Regulation 122, Indian Boiler Regulations, 1950: Furnaces of Horizontal Boilers
Indian Boiler Regulations, 1950 - Regulation 122
Text of regulation 122
Furnaces of Horizontal Boilers
122. Furnaces of Horizontal Boilers.—(a) The &ection* of Hie, internal flues
snail each be in one plate and Bhall be bent while cold to circular form and shall b»
welded longitudinally.
(b) The maximum permissible variation in diameter at any cross section shall
not exceed the thickness of the plate.
(c) The welds shall be placed at tho lower part of the flues, and shall break
joint in successive sections by at least 12 inches.
(d) Each flange for the circular seams shall be formed at one heat by suitable
machinery.
(e) The sections shall be allowed to cool gradually to avoid internal stresses.
(f) The caulking edges of all fluo flanges shall be maohined or machine gas
cut.
(g) The circular seams shall be arranged so that they do not fall in line with
those of the adjacent flue or with the circumferential seams of the shell and are at
least 6 inches apart,
(h) When flues ate flanged for attachment to both end plates tho total length of
each completed flue thall not exceed the length of the shell measured from the inner
surface ot tho back end plate to the inner surface of the front end plate, both ad-
jacent to the shell.
(i) Where the flues are flanged for attachment to tho end plates, tho end sec-
tions sball be 1/16 inch thicker than the remaining sections, except in cases where the
calculated thickness is over 13/16 inch, when the end-sections shall be 7/8 inch in
thickness.
(j) Tho flanged portion of furnace rings shall have a radius of curvative of
not less than 1 inch on water side.
(k) Seotions of corrugated flues may be fusion butt welded oiroumferontially
and afterwards stress relieved by heat treatment.
Previous and next
Questions people ask
Is regulation 122 of Indian Boiler Regulations, 1950 still in force?
No repeal of Indian Boiler Regulations, 1950 is recorded.