Regulation 34, Indian Boiler Regulations, 1950: Stay and Rivet Bars

Indian Boiler Regulations, 1950 - Regulation 34

Text of regulation 34

Stay and Rivet Bars

34. Stay and Rivet Bars—(a) Process.—To comply with Regulation 33 (a). (b) Chemical Composition—To comply wilh Regulation 33 (b). (c) Freedom from Detects.—To comply with Regulation 33(o) (d) Rolling Margin.—The bars in any part shall not be more than 1% over or more than 1/2 % under the specified diametci (e) Tensile Tests.—The tonsile broaking-sttength shall not ho less than 14 tona per sq. in. with an elongation of noi IOHH than 40% on the Standard Test Pieoe B. (f) Bend Teats. -To comply wilh Regulation 33(f). (g) Dump Tests. -Apiece of tod 1 in. long shall be placed on end and hammered or crushed down cold to a thick nebs of 3/8in. without showing either crack or flaw on tho circumference of the resulting dine. (h) Number of Tests.—One bar, from wliioh the required test specimens shall be taken, shall be solei ted at rnndom from each batch of 50 (or part thereof) bars of eaoh size from each melt. From each bar selected one tensile test, one cold bend test, ono hot bend test, and ono dump test shall bo made.