Rule 26, The Rajasthan Boilers Rules,1954: External inspection
The Rajasthan Boilers Rules,1954 - Rule 26
Text of rule 26
External inspection
26. External inspection. - Boilers must be examined externally as well as
internally; particular attention should be paid to the external parts of the
boilers where in contact with seating blocks and brick work, especially when
the situation is damp. Having regard to many serious defects discovered,
inspector should take care, in order to ensure proper inspection, that boilers,
of which the whole of the outside cannot be readily examined, are cleared
whenever they consider it necessary of any concealing covering, supports or
fittings.
Saddle tanks and engine fittings of locomotive type boilers should be
removed for inspection of the parts underneath at the first inspection and at
any reasonable period afterwards if the inspector cannot satisfy himself. If the
owners in any special case have any good reasons for not wishing to clear
covered parts the case should be submitted to the Chief Inspector for orders
The inspector must keep in mind that he is not to certify as efficient any boiler
regarding the condition of which he cannot thoroughly satisfy himself.