185. Circumferential and End Seams of Water Tube Boilers.—The suitability
of eirournferential seams inducting the seams joining ends to shells shall be verified
by the following formula :— '
K x J x ( t - 2 )
is equal to or greater than WP . . . Eqn. (17)
DxC
K -= 160 for 26/30 tons tensile plates.
K. = 157 for 28/32 tons tensile plates.
Due to higher stresses, see Reg. 271 and 340.
WP =• Tho working pressure in lbs. per sq. in.
D = The diameter of shell in inches, measured inside the outer ring of plates.
J Circumferential Joint effioienoy calculated by Eqns. 2 or 3.
C — 8-24 where tho seams are made with lap joints and are treble riveted
= 8 41 where the seams are made with lap jointu and are double riveted
— 9-60 where the seams are made with lap joints and are single riveted.
t — thickness of plate in 32nds of an inch.