Regulation 224, Indian Boiler Regulations, 1950.: Corrugated Fireboxes oi Vertical Boilers

Indian Boiler Regulations, 1950. - Regulation 224

Text of regulation 224

Corrugated Fireboxes oi Vertical Boilers

224. Corrugated Fireboxes oi Vertical Boilers.—For tho somi-spirally corrugated fireboxes of "Sentinol" standard motor wagon boilers tho -working pressure shall be determined by tho following formula :— C(t-l) W.P. = • Eqn.(Sl) D t is the thioknesB of the firebox plate in 33nds of an inoh, T> is tho mean of the external diameters of firebox moasured over the plain part at each end at commencement of curvature of flange. C =• 390.