Regulation 224, Indian Boiler Regulations, 1950.: Corrugated Fireboxes oi Vertical Boilers
Indian Boiler Regulations, 1950. - Regulation 224
Text of regulation 224
Corrugated Fireboxes oi Vertical Boilers
224. Corrugated Fireboxes oi Vertical Boilers.—For tho somi-spirally corrugated
fireboxes of "Sentinol" standard motor wagon boilers tho -working pressure shall be
determined by tho following formula :—
C(t-l)
W.P. = • Eqn.(Sl)
D
t is the thioknesB of the firebox plate in 33nds of an inoh,
T> is tho mean of the external diameters of firebox moasured over the plain part
at each end at commencement of curvature of flange.
C =• 390.