LawGrids logoLAWGRIDS.ORG

Rule 39, Punjab Capital(Development and Regulation)Building Rules,1952: Site

Punjab Capital(Development and Regulation)Building Rules,1952 - Rule 39

Text of rule 39

Site

39. Site. - No person shall. erect or re-erect any building on any ground which has been filled up with offal or offens ive vegetable or animal mailer or upon which any such matter is deposited, unless and until tho Medical Officer of Health certifies that such matter has been properly removed by excavation or otherwise has become or been .rcndered innocuous. '[40. Structural Design. - The structural design of foundation masonary timber plan concrete, reinforced concrete, pre-stretched concrete and structural steel, shall be carried out in accordance with part VI Struotural Design, Section I - Loads Section-2 - Foundation, Scction-J - Wood, Section-4 - Masonary Sectjon-5-Concrete, Section-6-'Steel oflhe National Building Code of'India, laking into consideration all relevant Indian Standrds prescribed by the Bureau of Indian Standards including the Indian Standards given in Annexure 'A' for earth­ quake protection OfbUildi~.] '[41. to 49. Deleted. '[SO. Thickness of alis. - All structural.external and partywalls exposed to weather/protected from weather built ofbrieks ofblocks laid illhorzontal bed.. or courses shall be constructed of thickness 1I0t less than 28 ems. upto three storied buildings with maximum height not more thun 10.5 meter. The thlekness of . .- --------_ .- .- ---------- - --- I. Sec PI!.capital(Dev, & Rell.) tluir,t;"g (Amendment) Rules, 1993 (22.:.,1993) 2. Sub>. "ide eM. Admn, 0117_ No,lncallon No. ~1JI10!63-UTFt(j)-2001/4011 Ill. 16-5-2DOt p. 1027 punjab Capital (Development and Regulation) Building Ru les, 1952, (I) Only oiie servant 100m shall be: built on a site:of'size 420 sq. rnts. or more , . ' in area. (ii) For one dwelling unit, only one servant room shall be provided. (Iii) If a servant room is built 011 II ground fluor i1 shall have a separate courtyard of not less than 10 sq. mts, (Iv) Separate servant room not built as part of the main house shall have a wate r closet and bathroom attached thereto. (v) 1111~ maximum covered area of a servant room shall not exceed 12 sq. mts. excluding water closet and bathroom.] . '[33. Advertisement stand ami structure; - No structure shall be CO Il­ structed to carry all advertisement except in the area shown on the zon ing plan! architectural control sheet/standard design.] , 34. Numbering ofbuildings» Each building shall bear a number in aCCOr­ dance with the type designs which shall be: made available by the ChiefAd min is­ trator and shall bear IIU other number; I [35. Dust Bin. - Every person who creels or re-erects a bui lding, shall provide a dustbin which shall conform in size, shape, specifications and to a type ofdesign to be made available by the ChiefAdminlstrator.l . PARTlY Material and Struetul'lIl C\lnlrul Section 1 . • Materials '[,56.All material to be used for the erection or re-erectlon of'a building shall conform to the specification and-standard laid down In part V of the Nat ional BuiJdingCode oflndiaon Building Material.] '[37. LJeleted.] ,' [311. Deleted.] ,, 60 Punjab Capital (Development and Regulation) Building Rules, 1952 walls shall be determined in accordance with the relevant provisions ofNational Building Code of India, incase buildings with height more tan to.5 M.] I [51. to 59 Deleted.] '[60. Applicatlon: (i) Chimneys where provided shall conform to the re- ' quircments of IS 1645 - 1960 Indian Standard Code of Practice for Fire Safety of Iluild ing (General) Chimney's flues, Flue pipes and Hearths. (ii) Notwithstanding the provisions lor clause (i) above a chimney shaft shall be built 1.8 M high above the roof ill the case or approachable terraces used for sleeping purposes and within the heights ofthe parapet-in other cases. In the case , ofs!oping roofs, the chimney shaft shall not be less than 0,6 M above the ridge of -. the roof in which it penetrates. ' . (iii) Chimney shafts shell be provided with a set back of0.9 M from the front and rear of the building in all cases and also from the external side in the case of corner plots.]

Previous and next

All provisions of Punjab Capital(Development and Regulation)Building Rules,1952

Questions people ask

Is rule 39 of Punjab Capital(Development and Regulation)Building Rules,1952 still in force?

No repeal of Punjab Capital(Development and Regulation)Building Rules,1952 is recorded.