Regulation 219, Indian Boiler Regulations, 1950.: Brass and Copper Tubes
Indian Boiler Regulations, 1950. - Regulation 219
Text of regulation 219
Brass and Copper Tubes
219. Brass and Copper Tubes.—Th« thickness of tapered brass and copper
smoke tubes for locomotive boilers shall, in the oase of tubes of an external dia-
meter of 1J to If inches inclusive, bo not less than 12 S. W. G. (• 104 inch) at the
emoke-box end and 10 S.W.G. (• 128 inch) at the other and in the oase of tubes of
an external diameter of 2 to 2$ inohes inoluflive, the thickness at the smoke-box
end shall not be less than 11 S. W. G. (116 inch) and at the other end not lee»
than 9 S. W. G. (144inoh).
FURNACES
Previous and next