Regulation 7, Indian Boiler Regulations, 1950.: Boiler Shells not in accordance with standard conditions

Indian Boiler Regulations, 1950. - Regulation 7

Text of regulation 7

Boiler Shells not in accordance with standard conditions

7. Boiler Shells not in accordance with standard conditions.—When the standard conditions are not complied with, additions to the appropriate coefficient as defined in Regulation 176 shall be made as follows :— (a) When there are no proofs of testa of steel, 15 per cent, of the standard co- •emciant. (b) When a boiler has not been inspected during construction by an Inspecting Officer and certified by him, 10 per cent, of the standard coefficient. (o) When the workmanship is in any way doubtful and the Inspector is not /satisfied that any of the foregoing additions to the coefficient would be sufficient. SEC. 3] THE GAZETTE OF INDIA EXTBAOEDINAEY 611 to meet the circumstances, such percentage of the standard co-efficient as the Chief Inspector deems fit. Provided that nothing in this regulation shall apply to a hollow forged or a fusion welded drum if it is constructed under the supervision of an Inspecting Authority.