% or more, the Inspector may serve on the manager of the factory an order to have sufficient supply of outside air for ventilation cooled by passing it through water sprays either by means of unit type of evaporative air coolers (desert coolers) or, where supply of outside air is provided by mechanical means through ducts in a plenum system, by means of central air washing plants.] Rules 24 to 34 prescribed under sub-section (1) of Section 15

Previous and next

All provisions of The Factory rules 1962

Questions people ask

Is rule 23 of the Factory rules 1962 still in force?

No repeal of the Factory rules 1962 is recorded.