LawGrids logoLAWGRIDS.ORG

Rule 61, Rajasthan Factories Rules,1951: Minimum dimensions of manholes

Rajasthan Factories Rules,1951 - Rule 61

Text of rule 61

Minimum dimensions of manholes

61. Minimum dimensions of manholes. — Every chamber, tank, vat, pipe, flue or other confined space, which persons may have to enter and which may contain dangerous fumes to such an extent as to involve risk of the persons being overcome thereby, shall unless there is other effective means of egress, by provided with a manhole which may be rectangular oval or circular in shape. and which shall— (a) in the case of rectangular or oval shape, be not less than @[40 cms] long and @[30 cms] wide: (b) in the case of a circular shape, be not less than @[40 cms] in diameter. Exemption under sub-section (5) of section 37

Previous and next

All provisions of Rajasthan Factories Rules,1951

Questions people ask

Is rule 61 of Rajasthan Factories Rules,1951 still in force?

No repeal of Rajasthan Factories Rules,1951 is recorded.