Regulation 49, Indian Boiler Regulations, 1950.: (a) Tensile Test

Indian Boiler Regulations, 1950. - Regulation 49

Text of regulation 49

(a) Tensile Test

49. (a) Tensile Test—Test pieces out from the ends of tho selected tubon shall comply with tho following requirements:— — Strips flit from tubes tind timtod in their curvnd condition. Testi LoiigtliH tuknn from fniwhod tubes (en<ln oftnboH to be plugged for gripw). Ultimuto T«mile Htrima in tonn p«r sq. in Not lorn than 27 2r, Not more thtin 33 33 Minimum elonfjution per oont. on M mches 1/4* tdk'k ami ovor 10 23 LOHH than 1/4" thick 17 21 (b) Flattening Test.—A ring not less than 2 inches in length out from one ond of each selected tube shall be flattened between two parallel flat surfaces, the width of which shall be not less than 1J times the diameter of the tubo. When the pTessure is released, tho interior surfaces of the test piece (at the middle) shall remain at a distance apart of not more than three timos the specified thickness of the tube and the test piece ahaII then show no sign of crack or flaw. (e) Expanding Tests.—Tho tubes shall withniaml expanding by a drift expander having a total included angle of between 40" and 60° (20° to 30" each sido) to the following increases in external diameter without showing crack or flaw :—7 Thk'kiiHHH of tube ]0 S.W.G. ftnd thinner Thinner than 9 S.W.G-. up to un<l mcluriiup: 0 S.W.U. . Thinker than fl S.W.Q Inert a«iH in rlitimetor pur i-ent. 12J «i