1[70:Floor. - (i) All floors laid on ground shall be so constructed or treated
as to prevent damp rising by capillary action into the floor. In all cases oflayer or
10 Crus. of clear sand shall be provided between the earth and tho hard crust.
(ii) Every kitchen, latrine, urinal, bathroom or a bathing platform, shall have
impermeable floor and all kitchens, in addition to impermeable, shall have fire
prooffloors. . , ' .
(W) TIH~ walls of every wafer,closet upto a height of not less than sixty
centimetres (60 Cms.c) above jho floors shal! be finished in an' impervious mate-
rial.] " . . . _ . . - . .
1(71. Roofs. - The roof of a building shall be so constructed as to be fire
resisting, weather proofand non-crodable.]
"' ......
. 1[72. Staircase ill residential bllildilzgs, sillglefamily or Iwofamily rest
dential bllill/illes. - Every building more than one storey high intended to be used
as residential building shall be provided with atleast one staircase having minimum
width of 85 ems. with rise of not more than 19 crns., limited to 15 Nos. per flight
and tread not less than 25 ems. in width constructed of tire resisting rnaterials.]
***
1(73. Residential buildings for more than two families, - Every building
intended to be used as residential building for more than two families shall be
provided with atleast one staircase extending from ground floor level to the high
est floor having minimum clear width in accordance with the following width in
accordance with the following table :-
" (a) Number of users upto 10 85 ems.
(b) Number of users upto II to 20 .1.10 meters
(c) Number of users from 21 to 100 1.25 meters
(d) Increase 1fI (2.5 cms.) for every additional 15 persons until a maximum
of2.75 in. is reached.
'Asingle staircase ofwidth mentioned above may be replaced by two stair
case each ofawidth atleast equal to two-thirds the width prescribed for a single
staircase provided neitherofother two substituted staircases be less than 1.1 m
in width. Staircase so provided shall be built in fire resisting materials.
(0) Occupant Load:
---------_.----.._--- - ----------~--------------_._------- ---------------
: . S.:" pt;. ::::"pilaJ (Dev. & Reg.) (}uilL;llii ~'\lncnd;;lJllt) Rules, ! 993 (22-1-:993)
, .
62 Punjab Capital (Development and Regulation) Building Rules, 1952
Previous and next
All provisions of Punjab Capital(Development and Regulation)Building Rules,1952
Questions people ask
Is rule 61 of Punjab Capital(Development and Regulation)Building Rules,1952 still in force?
No repeal of Punjab Capital(Development and Regulation)Building Rules,1952 is recorded.