Rule 65, Rajasthan Factories Rules,1951: Ladders
Rajasthan Factories Rules,1951 - Rule 65
Text of rule 65
Ladders
65. Ladders. — All ladders used in replacing belts shall be specially made and reserved for
that work and provided with hooks or an effective non-skid device.
Ladder provided with hooks must have hooks fitted in such suitable position that they rest
on the shaft when the bottom end of the ladder is resign on the floor.
@[65A. Protection of workers attending to prime movers. — (1) In every factory the
work of oiling or attending to prime movers shall be done only by a specially trained adult
male worker authorised to do such work whose name has been recorded in the register
maintained in Form 8.
(2) Every such worker while oiling or attending to a prime mover shall wear tight fitting
clothing.
(3) A worker required to wear tight fitting clothing under sub- rule (2) shall be provided by
the occupier with clothing which shall consist of at least a pair of closely fitting shirts and a
closely fitting half sleeve shirt or vest. Such clothing shall be returned to the occupier on
termination of service or when new clothing is provided.]
#[65AA. Ovens and Dryers:— (1) Application.— This rule shall apply to ovens and
dryers, except those used in laboratories or kitchens of any establishment and those which
have a capacity below 325 litters.
(2) Definition.— For the purpose of this Rule, oven or drier means any enclosed structure,
receptacle, compartment or box which is used for baking, drying or otherwise processing of
any article or substance at a temperature higher than the ambient temperature of the air in
the room or space in which the oven or drier is situated, and in which a flammable or
explosive mixture of air and a flammable substance is likely to be evolved within the
enclosed structure, receptacle, compartment or box or part thereof on account of the article
or substance which is baked, dried or otherwise processed within it.
-----------------------------------------------------------------------------------------------------------------------
@. Added vide Notification No. F. 2(58)/L&E/64. dated 25.3.1968; Rajasthan Gazette Part
IV(Ga dated 11.7.68.
#. Deleted vide Notification No. F.4(3) Shram/88 dated 8.1.1991, published in Rajasthan
Gazette Part 3(Ga) dated Rajasthan 25.6.1992
(3) Separate electrical connection.— Electrical power supplied to every oven or drier shall
be by means of a separate circuit provided with an isolation switch.
(4) Design, Construction, examination and testing.— (a) Every oven or drier shall be
properly designed on sound engineering practiced and be of good construction, sound
material and adequate strength, free from any patent defects and safe if properly used.
(b) No oven or drier shall be taken into use in a factory for the first time unless a
competent person has thoroughly examined all its parts and carried out the tests as
are required to establish that the necessary safe systems and controls provided for
safety in operation for the processes for which it is to be used and a certificate of
such examination and tests signed by that competent person has been obtained and
is kept available for inspection.
(c) All parts of an oven or drier which has undergone any alteration or repair which has
the effect of modifying any of the design characteristics, shall not be used unless a
thorough examination and test as have been mentioned in clause (b) has been
carried out by a competent person and a certificate of such examination and tests
signed by that competent person has been obtained and is kept available for
inspection.
(5) Safety Ventilation.— (a) Every oven or drier shall be provided with a positive and
effective safety ventilation system using one or more motor-driven centrifugal fan so as to
dilute any mixture of air and any flammable substance that may be formed within the oven
or drier and maintain the concentration of the flammable substance in the air at a safe level
of dilution.
(b) The safe level of dilution referred to in clause (a) shall be so as to achieve a
concentration of the concerned flammable substance in air of not more than 25 percent of
its lower explosive limit:
Provided that a level of concentration in air up to 50 percent of the lower explosive
limit of the concern flammable substance may be permitted to exist subject to installation
and maintenance of an automatic device which :
(i) shows continuously the concentration of the flammable substances in air present in
the oven or drier at any instant;
(ii) sounds an alarm when the concentration of the flammable substance in air in any
part of the oven or drier reaches a level of 50 percent of its lower explosive limit: and
(iii) shuts down the heating system of the oven or drier automatically when the
concentration in air of the flammable substance in any part of the oven or drier
reaches a level of 60 percent of its lower explosive limit, is provided to the oven or
drier and maintained in efficient working condition.
(c) No over or drier shall be operated without its safety ventilation system working in an
efficient manner.
(d) No oven or drier shall be operated with a level of dilution less than what is referred to in
clause (b).
(e) Exhaust ducts of safety ventilation systems should be so designed and place that their
ducts discharge the mixture of air and flammable substance away from the work-rooms and
not near windows or doors or other openings from where the mixture could re-enter the
work-rooms.
(f) The fresh air admitted into the oven or drier by means of the safety ventilation system
shall be circulated adequately by means of circulating fan or fans through all parts of the
oven or drier so as to ensure that there are no locations where the flammable substance
can accumulate in the air or become pocketed to any dangerous degree.
(g) Throttling dampers in any safety ventilation system should be so designed by cutting
away a portion of the damper or otherwise, that the system will handle at least the minimum
ventilation rate required for safety when they are set in their maximum throttling position.
(6) Explosion Panels.— (a) Every oven or drier having an internal total space of not less
than half cubic metres shall be provided with suitably designed explosion panels so as to
allow release of the pressure of any possible explosion within the oven or drier through
explosion vents. The area of openings to be provided by means of such vents together with
the area of openings of any access doors, which are provided with suitable arrangements
for their release in case of an explosion, shall be not less than 2200 square centimeters for
every one cubic meter of volume of the oven or drier: The design of the explosion panels
and doors as above said shall be such as to secure their complete release under an internal
pressure of 0.25 kg. per square centimeter.
(b) The explosion releasing panels, shall, as far as practicable, be situated at the roof of the
oven or drier or at those portions of the walls where persons do not remain in connection
with operation of the oven or drier.
(7) Interlocking arrangements.— (a) In each oven or drier efficient interlocking
arrangements shall be provided and maintained to ensure that—
(1) all ventilating fans and circulating fans whose failures would adversely effect the
ventilation rate of flow pattern, are in operation before any mechanical conveyor that
may be provided for feeding the articles or substances to be processed in the oven or
drier is put into operation:
(ii) failure of any of the ventilating or circulating fans will automatically stop any conveyor
as referred to in clause (i) as may be provided, as well as stop the fuel supply by
closing the shut off valve and shut off the ignition in the case of gas or oil fired ovens,
and in the case of electrically heated ovens switch off the electrical supply to the
heaters;
(iii) the 'above said mechanical conveyor is set in operation before the above said shut
off valve can be energized: and
(iv) the failure of the above said conveyor will automatically close the above said shut off
valve in the case of ovens and dryers heated by gas, oil or steam and deactivate the
ignition system, or cut off the electrical heaters in the case of electrically heated
ovens or furnaces:
(8) Automatic preventilation.— Every oven or drier heated by oil, gas, steam or electricity
shall be provided with an efficient arrangement for automatic preventilation consisting of at
least 3 volume changes with fresh air by operation of the safety ventilation fans and the
circulating fans (if used) so as to effect purging of the oven or drier of any mixture of air and
a flammable substance before the heating system can be activated and before the conveyor
can be placed in position.
(9) Temperature Control.— Every oven or drier shall be provided with an automatic
arrangement to ensure that the temperature within does not exceed a safe upper present
limit to be decided in respect of the particular processing being carried on.
(10) Multistage Processes.— Wherever materials are to be processed in ovens or dryers
in successive operations, suitable arrangement should be provided to ensure that the
operating temperatures necessary for safe operation at each stage are maintained within
the design limits.
(11) Combustible substances not to drip on electrical heaters or burners flame.—
Effective arrangements shall be provided in every oven or drier to prevent dripping of
combustible substances on electric heaters or burner flame used for heating.
(12) Periodical Examination, Testing and Maintenance.- (a) All parts of every oven and drier
shall be properly maintained and thoroughly examined and the various controls as
mentioned in this rule and the working of the oven or drier tested at frequent intervals to
ensure its safe operation by a responsible person designated by the occupier or manager or
who by his experience and knowledge of necessary precautions against risks of explosion,
is fit to undertake such work.
(b) A register shall be maintained in which the details of the various tests carried out
from time to time under clause (a) shall be entered and every entry made shall be
signed by the person making the tests.
(13) Training of Operators.— No person shall be assigned any task connected with
operation of any oven or drier unless he has completed 18 years of age and he is properly
trained in the manner as prescribed by the Chief Inspector.
(14) Polymerising Machines.— (a) Printed fabric shall be thoroughly dried by passing
them over drying cans or through hot flue or other equally effective means, before the same
is allowed to pass through polymerising machines.
(b) Infrared ray heaters of polymerising machines shall be cut off while running the
prints."]
@[65B. Provision of crawling boards etc., on fragile roofs. — In any factory, no person
shall be required to stand or pass over or work on or near any roof or ceiling covered with
fragile material through which he is liable to fall, in case it breaks or gives, way, a distance
of more than three metres unless—
(a) suitable and sufficient ladders, such ladders or crawling boards, which shall be
securely supported are provided and used, and
(b) a permit to work on the fragile roof is issued to him each time he is required to work
thereon by a responsible person of the factory concerned.]
#[65C. Safety Belts. — Where any person is required or allowed to work at a place from
where he may fall from a distance of more than ten feet, he shall be provided with a safety
belt with leater shoulder straps of not less than two inches in width and a 'D' ring at the back
for fastening a rope, the other end of which shall be securely tied or hooked to some
suitable rigid fixture. The safety belt so provided shall be tested and examined thoroughly
by a competent person at least once in six months and a certificate with regard to its
suitability shall be obtained from the said competent person and entered in a register, which
shall be produced before the Inspector on demand.]
Previous and next
Questions people ask
Is rule 65 of Rajasthan Factories Rules,1951 still in force?
No repeal of Rajasthan Factories Rules,1951 is recorded.