APPENDIX-II

APPENDIX-II CRITICAL ACTIVITIES IMPLEMENTATION SCHEDULE CRITICAL ACTIVITY TIME SCHEDULE Cathodic Protection (CPI lnsoection As per Petroleum and Pioaina/lntelliaent Piqoina Natural Gas Regulatory Surveillance Board (Technical Coatina Survey Standards and Hydro-testing Specifications including Safety Standards for natural gas pipelines) Renulations. 2009 GIS Maooina lmolementation 2 years Leak Detection Svstem lmolementation 2 years 63 THE GAZETTE OF INDIA : EXTRAORDINARY [PART Ill-SEC. 4) APPENDIX· Ill SUGGESTIVE CHART FOR SELECTION OF INTEGRITY ASSESSMENT METHOD• WITH RESPECT TO SPECIFIC THREAT Threat Group Threat Integrity Assessment Assessment interval Method• (A)Time-Dependent External Corrosion lnline inspection, Max.I 0 year** External Corrosion Direct Assessment Internal Corrosion Inline inspection, Max. I 0 year•• Internal Corrosion Direct Assessment Stress Corrosion lnline inspection, Max. I 0 year•• Cracking Direct Assessment (B} Stable a} Manufacturing Defective Pipe Seam Hydro-test (Post Before related defects Construction), Iniine commissioning or as Defective Pipe inspection and when required b) Welding I Defective Pipe Girth Fabrication related Weld . Defective fabrication Weld Wrinkle bend or buckle Caliper Pigging I . Electronic Gauging Pi•<>ing (EGP) Stripped threads/broken Visual Examination I pipe Gas Leakage Survey c) Equipment Gasket I 0-ring Failure Visual Examination I Gas Leakage Survey Control I Relief Visual Examination I euuipment malfunction Gas Leakage Survey Seal pump packing Visual Examination I failure Gas Leakage Survey (C)Time-lndependent a)Third Party I Damage inflicted by Public Education (See Monthly /quarter! y Mechanical first, second, or third Communication Plan Damage parties (Instantaneous I & preventive actions), Immediate failure) Patrolling, ROW Maintenance, External Protection Previously da,maged Above + Leakage pipe (delayed failure Survey, Rehabilitation mode) Vandalism All above b)lncorrect Incorrect Operational Compliance Audits Operations procedure -· .. - wh~n I c) Weather Weather related Leakage survey, As and Related and Surveillance required Outside Forces Li11.htninl! Sunze diverters Heavy rains or floods Anti-buoyancy .inspection, Surveillance Earth Movements Strain monitoring, Leakaiie survev. Creek Area Effects Surveillance, Pipe to As and when Soil Potential surveys required near creek, Leakage survey, Anti-Buoyancy Inspection, Integrated Surveillance Svstem Muddy/Marshy area Surveillance, Pipe to As and when effects Soil Potential surveys, required Leakage survey, Cathodic Protection monitoring, Integrated Surveillance Svstem River Bed Movements Surveillance, Pipe to As and when Soi I Potential surveys, required Leakage survey, Cathodic Protection monitoring, Anti- Buoyancy Inspection, Integrated Surveillance Svstem • Some of the Important lntegrtty Assessment Methods hove been briefed In Schedule- 5 of these regulations •• lnline Inspection frequency to be as per Petroleum and Natural Gos Regulatory Boord (Technlcal Standards and Specifications Including Safety Standards tor natural gos plpellnes) Regulations, 2009

Previous and next

All provisions of 24. Integrity Management System for Natural gas pipelines, Regulation, 2012

Questions people ask

Is appendix II of 24. Integrity Management System for Natural gas pipelines, Regulation, 2012 still in force?

No repeal of 24. Integrity Management System for Natural gas pipelines, Regulation, 2012 is recorded.