Rule 19, THE TELANGANA FACTORIES RULES, 1950: Provision of Hygrometer In all departments of a factory wherein artificial humidification is adopted hygrometers shall be provided and maintained in such positions as are approved by the Inspector. The number of hygrometers shall be regulated according to the following scale
THE TELANGANA FACTORIES RULES, 1950 - Rule 19
Text of rule 19
Provision of Hygrometer In all departments of a factory wherein artificial humidification is adopted hygrometers shall be provided and maintained in such positions as are approved by the Inspector. The number of hygrometers shall be regulated according to the following scale
19. Provision of Hygrometer
In all departments of a factory wherein artificial humidification is adopted hygrometers shall be
provided and maintained in such positions as are approved by the Inspector. The number of
hygrometers shall be regulated according to the following scale:-
(a) Weaving department:- One hygrometer for departments wit less than 500 looms, and one
additional hygrometer for every 500 or part of 500 looms in excess of 500.
(b) Other factories:- One hygrometer for each room of less than 8500 cubic metres capacity and
one extra hygrometer for each 5670 cubic metres or part thereof, in excess of this.
(c) One additional hygrometer shall be provided and maintained outside the factory wherein
artificial humidification is adopted and in a position approved by the Inspector, for taking
hygrometer shade readings.
20. Exemption from maintenance of hygrometers
When the Inspector is satisfied that the limits of humidity allowed by the schedule to Rule 18 are
never exceeded, he may for any department of a factory grant exemption from the maintenance of
the hygrometer. The Inspector shall record such exemption in writing.
21. Copy of Schedule to Rule 18 to he affixed near every hygrometer
A legible copy of the schedule to Rule 18 shall be affixed near each hygrometer.
22. Temperature to be recorded at each hygrometer
At each hygrometer maintained in accordance with Rule 19, correct wet and dry bulb temperatures
shall be recorded thrice daily during each working day by competent persons nominated by the
manager and approved by the Inspector. The temperature shall be taken between 7 a.m. and 9 a.m.
between 11 a.m. and 2 p.m. (but not in the rest interval) and between 4 p.m. and 5.30 p.m.
In exceptional circumstances, such additional readings and between such
1. Subs. by G.O.Ms.No.152 (F & B), dated 20-4-1989
hours as the Inspector may specify, shall be taken. The temperatures shall be entered in a Humidity
Register in the prescribed Form No. 6, maintained in the factory. At the end of each month, the
persons who have taken the readings shall sign the register and certify the correctness of the entries.
The register shall always be available for inspection by the Inspector.
23. Specifications of hygrometers
(1) Each hygrometer shall comprise two mercurial thermometers of wet bulb and dry bulb of
similar construction, and equal in dimensions, scale and divisions of scale. They shall be mounted
on a frame with a suitable reservoir containing water.
(2) The wet bulb shall be closely covered with a single layer of muslin kept wet by means of wick
attached to it and dropping into the water in the reservoir. The muslin covering and the wick shall
be suitable for the purpose, clean and free from size or grease.
(3) No part of the wet bulb shall be within 3 inches from the dry bulb or less than one inch from
the surface of the water in the reservoir and the water reservoir shall be below it, on the side of it
away from the dry bulb.
(4) The bulb shall be spherical and of suitable dimensions and shall be freely exposed on all sides
to the air of the room.
(5) The bores of the stems shall be such that the position of top of the mercury column shall be
readily distinguishable at a distance of 2 feet.
(6) Each thermometer shall be graduated so that accurate readings may be taken between 50 and
120 degrees.
(7) Every degree from 50 degrees upto 120 degrees shall be clearly marked by horizontal lines, on
the stem of each fifth and tenth degrees shall be marked by longer marks than the intermediate
degrees and the temperature marked opposite each tenth degree, i.e., 50, 60, 70, 80, 90, 100, 110
and 120.
(8) The markings as above shall be accurate, that is to say, at no temperature between 50 and 120
degrees shall the indicated readings, be in error by more than two-tenths of a degree.
(9) A distinctive number shall be indelibly marked upon the thermometer.
(10) The accuracy of each thermometer shall be certified the National Physical Laboratory,
London, or some competent authority appointed by the Chief Inspector and such certificate shall
be attached to the Humidity Register.
24. Thermometers to be maintained in efficient order
Each thermometer shall be maintained at all times during the period of employment in efficient
working order, so as to give accurate indications and in particular-
(a) the wick and the muslin covering of the wet bulb shall be renewed once a week ;
(b) the reservoir shall be filled with water which shall be completely renewed once a day. The
Chief Inspector may direct the use of distilled water or pure rain water in any particular mill or
mills in certain localities;.
(c) no water shall be applied directly to the wick or covering during the period of employment.
25. An inaccurate thermometer not to be used without fresh Certificate
If an Inspector gives notice in writing that a thermometer is not accurate, it shall not, after one
month from the date of such notice, be deemed to be accurate unless and until it has been re-
examined as prescribed and a fresh certificate obtained which certificate shall be kept attached to
the Humidity Register.
26. Hygrometer not to be affixed to wall, etc., unless protected by wood
(1) No hygrometer shall be affixed to a wall, pillar, or other surface unless protected there from by
wood or other non-conducting material at least half an inch in thickness and distant at least one
inch from the bulb of each thermometer.
(2) No hygrometer shall be fixed at a height of more than 5 feet 6 inches from the floor to the top
of thermometer stem or in the direct droughts from a fan, window or ventilating opening.
27. No reading to he taken within 15 minutes of renewal of water
No reading shall be taken for record on any hygrometer within 15 minutes of the renewal of water
in the reservoir.
28. How to introduce steam for humidification
If any room in which steam pipes are used for the introduction of steam for the purpose or artificial
humidification of the air the following provisions shall apply-
(a) The diameter of such pipe shall not exceed
1
[50 mm] and in the case of pipes installed after
1st day of April, 1949 the diameter shall not exceed
1
[25 mm.]
1. Subs. by G.O.Ms.No.152 (F & B), dated 20-4-1989
(b) Such pipes shall be as short as is reasonably practicable
(c) All hangers supporting such pipes shall be separated from the base pipes by an efficient
insulator not less than half an inch in thickness
(d) No uncovered jet from pipe shall project more than
1
[11.5 cm.] beyond the outer surface of
any cover
(e) The steam pressure shall be as low as practicable and shall not exceed
1
[5 kg.] per square inch
(f) The pipe employed for the introduction of steam into the air in a department shall be effectively
covered with such non-conducting material, as may be approved by the Inspector in order to
minimise the amount of heat radiated by them into the department.
RULES 29 TO 33 PRESCRIBED UNDER SUB-SECTION (4) OF SECTION 17
29. Artificial lighting
[Omitted by G.O.Ms.No. 978, dated 4-5-1960]
30. Lighting of interior parts
2
[(1) The general illumination over those interior parts of a factory where persons are regularly
employed shall be not less than
1
[65 Lux] measured in the horizontal plain at a level of 90 cm. above
the floor,
Provided that in any such parts in which the mounting height of the light source for general
illumination has to necessarily exceed 7.6 mtrs. measured from the floor or where the structure of
the room or the position or construction of the fixed machinery or plant prevents the uniform
attainment of the standard specified above, the general illumination at the said level of 7.6 mtrs.
shall be not less than
1
[22 Lux] and where work is actually being done the illumination shall be
not less than
1
[65 Lux] candles.
(1) The illumination over all other interior parts of the factory over which persons employed pass
shall, when and where a person is passing be not less than 0.50 foot candles at floor level.
(2) The standard specified in this rule shall be without prejudice to the provision of any additional
illumination required to render the lighting sufficient and suitable for the nature of the work.
1. Subs. by G.O.Ms.No. 152 (F & B), dt: 20-4-1989
2. Sub- rule (1) and the proviso subs. by G.O.Ms.No. 808, dt: 17-11-1980
31. Prevention of glare
(1) Where any source of artificial light in the factory is less than
1
[4.9 mtrs.] above floor level,
no part of the light source of the lighting fitting having a brightness greater than 55 candles per
square inch shall be visible to persons while normally employed with
2
[30 mtrs.] of the source,
except where the angle of elevation from the eye to the source or part of the fitting as the case
may be exceeds 20 degrees.
(2) Any local light that is to say, an artificial light designed to illuminate particularly the area or
part of the area of work of a single operative or small group of operatives working near each other
shall be provided with a suitable shade of opaque material to prevent glare or with other
effective means by which the light source is completely screened from the eyes of every person
employed at a normal working place or shall be so placed that no such person is exposed to glare
there from.
32. Power of Chief Inspector to exempt
Where the Chief Inspector is satisfied in respect of any particular factory or part thereof or in
respect of any description of workroom or process that any requirement of Rules 30 and 31 is
inappropriate or is not reasonably practicable, he may, by order in writing, exempt the factory or
part thereof, or description of work room or process from such requirement to such extent and
subject to such conditions as he may specify.
33. 2[x x x]
RULES 34 TO 39 PRESCRIBED UNDER SUB-SECTION (4) OF SECTION 18
34. Quantity of drinking water
The quantity of drinking water to be provided for the workers in every factory. shall be at least 5
liters per worker employed in the factory and such drinking water shall be readily available at all
times during working hours.
3
Previous and next
Questions people ask
Is rule 19 of THE TELANGANA FACTORIES RULES, 1950 still in force?
No repeal of the TELANGANA FACTORIES RULES, 1950 is recorded.