Rule 62, Rajasthan Factories Rules,1951: Exemptions
Rajasthan Factories Rules,1951 - Rule 62
Text of rule 62
Exemptions
62. Exemptions. — The requirements of sub-section (4) of section 37 shall not apply to the
following processes, carried on in any factory:
(a) The operation of repairing a water sealed gas holder by the electric welding process,
subject to the following conditions:—
(i) The gasholder shall contain only the following gases separately or mixed at a
pressure greater than atmospheric pressure, namely town gas, coke-oven gas,
producer gas, blast furnace gas, or gases, other than air, used in their manufacture:
Provided that this exemption shall not apply to any gasholder containing acetylene
or mixture of gases to which acetylene has been added intentionally;
(ii) Welding shall only be done by the electric welding process and shall be carried out
by experienced operatives under the constant supervision of a competent person.
(b) The operations of cutting or welding steel or wrought iron gas mains and services by the
application of heat, subject to the following conditions : —
(i) The main or service shall be situated in the open air and it shall contain only the
following gases, separately or mixed at a pressure greater than atmospheric
pressure, namely, gas, coke- oven gas, producer gas, blast furnace gas, or gases
other than air, used in their manufacture;
(ii) The main or service shall not contain acetylene or any gas or mixture of gases to
which acetylene has been added intentionally;
---------------------------------------------------------------------------------------------------------------------
#. Substituted vide Notification No. F. 1(2)/8/Lab/68. dated 6.8.74; published in Rajasthan
Gazette Part IV-Ga(1). Extraordinary, dated 9.8.74.
@. Substituted vide Notification No. F1(112)L&E/76 dated 24.3.1979; Rajasthan Gazette
Part IV-Ga(1). dated 26.4.1979
(iii) The operation shall be carried out by an experienced person or persons and at least
2 persons (including those carrying out the operations) experienced in work on gas
mains and over 18 years of age shall be present during the operation;
(iv) The site of the operation shall be free from any inflammable or explosive gas or
vapour;
(v) Where acetylene gas is used as a source of heat in connection with an operation, it
shall be compressed and contained in a porous substance in cylinder; and
(vi) Prior to the application of any flame to the gas main or service, this shall be pierced
or drilled and the escaping gas ignited.
(c) The operation of repairing an oil tank on any ship by the electric welding process shall
be subject to the following conditions:—
(i) The only oil contained in the tank shall have a flash point of not less than 150 degree
F. (close test) and a certificate to this effect shall be obtained from a competent
analyst;
(ii) The analyst's certificate shall be kept available for inspection by an Inspector, or by
any person employed or working on the ship;
(iii) The welding operation shall be carried out only on the exterior surface of the tank at
a place (a) which is free from oil or oil leakage in inflammable quantities and (b) which
is not less than one foot below the nearest part of the surface of the oil within the
tank; and
(iv) Welding shall be done only by the electric welding and shall be carded out be
experienced operatives under the constant supervision of a competent person.
Rule prescribed under sub-section (1) of section 38
@[63. Fire.- (1) Processes, equipment, plant etc. involving serious explosion and serious
fire hazards.- (a) All processes involving serious explosion and flash fire hazard shall be
located in segregated building where the equipment shall be so arranged that only a
minimum number of employees are exposed to such hazards at any one time.
(b) All industrial processes involving serious fire hazard should be located in building or
work places separated from one another by walls of fire-resistant construction.
(c) Equipment and plant involving serious fire or flash fire hazard shall, wherever possible,
be so constructed and installed that in case of fire, they can be easily isolated.
(d) Ventilation ducts, pneumatic conveners and similar equipment involving serious fire risk
shall be provided with flame arresting or automatic fire extinguishing appliances.
(e) In all work places having serious fire or flash fire hazards. passages, between machine.
installation or piles of material should be at least 90 cm. wide.
(2) Access for firefighting.— Buildings and Plants shall be so laid out and roads,
passageways etc. so maintained as to permit unobstructed access for fire fighting.
(3) Protection against lighting.— Protection from lighting shall be provided for
(i) building in which explosive or highly flammable substances are manufactured, used,
handled or stored;
--------------------------------------------------------------------------------------------------------------
@. Deleted vide Notification No. F.4(3) Shram/88 dated 8.1.1991, published in
Rajasthan Gazette Part 3(Ga) dated Rajasthan 25.6.1992
(ii) Storage tanks containing oils, paints, or other flammable liquids;
(iii) Gram elevators; and
(iv) Building. tall chimneys or stacks where flammable gases, fumes, dust or lint are
likely to be present.
(4) Explosives.— All explosives shall be handled, transported, stored and used in
accordance with the provisions in the Indian Explosives Act, 1984.
(5) Precautions against ignition.— Wherever there is danger of fire or explosion from
accumulation of flammable or explosive substances in air:-
(a) all electrical apparatus shall either be excluded from the area of risk or they shall be
of such construction and so installed and maintained as to prevent the danger of their
being a source of ignition;
(b) effective measures shall be adopted for prevention of accumulation of static charges
to a dangerous extent;
(c) Workers shall wear shoes without iron or steel nail or any other exposed ferrous
material which is likely to cause sparks by friction;
(d) Smoking, lighting or carrying of matches, lighters or smoking material shall be
prohibited;
(e) transmission belts with iron fasteners shall not be used and
(f) all other precautions, as are reasonably practicable, shall be taken to prevent
initiation of ignition from all other possible sources such as open flames, frictional
sparks, overheated surfaces of machinery or plant, chemical or physical chemical
reaction and radiant heat.
(6) Spontaneous ignition.— Where materials are likely to induce spontaneous ignition,
care shall be taken to avoid formation of air pocket and to ensure adequate ventilation.
(7) Cylinders containing compressed gas.— Cylinders containing compressed gas may
only be stored in open if they are protected against excessive variation of temperature,
direct rays of sun, or continuous dampness. Such cylinders shall never be stored near
highly flammable substances, furnaces or hot processes. The room where such cylinders
are stored shall have adequate ventilation.
(8) Storage of flammable liquids.— (a) The quantity of flammable liquids in any work
room shall be the minimum required for the process or processes carried on in such room.
Flammable liquids shall be stored in suitable containers with close fitting covers:
Provided that not more than 20 liters of flammable liquids having a flash point of 21°C or
less shall be kept or stored in any work room.
(b) Flammable liquids shall be stored in closed containers and in limited quantities in
well ventilated rooms of fire resisting construction which are Isolated from the
remaining of the building by fire walls and self closing fire doors.
(c) Large quantities of such liquids shall be stored in isolated adequately ventilated
building of fire resisting construction or in storage tanks, preferably underground and
at a distance from any building as required in the petroleum Rules, 1976.
(d) Effective steps shall be taken to prevent leakage of such liquids into basements,
sumps or drains and to confine any escaping liquid within safe limits.
(9) Accumulation of flammable dust, gas, fume or vapour in air or flammable waste
material on the floors.— (a) Effective steps shall be taken for removal or prevention of the
accumulation in the air of flammable dusts, gas, fume or vapour to an extent which is likely
to be dangerous.
(b) No waste material of flammable nature shall be permitted to accumulate on the
floors and shall be removed at least once in a day or shift, and more often, when
possible: such materials shall be placed in suitable metal containers with covers
wherever possible.
(10) Fire exits— (a) In this rule, —
(i) "horizontal exit" means an arrangement which allows alter-native egress from a
floor area to another floor at or near the same level in an adjoining building or
an adjoining part of the same building with adequate separation; and
(ii) "travel distance" means the distance an occupant has to travel to reach an exit.
(b) An exit may be a doorway. corridor, passageway to an internal or external stairway
or to a verandah. An exit may also include a horizontal exit leading to an adjoining
building at the same level.
(c) Lifts, escalators and revolving doors shall not be considered as exits for the purpose
of this sub-rule.
(d) In every room of a factory sufficient exits to permit safe escape of the occupants in
case of fire or other emergency shall be provided which shall be free of any
obstruction.
(e) The exits shall be clearly visible and suitably illuminated with suitable arrangement,
whatever artificial lighting is to be adopted for this purpose, to maintain the required
illumination in case of failure of the normal source of electric supply.
(f) The exits shall be marked in a language understood by the majority of the workers.
(g) Fire resisting doors or roller shutters shall be provided at appropriate places along
the escape routes to prevent spread of fire and smoke, particularly at the entrance of
lifts or stairs where funnel or flue effect may be created inducing an upward spread of
fire.
(h) All exits shall provide continuous means of egress to the exterior of a building or to
an exterior open space leading to a street.
(i) Exits shall be so located that the travel distance on the floor shall not exceed 30
meters.
(j) In case of those factories where highly hazardous materials are stored or used, the
travel distance to the exit shall not exceed 22.5 meters and there shall be at least two
ways of escape from every room, however small, except toilet rooms, so located that
the points of access thereto are out of or suitably shielded from areas of high hazard.
(k) Wherever fore than one exit is required for any room space or floor, exits shall be
placed as remote from each other as possible and shall be arranged to provide direct
access in separate directions from any point in the area served.
(l) The unit of exit width used to measure capacity of any exit shall be 50 cm. A clear
width of 25 cm, shall be counted as an additional half unit. Clear width of less than 25
cm. shall not be counted for exit width.
(m) Occupants per unit width shall be 50 for stairs and 75 for doors.
(n) For determining the exits required, the occupant load shall be reckoned on the basis
of actual number of occupants within any floor area or 10 square metres per person,
whichever is more.
(o) There shall not be less than two exits serving every floor area above and below the
ground floor, and at least one of them shall be an internal enclosed stairway.
(p) For every building or structure used for storage only, and every section thereof
considered separately, shall have access to at least one escape so arranged and
located as to provide a suitable means of escape for any person employed therein
and in any such room wherein more than 10 persons at least two separate means of
exits shall be available as remote from each other as practicable.
(q) Every storage area shall have access to at least one means of exit which can be
readily opened.
(r) Every exit doorway shall open into an enclosed stairway, a horizontal exit on a
corridor or passageway providing continuous and protected means of egress.
(s) No exit doorway shall be less than 100 cm. in width, doorway shall be not less than
200 cm. in height.
(t) Exit doorways shall open outwards, that is, away from the room but shall not obstruct
the travel along any exit. No door when opened shall reduce the required width of
stairway or landing, to less than 90 cm. over head or sliding doors shall not be
installed for this purpose.
(u) An exit door shall not open immediately upon a flight of stairs. A landing equal to at
least the width of the doorway shall be provided in the stairway at each doorway. The
level of landing shall be the same as that of the floor which it serves.
(v) The exit doorways shall be open able from the side which they serve without the use
of a key.
(w) Exit corridors and passageways shall be of a width not less than the aggregate
required with of exit doorways leading from therein the direction of travel to the
exterior.
(x) Where stairways discharge through corridors and passageways, the height of the
corridors and passageways shall not be less than 240
(y) Internal stairs shall be constructed of non-combustible material throughout.
(z) Internal stairs shall be constructed as a self contained unit with at least one side
adjacent to an external wall and shall be completely enclosed.
(aa) A staircase shall not be arranged round a lift shaft unless the latter is totally
enclosed by a material having a fire resistance rating not lower than that the type of
construction of the former.
(bb) Hollow combustible construction shall not be permitted.
(cc) The minimum width of an internal staircase shall be 100 cm.
(dd) The minimum width of treads without nosing shall be 25 cm. for internal staircase.
The treads shall be constructed and maintained in a manner to prevent slipping.
(ee) The maximum height of a riser shall be 19 cm. and the number or risers shall be
limited to 12 per flight.
(ff) Hand rails shall be provided with a minimum height of 100 cm. and shall be firmly
supported.
(gg) The use of spiral staircase shall be limited to low occupant load and to a building of
height of 9 metres, unless they are connected to platforms such as balconies and
terraces to allow escapes to pause. A spiral staircase shall be not less than 300 cm.
in diameter and have adequate head room.
(hh) The width of a horizontal exit shall be same as for the exit doorways.
(ii) The horizontal exit shall be equipped with at least one fire door of self closing type.
(jj) The floor area on the opposite or refuge side of a horizontal exit shall be sufficient to
accommodate occupants of the floor areas served, allowing not less than 0.3 square
meter per person. The refuge area shall be provided with exit adequate to meet the
requirements of this sub-rule. At least one of the exits shall lead directly to the
exterior or street.
(kk) Where there is difference in level between connected areas for horizontal exit,
ramps not more than I in 8 slopes shall be provided. For this purpose steps shall not
be used.
(ll) Doors in horizontal exits shall be open able at all times.
(mm) Ramps with a slope of not more than 1 in 10 may be substituted for the
requirement of staircase. For all slopes exceeding 1 in 10 and wherever the use in
such as to involve danger of slipping, the ramp shall be surfaced with non slipping
material.
(nn) In any building not provided with automatic fire alarm a manual fire alarm system
shall be provided if the total capacity of the building is over 500 persons, or if more
than 25 persons are employed above or below the ground floor, except that no
manual fire alarm shall be required in one story buildings where the entire area is
undivided and all parts thereof are clearly visible to all occupants.
(11) First-aid fire fighting arrangements.— (a) In every factory there shall be provided
and maintained adequate and suitable fire fighting equipment for fighting fires in the early
stages, those being referred to as first aid fire fighting equipment in this rule.
(b) The types of first-aid fire fighting equipments to be provided shall be determined by
considering the different types of fire risks which are classified as follows:—
(i) "Class A fire"-Fire due to combustible materials such as wood, textile, paper, rubbish
and the like.
1. "Light hazard"-Occupancies like offices assembly halls, canteens, rest-rooms,
ambulance rooms and the like:
2. "Ordinary hazard"- Occupancies like saw mills, carpentry shop, small timber
yards. book binding shops, engineering workshop and the like:
3. "Extra hazard"-Occupancies like large timber yards, godowns storing fibrous
materials, flour mills, cotton mills, jute mills, large wood working factories and
the like;
(ii) "Class B fire"-Fire inflammable liquids like oil, petroleum products, solvents, grease,
paint, etc.
(iii) "Class C fire"-Fire arising out of gaseous substances.
(iv) "Class D-fire"-Fire from reactive chemicals, active metals and the like.
(v) "Class E-Fire"-Fire involving electrical equipment and delicate machinery and the
like.
(c) The number and type of first aid fire fighting equipment to be provided shall be as per
the following scale :
(i) Class A Fire
1. Light hazard — One 9 litter water bucket for every 100 square metres of floor
area or part thereof and one 9 later water type (Soda-acid or gas pressure or
bucket pump) extinguishers shall be provided for each 6 buckets or part thereof
with a minimum of one extinguisher and two buckets per compartment of the
building. These equipment shall be so distributed over the entire floor areas that
person shall have to travel not more than 25 metres from any point to reach the
nearest equipment:
2. Ordinary hazard — One 9 litter water bucket for every 100 square metres of
floor area or part thereof and one 9 litter water type (Soda-acid gas pressure or
bucket pump) extinguishers shall be provided for each six buckets or part
thereof, with a minimum of 2 extinguishers and 4 buckets per compartment of
the building. These equipment shall be so distributed over the entire floor area
that a person shall have to travel not more than 15 metres from any point to
reach the nearest equipment:
3. Extra hazard — The scale of equipment would be what is prescribed for
ordinary hazard and, in addition, such extra equipment, as in the opinion of the
inspector, are necessary, having regard to the special nature of occupancy :
Provided that in special cases, the Inspector, after taking into consideration the
circumstances, authorise that the buckets prescribed in this clause may be
dispensed with provided the number of the extinguishers provided is double that
what is prescribed.
(ii) Class B fire— There shall be at least one fire extinguisher either, foam type or
carbon dioxide or dry powder type per 50 square metres of floor area and shall be so
distributed that no person is required to travel more than 15 metres from any point to
reach the nearest equipment: In addition to the requirements extinguishers specified
here requirement as laid down in clause (i) shall also be provided:
(iii) Class C fire— Carbon dioxide or dry chemical powder extinguishers shall be
provided near to each plant or group of plants.
(iv) Class D fire— Special dry powder (Chloride based) type of extinguishers or sand
buckets shall be provided on a scale as laid down for class B fire. The Inspector may
required a higher scale of portable equipment to be provided depending upon the risk
involved.
(v) Class E fire— Carbon dioxide or dry powder type extinguishers shall be provided
near each plant or group of plants depending upon the risk involved.
(d) The first aid fire fighting equipment shall conform to the relevant Indian Standards.
(e) As far as possible the first aid fire fighting equipment shall all be similar in shape and
appearance shall have the same method of operation.
(f) All first aid fire fighting equipment shall be placed in a conspicuous position and shall be
readily and easily accessible for immediate use. Generally, these equipments be placed as
near as possible to the exits or stair landing or normal routes of escape.
(g) All water buckets and bucket pump type extinguishers shall be filled with clean water. All
sand bucket shall be filled with clean dry and fine sand.
(h) All other extinguishers shall be charged appropriately in accordance with the instructions
of the manufacturer.
(i) Each first-aid fire fighting equipment shall be allotted a serial no. by which it shall be
referred to in the records. The following details shall be painted with white paint on the body
of each equipment.
1. Serial number:
2. Date of last refilling; and
3. Date of last inspection.
(j) First-air fire fighting equipment shall be placed on platforms or in cabinets in such a way
that their bottom is 750 mm above the floor level. Fire buckets shall be placed on hooks
attached to a suitable stand or wall in such a way that their bottom is 750 mm above the
floor level. Such equipment if placed out side the building, shall be under sheds or covers.
(k) All extinguishers shall be thoroughly cleaned and recharged immediately after discharge.
Sufficient refill materials shall be kept readily available for this purpose at all times.
(l) All first-aid fire fighting equipments shall be subjected routine maintenance, inspection,
and testing to be carried out by properly trained persons. Periodicity of the routine
maintenance, inspection and test shall conform to the relevant Indian Standards.
(12) Other fire fighting arrangements.— (a) In every factory adequate provision of water
supply for fire fighting shall be made and where the amount of water required in litters per
minute, as calculated from the formula A + B + C + D divided by 20 in 550 or more, power
driven trailer pumps of adequate capacity to meet the requirement of water as calculated
above shall be provided and maintained.
In the above formula—
A. The total area in square metres of all floors including galleries in all building of the
factory,
B. the total area in square metres of all floors and galleries including open space in
which combustible materials are handled or stored,
C. the total area in square metres of all floors over 15 metres above ground level, and
D. the total area in square metres of all floors of all buildings other than those of fire
resisting construction:
Provided that in areas where the fire risk involved does not require use of water, such
areas under B, C or D may, for the purpose of calculation be halved:
Provided further that where the areas under B, C or D are protected by permanent
automatic fire fighting installations approved by any Fire Association or Fire Insurance
Company such areas may, for the purpose of calculation, be halved:
Provided also that where the factory is situated at not more than 3 kilometres from an
established city or town fire service, the pumping capacity based on the amount of water
arrived at by the formula above may be reduced by 25% but no account shall be taken of
this reduction in calculating water supply required under clause (s).
(b) Each trailer pump shall be provided with equipment as per schedule appended to
this rule. Such equipment shall conform to the relevant Indian standards.
(c) Trailer pumps shall be housed in a separate shed or sheds which shall be sited
closed to a principal source of water supplies, in the vicinity of the main risks of the
factory.
(d) In factories where the areas is such as cannot be reached by man-hauling of trailer
pumps within reasonable time, vehicles with towing attachment shall be provided at
the scale of one for every four trailer pumps with a minimum of one such vehicle kept
available at all times.
(e) Water supply shall be provided to give flow of water as required under clause (a) for
at least 100 minutes. At least 50% of this water supply or 450,000 litters whichever is
less shall be in the form of static tanks of adequate capacities .(not less than 450,000
litters each) distributed round the Factory with due regard to the potential fire risks in
the factory (Where piped supply is provided, the size of the main shall not be less
than 15 centimeters diameter and it shall be capable of supplying a minimum of 4500
litters per minute at a pressure of not less than 7 kilo grams per square centimetres).
(f) All trailer pumps including the equipment provided with them and the vehicles for
towing them shall be maintained in good condition and subject to periodical
inspection and testing as required.
(13) Personnel in-charge of equipment and for fire fighting, fire drills etc.— (a) The
first-aid and other fire fighting equipment to be provided as required in sub-rule (11) and
(12) shall be in charge of a trained responsible person.
(b) Sufficient number of person shall be trained in the proper handling of fire fighting
equipment as referred to in clause (a) and their use against the types of fire for which
they are intended to ensure that adequate number of persons are available for fire
fighting both by means of first-aid fire fighting equipment and others. Wherever
vehicles with towing attachment are to be provided as required in clause (d) of sub-
rule (12) sufficient number of persons shall be trained in driving these vehicles to
ensure that trained persons are available for driving them whenever the need arises.
(c) Fire fighting drills shall be held at least once in every 3 months.
(14) Automatic sprinklers and fire hydrants shall be in addition and not in substitution of the
requirements in sub-rules (11) and (12).
(15) If the Chief Inspector is satisfied in respect of any factory or any part of the factory that
owing to the exceptional circumstances such as inadequacy of water supply or infrequency
of the manufacturing process or for any other reason, to be recorded in writing, all or any of
the requirements of the rules are impracticable or not necessary for the protection of
workers, he may by order in writing (which he may at his discretion revoke) exempt such
factory or part of the factory from all or any of the provisions of the rules subject to
conditions as he may by such order prescribe.
Schedule
Equipment to be provided with Trailer Pump
For light trailer pump of a capacity of 680 litters/minute.
1 Armored suction hose of 9 meters length, with wrenches.
1 Metal suction strainer
1 Basket strainer
1 Two-way suction collecting-head
1 Suction adopter.
10 Unlined or rubber lined 70 mm. delivery hose of 25 meters length complete with
quick-release couplings
1 Dividing breaching piece
2 Branch piece with 15 mm. nozzles
1 Diffuser nozzle
1 Stand pipe with blank cap
1 Hydrant Key
4 Collapsible canvas buckets
1 Fire hook (Preventor) with cutting edge
1 25 mm. manila rope of 30 meters length
1 Extension ladder of 9 meters length (where necessary)
1 Heavy axe
1 Spade
1 Pick axe
1 Crowbar
1 Saw
1 Hurricane lamp
1 Electric torch
1 Pair rubber gloves
For large trailer pump of a capacity of 1800 litter/minute
1 Armored suction hose of 9 meters length, with wrenches
1 Metal strainer 1 Basket strainer
1 Three-way suction collecting head
1 Suction adaptor
14 Unlined or rubber lined 70 mm delivery hose of 25 meters length complete with quick
release couplings
1 Dividing breaching piece
1 Collecting breaching piece
4 Branch pipes with one 25 mm, two 20 mm and one diffuser nozzle
2 Stand pipes with blank caps
2 Hydrant keys
6 Collapsible canvas buckets
1 Coiling hook (preventor) with cutting edge
1 50 mm manila rope of 30 meters length
1 Extension ladder of meters length (where necessary)
1 Heavy axe
1 Spade
1 Pick axe
1 Crowbar
1 Saw
1 Hurrican lamp
1 Electric torch
1 Pair rubber gloves.
Note :— If it appears to the Chief Inspector of factories that in any factory the provision of
breathing apparatus is necessary he may by order in writing require the occupier to provide
suitable breathing apparatus in addition to the equipment for light trailer pump or large
trailer pump as the case may be.]
Rule prescribed under sub-section (7) of section 38